{"product_id":"edan-patient-monitor-xm5-1-plug-in-module","title":"EDAN Patient Monitor XM5-1 Plug-in Module","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEDAN XM5-1 Plug-in Module\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eparameter acquisition engine for EDAN’s iV Series modular patient monitors\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—the module that activates baseline physiological monitoring when docked into an iV12, iV15, or iV17 host monitor. Without an XM module, the iV Series host units do not measure any basic parameters; the XM5-1 supplies the core measurement front-end for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECG, RESP, EDAN SpO₂, EDAN NIBP, PR, and temperature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in a single plug-and-play unit\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"1\"\u003e\u003ca href=\"https:\/\/vigourmedstore.com\/products\/edan-elite-v5-modular-patient-monitor?pr_prod_strat=e5_desc\u0026amp;pr_rec_id=28489097d\u0026amp;pr_rec_pid=9079573971184\u0026amp;pr_ref_pid=9055645204720\u0026amp;pr_seq=uniform\" rel=\"noreferrer\" aria-label=\"22\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2985592\/Edan-Elite-V5.html?page=42#manual\" rel=\"noreferrer\" aria-label=\"24\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe module is designed around the same \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ehot-swappable architecture\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e as the rest of the iV Series module ecosystem: it can be \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eplugged in or removed during monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e without powering down the host monitor, allowing departments to reconfigure a single iV host between different clinical roles—general ward monitoring, transport, or higher-acuity bedside use—by changing the attached module set\u003c\/span\u003e\u003cspan class=\"\"\u003e. The XM5-1 is the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebaseline module\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in that ecosystem; additional standalone modules (IBP, cardiac output, CO₂, anesthetic gas, BIS, NMT, rSO₂, and others) are added alongside it to extend parameter depth.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"3\"\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2985592\/Edan-Elite-V5.html?page=42#manual\" rel=\"noreferrer\" aria-label=\"24\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eStandard parameters supported through the XM5-1 include \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5-lead ECG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with defibrillation protection, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRESP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEDAN SpO₂\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with a reusable adult finger sensor, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEDAN NIBP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with a reusable adult cuff and 3 m tube, and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e2-pin adult skin temperature probe\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The module also supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional 12-lead ECG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNellcor SpO₂\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e configurations, allowing the same physical module to serve departments with different cardiac or oximetry preferences.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe XM5-1 is built for facilities that have standardized on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eiV Series platform\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and need a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebaseline parameter module that can move between host monitors, be swapped during service, or be added to a new iV host without replacing the entire monitoring system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. It shares the iV Series’ \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eno-fan host design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecentral station connectivity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e through the host monitor, and is intended for use by trained clinical personnel in hospital environments. Availability and cleared indications vary by market; confirm local registration before purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eBaseline Parameter Activation for iV Series Hosts\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe XM5-1 is the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003erequired module for basic parameter monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e on EDAN iV Series host monitors. It integrates the measurement front-end for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECG, RESP, EDAN SpO₂, EDAN NIBP, PR, and temperature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e into a single plug-in unit, converting an iV host into a functioning multi-parameter bedside or transport monitor\u003c\/span\u003e\u003cspan class=\"\"\u003e. This architecture allows a facility to purchase iV host monitors once and scale parameter capability through modules rather than replacing entire monitors.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"4\"\u003e\u003ca href=\"https:\/\/vigourmedstore.com\/products\/edan-elite-v5-modular-patient-monitor?pr_prod_strat=e5_desc\u0026amp;pr_rec_id=28489097d\u0026amp;pr_rec_pid=9079573971184\u0026amp;pr_ref_pid=9055645204720\u0026amp;pr_seq=uniform\" rel=\"noreferrer\" aria-label=\"22\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2985592\/Edan-Elite-V5.html?page=42#manual\" rel=\"noreferrer\" aria-label=\"24\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eHot-Swappable Plug-and-Play Design\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe module can be \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eplugged in or unplugged during active monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e without powering down the host monitor. A lever mechanism secures the module in the slot, and an indicator confirms when the module is seated and recognized. This supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003erapid reconfiguration between patients or clinical areas\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and allows a module to be swapped for service without removing the host monitor from the bedside\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"6\"\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2985592\/Edan-Elite-V5.html?page=42#manual\" rel=\"noreferrer\" aria-label=\"24\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eStandard Vital-Signs Parameter Set\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe XM5-1 ships with a complete baseline accessory set: \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5-lead snap ECG cable (IEC, defibrillation-proof)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ereusable adult SpO₂ finger sensor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ereusable adult NIBP cuff (27–35 cm) with 3 m tube\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e2-pin adult skin temperature probe\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. This means the module arrives ready for adult vital-signs monitoring without requiring separate accessory purchases for basic use.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eOptional 12-Lead ECG and Nellcor SpO₂ Configuration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe XM5-1 supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional 12-lead ECG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with a 10-lead trunk cable and limb wires, enabling expanded cardiac evaluation when the clinical need arises. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNellcor SpO₂ option\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is also available, allowing departments that have standardized on Nellcor sensors to use the iV Series platform without changing oximetry consumables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eExpandable Within the iV Module Ecosystem\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe XM5-1 is the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efoundation module\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in the iV Series module rack. Additional standalone modules—\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIBP, IBP + cardiac output, ICG, sidestream or mainstream CO₂, respiratory mechanics, anesthetic gas, BIS, NMT, rSO₂, EEG, and V-Link\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—can be added to the host monitor to extend monitoring depth as clinical requirements change. The XM5-1 supplies the baseline parameters while these modules add specialized measurements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eShared Algorithms and Accessories with EDAN Monitoring Platforms\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe XM5-1 uses EDAN’s monitoring algorithms and accessory ecosystem, including \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eiSEAP™ ECG processing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEDAN SpO₂\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEDAN NIBP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. ECG cables and SpO₂ sensors are shared with other EDAN monitor families where compatible, supporting inventory standardization across departments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eModular Serviceability and Inventory Flexibility\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eBecause the XM5-1 is a separate module, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eservice or replacement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e can be handled at the module level rather than requiring the host monitor to be taken out of service. Facilities can also hold \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003espare XM5-1 modules\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e on hand to maintain monitoring uptime if a module requires attention, while the iV host remains available for use with a replacement module.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eModule Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePlug-in parameter acquisition module for EDAN iV Series patient monitors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCompatible Host Monitors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eEDAN iV12, iV15, iV17 (iV Series modular patient monitors)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eStandard Parameters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eECG (5-lead), RESP, EDAN SpO₂, EDAN NIBP, PR, TEMP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECG Configuration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e5-lead snap, defibrillation-proof, IEC; optional 12-lead ECG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSpO₂ Configuration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eEDAN SpO₂ standard; Nellcor SpO₂ optional\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNIBP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eEDAN NIBP with reusable adult cuff (27–35 cm) and 3 m tube\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTemperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e2-pin adult skin probe (10K\/25°C) standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eStandard Accessories\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAdult E9 NIBP cuff, NIBP tube (3 m), adult skin temp probe, adult SpO₂ finger sensor (2.5 m), 5-lead snap ECG cable (IEC, defib, 3.4 m)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOptional Configurations\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12-lead ECG (trunk cable + limb wires); Nellcor SpO₂ module and sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInstallation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePlug-and-play into XM module slot on the left side of the iV host monitor; hot-swappable during monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHost Connectivity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eCentral station and HIS\/EMR connectivity provided through the iV host monitor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCooling\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePassive; host monitor operates with no-fan design\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Use\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eParameter acquisition for multi-parameter monitoring in hospital environments by trained clinical personnel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRegulatory Status\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAvailability and cleared indications vary by market; contact EDAN for local registration information\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the EDAN XM5-1 Plug-in Module?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eClinical or Operational Challenge\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eXM5-1 Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eiV Series host monitors require a module for basic parameters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eXM5-1 supplies the baseline measurement front-end for ECG, RESP, SpO₂, NIBP, PR, and TEMP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed to reconfigure monitors between patients or departments\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eHot-swappable module can be exchanged during monitoring without powering down the host\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed to scale from basic vital signs to advanced monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eXM5-1 serves as the foundation module; additional standalone modules add IBP, CO₂, AG, BIS, NMT, and more\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed 12-lead ECG or Nellcor SpO₂ without a different host monitor\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eOptional 12-lead ECG and Nellcor SpO₂ configurations are available on the same module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed to reduce monitor downtime during service\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eModule-level serviceability allows a spare XM5-1 to be swapped in while the host remains at the bedside\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed to standardize accessories across EDAN monitor families\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eXM5-1 uses shared EDAN ECG, SpO₂, NIBP, and temperature accessories where compatible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed flexible module inventory across a department\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eA single XM5-1 module can be moved between compatible iV host monitors as demand changes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46436431593516,"sku":null,"price":1999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/EDANPatientMonitorXM5-1Plug-inModule.png?v=1792589177","url":"https:\/\/www.globalhealthcaremedical.com\/products\/edan-patient-monitor-xm5-1-plug-in-module","provider":"Global Healthcare Medical","version":"1.0","type":"link"}