{"product_id":"edan-se-1202-electrocardiograph","title":"EDAN SE-1202 Electrocardiograph","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEDAN SE-1202\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12-channel advanced ECG workstation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e engineered for cardiology practices, hospitals, and diagnostic centers that require \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecomprehensive cardiac assessment beyond routine resting ECG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. It combines a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e10.1-inch high-resolution color touchscreen (1280 × 800)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efoldable living-hinge design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ewaterproof capacitive keys\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintegrated thermal printer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—bringing workstation-level diagnostic depth into a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e6.5 kg (excluding paper and battery)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e enclosure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1202 is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA-cleared under 510(k) K210140 (October 1, 2021)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass II electrocardiograph (21 CFR 870.2340, Product Code DPS)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e . A subsequent clearance under \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eK252463 (July 2, 2026)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e extends coverage to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSE-1202 Series (SE-1202, SE-1202E)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e . The cleared intended use covers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eacquisition of ECG signals from adult and pediatric patients through body surface ECG electrodes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, for use \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ein hospitals or healthcare facilities by doctors and trained healthcare professionals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einterpreted ECG with measurements and interpretive statements is offered on an advisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—it supports, but does not replace, clinician analysis. The FDA summary states \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e\"No clinical data. Bench testing only\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; performance was validated via EDAN's proprietary database and testing against \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIEC 60601-2-25, ANSI AAMI ES 60601-1, and IEC 60601-1-2\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eThe SEMIP algorithm's interpretive statements are contraindicated for neonatal patients (birth to 28 days)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e ; the 9-lead neonatal configuration is available for acquisition without SEMIP interpretation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe signal chain includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24-bit A\/D converter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e0.1192 μV\/LSB resolution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e64,000 Hz sampling frequency\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCMRR ≥ 140 dB (AC on)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efrequency response of 0.01–350 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ededicated pacemaker detection channel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e samples at \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e80,000 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, capturing stimuli as narrow as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e30 μs and as small as 500 μV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (amplitude range \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e±500 μV to ±700 mV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, pulse widths \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e30 μs to 2.0 ms\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e). The device supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e9-lead neonatal, 12-lead standard, and optional calculated 18-lead\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e configurations, alongside advanced analysis tools including \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVector ECG (VCG) and Timed Vector ECG (TVCG)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSignal-Average ECG (SAECG)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHeart Rate Variability (HRV)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eST-view\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFrequency-domain Correlative Cardiography (FCG)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eWorkflow features include \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elong-time sampling up to 1,800 seconds\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eauto arrhythmia detection with highlighted segments and auto-saved strips\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eon-screen diagnosis with waveform amplification and measurement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ereport editing and side-by-side comparison\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecolor-coded lead placement detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The SE-1202 stores \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapproximately 1,000 ECG records internally\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with connectivity via \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLAN, Wi-Fi (included per distributor documentation), and optional 4G\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and export in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePDF, JPG, FDA-XML, SCP, DICOM, and HL7\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e formats where configured.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1202 is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE-marked as a Class IIa medical device under EU MDR 2017\/745\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, covered by \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTÜV SÜD Product Service GmbH (Notified Body 0123)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEU MDR Quality Management System Certificate No. G10 091264 0025 Rev. 01\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, valid from \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMay 31, 2022 to February 17, 2026\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with device group \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eZ120503 – ELECTROCARDIOGRAPHS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e classified as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass IIa\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The device is powered by \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAC mains (100–240 V, 50\/60 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e or a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e14.8 V lithium-ion battery (2,500 mAh or 5,000 mAh)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , with charge times of \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3 or 6 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e respectively.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1202 is built for facilities that need \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ean FDA-cleared advanced ECG workstation with a foldable touchscreen, pacemaker analysis, extended cardiac assessment tools, and paperless workflow capability\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—without the footprint of a conventional cart-based system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e10.1-Inch Foldable Touchscreen with Waterproof Capacitive Keys\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e10.1-inch multicolor LCD touchscreen (1280 × 800 resolution)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e displays all 12 leads with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eliving-hinge foldable design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e that adjusts for comfortable viewing from different positions. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ewaterproof capacitive keys with multi-color breathing lights\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e support \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eeasy cleaning and sterilization\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e between patients, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eglass-covered surface\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e facilitates infection control. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eon-screen toolbar with customizable hotkeys\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e allows users to organize frequently used functions into a preferred workflow.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e12-Lead Standard, 9-Lead Neonatal, and Optional Calculated 18-Lead\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1202 supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12-lead standard resting ECG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e9-lead resting ECG tailored for neonates\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional calculated 18-lead report\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Per the China registration labeling, the calculated 18-lead function derives an 18-lead report from a 12-lead acquisition for patients \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eover 18 years of age\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ederived waveforms are not fully identical to actual measured waveforms\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and if actual posterior or right-sided waveforms are required, electrodes must be placed at the corresponding sites and measured directly. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eThe calculated report is for clinical reference only and is not to be used as a basis for diagnosis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eThe SEMIP algorithm's interpretive statements are contraindicated for neonatal patients (birth to 28 days)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e ; the 9-lead neonatal mode supports acquisition without SEMIP interpretation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e80 kHz Dedicated Pacemaker Detection Channel\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ededicated pacemaker detection channel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e samples at \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e80,000 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, separate from the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e64,000 Hz diagnostic ECG path\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The pacemaker circuit captures stimuli as narrow as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e30 μs and as small as 500 μV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with amplitude handling from \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e±500 μV to ±700 mV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and pulse widths from \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e30 μs to 2.0 ms\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. This configuration supports visualization and marking of pacemaker stimuli that may be difficult to resolve at standard ECG sampling rates.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eAdvanced Cardiac Analysis: VCG, TVCG, SAECG, HRV, ST-View, and FCG\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1202 includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVector ECG (VCG)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTimed Vector ECG (TVCG)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for spatial cardiac electrical assessment, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSignal-Average ECG (SAECG)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for late potential analysis, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHeart Rate Variability (HRV)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for autonomic function review, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eST-view\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for intuitive ST-segment display, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFrequency-domain Correlative Cardiography (FCG)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e . \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePharmacological study\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e support is also referenced. These tools extend the platform beyond routine resting ECG into advanced cardiac diagnostic support.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eLong-Time Sampling and Auto Arrhythmia Detection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1202 supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elong-time sampling up to 1,800 seconds\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, allowing prolonged rhythm capture for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epre-treatment diagnosis or post-treatment evaluation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAuto arrhythmia detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e highlights abnormal trace segments on the display and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatically saves strips\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for further analysis, supporting review of transient or intermittent events.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eOn-Screen Paperless Diagnosis with Report Comparison\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1202 is designed as an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e\"All-in-One\" workstation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supporting a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecomplete paperless workflow\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e: all measurements and diagnosis can be performed on screen, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eany waveform segment can be amplified and measured with gesture operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eany report can be edited and confirmed\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eany two reports can be selected and compared\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for longitudinal follow-up.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e1,000 ECG Internal Storage with LAN\/Wi-Fi\/4G and DICOM\/HL7\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1202 stores \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapproximately 1,000 ECG records internally\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Connectivity covers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLAN, Wi-Fi (included per distributor documentation), and optional 4G\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with report export in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePDF, JPG, FDA-XML, SCP, DICOM, and HL7\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e formats where configured. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional SE-1515 Data Management System\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDICOM Worklist, HL7, and GDT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e integration with HIS\/EMR\/PACS environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e2,500 \/ 5,000 mAh Battery Options with 3 \/ 6 Hour Charge\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e14.8 V lithium-ion battery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is available in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e2,500 mAh\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5,000 mAh\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e configurations, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003echarge times of 3 and 6 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e respectively. The device operates on \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAC mains (100–240 V, 50\/60 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e when available, with input current \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e0.9–0.4 A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSafety Classification and Regulatory Status\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1202 is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA-cleared under K210140 (2021)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eK252463 (2026)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for adult and pediatric ECG acquisition, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSEMIP interpretive statements contraindicated for neonates (birth to 28 days)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e . The device is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE-marked as a Class IIa medical device under EU MDR 2017\/745\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, covered by \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTÜV SÜD (CE 0123)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e QMS Certificate \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eG10 091264 0025 Rev. 01\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (valid \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e2022-05-31 to 2026-02-17\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e). \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNo independent China NMPA registration specific to the SE-1202 was identified during preparation of this page\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; availability and cleared claims vary by market.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDevice Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12-channel advanced ECG workstation (9\/12-lead acquisition)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA Clearance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eK210140 (October 1, 2021); K252463 (July 2, 2026, SE-1202 Series); Class II, 21 CFR 870.2340, Product Code DPS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE Marking\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eClass IIa, EU MDR 2017\/745; TÜV SÜD CE 0123; QMS Certificate G10 091264 0025 Rev. 01 (valid 2022-05-31 to 2026-02-17; device group Z120503)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAcquisition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e9 or 12 leads simultaneous via body surface electrodes; optional calculated 18-lead\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e10.1-inch multicolor LCD touchscreen, 1280 × 800 resolution; foldable 25° clockwise\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInput\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eWaterproof capacitive keys with multi-color breathing lights; customizable on-screen toolbar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eA\/D Resolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e24-bit; 0.1192 μV\/LSB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSampling Frequency (Diagnostic ECG)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e64,000 Hz\/channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSampling Rate (Pacemaker Channel)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e80,000 Hz (dedicated channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePacemaker Detection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAmplitude ±500 μV to ±700 mV; pulse width 30 μs to 2.0 ms; minimum detectable signal 30 μs \/ 500 μV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFrequency Response\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.01–350 Hz (−3 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCMRR\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≥ 140 dB (AC on); ≥ 123 dB (AC off)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInput Impedance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≥ 100 MΩ (10 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTime Constant\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≥ 5 s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFilters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAC: off\/50\/60 Hz; DFT: 0.01\/0.05\/0.32\/0.67 Hz; EMG: 25\/35\/45 Hz\/off; Low-pass: 75–350 Hz range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInterpretation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eSEMIP or Glasgow algorithms; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSEMIP interpretive statements contraindicated for neonates (birth to 28 days)\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAdvanced Analysis\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eVCG, TVCG, SAECG, HRV, ST-view, FCG, pharmacological study; optional calculated 18-lead report (patients \u0026gt;18 years; clinical reference only)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWorkflow Automation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLong-time sampling up to 1,800 s; auto arrhythmia detection with auto-saved strips; on-screen diagnosis with gesture amplification; report comparison; color-coded lead placement detection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInternal Storage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eApproximately 1,000 ECG records\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRecorder\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eBuilt-in thermal dot-matrix; 210 mm × 295 mm or 215 mm × 280 mm folded paper; 5–50 mm\/s; external printer support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBattery\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e14.8 V Li-ion; 2,500 mAh (3 h charge) or 5,000 mAh (6 h charge)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAC 100–240 V, 50\/60 Hz; input current 0.9–0.4 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDimensions \/ Weight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e400 × 360 × 90 mm; ≤6.5 kg (excluding paper and battery)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eConnectivity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLAN; Wi-Fi (included per distributor documentation); optional 4G; USB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eExport Formats\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePDF, JPG, FDA-XML, SCP, DICOM, HL7 (where configured)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eData Management\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eOptional SE-1515; DICOM Worklist, HL7, GDT integration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Patient Population\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eAdult and pediatric patients; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSEMIP interpretive statements contraindicated for neonates (birth to 28 days)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e ; calculated 18-lead report for patients \u0026gt;18 years\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Use\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eAcquisition of ECG signals via body surface electrodes to help analyze and diagnose heart disease in hospitals or healthcare facilities by doctors and trained healthcare professionals; measurements and interpretive statements offered on an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the EDAN SE-1202?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eClinical or Operational Challenge\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSE-1202 Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed an advanced ECG workstation with a foldable touchscreen and waterproof keys\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e10.1-inch 1280 × 800 touchscreen with living-hinge fold; waterproof capacitive keys for easy disinfection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed FDA-cleared 12-channel ECG with pacemaker analysis\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eK210140 and K252463 cleared; dedicated 80 kHz pacemaker channel with 30 μs \/ 500 μV sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed neonatal acquisition without SEMIP interpretive contraindications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e9-lead neonatal mode for acquisition; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSEMIP interpretive statements contraindicated for birth–28 days\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed advanced cardiac assessment beyond routine resting ECG\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eVCG, TVCG, SAECG, HRV, ST-view, FCG, pharmacological study; optional calculated 18-lead report\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed extended rhythm capture and on-screen diagnosis\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1,800-second long-time sampling; auto arrhythmia detection with auto-saved strips; gesture amplification and report comparison\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed HIS\/EMR\/PACS integration and paperless workflow\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLAN\/Wi-Fi\/4G; PDF\/JPG\/FDA-XML\/SCP\/DICOM\/HL7 export; optional SE-1515 with DICOM Worklist, HL7, GDT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed substantial internal storage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eApproximately 1,000 ECG records\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed CE MDR Class IIa coverage for European markets\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eTÜV SÜD CE 0123 QMS Certificate G10 091264 0025 Rev. 01 (valid to 2026-02-17)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46507172954156,"sku":null,"price":4699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/EdanSE-1202Electrocardiograph.png?v=1793014958","url":"https:\/\/www.globalhealthcaremedical.com\/products\/edan-se-1202-electrocardiograph","provider":"Global Healthcare Medical","version":"1.0","type":"link"}