{"product_id":"edan-se-1515-pc-ecg","title":"EDAN SE-1515 PC ECG","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eThe price of SE-1515 PC ECG Analysis Software is\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e $600.\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEDAN SE-1515\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePC-based ECG workstation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e that transforms a standard computer into a comprehensive cardiac diagnostic platform. Unlike a standalone ECG cart, the SE-1515 separates the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eacquisition front-end\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (a compact sampling box) from the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecomputing and display environment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (the clinician’s PC), allowing departments to leverage existing computer hardware while gaining \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eresting ECG, stress ECG, and data management\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e capabilities in a single software-driven system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1515 is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA-cleared under 510(k) K152427 (February 5, 2016)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass II electrocardiograph (21 CFR 870.2340, Product Code DPS)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e . The cleared intended use states the device \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eacquires, processes, and stores ECG signals from adult and pediatric patients undergoing stress exercise tests or resting tests\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintended to be used only in hospitals and healthcare facilities by doctors and trained healthcare professionals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Critically, the cleared labeling specifies that the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECG with measurements and interpretive statements is offered to clinicians on an advisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—it supports, but does not replace, clinician analysis and diagnosis. The FDA summary states \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e“No clinical data. Substantial equivalence supported by non-clinical bench testing”\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, including \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eelectrical safety (IEC 60601-1), EMC (IEC 60601-1-2), performance testing (IEC 60601-2-25), biocompatibility (ISO 10993-1), and software verification\/validation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"1\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-c-cardiovascular-monitoring-devices\/DPS\/K152427#tutorial\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1515’s flexibility lies in its \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emodular sampling box ecosystem\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The system supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e9, 12, 15, 16, and 18-lead configurations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e depending on the sampling box selected—from the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDP12 and DX12 (12-lead wired or wireless)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDE15 (15\/16-lead wired)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDE18 (18-lead wired)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDX12 transmitter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBluetooth\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e to transmit ECG signals wirelessly, with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e113 g transmitter weight\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e≥12 hours of operation on two AA batteries\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDE18\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDE15\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e sampling boxes include a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003econvenient sampling button and signal quality indicator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"3\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/27s7xu\/edan-se-1515-pc-ecg-user-manual-appendix-1-technical-specifications#page101#1\" rel=\"noreferrer\" aria-label=\"11\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eFor stress ECG, the SE-1515 integrates with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecompatible treadmills, ergometers, and external blood pressure monitors\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, supporting \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eexercise protocols\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for cardiac stress testing. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDX22 wireless sampling box\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for stress applications breaks the constraints of leadwires and distance, allowing patients to move freely during testing. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMT-1000 medical-grade PC trolley\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provides a rotatable screen and gimbaled wheels for use in crowded clinical spaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe software platform includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGlasgow interpretation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elead inversion detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic arrhythmia segment recording\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emulti-format report export (PDF, XML, SCP, DICOM, JPG)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHIS\/EMR\/PACS integration via HL7, DICOM, or GDT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Optional upgrades add \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHolter analysis (SE-2003\/SE-2012\/SE-3012)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eABP analysis (SA-10)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHolter \u0026amp; ABP 2-in-1 analysis (SA-20)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , allowing the SE-1515 to serve as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecentral ECG data management hub\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for multiple cardiac diagnostic modalities.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"4\"\u003e\u003ca href=\"https:\/\/promotal-medconnect.com\/zh\/tools\/ecg-edan-se-1515\" rel=\"noreferrer\" aria-label=\"13\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRegulatory status:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e The SE-1515 is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA-cleared under K152427\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE-marked as a medical device\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, compliant with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIEC 60601-1, IEC 60601-1-2, and IEC 60601-2-25\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. It is classified as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass I, Type CF, defibrillation-proof\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e under the user manual’s safety specifications\u003c\/span\u003e\u003cspan class=\"\"\u003e. Availability and cleared claims vary by market; confirm local registration and labeling before purchase.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"5\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-c-cardiovascular-monitoring-devices\/DPS\/K152427#tutorial\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/27s7xu\/edan-se-1515-pc-ecg-user-manual-appendix-1-technical-specifications#page101#1\" rel=\"noreferrer\" aria-label=\"11\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/promotal-medconnect.com\/zh\/tools\/ecg-edan-se-1515\" rel=\"noreferrer\" aria-label=\"13\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1515 is built for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ehospitals, clinics, and diagnostic centers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e that need a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003escalable, PC-based ECG platform capable of spanning resting ECG, stress testing, and multi-modality data management\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—without dedicating a standalone ECG cart to every examination room.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eModular Sampling Box Ecosystem: 9 to 18 Leads, Wired or Wireless\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1515’s sampling box options allow the platform to scale across clinical needs. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDP12\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDX12\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provide \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12-lead resting ECG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in wired or wireless configurations; the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDE15\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDE18\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e extend acquisition to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e15, 16, and 18 leads\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, adding \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eright precordial and posterior wall coverage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for more comprehensive cardiac assessment\u003c\/span\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDX12\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e wireless transmitter uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBluetooth\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and operates for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e≥12 hours on two AA batteries\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, allowing ECG acquisition without tethering the patient to the PC\u003c\/span\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDE15\/DE18\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e boxes include a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esampling button and signal quality indicator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for at-a-glance electrode confidence.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"9\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/27s7xu\/edan-se-1515-pc-ecg-user-manual-appendix-1-technical-specifications#page101#1\" rel=\"noreferrer\" aria-label=\"11\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eFDA-Cleared for Both Resting and Stress ECG\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1515’s FDA clearance explicitly covers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estress exercise tests and resting tests\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadult and pediatric patients\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. This dual indication means the same platform can serve \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eroutine ECG screening\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eexercise stress testing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e without requiring separate devices. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDX22 wireless stress sampling box\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMT-1000 trolley\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e support the mobile requirements of stress testing, while integration with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etreadmills, ergometers, and stress BP monitors\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e extends the platform into complete exercise physiology workflows.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"10\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-c-cardiovascular-monitoring-devices\/DPS\/K152427#tutorial\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eGlasgow Interpretation with Advisory-Only Labeling\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1515 includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGlasgow interpretation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomated ECG measurements\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einterpretive statements offered on an advisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e under the FDA labeling\u003c\/span\u003e\u003cspan class=\"\"\u003e. The software also includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elead inversion detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic arrhythmia segment recording\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, supporting workflow efficiency without replacing clinician judgment\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"11\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/submissions\/CV\/subpart-c-cardiovascular-monitoring-devices\/DPS\/K152427#tutorial\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/promotal-medconnect.com\/zh\/tools\/ecg-edan-se-1515\" rel=\"noreferrer\" aria-label=\"13\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e16,000 Hz Sampling with 24-Bit A\/D Converter\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-1515’s acquisition chain includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e16,000 Hz sampling rate\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24-bit A\/D converter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, parameters positioned to support \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esignal fidelity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e across resting and stress applications\u003c\/span\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDX12\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e wireless transmitter samples at \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e10 kHz for acquisition (0.5 kHz for analysis)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eresolution of 2.52 μV\/LSB\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efrequency response of 0.05–150 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"15\"\u003e\u003ca href=\"https:\/\/promotal-medconnect.com\/zh\/tools\/ecg-edan-se-1515\" rel=\"noreferrer\" aria-label=\"13\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eMulti-Format Export and HIS\/EMR\/PACS Integration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eReports can be exported in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePDF, XML, SCP, DICOM, and JPG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e formats, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHIS\/EMR\/PACS integration via HL7, DICOM, or GDT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e protocols\u003c\/span\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional data management function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e allows the SE-1515 to serve as a centralized ECG repository, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHolter analysis (SE-2003\/SE-2012\/SE-3012)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eABP analysis (SA-10)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHolter \u0026amp; ABP 2-in-1 analysis (SA-20)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e upgrades extend the platform into ambulatory cardiac diagnostics.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"16\"\u003e\u003ca href=\"https:\/\/promotal-medconnect.com\/zh\/tools\/ecg-edan-se-1515\" rel=\"noreferrer\" aria-label=\"13\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eOn-Screen Diagnosis, Measurement Tools, and Report Comparison\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eClinicians can \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emagnify any waveform segment and measure it on-screen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emanually modify measurement positions\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecompare current reports with historical studies side-by-side\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecustomize report content\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for general screening or detailed diagnostic review. These tools are designed to support \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eefficient, paperless ECG interpretation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e within the software environment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eCompact Sampling Boxes with Battery-Powered Wireless Option\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDX12 transmitter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e weighs \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e113 g (excluding battery)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and measures \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e63 × 107 × 23 mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e≥12 hours of operation on two AA batteries\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDP12\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e wired box weighs \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e210 g\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and is powered directly from the PC via USB. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDE15\/DE18\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e boxes weigh \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e215 g\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and measure \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e139 × 96 × 25 mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. This range of form factors allows the acquisition front-end to match the clinical setting—from bedside resting ECG to mobile stress testing.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"17\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/27s7xu\/edan-se-1515-pc-ecg-user-manual-appendix-1-technical-specifications#page101#1\" rel=\"noreferrer\" aria-label=\"11\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eScalable Data Management Hub for Multi-Modality Cardiac Diagnostics\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eBeyond ECG acquisition, the SE-1515 software supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edata management functions\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e that allow the platform to organize, label, and retrieve ECG records across departments. Optional \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHolter, ABP, and combined Holter\/ABP analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e upgrades turn the SE-1515 into a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecentral review station\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for ambulatory cardiac studies, reducing the need for separate workstation software for each modality.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDevice Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePC-based ECG workstation (resting and stress ECG)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA Clearance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eK152427 (February 5, 2016); Class II, 21 CFR 870.2340, Product Code DPS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE Marking\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eCE-marked medical device; compliant with IEC 60601-1, IEC 60601-1-2, IEC 60601-2-25\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLead Configurations\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e9, 12, 15, 16, 18 leads (sampling box dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSampling Boxes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eDP12 (12-lead wired); DX12 (12-lead wireless, Bluetooth); DE15 (15\/16-lead wired); DE18 (18-lead wired); DP22\/DX22 (12-lead for stress)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSampling Rate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e16,000 Hz (platform); DX12: 10 kHz acquisition \/ 0.5 kHz analysis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eA\/D Resolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e24-bit; 2.52 μV\/LSB (DX12)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFrequency Response\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.05–150 Hz (−3 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCMRR\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eDP12 ≥115 dB; DX12 ≥100 dB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHR Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e30–300 bpm, ±1 bpm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePacemaker Detection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSafety Classification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eClass I, Type CF, defibrillation-proof; not for use with flammable gases\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"19\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/27s7xu\/edan-se-1515-pc-ecg-user-manual-appendix-1-technical-specifications#page101#1\" rel=\"noreferrer\" aria-label=\"11\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSampling Box Weight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eDX12 transmitter: ~113 g (excl. battery); DP12: ~210 g; DE15\/DE18: ~215 g\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"20\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/27s7xu\/edan-se-1515-pc-ecg-user-manual-appendix-1-technical-specifications#page101#1\" rel=\"noreferrer\" aria-label=\"11\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWireless Battery\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eDX12: 2× AA, ≥12 hours operation\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"21\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/27s7xu\/edan-se-1515-pc-ecg-user-manual-appendix-1-technical-specifications#page101#1\" rel=\"noreferrer\" aria-label=\"11\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eExport Formats\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePDF, XML, SCP, DICOM, JPG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eConnectivity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eHL7, DICOM, GDT; Bluetooth (DX12)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInterpretation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eGlasgow algorithm; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e per cleared labeling\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eStress ECG\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eIntegrates with treadmills, ergometers, and stress BP monitors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOptional Upgrades\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eHolter analysis (SE-2003\/SE-2012\/SE-3012); ABP analysis (SA-10); Holter \u0026amp; ABP 2-in-1 (SA-20)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Patient Population\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAdult and pediatric patients\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Use\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eAcquisition, processing, and storage of ECG signals from adult and pediatric patients undergoing stress exercise or resting tests in hospitals and healthcare facilities by doctors and trained healthcare professionals; measurements and interpretive statements offered on an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the EDAN SE-1515?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eClinical or Operational Challenge\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSE-1515 Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed a single platform for resting ECG and stress testing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eFDA-cleared for both resting and stress exercise ECG; DX22 wireless stress box and MT-1000 trolley support mobile stress workflows\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed scalable lead configurations from 9 to 18 leads\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eModular sampling boxes: DP12\/DX12 (12-lead), DE15 (15\/16-lead), DE18 (18-lead) for expanded cardiac coverage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed wireless acquisition for patient comfort and mobility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eDX12 Bluetooth transmitter: 113 g, ≥12 h battery, no leadwires to the PC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed a PC-based platform that leverages existing computer hardware\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSoftware-driven acquisition via USB or Bluetooth; no dedicated ECG cart required for every room\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed interpretation support with clear advisory labeling\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eGlasgow interpretation; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e per FDA labeling\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed HIS\/EMR\/PACS integration and multi-format export\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePDF\/XML\/SCP\/DICOM\/JPG export; HL7, DICOM, GDT connectivity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed centralized data management across cardiac modalities\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eOptional Holter (SE-2003\/SE-2012\/SE-3012), ABP (SA-10), and Holter \u0026amp; ABP 2-in-1 (SA-20) analysis upgrades\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed FDA and CE regulatory coverage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eFDA K152427; CE-marked; IEC 60601-1, IEC 60601-1-2, IEC 60601-2-25 compliant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46507484577836,"sku":null,"price":1499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/EdanSE-1515PCECG.png?v=1793018368","url":"https:\/\/www.globalhealthcaremedical.com\/products\/edan-se-1515-pc-ecg","provider":"Global Healthcare Medical","version":"1.0","type":"link"}