{"product_id":"edan-se-1200-express-electrocardiograph","title":"EDAN SE-1200 Express Electrocardiograph","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEDAN SE-1200 Express\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12-channel resting electrocardiograph\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e designed for hospitals, clinics, and diagnostic centers that need \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esimultaneous 12-lead acquisition, integrated thermal printing, and network-ready data management\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in a single portable device. It pairs an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e8-inch high-resolution color touchscreen (800 × 600 dots)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efull alphanumeric keyboard\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, giving clinicians both touch and physical input options during acquisition and review\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"1\"\u003e\u003ca href=\"https:\/\/www.somatechnology.com\/pdfFiles\/Edan-SE-1200-ECG.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"12\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1200 Express is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA-cleared as part of the SE-12 Series under 510(k) K102830 (December 2, 2010)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass II, 21 CFR 870.2340, Product Code DPS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The SE-12 Series includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efour models: SE-12, SE-1200, SE-12 Express, and SE-1200 Express\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, sharing the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esame ECG board, power supply board, and main control board\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The cleared intended use covers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eacquisition of ECG signals from adult and pediatric patients through body surface ECG electrodes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, for use \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ein hospitals or healthcare facilities by doctors and trained healthcare professionals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Critically, the cleared labeling states that the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECG with measurements and interpretive statements is offered to clinicians on an advisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—it is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintended to help users analyze and diagnose heart disease, but does not replace professional judgment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The FDA summary states \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e“No clinical data provided”\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; substantial equivalence was supported by \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esoftware testing, risk analysis, safety testing, and environmental testing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"2\"\u003e\u003ca href=\"http:\/\/510k.innolitics.com\/device\/K102830\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe signal chain includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24-bit A\/D converter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esampling rate up to 64,000\/sec\/channel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCMRR ≥ 140 dB (AC on) \/ ≥ 123 dB (AC off)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efrequency response referenced as 0.05–150 Hz in distributor documentation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The device acquires \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eall 12 leads simultaneously\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and prints \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12-channel reports on a 216 mm-wide thermal printer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with paper speeds of \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5, 6.25, 10, 12.5, 25, or 50 mm\/s\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSEMIP software\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provides automatic measurements and interpretation, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGlasgow interpretation referenced as built-in\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in EDAN product literature, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esignal quality indication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for at-a-glance electrode confidence\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"6\"\u003e\u003ca href=\"http:\/\/510k.innolitics.com\/device\/K102830\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.edan.com\/Uploads\/20240903020857_481976.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"6\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.somatechnology.com\/pdfFiles\/Edan-SE-1200-ECG.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"12\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1200 Express stores \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eup to 800 ECG records internally\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, expandable via USB flash disk. Connectivity covers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLAN, built-in Wi-Fi (optional), and RS-232\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePDF, SCP, FDA-XML, and DICOM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e report export where configured. The optional \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSE-1515 Data Management System\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebi-directional communication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with hospital systems via \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDICOM Worklist, HL7, and GDT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e protocols. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e14.8 V lithium-ion battery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is available in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e2500 mAh or 5000 mAh configurations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, supporting \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapproximately 1.5 or 2.5 hours of continuous printing, or 300 or 450 ECG reports\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e respectively. The device weighs \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapproximately 5 kg (excluding paper and battery)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and measures \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e420 × 330 × 105 mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"11\"\u003e\u003ca href=\"https:\/\/www.edan.com\/Uploads\/20240903020857_481976.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"6\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.somatechnology.com\/pdfFiles\/Edan-SE-1200-ECG.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"12\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1200 Express carries \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE marking as a Class IIa medical device\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e under \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEU MDR 2017\/745\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with the SE-12 Series covered under \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTÜV SÜD CE 0123\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. It is classified as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass I with internal power supply, Type CF, defibrillation-proof\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and is designed to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIEC 60601-1, IEC 60601-1-2, and IEC 60601-2-25\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1200 Express is built for facilities that need \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ea proven, FDA-cleared 12-channel ECG platform with a large touchscreen, simultaneous 12-lead acquisition, 12-channel printing, and flexible network connectivity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—without the footprint of a larger workstation, and with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBasic version available\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for budget-conscious departments\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"14\"\u003e\u003ca href=\"https:\/\/www.edan.com\/Uploads\/20240903020857_481976.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"6\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e8-Inch Color Touchscreen with Full Keyboard\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e8-inch high-resolution color touchscreen (800 × 600 dots)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e displays all 12 waveforms simultaneously and supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etouch interaction with one-touch operation and age\/gender shortcuts\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for faster workflow\u003c\/span\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efull alphanumeric keyboard\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e remains available for efficient patient information entry and direct commands, reducing reliance on on-screen menus during high-throughput ECG sessions.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"15\"\u003e\u003ca href=\"https:\/\/www.edan.com\/Uploads\/20240903020857_481976.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"6\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.somatechnology.com\/pdfFiles\/Edan-SE-1200-ECG.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"12\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSimultaneous 12-Lead Acquisition with 24-Bit Signal Chain\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1200 Express acquires \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eall 12 leads simultaneously\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e through body surface electrodes. The signal chain includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24-bit A\/D converter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esampling rate up to 64,000\/sec\/channel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCMRR ≥ 140 dB (AC on) \/ ≥ 123 dB (AC off)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efrequency response referenced as 0.05–150 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eComprehensive digital filters\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e address baseline drift, AC interference, and EMG noise, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECG signal quality indication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supporting electrode confidence before recording\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"17\"\u003e\u003ca href=\"http:\/\/510k.innolitics.com\/device\/K102830\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.edan.com\/Uploads\/20240903020857_481976.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"6\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eBuilt-In 12-Channel Thermal Printer with A4 Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintegrated high-resolution thermal recorder\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e prints \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12-channel reports on normal thermal paper or A4-size fax paper\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with paper speeds of \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5, 6.25, 10, 12.5, 25, or 50 mm\/s\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eExternal USB printer support\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is also available for standard office printing when required\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"20\"\u003e\u003ca href=\"https:\/\/www.edan.com\/Uploads\/20240903020857_481976.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"6\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.somatechnology.com\/pdfFiles\/Edan-SE-1200-ECG.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"12\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSEMIP and Glasgow Interpretation, Advisory Only\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1200 Express includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic ECG measurements and interpretation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, processed by the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSEMIP algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGlasgow interpretation referenced as built-in\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in EDAN product literature. Per the cleared labeling under \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eK102830\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECG with measurements and interpretive statements is offered on an advisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—it supports, but does not replace, clinician analysis and diagnosis. EDAN documentation also notes that interpretation has been \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etested with CSE\/AHA\/MIT databases\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"22\"\u003e\u003ca href=\"http:\/\/510k.innolitics.com\/device\/K102830\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.edan.com\/Uploads\/20240903020857_481976.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"6\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e120-Second Waveform Freezing and Review\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe device supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e120 seconds of real-time waveform freezing and review\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, allowing the clinician to pause and examine a captured segment before printing or storing. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eExtended printing is triggered when arrhythmia is detected\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, supporting further rhythm analysis without manual intervention\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"24\"\u003e\u003ca href=\"https:\/\/www.edan.com\/Uploads\/20240903020857_481976.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"6\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e800 ECG Internal Storage with LAN\/Wi-Fi and DICOM\/HL7\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1200 Express stores \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eup to 800 ECG records internally\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eUSB flash disk expansion\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Data can be transmitted to a PC via \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLAN, built-in Wi-Fi (optional), or RS-232\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and reports can be exported in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePDF, SCP, FDA-XML, and DICOM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e formats. The optional \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSE-1515 Data Management System\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebi-directional communication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and access to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEMR\/HIS\/PACS\/GDT-based systems\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e via \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDICOM Worklist, HL7, and GDT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"25\"\u003e\u003ca href=\"https:\/\/www.edan.com\/Uploads\/20240903020857_481976.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"6\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.somatechnology.com\/pdfFiles\/Edan-SE-1200-ECG.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"12\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eRechargeable Li-Ion Battery with Two Capacity Options\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e14.8 V lithium-ion battery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is available in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e2500 mAh or 5000 mAh configurations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e2500 mAh pack\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapproximately 1.5 hours of continuous printing or 300 ECG reports\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5000 mAh pack\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapproximately 2.5 hours or 450 reports\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The device can also operate on \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAC mains (100–240 V, 50\/60 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSafety Classification: Class I, Type CF, Defibrillation-Proof\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1200 Express is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass I with internal power supply, Type CF, and defibrillation-proof\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCF (Cardiac Floating)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e applied part indicates a high degree of patient isolation suitable for direct cardiac contact applications, and the device is designed to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIEC 60601-1, IEC 60601-1-2, and IEC 60601-2-25\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e standards\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"29\"\u003e\u003ca href=\"https:\/\/www.edan.com\/Uploads\/20240903020857_481976.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"6\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eRegulatory Status: FDA-Cleared and CE IIa\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1200 Express is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA-cleared under K102830 (Class II, DPS)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE-marked as a Class IIa medical device under EU MDR 2017\/745\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with the SE-12 Series covered under \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTÜV SÜD CE 0123\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Availability and cleared claims vary by market; confirm local registration and labeling before purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDevice Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12-channel resting electrocardiograph\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA Clearance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eK102830 (December 2, 2010); Class II, 21 CFR 870.2340, Product Code DPS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAcquisition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12 leads simultaneous via body surface electrodes; 12-channel printing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e8-inch color touchscreen, 800 × 600 dots; alphanumeric keyboard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eA\/D Converter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e24-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSampling Rate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eUp to 64,000\/sec\/channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCMRR\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≥ 140 dB (AC On); ≥ 123 dB (AC Off)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFrequency Response\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.05–150 Hz (distributor documentation); 0.01–300 Hz also referenced for the SE-12 Series platform\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFilters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eComprehensive AC, DFT, EMG, and low-pass digital filters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInterpretation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eSEMIP algorithm; Glasgow interpretation referenced as built-in; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e per cleared labeling\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWaveform Review\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e120-second real-time freezing and review; extended printing on arrhythmia detection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInternal Storage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eUp to 800 ECG records; USB flash disk expansion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRecorder\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eBuilt-in thermal dot-matrix; 216 mm wide; 12-channel; 210 mm × 295 mm Z-fold or 210 mm × 30 m roll; 5–50 mm\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eExternal Printer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eUSB printer support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eData Transfer \/ Export\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLAN; Wi-Fi (optional); RS-232; PDF, SCP, FDA-XML, DICOM where configured\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eData Management\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eOptional SE-1515; bi-directional communication; DICOM Worklist\/HL7\/GDT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBattery\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e14.8 V Li-ion; 2500 mAh (~1.5 h printing \/ 300 reports) or 5000 mAh (~2.5 h printing \/ 450 reports)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAC 100–240 V, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDimensions \/ Weight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e420 × 330 × 105 mm; approximately 5 kg (excluding paper and battery)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSafety Classification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eClass I, internal power supply, Type CF, defibrillation-proof\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSafety Standards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eIEC 60601-1; IEC 60601-1-2; IEC 60601-2-25\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE Marking\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eClass IIa, EU MDR 2017\/745; TÜV SÜD CE 0123 (SE-12 Series platform)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Patient Population\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAdult and pediatric patients\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Use\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eAcquisition of ECG signals via body surface electrodes to help analyze and diagnose heart disease in hospitals or healthcare facilities by doctors and trained healthcare professionals; ECG with measurements and interpretive statements offered on an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the EDAN SE-1200 Express?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eClinical or Operational Challenge\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSE-1200 Express Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed FDA-cleared 12-channel ECG with a large touchscreen and keyboard\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSE-1200 Express covered under K102830; 8-inch color touchscreen (800 × 600) with full alphanumeric keyboard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed simultaneous 12-lead acquisition with 12-channel printing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12-lead simultaneous acquisition; 12-channel reports on 216 mm thermal paper; A4 fax paper support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed high-resolution signal acquisition for routine and pediatric ECG\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e24-bit A\/D; up to 64,000\/sec\/channel; CMRR ≥ 140 dB; comprehensive digital filters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed on-screen interpretation support with clear labeling\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eSEMIP and Glasgow interpretation referenced; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e per cleared labeling; CSE\/AHA\/MIT database testing referenced\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed extended waveform review and arrhythmia-triggered printing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e120-second waveform freezing; extended printing on arrhythmia detection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed HIS\/EMR\/PACS integration and paperless workflow\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLAN\/Wi-Fi\/RS-232; PDF\/SCP\/FDA-XML\/DICOM export; optional SE-1515 for DICOM Worklist\/HL7\/GDT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed substantial internal storage for daily ECG volume\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eUp to 800 ECG records; USB flash disk expansion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed portable use with battery backup\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e2500\/5000 mAh battery options; 1.5\/2.5 h continuous printing or 300\/450 reports; ~5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed FDA and CE MDR regulatory coverage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eFDA K102830; CE IIa (TÜV SÜD CE 0123)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46505000042540,"sku":null,"price":2699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/EdanSE-1200ExpressElectrocardiograph.png?v=1793006037","url":"https:\/\/www.globalhealthcaremedical.com\/products\/edan-se-1200-express-electrocardiograph","provider":"Global Healthcare Medical","version":"1.0","type":"link"}