{"product_id":"edan-cx10-patient-monitor","title":"EDAN CX10 Patient Monitor","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEDAN CX10\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e10.1-inch entry point into EDAN's CX series of multi-parameter patient monitors\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—a bedside and in-hospital transport solution sharing the same monitoring platform as the larger CX12 (13.3-inch) and CX15 (15.6-inch) models. Where the CX10 differs is its \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecompact 10.1-inch enclosure\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, making it suitable for general wards, sub-acute units, and transport scenarios where space and portability are practical constraints\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"1\"\u003e\u003ca href=\"https:\/\/www.edan.com\/Uploads\/20240730030130_658046.pdf#1#1\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eStandard parameters on the CX10 include \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3\/5-lead ECG, RESP, EDAN SpO₂, EDAN NIBP, PR, and 1-channel TEMP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, running on EDAN's \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eiSEAP™ ECG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eiFAST™ NIBP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eiCUFS™ NIBP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eiMAT™ SpO₂\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e algorithms. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e10.1-inch touchscreen (1024 × 600)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003egesture operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, supplemented by a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003erotary knob\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and physical buttons for alternative control. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efanless cooling design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e reduces power consumption and dust accumulation, and the enclosure is compatible with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eup to 31 common medical disinfectants\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for routine wipe-down between patients\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"2\"\u003e\u003ca href=\"https:\/\/www.edan.com\/Uploads\/20240730030130_658046.pdf#1#1\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eFor expansion, the CX10 accepts \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional 6\/12-lead ECG, 2-channel TEMP, EDAN G2 sidestream CO₂ (with iCARB™ algorithm), cardiac output (C.O.), a thermal printer, and built-in Wi-Fi\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—parameters that move the device beyond basic vital-signs monitoring into procedure and higher-acuity support. Data management covers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e1,200 NIBP records, 48 hours of 1-second trend data (or 240 hours at 1-minute resolution), 1,000 alarm events, and 48 hours of full-disclosure waveforms\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWi-Fi, HDMI, and a multifunction interface\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for connectivity\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"4\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-b-cardiovascular-diagnostic-devices\/MHX\/K250179?doc=summary\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe CX10 is built for departments that need \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ea common monitoring platform across different acuity levels\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e: the same algorithms and interface logic as the CX12 and CX15, in the smallest enclosure in the CX series.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e10.1-Inch Touchscreen with Rotary Knob for Alternative Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e10.1-inch color TFT touchscreen (1024 × 600)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintuitive gesture operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for parameter selection and menu navigation\u003c\/span\u003e\u003cspan class=\"\"\u003e. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003erotary knob\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provides an alternative physical control, allowing operation when touch interaction is not practical. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLarge font, trend, OxyCRG, and full ECG display modes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e let the clinical team prioritize numerics, waveforms, or historical data depending on the task at hand.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"5\"\u003e\u003ca href=\"https:\/\/www.indiamart.com\/proddetail\/edan-cx10-multipara-patient-monitor-2859286656430.html\" rel=\"noreferrer\" aria-label=\"4\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eNo-Fan Design for Hygiene and Low Maintenance\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efanless architecture\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e eliminates operating noise and prevents dust from accumulating on internal fan blades and grilles. This supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elower power consumption and reduced dust-related maintenance needs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—advantages in wards and isolation areas where dust and noise are operational concerns\u003c\/span\u003e\u003cspan class=\"\"\u003e. The enclosure is rated for compatibility with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eup to 31 common disinfectants\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, supporting routine wipe-down protocols between patients\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"6\"\u003e\u003ca href=\"https:\/\/www.edan.com\/Uploads\/20240730030130_658046.pdf#1#1\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eiSEAP™ ECG: Up to 33 Arrhythmia Types with SEMIP™ Analysis\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eiSEAP™ ECG algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e detects \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eup to 33 arrhythmia types\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and incorporates \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSEMIP™ analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for ECG evaluation\u003c\/span\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMulti-level analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is designed to improve cardiac sensitivity while reducing false alarms, supporting clinician trust in the displayed measurements\u003c\/span\u003e\u003cspan class=\"\"\u003e. The monitor supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estandard 3\/5-lead ECG with optional 6\/12-lead\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for expanded cardiac evaluation.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"8\"\u003e\u003ca href=\"https:\/\/www.edan.com\/Uploads\/20240730030130_658046.pdf#1#1\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.indiamart.com\/proddetail\/edan-cx10-multipara-patient-monitor-2859286656430.html\" rel=\"noreferrer\" aria-label=\"4\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eiFAST™ NIBP: Rapid Measurement in Approximately 15 Seconds\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eiFAST™ algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is designed to complete blood pressure measurement in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapproximately 15 seconds\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, reducing cuff inflation time during routine rounds\u003c\/span\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eiCUFS™ algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e manages \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esmart adaptive cuff inflation and deflation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with cuff size identification, and is intended for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadult, pediatric, and neonatal patients\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emaintenance mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports routine NIBP calibration and cleaning.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"10\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-b-cardiovascular-diagnostic-devices\/MHX\/K250179?doc=summary\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.indiamart.com\/proddetail\/edan-cx10-multipara-patient-monitor-2859286656430.html\" rel=\"noreferrer\" aria-label=\"4\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eiMAT™ SpO₂: Motion and Low-Perfusion Performance\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eEDAN's \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eiMAT™ SpO₂ algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emotion resistance\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elow-perfusion performance\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePerfusion Index (PI) reference reading\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e that reflects perfusion changes at the sensor site\u003c\/span\u003e\u003cspan class=\"\"\u003e. The CX10 supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esimultaneous SpO₂ and NIBP measurement on the same limb\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, which can simplify setup in patients with limited access sites\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"12\"\u003e\u003ca href=\"https:\/\/www.edan.com\/Uploads\/20240730030130_658046.pdf#1#1\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.indiamart.com\/proddetail\/edan-cx10-multipara-patient-monitor-2859286656430.html\" rel=\"noreferrer\" aria-label=\"4\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eOptional EDAN G2 Sidestream CO₂ with iCARB™\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eWhen configured with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEDAN G2 CO₂ module\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, the CX10 adds \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esidestream capnography\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eiCARB™ algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for intelligent CO₂ pseudo-wave identification, a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esuperior water trap design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esampling rate as low as 50 mL\/min\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. This makes the CX10 suitable for procedural sedation and anesthesia support where EtCO₂ trends are part of the monitoring workflow.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"14\"\u003e\u003ca href=\"https:\/\/www.edan.com\/Uploads\/20240730030130_658046.pdf#1#1\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eExpandable to IBP and Cardiac Output\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe CX10 supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional 2-channel IBP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecardiac output (C.O.)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , allowing the same device to serve higher-acuity patients when hemodynamic monitoring is required\u003c\/span\u003e\u003cspan class=\"\"\u003e. This expansion path is shared across the CX series, so departments can standardize on one interface and accessory ecosystem from ward to higher-acuity areas.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"15\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-b-cardiovascular-diagnostic-devices\/MHX\/K250179?doc=summary\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eData Review, Storage, and Connectivity\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe CX10 stores \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e1,200 NIBP records, 48 hours of 1-second trend data (or 240 hours at 1-minute resolution), 1,000 alarm events, and 48 hours of full-disclosure waveforms\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWi-Fi (2.4\/5 GHz), HDMI, and a multifunction interface\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e support integration with central monitoring stations and hospital networks, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional thermal printer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provides hard-copy documentation\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"16\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-b-cardiovascular-diagnostic-devices\/MHX\/K250179?doc=summary\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e10.1-inch color TFT touchscreen, 1024 × 600; gesture operation; rotary knob\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eStandard Parameters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e3\/5-lead ECG, RESP, EDAN SpO₂, EDAN NIBP, PR, 1-channel TEMP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOptional Parameters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e6\/12-lead ECG, 2-channel TEMP, 2-channel IBP, EDAN G2 sidestream CO₂, Cardiac Output (C.O.), thermal printer, built-in Wi-Fi, multifunction interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECG Algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eiSEAP™ with up to 33 arrhythmia types; SEMIP™ analysis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNIBP Algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eiFAST™ (~15-second measurement); iCUFS™ with smart adaptive inflation and deflation; intended for adult, pediatric, and neonatal patients\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSpO₂ Algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eiMAT™ with motion and low-perfusion resistance; Perfusion Index (PI) reference; same-limb SpO₂ + NIBP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCO₂ Technology (Optional)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eEDAN G2 sidestream; iCARB™ pseudo-wave identification; water trap; ~50 mL\/min sampling rate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eData Storage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1,200 NIBP; 48 h @ 1 s \/ 240 h @ 1 min trend; 1,000 alarm events; 48 h @ 1 s full disclosure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eConnectivity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eWi-Fi (2.4\/5 GHz, IEEE 802.11a\/b\/g\/n); HDMI; multifunction interface; central station compatible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCooling\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eNo-fan design\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisinfectant Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eUp to 31 common medical disinfectants\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e100–240 V AC or rechargeable Li-ion battery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Patient Types\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eAdult, pediatric, neonatal (arrhythmia\/ST analysis for adults; C.O. for adults)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"17\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-b-cardiovascular-diagnostic-devices\/MHX\/K250179?doc=summary\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Use\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eMulti-parameter vital-signs monitoring in hospital environments by trained healthcare professionals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the EDAN CX10?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eClinical Challenge\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eCX10 Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed a monitoring platform that scales across departments\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSame algorithms and interface as CX12\/CX15, in the smallest 10.1-inch CX enclosure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTouch-only interfaces can slow interaction in some workflows\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eTouchscreen + rotary knob for alternative control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFrequent cleaning between patients\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eNo-fan design; enclosure compatible with up to 31 disinfectants\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRoutine NIBP rounds take time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eiFAST™ algorithm designed to complete measurement in approximately 15 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMotion and low perfusion compromise SpO₂\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eiMAT™ algorithm with motion and low-perfusion resistance, plus PI reference\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed to add capnography without replacing the monitor\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eEDAN G2 sidestream CO₂ with iCARB™ and ~50 mL\/min sampling rate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed hemodynamic monitoring for higher-acuity patients\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eOptional 2-channel IBP and cardiac output (C.O.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eProcedure review without a separate PC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e48 h full disclosure, 1,200 NIBP, 1,000 alarms stored on-board; Wi-Fi\/HDMI connectivity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46435527491628,"sku":null,"price":2499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/EDANCX10PatientMonitor.png?v=1792578843","url":"https:\/\/www.globalhealthcaremedical.com\/products\/edan-cx10-patient-monitor","provider":"Global Healthcare Medical","version":"1.0","type":"link"}