{"product_id":"comen-nv8-neonatal-ventilator","title":"Comen NV8 Neonatal Ventilator","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eComen NV8\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is a dedicated \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003enon-invasive neonatal ventilator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e engineered for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003enewborns, premature infants, and low-birth-weight babies\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, including those weighing as little as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e500 g\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. It brings together \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNCPAP, NIPPV, SNIPPV (with backup ventilation), and HFNC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e modes in a single device, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePeak Inspiratory Pressure (PIP) reaching up to 20 cmH₂O\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—a pressure range designed to support non-invasive respiratory care while reducing reliance on tracheal intubation\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"1\"\u003e\u003ca href=\"https:\/\/ru.comen.com\/es\/products\/NV8\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/pdf.medicalexpo.com\/pdf\/comen\/electronic-ventilator-nv-series\/70046-240753.html\" rel=\"noreferrer\" aria-label=\"7\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe NV8’s \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eiFlow intelligent closed-loop control system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e continuously monitors airway pressure near the infant’s nose and compensates for gas leakage in real time, supporting stable pressure delivery even during high-flow ventilation\u003c\/span\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eabdominal respiratory sensor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e triggers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapnea wake-up\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in NCPAP mode and supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSNIPPV synchronization accuracy exceeding 90%\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e across 10 sensitivity levels, directly addressing the irregular breathing patterns common in premature infants\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"3\"\u003e\u003ca href=\"https:\/\/ru.comen.com\/es\/products\/NV8\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/pdf.medicalexpo.com\/pdf\/comen\/electronic-ventilator-nv-series\/70046-240753.html\" rel=\"noreferrer\" aria-label=\"7\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe device is built around an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e8-inch LED touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e15° tilt\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for ergonomic viewing, and includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edual-CPU monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e360° visible alarm light\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintelligent warning system with double confirmation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for key parameter settings\u003c\/span\u003e\u003cspan class=\"\"\u003e. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebuilt-in lithium battery provides up to 4 hours of operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e during power interruption or intra-hospital transport, and the unit is mounted on an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ealuminum alloy trolley\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e designed to reduce noise and enhance mobility\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"5\"\u003e\u003ca href=\"https:\/\/ru.comen.com\/es\/products\/NV8\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/pdf.medicalexpo.com\/pdf\/comen\/electronic-ventilator-nv-series\/70046-240753.html\" rel=\"noreferrer\" aria-label=\"7\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eFor monitoring, the NV8 supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSpO₂ via Masimo or Nellcor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e modules and includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eonline oxygen concentration calibration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e that operates without interrupting ventilation\u003c\/span\u003e\u003cspan class=\"\"\u003e. The device is compatible with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNV Flow \/ Neo.Flow pressure generators\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e as standard, and also accepts \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInfant Flow, Infant Flow LP, and Medijet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e generators to match existing departmental setups\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"9\"\u003e\u003ca href=\"https:\/\/ru.comen.com\/es\/products\/NV8\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRegulatory status:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e The NV8 holds \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChina NMPA registration (国械注准20163541772)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass III medical device\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, valid through \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eJanuary 21, 2026\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Comen’s quality management system for neonatal and pediatric ventilators is certified under \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEU MDR 2017\/745 Annex IX by SGS FIMKO (Notified Body 0598), Certificate FI23\/1008002\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, valid from \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDecember 23, 2025 to September 5, 2028\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNo FDA 510(k) clearance specific to the NV8 was identified in the public FDA database during preparation of this page.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e Availability and cleared claims vary by market; confirm local registration and labeling before purchase.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"11\"\u003e\u003ca href=\"https:\/\/imda.moh.gov.vn\/documents\/10182\/86775853\/upload_00011288_1785921815076.pdf?version=1.0\u0026amp;fileId=86811080#1#1#1\" rel=\"noreferrer\" aria-label=\"27\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/www.jmylhc.com\/huxiji\/1331.html\" rel=\"noreferrer\" aria-label=\"28\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe NV8 is built for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eneonatal intensive care units, special care nurseries, and delivery rooms\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e that need a dedicated non-invasive ventilation platform for fragile patients—with the pressure performance, synchronization technology, and transport capability that preterm respiratory support demands.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eFour Non-Invasive Modes in One Device: NCPAP, NIPPV, SNIPPV, and HFNC\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe NV8 integrates \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNasal Continuous Positive Airway Pressure (NCPAP)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNasal Intermittent Positive Pressure Ventilation (NIPPV)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSynchronized Nasal Intermittent Positive Pressure Ventilation (SNIPPV)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebackup ventilation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHigh-Flow Nasal Cannula (HFNC)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e therapy in a single unit\u003c\/span\u003e\u003cspan class=\"\"\u003e. This mode breadth allows a single device to support a neonatal patient from \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einitial non-invasive support through weaning\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, without requiring separate machines for each modality. The SNIPPV mode includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebackup ventilation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and HFNC includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epressure monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—configurations intended to support continuity of care as the infant’s respiratory status evolves.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"13\"\u003e\u003ca href=\"https:\/\/wap-cnki-net-443.webvpn.imac.edu.cn\/touch\/web\/Journal\/Article\/ZGQX201719069.html\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003ePIP up to 20 cmH₂O with iFlow Closed-Loop Pressure Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe NV8 delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePeak Inspiratory Pressure up to 20 cmH₂O\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, a pressure ceiling positioned to support effective non-invasive ventilation in newborns without escalating to invasive support\u003c\/span\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eiFlow closed-loop control system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eproximal pressure monitoring near the infant’s nose\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, feeding data back to the CPU for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ereal-time pressure adjustment and leak compensation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—supporting stable pressure delivery even when circuit leakage is present or during high-flow ventilation\u003c\/span\u003e\u003cspan class=\"\"\u003e. The device also includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic leakage compensation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e as a standard function\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"15\"\u003e\u003ca href=\"https:\/\/ru.comen.com\/es\/products\/NV8\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/pdf.medicalexpo.com\/pdf\/comen\/electronic-ventilator-nv-series\/70046-240753.html\" rel=\"noreferrer\" aria-label=\"7\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eAbdominal Respiratory Sensor with Apnea Wake-Up and \u0026gt;90% Synchronization\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003ePremature infants frequently exhibit \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eirregular abdominal breathing and apnea\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The NV8 addresses this with an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eabdominal respiratory sensor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e that monitors breathing patterns and triggers an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapnea wake-up function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in NCPAP mode—delivering a strong airflow during detected apnea events\u003c\/span\u003e\u003cspan class=\"\"\u003e. In \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSNIPPV mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, the sensor supports synchronization with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e10 sensitivity levels\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, achieving \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebreathing synchronization accuracy exceeding 90%\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e according to Comen\u003c\/span\u003e\u003cspan class=\"\"\u003e. This combination is intended to reduce the incidence of apnea and support patient-ventilator synchrony in spontaneously breathing infants.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"18\"\u003e\u003ca href=\"https:\/\/ru.comen.com\/es\/products\/NV8\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/pdf.medicalexpo.com\/pdf\/comen\/electronic-ventilator-nv-series\/70046-240753.html\" rel=\"noreferrer\" aria-label=\"7\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e8-Inch Touchscreen with 15° Tilt and Dual-CPU Monitoring\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e8-inch LED touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is mounted at a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e15° tilt\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for ergonomic viewing from beside the incubator, with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ewide viewing angle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e intended to support quick parameter checks during rounds\u003c\/span\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edual-CPU monitoring architecture\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provides a secondary processing path for enhanced operational reliability, and the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintelligent warning system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edouble confirmation when setting key parameters\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e to reduce setting errors\u003c\/span\u003e\u003cspan class=\"\"\u003e. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e360° visible alarm light\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports awareness from across the NICU.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"21\"\u003e\u003ca href=\"https:\/\/ru.comen.com\/es\/products\/NV8\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/pdf.medicalexpo.com\/pdf\/comen\/electronic-ventilator-nv-series\/70046-240753.html\" rel=\"noreferrer\" aria-label=\"7\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eUp to 4 Hours of Battery for Transport and Power Interruption\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebuilt-in lithium battery provides up to 4 hours of operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, supporting \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintra-hospital transport\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003econtinuity during power failure\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e without interrupting ventilation\u003c\/span\u003e\u003cspan class=\"\"\u003e. The aluminum alloy trolley is designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emobility and reduced noise\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e during movement between departments\u003c\/span\u003e\u003cspan class=\"\"\u003e. The NV8 is cleared for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003euse in medical institutions and intra-hospital transport\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e under its China registration\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"24\"\u003e\u003ca href=\"https:\/\/pdf.medicalexpo.com\/pdf\/comen\/electronic-ventilator-nv-series\/70046-240753.html\" rel=\"noreferrer\" aria-label=\"7\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/www.jmylhc.com\/huxiji\/1331.html\" rel=\"noreferrer\" aria-label=\"28\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eBroad Pressure Generator Compatibility: NV Flow, Neo.Flow, Infant Flow, Medijet\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe NV8 ships standard with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNV Flow \/ Neo.Flow pressure generators\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecomfort and sealing performance\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in neonatal interfaces\u003c\/span\u003e\u003cspan class=\"\"\u003e. It is also \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecompatible with Infant Flow, Infant Flow LP, and Medijet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e generators, allowing departments that have standardized on a particular pressure generator to adopt the NV8 without changing their consumable ecosystem\u003c\/span\u003e\u003cspan class=\"\"\u003e. The device includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emulti-size soft silicone nasal plugs, masks, and cotton bonnets\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e suitable for premature infants as small as 500 g\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"29\"\u003e\u003ca href=\"https:\/\/ru.comen.com\/es\/products\/NV8\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/pdf.medicalexpo.com\/pdf\/comen\/electronic-ventilator-nv-series\/70046-240753.html\" rel=\"noreferrer\" aria-label=\"7\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSpO₂ Monitoring and Online Oxygen Calibration Without Interruption\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe NV8 supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSpO₂ monitoring via Masimo or Nellcor modules\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, providing clinicians with blood oxygen data to assess the effectiveness of non-invasive support\u003c\/span\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eonline oxygen concentration calibration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e circuit allows the oxygen cell to be calibrated \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ewhile the NV8 continues ventilating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—removing the need to interrupt therapy for routine calibration\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"31\"\u003e\u003ca href=\"https:\/\/ru.comen.com\/es\/products\/NV8\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDevice Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eDedicated non-invasive neonatal ventilator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Population\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eNewborns, premature infants, and low-birth-weight infants (compatible with infants as small as 500 g)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"33\"\u003e\u003ca href=\"https:\/\/pdf.medicalexpo.com\/pdf\/comen\/electronic-ventilator-nv-series\/70046-240753.html\" rel=\"noreferrer\" aria-label=\"7\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVentilation Modes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eNCPAP; NIPPV; SNIPPV (with backup ventilation); HFNC (with pressure monitoring)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"34\"\u003e\u003ca href=\"https:\/\/wap-cnki-net-443.webvpn.imac.edu.cn\/touch\/web\/Journal\/Article\/ZGQX201719069.html\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePeak Inspiratory Pressure (PIP)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eUp to 20 cmH₂O\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"35\"\u003e\u003ca href=\"https:\/\/ru.comen.com\/es\/products\/NV8\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePEEP Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1–13 cmH₂O (distributor documentation); clinical study settings referenced at 4–8 cmH₂O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eApnea Wake-Up Pressure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e3–20 cmH₂O (distributor documentation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eApnea Interval\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eOFF; 1 s–30 s (distributor documentation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInspiratory Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.1–15 s (distributor documentation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRespiratory Rate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1–120 bpm (distributor documentation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFiO₂\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e21%–100% (±3%), continuously adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHFNC Flow Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e0.5–25 L\/min (distributor documentation)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"42\"\u003e\u003ca href=\"http:\/\/www.jmylhc.com\/huxiji\/1331.html\" rel=\"noreferrer\" aria-label=\"28\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eManual Ventilation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eTime 1–30 s adjustable; airway pressure 2–25 cmH₂O; flow 2.0–30 L\/min\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"43\"\u003e\u003ca href=\"http:\/\/www.jmylhc.com\/huxiji\/1331.html\" rel=\"noreferrer\" aria-label=\"28\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQuick Oxygen Boost\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eUp to 120 s; concentration 22%–100% continuously adjustable\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"44\"\u003e\u003ca href=\"http:\/\/www.jmylhc.com\/huxiji\/1331.html\" rel=\"noreferrer\" aria-label=\"28\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e8-inch LED touchscreen; 15° tilt\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"45\"\u003e\u003ca href=\"https:\/\/ru.comen.com\/es\/products\/NV8\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePressure Control\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eiFlow closed-loop system with proximal pressure monitoring and leak compensation\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"46\"\u003e\u003ca href=\"https:\/\/pdf.medicalexpo.com\/pdf\/comen\/electronic-ventilator-nv-series\/70046-240753.html\" rel=\"noreferrer\" aria-label=\"7\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSynchronization\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eAbdominal respiratory sensor; 10 sensitivity levels; \u0026gt;90% SNIPPV synchronization accuracy\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"47\"\u003e\u003ca href=\"https:\/\/ru.comen.com\/es\/products\/NV8\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSpO₂ Monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eMasimo or Nellcor module compatible\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"48\"\u003e\u003ca href=\"https:\/\/ru.comen.com\/es\/products\/NV8\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOxygen Calibration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eOnline calibration without interrupting ventilation\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"49\"\u003e\u003ca href=\"https:\/\/ru.comen.com\/es\/products\/NV8\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBattery\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eBuilt-in lithium battery; up to 4 hours operation\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"50\"\u003e\u003ca href=\"https:\/\/pdf.medicalexpo.com\/pdf\/comen\/electronic-ventilator-nv-series\/70046-240753.html\" rel=\"noreferrer\" aria-label=\"7\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMonitoring Architecture\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eDual-CPU\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"51\"\u003e\u003ca href=\"https:\/\/pdf.medicalexpo.com\/pdf\/comen\/electronic-ventilator-nv-series\/70046-240753.html\" rel=\"noreferrer\" aria-label=\"7\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAlarm System\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e360° visible alarm light; intelligent double-confirmation for key parameter settings\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"52\"\u003e\u003ca href=\"https:\/\/pdf.medicalexpo.com\/pdf\/comen\/electronic-ventilator-nv-series\/70046-240753.html\" rel=\"noreferrer\" aria-label=\"7\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePressure Generator Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eNV Flow \/ Neo.Flow (standard); Infant Flow; Infant Flow LP; Medijet\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"54\"\u003e\u003ca href=\"https:\/\/ru.comen.com\/es\/products\/NV8\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTrolley\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eAluminum alloy construction for reduced noise and mobility\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"55\"\u003e\u003ca href=\"https:\/\/pdf.medicalexpo.com\/pdf\/comen\/electronic-ventilator-nv-series\/70046-240753.html\" rel=\"noreferrer\" aria-label=\"7\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eData Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eLog function; trend graphs and tables; storage and export (distributor documentation)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"56\"\u003e\u003ca href=\"http:\/\/www.jmylhc.com\/huxiji\/1331.html\" rel=\"noreferrer\" aria-label=\"28\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRegulatory Status\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eChina NMPA Class III: 国械注准20163541772 (valid through 2026-01-21)\u003c\/span\u003e\u003cspan class=\"\"\u003e; EU MDR 2017\/745 QMS Certificate FI23\/1008002 (SGS FIMKO, NB 0598, valid 2025-12-23 to 2028-09-05)\u003c\/span\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eno FDA 510(k) specific to NV8 identified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; availability and cleared claims vary by market\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"57\"\u003e\u003ca href=\"https:\/\/imda.moh.gov.vn\/documents\/10182\/86775853\/upload_00011288_1785921815076.pdf?version=1.0\u0026amp;fileId=86811080#1#1#1\" rel=\"noreferrer\" aria-label=\"27\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/www.jmylhc.com\/huxiji\/1331.html\" rel=\"noreferrer\" aria-label=\"28\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the Comen NV8?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eClinical or Operational Challenge\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eNV8 Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed a dedicated non-invasive neonatal platform with multiple modes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eNCPAP, NIPPV, SNIPPV (with backup), and HFNC in one device; PIP up to 20 cmH₂O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed stable pressure despite circuit leaks in tiny patients\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eiFlow closed-loop control with proximal pressure monitoring and real-time leak compensation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePremature infants with irregular breathing and apnea risk\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAbdominal respiratory sensor; apnea wake-up in NCPAP; SNIPPV synchronization \u0026gt;90% with 10 sensitivity levels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed transport capability within the hospital\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eBuilt-in battery up to 4 hours; aluminum trolley; cleared for intra-hospital transport\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed compatibility with existing pressure generators\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eNV Flow \/ Neo.Flow standard; also accepts Infant Flow, Infant Flow LP, and Medijet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed to support the smallest premature infants\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eCompatible with infants as small as 500 g; multi-size soft silicone nasal interfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed SpO₂ and oxygen calibration without interrupting therapy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eMasimo\/Nellcor SpO₂; online oxygen calibration during ventilation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed clear regulatory documentation for procurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eChina NMPA Class III registration; EU MDR QMS certificate from SGS FIMKO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46504533884972,"sku":null,"price":7979.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/ComenNV8NeonatalVentilator.png?v=1793003586","url":"https:\/\/www.globalhealthcaremedical.com\/products\/comen-nv8-neonatal-ventilator","provider":"Global Healthcare Medical","version":"1.0","type":"link"}