{"product_id":"edan-se-1202e-12-channel-electrocardiograph","title":"EDAN SE-1202E 12-Channel Electrocardiograph","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEDAN SE-1202E\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e13.3-inch flagship configuration within EDAN‘s SE-1202 Series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, a 12-channel ECG workstation designed for cardiology practices, hospitals, and diagnostic centers that need \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eexpanded lead coverage, advanced analysis tools, and a larger viewing area\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e than the standard SE-1202. It combines a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e13.3-inch high-resolution color touchscreen (1920 × 1080)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efoldable design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ewaterproof capacitive keys\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintegrated thermal printer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—bringing workstation-level diagnostic depth into a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e≤6.5 kg (excluding paper and battery)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e enclosure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1202 Series, including both the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSE-1202 and SE-1202E models\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA-cleared under 510(k) K252463 (July 2, 2026)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass II electrocardiograph (21 CFR 870.2340, Product Code DPS)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e . The cleared intended use covers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eacquisition of ECG signals from adult and pediatric patients through body surface ECG electrodes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, for use \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ein hospitals or healthcare facilities by doctors and trained healthcare professionals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einterpreted ECG with measurements and interpretive statements is offered on an advisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—it supports, but does not replace, clinician analysis. The FDA summary for the SE-1202 Series states \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e“No clinical data. Bench testing only”\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; performance was validated through bench testing and software verification rather than prospective clinical endpoint studies.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1202E is built around a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24-bit A\/D converter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e64,000 Hz diagnostic ECG sampling\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCMRR ≥ 140 dB (AC on)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efrequency response of 0.01–350 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ededicated pacemaker detection channel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esampling rates up to 160,000 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e per EDAN’s product documentation, exceeding the 80 kHz pacemaker channel on the standard SE-1202, with detection thresholds extending to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esignals as narrow as 30 μs and as small as 500 μV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The device supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e9-lead neonatal, 12-lead standard, and CardiSync 18 calculated 18-lead\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e configurations, alongside advanced analysis tools including \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVector ECG (VCG) and Timed Vector ECG (TVCG)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSignal-Average ECG (SAECG)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHeart Rate Variability (HRV)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eST-view\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFrequency-domain Correlative Cardiography (FCG)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eWhat distinguishes the SE-1202E is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCardiSync 18\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e: a calculated 18-lead analysis that derives \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eright precordial (V3R, V4R, V5R) and posterior (V7, V8, V9) leads\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e from a standard 10-electrode placement in a single press. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eThese extended leads are calculated by the CardiSync 18 algorithm, not directly measured\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; if actual posterior or right-sided waveforms are required, electrodes must be placed at the corresponding sites and measured directly. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eThe calculated report is intended as a clinical reference aid only and is not to be used as a basis for diagnosis.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e The SE-1202E also supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elong-time sampling up to 1,800 seconds\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eauto arrhythmia detection with auto-saved strips\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eon-screen paperless diagnosis with gesture amplification and report comparison\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecolor-coded lead placement detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1202E stores \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapproximately 10,000 ECG records internally\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with connectivity via \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLAN, Wi-Fi (included per distributor documentation), and optional 4G\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and export in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePDF, JPG, FDA-XML, SCP, DICOM, and HL7\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e formats where configured. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e14.8 V lithium-ion battery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is available in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e2,500 mAh (3-hour charge)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5,000 mAh (6-hour charge)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e configurations. The device is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE-marked as a Class IIa medical device under EU MDR 2017\/745\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSE-1202E added to EDAN’s MDR certification portfolio in December 2024\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e according to the company’s 2024 annual report. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNo independent China NMPA registration specific to the SE-1202E was identified during preparation of this page\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; availability and cleared claims vary by market.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1202E is built for facilities that need \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ea larger-display advanced ECG workstation with calculated 18-lead capability, high-resolution pacemaker analysis, and paperless workflow tools\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—without the footprint of a conventional cart-based system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e13.3-Inch Touchscreen with Foldable Design and Waterproof Keys\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e13.3-inch high-resolution color touchscreen (1920 × 1080)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provides the largest viewing area in the SE-1202 Series, displaying all 12 leads with ample space for waveforms, measurements, and on-screen toolbars. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efoldable living-hinge design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e adjusts for comfortable viewing from different positions, and the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ewaterproof capacitive keys\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e support routine cleaning and disinfection between patients. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eglass-covered surface\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e facilitates infection control in high-turnover clinical environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eCardiSync 18: Calculated 18-Lead Analysis from Standard 10-Electrode Placement\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCardiSync 18\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e derives \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eright precordial (V3R, V4R, V5R) and posterior (V7, V8, V9) leads\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e from a standard 12-lead acquisition in a single press, allowing a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecalculated 18-lead analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e without repositioning electrodes. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eThese extended leads are calculated by the algorithm, not directly measured\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; if actual posterior or right-sided waveforms are clinically required, electrodes must be placed at the corresponding sites and measured directly. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eThe calculated 18-lead report is intended as a clinical reference aid only and is not to be used as a basis for diagnosis.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e This function is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eexclusive to the SE-1202E\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e within the SE-1202 Series.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e160 kHz Pacemaker Detection Channel with 30 μs \/ 500 μV Sensitivity\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1202E includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ededicated pacemaker detection channel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with sampling rates up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e160,000 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e per EDAN’s product documentation—\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edouble the 80 kHz pacemaker channel on the standard SE-1202\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—supporting detection of pacemaker stimuli as narrow as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e30 μs and as small as 500 μV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with amplitude handling from \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e±500 μV to ±700 mV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and pulse widths from \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e30 μs to 2.0 ms\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. This configuration is intended to support visualization and marking of pacemaker stimuli that may be difficult to resolve at standard ECG sampling rates.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eAdvanced Cardiac Analysis: VCG, TVCG, SAECG, HRV, ST-View, and FCG\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1202E includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVector ECG (VCG)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTimed Vector ECG (TVCG)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for spatial cardiac electrical assessment, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSignal-Average ECG (SAECG)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for late potential analysis, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHeart Rate Variability (HRV)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for autonomic function review, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eST-view\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for intuitive ST-segment display, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFrequency-domain Correlative Cardiography (FCG)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e . \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePharmacological study\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e support is also referenced. These tools extend the platform beyond routine resting ECG into advanced cardiac diagnostic support.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eLong-Time Sampling and Auto Arrhythmia Detection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1202E supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elong-time sampling up to 1,800 seconds\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, allowing prolonged rhythm capture for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epre-treatment diagnosis or post-treatment evaluation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAuto arrhythmia detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e highlights abnormal trace segments on the display and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatically saves strips\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for further analysis, supporting review of transient or intermittent events.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eOn-Screen Paperless Diagnosis with Report Comparison\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1202E is designed as an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e“All-in-One” workstation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supporting a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecomplete paperless workflow\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e: all measurements and diagnosis can be performed on screen, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eany waveform segment can be amplified and measured with gesture operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eany report can be edited and confirmed\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eany two reports can be selected and compared\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for longitudinal follow-up.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e10,000 ECG Internal Storage with LAN\/Wi-Fi\/4G and DICOM\/HL7\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1202E stores \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapproximately 10,000 ECG records internally\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—ten times the capacity of the standard SE-1202. Connectivity covers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLAN, Wi-Fi (included per distributor documentation), and optional 4G\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with report export in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePDF, JPG, FDA-XML, SCP, DICOM, and HL7\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e formats where configured. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional SE-1515 Data Management System\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDICOM Worklist, HL7, and GDT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e integration with HIS\/EMR\/PACS environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e2,500 \/ 5,000 mAh Battery Options with 3 \/ 6 Hour Charge\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e14.8 V lithium-ion battery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is available in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e2,500 mAh (3-hour full charge)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5,000 mAh (6-hour full charge)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e configurations. The device operates on \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAC mains (100–240 V, 50\/60 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e when available, with input current \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e0.9–0.4 A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSafety Classification and Regulatory Status\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1202E is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA-cleared under K252463 (2026)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e as part of the SE-1202 Series for adult and pediatric ECG acquisition. The device is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE-marked as a Class IIa medical device under EU MDR 2017\/745\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSE-1202E added to EDAN’s MDR certification portfolio in December 2024\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e per the company’s 2024 annual report. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNo independent China NMPA registration specific to the SE-1202E was identified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; availability and cleared claims vary by market.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDevice Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12-channel advanced ECG workstation (9\/12-lead acquisition; calculated 18-lead on SE-1202E)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA Clearance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eK252463 (July 2, 2026); Class II, 21 CFR 870.2340, Product Code DPS; covers SE-1202 and SE-1202E\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE Marking\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eClass IIa, EU MDR 2017\/745; SE-1202E added to MDR portfolio December 2024 per EDAN annual report\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAcquisition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e9 or 12 leads simultaneous via body surface electrodes; CardiSync 18 calculated 18-lead on SE-1202E\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e13.3-inch multicolor LCD touchscreen, 1920 × 1080 resolution; foldable 25° clockwise\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInput\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eWaterproof capacitive keys with multi-color breathing lights; customizable on-screen toolbar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eA\/D Resolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e24-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSampling Frequency (Diagnostic ECG)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e64,000 Hz\/channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSampling Rate (Pacemaker Channel)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eUp to 160,000 Hz (SE-1202E); 80,000 Hz on standard SE-1202\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePacemaker Detection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAmplitude ±500 μV to ±700 mV; pulse width 30 μs to 2.0 ms; minimum detectable signal 30 μs \/ 500 μV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFrequency Response\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.01–350 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCMRR\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≥ 140 dB (AC on)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInput Impedance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≥ 100 MΩ (10 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInterpretation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eGlasgow or SEMIP algorithms; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAdvanced Analysis\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eVCG, TVCG, SAECG, HRV, ST-view, FCG, pharmacological study; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCardiSync 18 calculated 18-lead (SE-1202E exclusive; clinical reference only, not for diagnosis)\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWorkflow Automation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLong-time sampling up to 1,800 s; auto arrhythmia detection with auto-saved strips; on-screen diagnosis with gesture amplification; report comparison; color-coded lead placement detection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInternal Storage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eApproximately 10,000 ECG records (SE-1202E); approximately 1,000 on SE-1202\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRecorder\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eBuilt-in thermal dot-matrix; 210 mm × 295 mm or 215 mm × 280 mm folded paper; 5–50 mm\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBattery\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e14.8 V Li-ion; 2,500 mAh (3 h full charge) or 5,000 mAh (6 h full charge)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAC 100–240 V, 50\/60 Hz; input current 0.9–0.4 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDimensions \/ Weight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e400 × 360 × 90 mm (±2 mm); ≤6.5 kg (excluding paper and battery)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eConnectivity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLAN; Wi-Fi (included per distributor documentation); optional 4G; USB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eExport Formats\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePDF, JPG, FDA-XML, SCP, DICOM, HL7 (where configured)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eData Management\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eOptional SE-1515; DICOM Worklist, HL7, GDT integration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Patient Population\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eAdult and pediatric patients; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCardiSync 18 calculated report for patients \u0026gt;18 years; clinical reference only, not for diagnosis\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Use\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eAcquisition of ECG signals via body surface electrodes to help analyze and diagnose heart disease in hospitals or healthcare facilities by doctors and trained healthcare professionals; measurements and interpretive statements offered on an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the EDAN SE-1202E?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eClinical or Operational Challenge\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSE-1202E Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed a large 13.3-inch touchscreen for advanced ECG review\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e13.3-inch 1920 × 1080 foldable touchscreen; waterproof capacitive keys\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed calculated 18-lead coverage without repositioning electrodes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eCardiSync 18 derives V3R\/V4R\/V5R and V7\/V8\/V9 from standard 10-electrode placement; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecalculated, clinical reference only, not for diagnosis\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed high-resolution pacemaker analysis with the highest sampling rate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eDedicated pacemaker channel up to 160,000 Hz; 30 μs \/ 500 μV minimum detection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed advanced cardiac assessment beyond routine resting ECG\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eVCG, TVCG, SAECG, HRV, ST-view, FCG, pharmacological study\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed extended rhythm capture and on-screen diagnosis\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1,800-second long-time sampling; auto arrhythmia detection with auto-saved strips; gesture amplification and report comparison\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed substantial internal storage for high-volume departments\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eApproximately 10,000 ECG records internally\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed HIS\/EMR\/PACS integration and paperless workflow\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLAN\/Wi-Fi\/4G; PDF\/JPG\/FDA-XML\/SCP\/DICOM\/HL7 export; optional SE-1515 with DICOM Worklist, HL7, GDT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed FDA and CE MDR regulatory coverage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eFDA K252463; CE MDR Class IIa (SE-1202E added to MDR portfolio December 2024)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46507227447340,"sku":null,"price":3899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/EDANSE-1202E12-ChannelElectrocardiograph.png?v=1793015720","url":"https:\/\/www.globalhealthcaremedical.com\/products\/edan-se-1202e-12-channel-electrocardiograph","provider":"Global Healthcare Medical","version":"1.0","type":"link"}