{"product_id":"edan-se-1201-pro-electrocardiograph","title":"EDAN SE-1201 Pro Electrocardiograph","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEDAN SE-1201 Pro\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eflagship configuration within EDAN’s SE-1200 Pro\/SE-1201 Pro series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, a pair of \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eportable 12-channel electrocardiographs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e designed for hospitals, clinics, and mobile diagnostic settings. The SE-1201 Pro distinguishes itself from the SE-1200 Pro through a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e10.1-inch full touchscreen (1920 × 1200 resolution)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e4 kg chassis (excluding paper and battery)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , and exclusive access to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecalculated 18-lead report\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e function—an optional software capability that derives a 12-lead→18-lead report for patients over 18 years of age, offered for clinical reference only.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1201 Pro is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA-cleared under 510(k) K222902 (July 28, 2023)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass II electrocardiograph (21 CFR 870.2340, Product Code DPS)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , with the clearance explicitly covering \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eboth the SE-1200 Pro and SE-1201 Pro\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The cleared intended use covers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eacquisition of ECG signals from adult and pediatric patients through body surface ECG electrodes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, for use \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ein hospitals or healthcare facilities by doctors and trained healthcare professionals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einterpreted ECG with measurements and interpretive statements is offered on an advisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The FDA summary states \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e“No clinical data. Bench testing only”\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—substantial equivalence was supported by non-clinical testing against \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIEC 60601-1, IEC 60601-1-2, and IEC 60601-2-25\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, alongside software verification and validation\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"1\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-c-cardiovascular-monitoring-devices\/DPS\/K222902?_x_output_type_b6db407c4_=embedded_pdf#tutorial\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe diagnostic signal chain uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24-bit A\/D converter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e0.1575 μV\/LSB resolution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e64,000 Hz sampling frequency\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e0.01–350 Hz frequency response\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einput impedance ≥ 100 MΩ (10 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ededicated pacemaker detection channel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e samples at \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e80,000 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, capturing pacemaker stimuli as narrow as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e30 μs and as small as 500 μV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with amplitude handling from \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e±500 μV to ±700 mV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and pulse widths from \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e30 μs to 2.0 ms\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"4\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-c-cardiovascular-monitoring-devices\/DPS\/K222902?_x_output_type_b6db407c4_=embedded_pdf#tutorial\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.doccheckshop.eu\/p\/102863-1-se-1201-pro-12-lead-ecg\/#cms-cross-selling-fallback-tab-pane\" rel=\"noreferrer\" aria-label=\"19\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eWhat defines the SE-1201 Pro’s daily workflow is its \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomation suite\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e: the device \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatically records an ECG once signals are adequately sampled\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etimely reminders when lead wires are misconnected or reversed\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003enotifies the clinician when a pacemaker is detected\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. After analysis, a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ered serious-disease alert\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e flags findings that may warrant urgent review. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGesture-based waveform amplification and measurement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eaveraged template analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with manual recalculation of P\/Q\/S\/T points, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eside-by-side report comparison\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e support on-screen clinical review.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eFor interpretation, the SE-1201 Pro includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGlasgow automatic interpretation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSEMIP algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e–based measurements, with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einterpretive statements offered on an advisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e under the FDA labeling. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional calculated 18-lead report\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—exclusive to the SE-1201 Pro within the series—is described in the China registration labeling as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12-lead→18-lead derivation for patients over 18 years of age\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with the derived waveforms \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003enot fully identical to actual measured waveforms\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; if actual posterior\/right-sided waveforms are required, electrodes must be placed and measured directly. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eThe derived report is for clinical reference only and is not to be used as a basis for diagnosis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"6\"\u003e\u003ca href=\"https:\/\/www.huanxiyl.com\/xindiantuji\/223374.html\" rel=\"noreferrer\" aria-label=\"10\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eConnectivity covers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLAN, Wi-Fi, Bluetooth, USB, and an SD card slot\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with report export in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePDF, JPG, BMP, PNG, TIFF, SCP, FDA-XML, and DICOM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e formats where configured\u003c\/span\u003e\u003cspan class=\"\"\u003e. The optional \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSE-1515 Data Management System\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDICOM Worklist, HL7, and GDT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e integration. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e14.8 V, 2500 mAh lithium-ion battery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapproximately 4 hours in AUTO mode (one report every 2 minutes) or 2 hours in MANUAL mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003echarge time ≤ 3 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"7\"\u003e\u003ca href=\"https:\/\/novamedicasas.com\/wp-content\/uploads\/2026\/08\/SE-1201-PRO.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.doccheckshop.eu\/p\/102863-1-se-1201-pro-12-lead-ecg\/#cms-cross-selling-fallback-tab-pane\" rel=\"noreferrer\" aria-label=\"19\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.de\/manual\/990912\/Edan-Se-1200-Pro.html?page=75\" rel=\"noreferrer\" aria-label=\"33\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1201 Pro is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE-marked as a Class IIa medical device under EU MDR 2017\/745\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, covered under \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTÜV SÜD Product Service GmbH (CE 0123)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e EU MDR Quality Management System Certificate \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eG10 091264 0025 Rev. 01\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, which covers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass IIa and IIb devices under Annex IX Chapters I and III\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. It is classified as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass I with internal power supply, CF type, and defibrillation-proof\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, designed to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIEC 60601-1, IEC 60601-1-2, and IEC 60601-2-25\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e standards\u003c\/span\u003e\u003cspan class=\"\"\u003e. The device also holds \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChina NMPA registration (粤械注准20222071820)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e \u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"11\"\u003e\u003ca href=\"https:\/\/www.huanxiyl.com\/xindiantuji\/223374.html\" rel=\"noreferrer\" aria-label=\"10\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/novamedicasas.com\/wp-content\/uploads\/2026\/08\/SE-1201-PRO.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1201 Pro is built for facilities that need \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ea portable, FDA-cleared 12-channel ECG platform with a large high-resolution touchscreen, advanced workflow automation, high-resolution pacemaker analysis, and exclusive access to the calculated 18-lead report\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—without the weight or footprint of a conventional ECG cart.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e10.1-Inch Full Touchscreen (1920 × 1200) with 25° Rotation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1201 Pro features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e10.1-inch full LCD touchscreen with 1920 × 1200 resolution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, providing clear visualization of all 12 leads simultaneously\u003c\/span\u003e\u003cspan class=\"\"\u003e. The display \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003erotates 25 degrees clockwise\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, allowing the clinician to adjust the viewing angle for comfortable operation from different positions around the patient\u003c\/span\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ewaterproof surface\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports routine disinfection between patients\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"13\"\u003e\u003ca href=\"https:\/\/novamedicasas.com\/wp-content\/uploads\/2026\/08\/SE-1201-PRO.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.doccheckshop.eu\/p\/102863-1-se-1201-pro-12-lead-ecg\/#cms-cross-selling-fallback-tab-pane\" rel=\"noreferrer\" aria-label=\"19\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e4 kg Chassis with Compact Footprint\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eAt \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e4 kg (excluding paper and battery)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e298 × 258 × 82.5 mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, the SE-1201 Pro is designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esingle-hand transport between examination rooms, wards, and emergency departments\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional rolling stand (MT-310)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e enables cart-based deployment when needed, while the compact enclosure houses the full acquisition front-end, touchscreen, thermal printer, and battery.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"17\"\u003e\u003ca href=\"https:\/\/novamedicasas.com\/wp-content\/uploads\/2026\/08\/SE-1201-PRO.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.doccheckshop.eu\/p\/102863-1-se-1201-pro-12-lead-ecg\/#cms-cross-selling-fallback-tab-pane\" rel=\"noreferrer\" aria-label=\"19\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eAI-Assisted Workflow: Auto-Recording, Pacemaker Alerts, and Electrode Hints\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1201 Pro automates several steps that traditionally require manual attention. The device \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatically records an ECG once signal quality is adequate\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ealerts the user when lead wires are misconnected or reversed\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003enotifies when a pacemaker is detected\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. After analysis, a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ered serious-disease notification\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e draws attention to ECGs that may warrant urgent review. These functions are presented as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eworkflow aids\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; they do not replace clinician judgment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e80 kHz Pacemaker Detection with 30 μs \/ 500 μV Sensitivity\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ededicated pacemaker detection channel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e samples at \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e80,000 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, separate from the 64 kHz diagnostic ECG path. The pacemaker circuit captures stimuli as narrow as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e30 μs and as small as 500 μV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with amplitude handling from \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e±500 μV to ±700 mV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and pulse widths from \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e30 μs to 2.0 ms\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. This configuration supports visualization and marking of pacemaker stimuli that may be difficult to resolve at standard ECG sampling rates.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"19\"\u003e\u003ca href=\"https:\/\/www.doccheckshop.eu\/p\/102863-1-se-1201-pro-12-lead-ecg\/#cms-cross-selling-fallback-tab-pane\" rel=\"noreferrer\" aria-label=\"19\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eCalculated 18-Lead Report (SE-1201 Pro Exclusive)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional calculated 18-lead report\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e derives an 18-lead report from a standard 12-lead acquisition for patients \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eover 18 years of age\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Per the China registration labeling, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ederived waveforms are not fully identical to actual measured waveforms\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; if actual posterior or right-sided waveforms are required, electrodes must be placed at the corresponding sites and measured directly. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eThe calculated report is for clinical reference only and is not to be used as a basis for diagnosis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. This function is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eexclusive to the SE-1201 Pro\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and is not available on the SE-1200 Pro.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"20\"\u003e\u003ca href=\"https:\/\/www.huanxiyl.com\/xindiantuji\/223374.html\" rel=\"noreferrer\" aria-label=\"10\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e24-Bit Signal Chain with 0.01–350 Hz Frequency Response and 140 dB CMRR\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe diagnostic signal path uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24-bit A\/D converter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e64,000 Hz sampling frequency\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e0.01–350 Hz frequency response\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einput impedance ≥ 100 MΩ (10 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAC, DFT, EMG, and low-pass digital filters\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e are selectable (AC: 50\/60 Hz\/off; DFT: 0.01\/0.05\/0.32\/0.67 Hz; EMG: 25\/35\/45 Hz\/off; low-pass: 50–300 Hz range) to address baseline drift, interference, and noise across different recording environments\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"21\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-c-cardiovascular-monitoring-devices\/DPS\/K222902?_x_output_type_b6db407c4_=embedded_pdf#tutorial\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.doccheckshop.eu\/p\/102863-1-se-1201-pro-12-lead-ecg\/#cms-cross-selling-fallback-tab-pane\" rel=\"noreferrer\" aria-label=\"19\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eGlasgow and SEMIP Interpretation, Advisory Only\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1201 Pro includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGlasgow automatic interpretation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSEMIP algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e–based analysis, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emeasurements and interpretive statements offered on an advisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e under the FDA labeling\u003c\/span\u003e\u003cspan class=\"\"\u003e. The device supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003egesture-based amplification and measurement of any waveform segment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eaveraged template analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with manual recalculation of P, Q, S, and T points, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eside-by-side report comparison\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for longitudinal review.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"23\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-c-cardiovascular-monitoring-devices\/DPS\/K222902?_x_output_type_b6db407c4_=embedded_pdf#tutorial\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eWi-Fi, Bluetooth, 4G, and SE-1515 Integration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1201 Pro supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLAN, Wi-Fi, Bluetooth, USB, and SD card\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e connectivity\u003c\/span\u003e\u003cspan class=\"\"\u003e. Reports can be exported in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePDF, JPG, BMP, PNG, TIFF, SCP, FDA-XML, and DICOM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e formats, and the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional SE-1515 Data Management System\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e enables \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDICOM Worklist, HL7, and GDT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e integration with HIS\/EMR\/PACS environments. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBi-directional communication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports worklist download and report upload for paperless workflow where infrastructure is available.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"24\"\u003e\u003ca href=\"https:\/\/novamedicasas.com\/wp-content\/uploads\/2026\/08\/SE-1201-PRO.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.doccheckshop.eu\/p\/102863-1-se-1201-pro-12-lead-ecg\/#cms-cross-selling-fallback-tab-pane\" rel=\"noreferrer\" aria-label=\"19\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e2500 mAh Battery with 4 h AUTO Mode \/ 2 h MANUAL Mode\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e14.8 V, 2500 mAh lithium-ion battery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapproximately 4 hours in AUTO mode (one report every 2 minutes) or 2 hours in MANUAL mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003echarge time ≤ 3 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The device operates on \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAC mains (100–240 V, 50\/60 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e when available.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"26\"\u003e\u003ca href=\"https:\/\/www.manualslib.de\/manual\/990912\/Edan-Se-1200-Pro.html?page=75\" rel=\"noreferrer\" aria-label=\"33\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSafety Classification: Class I, CF Type, Defibrillation-Proof\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1201 Pro is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass I with internal power supply, CF type, and defibrillation-proof\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, designed to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIEC 60601-1, IEC 60601-1-2, and IEC 60601-2-25\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e standards\u003c\/span\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePatient leakage current\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is specified as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e\u0026lt;10 μA (NC, AC\/DC)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e\u0026lt;50 μA (SFC, AC\/DC)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e \u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"27\"\u003e\u003ca href=\"https:\/\/novamedicasas.com\/wp-content\/uploads\/2026\/08\/SE-1201-PRO.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eRegulatory Status: FDA K222902, CE MDR Class IIa, China NMPA\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1201 Pro is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA-cleared under K222902 (July 28, 2023)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass II electrocardiograph (DPS)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , with the clearance explicitly covering \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eboth SE-1200 Pro and SE-1201 Pro\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The device is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE-marked as Class IIa under EU MDR 2017\/745\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, covered under \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTÜV SÜD CE 0123\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e EU MDR QMS Certificate \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eG10 091264 0025 Rev. 01\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. It also holds \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChina NMPA registration (粤械注准20222071820)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e \u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"29\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-c-cardiovascular-monitoring-devices\/DPS\/K222902?_x_output_type_b6db407c4_=embedded_pdf#tutorial\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.huanxiyl.com\/xindiantuji\/223374.html\" rel=\"noreferrer\" aria-label=\"10\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDevice Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12-channel resting electrocardiograph (simultaneous 12-lead acquisition)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA Clearance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eK222902 (July 28, 2023); Class II, 21 CFR 870.2340, Product Code DPS\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"32\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-c-cardiovascular-monitoring-devices\/DPS\/K222902?_x_output_type_b6db407c4_=embedded_pdf#tutorial\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE Marking\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eClass IIa, EU MDR 2017\/745; TÜV SÜD CE 0123; EU MDR QMS Certificate G10 091264 0025 Rev. 01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChina Registration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e粤械注准20222071820\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"34\"\u003e\u003ca href=\"https:\/\/www.huanxiyl.com\/xindiantuji\/223374.html\" rel=\"noreferrer\" aria-label=\"10\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAcquisition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e12 leads simultaneous via body surface electrodes; 9\/12-lead measurement method\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"35\"\u003e\u003ca href=\"https:\/\/www.doccheckshop.eu\/p\/102863-1-se-1201-pro-12-lead-ecg\/#cms-cross-selling-fallback-tab-pane\" rel=\"noreferrer\" aria-label=\"19\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e10.1-inch full LCD touchscreen, 1920 × 1200 resolution; rotates 25° clockwise\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"36\"\u003e\u003ca href=\"https:\/\/novamedicasas.com\/wp-content\/uploads\/2026\/08\/SE-1201-PRO.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.doccheckshop.eu\/p\/102863-1-se-1201-pro-12-lead-ecg\/#cms-cross-selling-fallback-tab-pane\" rel=\"noreferrer\" aria-label=\"19\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eA\/D Resolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e24-bit; 0.1575 μV\/LSB\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"38\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-c-cardiovascular-monitoring-devices\/DPS\/K222902?_x_output_type_b6db407c4_=embedded_pdf#tutorial\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSampling Frequency (Diagnostic ECG)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e64,000 Hz\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"39\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-c-cardiovascular-monitoring-devices\/DPS\/K222902?_x_output_type_b6db407c4_=embedded_pdf#tutorial\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSampling Rate (Pacemaker Channel)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e80,000 Hz (dedicated channel)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"40\"\u003e\u003ca href=\"https:\/\/www.doccheckshop.eu\/p\/102863-1-se-1201-pro-12-lead-ecg\/#cms-cross-selling-fallback-tab-pane\" rel=\"noreferrer\" aria-label=\"19\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePacemaker Detection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eAmplitude ±500 μV to ±700 mV; pulse width 30 μs to 2.0 ms; minimum detectable signal 30 μs \/ 500 μV\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"41\"\u003e\u003ca href=\"https:\/\/www.doccheckshop.eu\/p\/102863-1-se-1201-pro-12-lead-ecg\/#cms-cross-selling-fallback-tab-pane\" rel=\"noreferrer\" aria-label=\"19\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFrequency Response\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e0.01–350 Hz\u003c\/span\u003e\u003cspan class=\"\"\u003e; 0.01–500 Hz also referenced in distributor documentation\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"42\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-c-cardiovascular-monitoring-devices\/DPS\/K222902?_x_output_type_b6db407c4_=embedded_pdf#tutorial\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.doccheckshop.eu\/p\/102863-1-se-1201-pro-12-lead-ecg\/#cms-cross-selling-fallback-tab-pane\" rel=\"noreferrer\" aria-label=\"19\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInput Impedance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e≥ 100 MΩ (10 Hz)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"44\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-c-cardiovascular-monitoring-devices\/DPS\/K222902?_x_output_type_b6db407c4_=embedded_pdf#tutorial\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFilters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eAC: 50\/60 Hz\/off; DFT: 0.01\/0.05\/0.32\/0.67 Hz; EMG: 25\/35\/45 Hz\/off; Low-pass: 50–300 Hz range\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"45\"\u003e\u003ca href=\"https:\/\/www.doccheckshop.eu\/p\/102863-1-se-1201-pro-12-lead-ecg\/#cms-cross-selling-fallback-tab-pane\" rel=\"noreferrer\" aria-label=\"19\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInterpretation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eGlasgow automatic interpretation; SEMIP algorithm; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e per cleared labeling\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"46\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-c-cardiovascular-monitoring-devices\/DPS\/K222902?_x_output_type_b6db407c4_=embedded_pdf#tutorial\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWorkflow Automation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAuto-recording on signal readiness; pacemaker detection notification; reversed electrode \/ lead misconnection alerts; serious disease red alert\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWaveform Tools\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eGesture amplification and measurement; averaged template with manual P\/Q\/S\/T recalculation; report comparison\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInternal Storage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e\u0026gt;100,000 studies (distributor documentation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRecorder\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eBuilt-in thermal dot-matrix; 210 mm × 140 mm folded paper; 5–50 mm\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBattery\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e14.8 V, 2500 mAh Li-ion; ~4 h AUTO mode (report every 2 min) \/ ~2 h MANUAL mode; charge ≤3 h\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"48\"\u003e\u003ca href=\"https:\/\/www.manualslib.de\/manual\/990912\/Edan-Se-1200-Pro.html?page=75\" rel=\"noreferrer\" aria-label=\"33\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eAC 100–240 V, 50\/60 Hz; adapter output 19 V, 2.53 A\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"49\"\u003e\u003ca href=\"https:\/\/www.manualslib.de\/manual\/990912\/Edan-Se-1200-Pro.html?page=75\" rel=\"noreferrer\" aria-label=\"33\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDimensions \/ Weight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e298 × 258 × 82.5 mm; 4 kg (excluding paper and battery)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"50\"\u003e\u003ca href=\"https:\/\/novamedicasas.com\/wp-content\/uploads\/2026\/08\/SE-1201-PRO.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.doccheckshop.eu\/p\/102863-1-se-1201-pro-12-lead-ecg\/#cms-cross-selling-fallback-tab-pane\" rel=\"noreferrer\" aria-label=\"19\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eConnectivity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eLAN; Wi-Fi; Bluetooth; USB; SD card slot\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"52\"\u003e\u003ca href=\"https:\/\/novamedicasas.com\/wp-content\/uploads\/2026\/08\/SE-1201-PRO.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.doccheckshop.eu\/p\/102863-1-se-1201-pro-12-lead-ecg\/#cms-cross-selling-fallback-tab-pane\" rel=\"noreferrer\" aria-label=\"19\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eExport Formats\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003ePDF, JPG, BMP, PNG, TIFF, SCP, FDA-XML, DICOM (where configured)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"54\"\u003e\u003ca href=\"https:\/\/novamedicasas.com\/wp-content\/uploads\/2026\/08\/SE-1201-PRO.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.doccheckshop.eu\/p\/102863-1-se-1201-pro-12-lead-ecg\/#cms-cross-selling-fallback-tab-pane\" rel=\"noreferrer\" aria-label=\"19\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eData Management\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eOptional SE-1515; DICOM Worklist, HL7, GDT integration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSafety Classification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eClass I, internal power supply, CF type, defibrillation-proof\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"56\"\u003e\u003ca href=\"https:\/\/novamedicasas.com\/wp-content\/uploads\/2026\/08\/SE-1201-PRO.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSafety Standards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eIEC 60601-1:2015+A1:2012+A2:2020; EN 60601-1:2006\/A1:2013; IEC 60601-1-2:2014+A1:2020; EN 60601-1-2:2015; IEC\/EN 60601-2-25\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"57\"\u003e\u003ca href=\"https:\/\/novamedicasas.com\/wp-content\/uploads\/2026\/08\/SE-1201-PRO.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOptional Upgrades\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eCalculated 18-lead report (SE-1201 Pro exclusive); Glasgow algorithm; HRV; VCG; TVCG; SAECG\/VLP; FCG; DICOM Worklist\/HL7\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Patient Population\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAdult and pediatric patients; calculated 18-lead report for patients \u0026gt;18 years\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Use\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eAcquisition of ECG signals via body surface electrodes to help analyze and diagnose heart disease in hospitals or healthcare facilities by doctors and trained healthcare professionals; measurements and interpretive statements offered on an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"58\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-c-cardiovascular-monitoring-devices\/DPS\/K222902?_x_output_type_b6db407c4_=embedded_pdf#tutorial\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the EDAN SE-1201 Pro?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eClinical or Operational Challenge\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSE-1201 Pro Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed a portable 12-channel ECG with a large high-resolution touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e10.1-inch 1920 × 1200 touchscreen; 4 kg; 298 × 258 × 82.5 mm; 25° rotating display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed FDA-cleared 12-channel ECG with AI-assisted workflow\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eK222902 cleared; auto-recording; pacemaker detection alerts; serious-disease red notification; electrode misconnection hints\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed high-resolution pacemaker analysis\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eDedicated 80 kHz pacemaker channel; 30 μs \/ 500 μV minimum detection; ±500 μV to ±700 mV amplitude range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed access to a calculated 18-lead report for extended cardiac assessment\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eOptional calculated 18-lead report exclusive to SE-1201 Pro; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eclinical reference only, not for diagnosis\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed diagnostic-grade signal acquisition for adult and pediatric patients\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e24-bit A\/D; 64 kHz diagnostic sampling; 0.01–350 Hz; input impedance ≥ 100 MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed on-screen interpretation support with clear advisory labeling\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eGlasgow and SEMIP interpretation; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e per cleared labeling; gesture amplification and report comparison\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed HIS\/EMR\/PACS integration and paperless workflow\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLAN\/Wi-Fi\/Bluetooth; PDF\/JPG\/SCP\/FDA-XML\/DICOM export; optional SE-1515 with DICOM Worklist, HL7, GDT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed battery runtime for ward rounds and transport\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e2500 mAh; ~4 h AUTO mode \/ ~2 h MANUAL mode; charge ≤3 h\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed a device designed for routine disinfection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eWater-resistant surface; compact enclosure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46505279488044,"sku":null,"price":3599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/EdanSE-1201ProElectrocardiograph.png?v=1793007053","url":"https:\/\/www.globalhealthcaremedical.com\/products\/edan-se-1201-pro-electrocardiograph","provider":"Global Healthcare Medical","version":"1.0","type":"link"}