{"product_id":"edan-h80s-5-part-hematology-analyzer","title":"EDAN H80S 5‑Part Hematology Analyzer","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEDAN H80S\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high‑throughput, 5‑part differential hematology analyzer engineered to reduce laboratory workload through advanced laser‑based cell analysis, streamlined automation, and an intuitive user interface\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e. With a throughput of\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e80 samples per hour\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, continuous loading of venous and capillary tubes, and\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etri‑angle semiconductor laser\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edifferentiation, the H80S delivers reliable, accurate results for both routine and complex samples\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe H80S features a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ededicated BASO channel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNRBC flagging\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewith quantification, and comprehensive\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3D \u0026amp; 2D scattergram\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eanalysis\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e. Its large\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12.1‑inch color touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewith a user‑oriented interface ensures fast navigation and simplified workflow for routine operations\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e. Cost‑effective reagents with\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etwo‑year shelf life and 90‑day onboard stability\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, combined with simplified maintenance, make the H80S a powerful solution for modern mid‑volume laboratories seeking efficiency and diagnostic confidence\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eTri‑Angle Semiconductor Laser Technology for Superior WBC Differentiation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe H80S utilizes\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etri‑angle semiconductor laser flow cytometry\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efor WBC, DIFF, and BASO counting\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e. Three different angle scatters reflect comprehensive information about cells\u003c\/span\u003e\u003ca href=\"https:\/\/www.edan.com\/product\/m\/IVD_Hematology_H80S.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLow scatter (LS, \u0026lt;10°)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– reflects cell volume\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMiddle scatter (MS, 10°–20°)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– reflects cell complexity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHigh scatter (HS, \u0026gt;20°)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– reflects cell granularity\u003c\/span\u003e\u003ca href=\"https:\/\/www.edan.com\/product\/m\/IVD_Hematology_H80S.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThis three‑angle approach provides detailed information on cell size, complexity, and granularity, improving separation of WBC subpopulations and enhancing detection in abnormal or aging samples\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eDedicated BASO Channel for Accurate Basophil Counting\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eBasophils are the least numerous cells and are easily masked by other cell clusters, making them the most difficult to detect\u003c\/span\u003e\u003ca href=\"https:\/\/www.edan.com\/product\/m\/IVD_Hematology_H80S.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e. The H80S features\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ededicated baths and channels\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eto accurately detect basophils\u003c\/span\u003e\u003ca href=\"https:\/\/www.edan.com\/product\/m\/IVD_Hematology_H80S.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e. Cell volume and cell complexity are obtained on the specific basophil scattergram, reducing masking from other cell clusters and ensuring accurate basophil counts\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eNRBC Flagging with Quantification\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eNucleated red blood cells (NRBCs) are similar in size to lymphocytes, often leading to misidentification and erroneous WBC and lymphocyte counts\u003c\/span\u003e\u003ca href=\"https:\/\/www.edan.com\/product\/m\/IVD_Hematology_H80S.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e. The H80S\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatically flags and quantifies NRBCs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, preventing falsely elevated WBC and lymphocyte counts caused by undetected NRBCs\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.edan.com\/product\/m\/IVD_Hematology_H80S.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eHigh Eosinophilia Performance\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eEosinophils are significantly elevated during bacterial or parasitic infections\u003c\/span\u003e\u003ca href=\"https:\/\/www.edan.com\/product\/m\/IVD_Hematology_H80S.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e. Combined with laser technology and 3D scattergrams, the H80S can easily handle high eosinophilic samples\u003c\/span\u003e\u003ca href=\"https:\/\/www.edan.com\/product\/m\/IVD_Hematology_H80S.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e. Laser scatter and 3D scattergrams allow precise differentiation of eosinophils, especially in samples with parasitic or bacterial infections\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e3D \u0026amp; 2D Scattergram Analysis for Enhanced Visualization\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe H80S provides\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e1 three‑dimensional scattergram (DIFF)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e4 two‑dimensional scattergrams (3× DIFF, 1× BASO)\u003c\/span\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/www.edan.com\/product\/m\/IVD_Hematology_H80S.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e. The rotating 3D scattergram facilitates observation of each cell cluster, making results more reliable for both normal and abnormal samples\u003c\/span\u003e\u003ca href=\"https:\/\/www.edan.com\/product\/m\/IVD_Hematology_H80S.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e. In abnormal and aging samples, eosinophils are often obscured by other normal cells—by using MS in conjunction with HS to observe contents, granularities, and nuclei, the 3D scattergram can more accurately differentiate eosinophils\u003c\/span\u003e\u003ca href=\"https:\/\/www.edan.com\/product\/m\/IVD_Hematology_H80S.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eHigh Throughput \u0026amp; Flexible Sampling\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eThroughput:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e80 samples per hour\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eContinuous loading\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eof venous and capillary tubes\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSample Volume:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e23 μL (whole blood \/ capillary), 20 μL (pre‑diluted)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSample Modes:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhole blood, capillary whole blood, and pre‑diluted\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCapillary tube loading\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand auto bionic mixing of micro‑volume samples\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eIntuitive Android‑Based Operating System\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe H80S features a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12.1‑inch color touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewith a user‑oriented interface\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e. Fast navigation and simplified workflow make routine operations efficient and effortless\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eCost‑Effective Reagents with Long Shelf Life\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eThree core reagents\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewith\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etwo‑year shelf life\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e90‑day onboard stability\u003c\/span\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRFID reagent authentication and tracking\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efor secure reagent management\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-5-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eReduces operational costs while maintaining analytical reliability\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSimplified Maintenance\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTest‑quantity‑based maintenance reminders\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—minimal daily tasks\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eAutomated micro‑mixing for consistent sample preparation\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eVersatile customizable printing templates\u003c\/span\u003e\u003ca href=\"https:\/\/mobile.labmedica.es\/expo\/product\/18883\/5-part-hematology-analyzer-model-h80-s\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eComprehensive Parameters\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe H80S delivers\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e25 reportable parameters\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e9 research parameters\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eCategory\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eParameters\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eReportable (25)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eWBC, LYM%, LYM#, MON%, MON#, NEU%, NEU#, EOS%, EOS#, BAS%, BAS#, RBC, HGB, HCT, MCV, RDW‑CV, RDW‑SD, MCH, MCHC, PLT, MPV, PCT, PDW, P‑LCR, P‑LCC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eResearch (9)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eALY%, ALY#, LIC%, LIC#, NRBC%, NRBC#, NLR, PLR, MLR\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHistograms\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eWBC, RBC, PLT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eScattergrams\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e4× 2D (3× DIFF, 1× BASO) + 1× 3D (DIFF)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMeasurement Principles\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eTri‑angle semiconductor laser flow cytometry (WBC, DIFF, BASO); Electrical impedance (RBC, PLT); Cyanide‑free colorimetric (HGB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eParameters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e25 reportable + 9 research = 34 total\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHistograms\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eWBC, RBC, PLT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eScattergrams\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1× 3D (DIFF) + 4× 2D (3× DIFF, 1× BASO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eThroughput\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e80 samples per hour\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSample Volume\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e23 μL (whole blood \/ capillary) \/ 20 μL (pre‑diluted)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSample Modes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eWhole blood, Capillary whole blood, Pre‑diluted\u003c\/span\u003e\u003ca href=\"https:\/\/web.vdia.cz\/en\/h80s-with-autoloader\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12.1‑inch color touchscreen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eData Storage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e100,000 results + 60 QC files\u003c\/span\u003e\u003ca href=\"https:\/\/www.edan.com\/product\/m\/IVD_Hematology_H80S.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eConnectivity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eBi‑directional LIS\/HIS, HL7 protocol\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eReagents\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eHD600 Diluent (20L); HL610, HL620 Lyse (500mL\/1000mL); HC310\/HC600 Cleaner (50mL)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e100V – 240V, 50\/60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e15°C – 32°C\u003c\/span\u003e\u003ca href=\"https:\/\/www.edan.com\/product\/m\/IVD_Hematology_H80S.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOperating Humidity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e30% RH – 85% RH\u003c\/span\u003e\u003ca href=\"https:\/\/www.edan.com\/product\/m\/IVD_Hematology_H80S.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAir Pressure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e70 kPa – 106 kPa\u003c\/span\u003e\u003ca href=\"https:\/\/www.edan.com\/product\/m\/IVD_Hematology_H80S.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e570mm(W) × 710mm(D) × 595mm(H)\u003c\/span\u003e\u003ca href=\"https:\/\/mobile.labmedica.es\/expo\/product\/18883\/5-part-hematology-analyzer-model-h80-s\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e48 kg\u003c\/span\u003e\u003ca href=\"https:\/\/mobile.labmedica.es\/expo\/product\/18883\/5-part-hematology-analyzer-model-h80-s\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the EDAN H80S?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eLaboratory Challenge\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eH80S Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAccurate WBC differentiation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eTri‑angle semiconductor laser with 3‑angle scatter (volume, complexity, granularity)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBasophil detection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eDedicated BASO channel—the least numerous cells are accurately counted\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNRBC interference\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAutomatic NRBC flagging with quantification—prevents false WBC\/lymphocyte counts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHigh eosinophil samples\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e3D scattergram + laser technology for precise eosinophil differentiation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHigh sample volume\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e80 samples\/hour with continuous loading—walk‑away operation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eComplex operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12.1″ touchscreen with Android‑based, user‑oriented interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLimited sample volume\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eOnly 23 μL whole blood—ideal for pediatric and critical care\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHigh operating costs\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eThree core reagents with 2‑year shelf life, 90‑day onboard stability, RFID management\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMaintenance burden\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eTest‑quantity‑based reminders + automated micro‑mixing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eData management\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e100,000‑result storage + bi‑directional LIS with HL7\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":45984912310316,"sku":null,"price":22999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/H80S5-PartHematologyAnalyzer.jpg?v=1787046388","url":"https:\/\/www.globalhealthcaremedical.com\/products\/edan-h80s-5-part-hematology-analyzer","provider":"Global Healthcare Medical","version":"1.0","type":"link"}