{"product_id":"edan-se-1201-electrocardiograph","title":"EDAN SE-1201 Electrocardiograph","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEDAN SE-1201\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12-channel resting electrocardiograph\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e designed for hospitals, clinics, and diagnostic centers that need \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esimultaneous 12-lead acquisition, integrated thermal printing, and practical workflow features\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in a portable enclosure. It is the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estandard configuration in the SE-12\/SE-1200\/SE-1201 family\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, positioned below the Pro-series models (SE-1200 Pro and SE-1201 Pro) while retaining the core acquisition and printing capabilities of the platform.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1201 is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA-cleared under 510(k) K120188 (March 16, 2012)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass II electrocardiograph (21 CFR 870.2340, Product Code DPS)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e . The cleared intended use states the device \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eacquires ECG signals from adult and pediatric patients through body surface ECG electrodes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintended for use in hospitals or healthcare facilities by doctors and trained healthcare professionals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Critically, the cleared labeling specifies that \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ethe interpreted ECG with measurements and interpretive statements is offered to clinicians on an advisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—it helps users analyze and diagnose heart disease, but does not replace professional judgment. The FDA summary states \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e“No clinical data provided”\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e ; substantial equivalence was supported by \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebench testing, including software testing, risk analysis, safety testing, and environmental testing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1201 pairs a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e7-inch color touchscreen (800 × 480 resolution)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ealphanumeric keyboard\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for patient information entry. The signal chain includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24-bit A\/D converter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCMRR over 140 dB (AC on)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efrequency response of 0.01–500 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e0.05–150 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e range also referenced in distributor documentation). The device acquires \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eall 12 leads simultaneously\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and prints \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12-channel reports\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e on \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e210 mm × 140 mm folded thermal paper\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e at \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5–50 mm\/s\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSEMIP software\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provides automatic measurements and interpretation, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGlasgow interpretation referenced in EDAN product literature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einterpretation functions tested against CSE\/AHA\/MIT databases\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e per distributor documentation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1201 stores \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eup to 800 ECG records internally\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, expandable via \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eUSB flash disk and SD card\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Connectivity covers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLAN, RS-232, USB, and optional Wi-Fi\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePDF, SCP, FDA-XML, and DICOM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e export formats where configured. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional SE-1515 Data Management System\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDICOM Worklist, HL7, and GDT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e integration for HIS\/EMR\/PACS environments. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e14.8 V, 2500 mAh lithium-ion battery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapproximately 3.5 hours of normal operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eat least 300 reports in AUTO mode (3×4+1R)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , or \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eat least 1.5 hours of continuous printing in MANUAL mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1201 is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE-marked as a Class IIa medical device under EU MDR 2017\/745 (Rule 10)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , certified through \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTÜV SÜD Product Service GmbH (CE 0123)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e under \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCertificate G10 091264 0025 Rev. 01\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (valid until \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e2026-02-17\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e). It is classified as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass I with internal power supply, CF type, and defibrillation-proof\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and is designed to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEN 60601-1, EN 60601-1-2, EN 60601-1-6, EN 60601-2-25, EN ISO 10993-1, EN 62304, and EN 62366-1\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e standards. The device also holds \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChina NMPA registration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1201 is built for facilities that need \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ea proven, FDA-cleared 12-channel ECG platform with a touchscreen, keyboard input, integrated thermal printing, and network-ready data management\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—without the higher price point of the Pro-series models. It is the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estandard configuration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for routine resting ECG workflows in hospital and clinic environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e7-Inch Color Touchscreen with Alphanumeric Keyboard\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e7-inch color touchscreen (800 × 480 resolution)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e displays all 12 waveforms simultaneously and supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etouch interaction\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for waveform review and menu navigation. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ealphanumeric keyboard\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e remains available for efficient patient information entry, reducing reliance on on-screen menus during high-throughput ECG sessions. The display includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003egrid view\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for waveform assessment and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eone-touch operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eage and gender shortcuts\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e to streamline workflow.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSimultaneous 12-Lead Acquisition with 24-Bit Signal Chain\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1201 acquires \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eall 12 leads simultaneously\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e through body surface electrodes. The signal chain includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24-bit A\/D converter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCMRR over 140 dB (AC on)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efrequency response of 0.01–500 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e0.05–150 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e also referenced in distributor documentation). \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eComprehensive digital filters\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e address AC interference, EMG noise, baseline drift, and DFT artifacts, supporting trace readability across different recording environments. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInput impedance is ≥ 50 MΩ (10 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e per China registration specifications, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e≥ 100 MΩ (10 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced in some international documentation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSEMIP and Glasgow Interpretation, Advisory Only\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1201 includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic ECG measurements and interpretation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e processed by the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSEMIP algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGlasgow interpretation referenced in EDAN product literature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Per the cleared labeling under \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eK120188\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECG with measurements and interpretive statements is offered on an advisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—it supports, but does not replace, clinician analysis and diagnosis. Distributor documentation notes that interpretation functions are \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etested against CSE\/AHA\/MIT databases\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and the device supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e120 seconds of real-time waveform freezing and review\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for detailed inspection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eBuilt-In 12-Channel Thermal Printer with A5 Paper Support\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintegrated high-resolution thermal recorder\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e prints \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12-channel reports\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e on \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e210 mm × 140 mm folded paper\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (A5 format) at \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5, 6.25, 10, 12.5, 25, or 50 mm\/s\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eExternal USB printer support\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is available for standard office printing where configured. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePrinting extends automatically when arrhythmia is detected\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, supporting further rhythm analysis without manual intervention.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e800 ECG Internal Storage with USB\/SD Expansion\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1201 stores \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eup to 800 ECG records internally\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eUSB flash disk and SD card expansion\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for extended archiving. Data can be transmitted to a PC via \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLAN, RS-232, or optional Wi-Fi\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and reports can be exported in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePDF, SCP, FDA-XML, and DICOM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e formats. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional SE-1515 Data Management System\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e enables \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebi-directional communication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and access to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEMR\/HIS\/PACS\/GDT-based systems\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e via \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDICOM Worklist, HL7, and GDT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e2500 mAh Battery with 3.5 h Operation or 300 AUTO Reports\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e14.8 V, 2500 mAh lithium-ion battery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapproximately 3.5 hours of normal operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eat least 300 reports in AUTO mode (3×4+1R)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , or \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eat least 1.5 hours of continuous printing in MANUAL mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The device operates on \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAC mains (100–240 V, 50\/60 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e when available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSafety Classification: Class I, CF Type, Defibrillation-Proof\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1201 is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass I with internal power supply, CF type, and defibrillation-proof\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, designed to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEN 60601-1:2006+A1:2013, EN 60601-1-2:2015, EN 60601-1-6:2010+A1:2015, EN 60601-2-25:2015, EN ISO 10993-1:2018, EN 62304:2006+A1:2015, and EN 62366-1:2015\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e standards. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCF (Cardiac Floating)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e applied part indicates a high degree of patient isolation suitable for direct cardiac contact applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eRegulatory Status: FDA K120188, CE MDR Class IIa, China NMPA\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1201 is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA-cleared under K120188 (March 16, 2012)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass II electrocardiograph (DPS)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , with the clearance explicitly covering the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSE-1201\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e model. The device is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE-marked as Class IIa under EU MDR 2017\/745 (Rule 10)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , certified through \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTÜV SÜD CE 0123\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e under \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCertificate G10 091264 0025 Rev. 01\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (valid until \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e2026-02-17\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e). It also holds \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChina NMPA registration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSE-1201 vs. SE-1201 Pro: Clear Differentiation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSE-1201\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estandard configuration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e7-inch touchscreen (800 × 480)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e800-record storage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estandard SEMIP\/Glasgow interpretation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSE-1201 Pro\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (cleared under \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eK222902\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e) features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e10.1-inch touchscreen (1920 × 1200)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e4 kg chassis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e80 kHz dedicated pacemaker detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eexclusive access to the calculated 18-lead report\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The SE-1201 is positioned for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eroutine 12-lead resting ECG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, while the Pro version adds \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvanced pacemaker analysis and derived 18-lead capability\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for higher-acuity settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDevice Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12-channel resting electrocardiograph\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA Clearance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eK120188 (March 16, 2012); Class II, 21 CFR 870.2340, Product Code DPS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE Marking\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eClass IIa, Rule 10, EU MDR 2017\/745; TÜV SÜD CE 0123; Certificate G10 091264 0025 Rev. 01 (valid until 2026-02-17)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChina Registration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e粤械注准20162070997\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAcquisition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12 leads simultaneous via body surface electrodes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e7-inch color LCD touchscreen, 800 × 480 resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInput\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAlphanumeric keyboard; one-touch operation; age\/gender shortcuts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eA\/D Converter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e24-bit; 0.1192 μV\/LSB resolution (per distributor documentation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSampling Rate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e64,000 Hz (distributor documentation); 1,000 Hz also referenced in China registration specifications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCMRR\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e\u0026gt;140 dB (AC on); \u0026gt;123 dB (AC off) per distributor documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFrequency Response\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.01–500 Hz (distributor documentation); 0.05–150 Hz also referenced in China registration specifications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInput Impedance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≥50 MΩ (10 Hz) per China registration; ≥100 MΩ (10 Hz) referenced in some international documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTime Constant\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≥3.2 s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFilters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAC: 50\/60 Hz\/off; EMG: 25\/35\/45 Hz\/off; DFT: 0.01\/0.05\/0.32\/0.67 Hz; Low-pass: 75–350 Hz range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInterpretation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eSEMIP algorithm; Glasgow referenced; CSE\/AHA\/MIT database testing referenced; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e per cleared labeling\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWaveform Review\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e120-second real-time freezing and review; extended printing on arrhythmia detection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInternal Storage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eUp to 800 ECG records; USB flash disk and SD card expansion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRecorder\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eBuilt-in thermal dot-matrix; 210 mm × 140 mm folded paper (A5); 5–50 mm\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eExternal Printer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eUSB printer support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eData Transfer \/ Export\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLAN; RS-232; USB; Wi-Fi (optional); PDF, SCP, FDA-XML, DICOM where configured\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eData Management\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eOptional SE-1515; DICOM Worklist, HL7, GDT integration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBattery\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e14.8 V, 2500 mAh Li-ion; ~3.5 h normal operation; ≥300 AUTO reports (3×4+1R); ≥1.5 h continuous MANUAL printing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAC 100–240 V, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDimensions \/ Weight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e361 × 262 × 135 mm (±2 mm); ≤4.2 kg (excluding paper and battery) per one distributor specification; 5.0 kg also referenced in China registration documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSafety Classification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eClass I, internal power supply, CF type, defibrillation-proof\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSafety Standards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eEN 60601-1:2006+A1:2013; EN 60601-1-2:2015; EN 60601-1-6:2010+A1:2015; EN 60601-2-25:2015; EN ISO 10993-1:2018; EN 62304:2006+A1:2015; EN 62366-1:2015\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Patient Population\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAdult and pediatric patients\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Use\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eAcquisition of ECG signals via body surface electrodes to help analyze and diagnose heart disease in hospitals or healthcare facilities by doctors and trained healthcare professionals; ECG with measurements and interpretive statements offered on an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the EDAN SE-1201?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eClinical or Operational Challenge\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSE-1201 Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed a proven, FDA-cleared 12-channel ECG at a standard configuration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSE-1201 covered under K120188 (2012); 7-inch touchscreen and alphanumeric keyboard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed simultaneous 12-lead acquisition with 12-channel printing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12-lead simultaneous acquisition; 12-channel reports on 210 mm × 140 mm A5 paper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed high-resolution signal acquisition for routine ECG\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e24-bit A\/D; CMRR \u0026gt;140 dB; 0.01–500 Hz bandwidth referenced in distributor documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed on-screen interpretation support with clear labeling\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eSEMIP and Glasgow interpretation referenced; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e per cleared labeling; CSE\/AHA\/MIT database testing referenced\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed extended waveform review and arrhythmia-triggered printing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e120-second waveform freezing; extended printing on arrhythmia detection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed HIS\/EMR\/PACS integration and paperless workflow\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLAN\/RS-232\/USB\/Wi-Fi (optional); PDF\/SCP\/FDA-XML\/DICOM export; optional SE-1515 for DICOM Worklist\/HL7\/GDT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed substantial internal storage for daily ECG volume\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eUp to 800 ECG records; USB flash disk and SD card expansion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed portable use with battery backup\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e2500 mAh battery; ~3.5 h operation or ≥300 AUTO reports; ~4.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed FDA, CE MDR, and China NMPA regulatory coverage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eFDA K120188; CE IIa (TÜV SÜD CE 0123, Certificate G10 091264 0025 Rev. 01); China NMPA \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46505459089452,"sku":null,"price":1999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/EdanSE-1201Electrocardiograph.png?v=1793007623","url":"https:\/\/www.globalhealthcaremedical.com\/products\/edan-se-1201-electrocardiograph","provider":"Global Healthcare Medical","version":"1.0","type":"link"}