{"product_id":"edan-se-2003a-holter-recorder","title":"EDAN SE-2003A Holter Recorder","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEDAN SE-2003A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3-channel digital Holter recorder\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in EDAN’s \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSE-2003\/SE-2012 Holter System\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e family, designed for continuous ambulatory ECG recording in adult and pediatric patients, including infants weighing less than 10 kg. It shares the core recording architecture of the SE-2003, with one practical distinction: the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSE-2003A records to a standard SD card\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, while the SE-2003 uses a micro-SD card\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-2003A captures \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3-channel ECG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e at sampling rates of \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e128–1024 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and stores data on a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eremovable SD card\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for transfer to EDAN’s \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHolter Analysis Software\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e via USB or card reader. Recording capacity reaches \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24–96 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e on a standard AAA alkaline battery, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eup to 7 days\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e when paired with a Li-Fe battery—supporting extended rhythm surveillance without frequent device changes\u003c\/span\u003e\u003cspan class=\"\"\u003e. The recorder is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIP27-rated\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for water and dust protection, includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e1.92-inch OLED screen with real-time waveform display\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and provides a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epatient event marker\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for flagging symptomatic episodes during the wear period\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"3\"\u003e\u003ca href=\"http:\/\/edanusa.com\/wp-content\/uploads\/sites\/12\/2019\/04\/SE-2003-SE-2012-Holter-System-Brochure-1.pdf#1#1\" rel=\"noreferrer\" aria-label=\"6\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-2003\/SE-2012 Holter System received \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA 510(k) clearance under K151787 (January 27, 2016)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e . The cleared intended use covers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003erecording, analysis, display, editing, and report generation of ambulatory ECG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with analysis results offered to physicians \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eon an advisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The system’s cleared indications include \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eevaluation of symptoms suggesting arrhythmia or myocardial ischemia, ST segment changes, drug response in patients taking anti-arrhythmic medications, and patients with pacemakers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The SE-2003A is the SD-card variant within this cleared system family; confirm local registration and labeling for the specific model before purchase.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"4\"\u003e\u003ca href=\"https:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf15\/K151787.pdf#3#1\" rel=\"noreferrer\" aria-label=\"11\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-2003A is built for facilities that need \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ea lightweight, waterproof, extended-recording Holter recorder with standard SD card convenience\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, paired with a mature analysis platform for arrhythmia, ST segment, atrial fibrillation, HRV, HRT, and pacemaker review.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eStandard SD Card Storage for Practical Workflow\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-2003A records to a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estandard SD card\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, distinguishing it from the micro-SD format used on the SE-2003\u003c\/span\u003e\u003cspan class=\"\"\u003e. For departments that already standardize on SD card readers or prefer the handling characteristics of full-size SD media, this simplifies data transfer between the recorder and the analysis workstation. Recordings can be downloaded via \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSD card reader or direct USB connection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e to the Holter software\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"6\"\u003e\u003ca href=\"http:\/\/edanusa.com\/wp-content\/uploads\/sites\/12\/2019\/04\/SE-2003-SE-2012-Holter-System-Brochure-1.pdf#1#1\" rel=\"noreferrer\" aria-label=\"6\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eUp to 7 Days of Recording on a Single Battery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eWith a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estandard AAA alkaline battery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, the SE-2003A records \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3-channel, full-disclosure, non-compressed ECG for 24–96 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. With a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLi-Fe battery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, recording extends to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e7 days\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. This extended capacity supports longer monitoring windows when intermittent or low-frequency events are being evaluated, without requiring device replacement during the wear period.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eIP27 Water and Dust Protection with Lightweight Design\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe recorder carries an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIP27 rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for water and dust ingress protection, supporting cleaning between patients and reducing the risk of accidental water damage during daily wear—including use in the shower\u003c\/span\u003e\u003cspan class=\"\"\u003e. At approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e50 g (excluding battery)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , it is designed to minimize patient burden during multi-day recordings\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"8\"\u003e\u003ca href=\"http:\/\/edanusa.com\/wp-content\/uploads\/sites\/12\/2019\/04\/SE-2003-SE-2012-Holter-System-Brochure-1.pdf#1#1\" rel=\"noreferrer\" aria-label=\"6\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.teamalex-medical.com\/index.php?controller=attachment\u0026amp;id_attachment=1440#1#1\" rel=\"noreferrer\" aria-label=\"8\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eReal-Time Waveform Display and Event Marker\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOLED screen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ereal-time waveform display\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, allowing the clinician to confirm signal quality at hook-up and during recording without waiting for post-processing. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epatient event marker\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e lets the wearer flag symptomatic episodes—such as palpitations, dizziness, or exercise onset—so those periods receive focused attention during review\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"11\"\u003e\u003ca href=\"https:\/\/www.doccheckshop.eu\/p\/102216-0-se-2003a-ecg-recorder\/#cs-productsSameCategory-tab-pane\" rel=\"noreferrer\" aria-label=\"5\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eHolter Analysis Software with Multi-Parameter Review\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe included \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHolter Analysis Software\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efull-disclosure review of 24\/48\/96-hour and 6-day ECG data\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003earrhythmia analysis, ST-segment analysis, atrial fibrillation\/flutter analysis, heart rate variability (HRV), heart rate turbulence (HRT), and pacemaker detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Graphical assistive tools include \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eR-R histograms, waveform superposition heat maps, and Lorenz plots\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for locating and selecting abnormal beats during long recordings. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecustomizable toolbar\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports user-defined workflow organization.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"12\"\u003e\u003ca href=\"http:\/\/edanusa.com\/wp-content\/uploads\/sites\/12\/2019\/04\/SE-2003-SE-2012-Holter-System-Brochure-1.pdf#1#1\" rel=\"noreferrer\" aria-label=\"6\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003ePacemaker Detection Under Cleared Indications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-2003A supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epacemaker pulse detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, aligning with the system’s cleared indication for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eevaluation of patients with pacemakers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. This allows the same platform to serve both general arrhythmia evaluation and pacemaker patient follow-up.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"13\"\u003e\u003ca href=\"https:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf15\/K151787.pdf#3#1\" rel=\"noreferrer\" aria-label=\"11\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eOptional Advanced Analysis Upgrades\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eOptional software modules extend the analysis toolkit with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVector ECG, Ventricular Late Potentials, T-wave Alternans, and Waterfall Plot\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e functions, allowing departments to tailor the platform to specific clinical or research interests.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDevice Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e3-channel digital Holter recorder with analysis software\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eModel Distinction\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSE-2003A records to standard SD card (SE-2003 uses micro-SD)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRecording Channels\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e3-channel ECG (7-electrode or 5-electrode configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRecording Duration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e24–96 hours with AAA alkaline battery; up to 7 days with Li-Fe battery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eStorage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eStandard SD card\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eOLED screen with real-time waveform display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSampling Rate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e128–1024 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eA\/D Conversion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e8, 12, 16, 18-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFrequency Response\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.05–60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInput Impedance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≥ 20 MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSingle AAA battery (alkaline or Li-Fe)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIngress Protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eIP27 (water and dust protected)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eApproximately 50 g (excluding battery); 75 g per some published listings\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eApproximately 68 × 53 × 16 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEvent Marker\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eYes, patient-activated event marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePacemaker Detection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSupported\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSoftware Functions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eFull disclosure (24\/48\/96 h, 6 days); arrhythmia analysis; ST analysis; AFib\/Flutter analysis; HRV; HRT; pacemaker analysis; R-R Histogram; Waveform Superposition Heat Map; Lorenz Plot; customizable toolbar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOptional Upgrades\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eVector ECG; Ventricular Late Potentials; T-wave Alternans; Waterfall Plot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Patient Population\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAdult and pediatric patients, including infants weighing less than 10 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Use\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eRecording, analysis, display, editing, and report generation of ambulatory ECG; analysis results advisory only; use by trained personnel under physician direction (SE-2003\/SE-2012 Holter System, FDA 510(k) K151787)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRegulatory Status\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSE-2003\/SE-2012 Holter System FDA 510(k) cleared (K151787, January 27, 2016); SE-2003A is the SD-card variant within this system family; availability and cleared claims vary by market\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the EDAN SE-2003A?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eClinical or Operational Challenge\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSE-2003A Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed standard SD card storage for department workflow\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eRecords to standard SD card, with USB or card-reader transfer to analysis software\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed extended recording for intermittent events\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eUp to 96 hours on AAA alkaline, up to 7 days on Li-Fe battery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePatients need a lightweight, waterproof recorder\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eApproximately 50 g, IP27-rated for water and dust, including shower use\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed to confirm signal quality at setup and during wear\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eOLED screen with real-time waveform display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed to flag symptomatic episodes for focused review\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePatient-activated event marker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed a mature analysis platform for arrhythmia, ST, AFib, HRV, and pacemaker review\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eHolter Analysis Software with full disclosure, multiple analysis modules, and graphical review tools\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed to match existing ECG cable formats\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eCompatible with 7-electrode and 5-electrode cables in IEC or AHA configurations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed to extend analysis for specific clinical interests\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eOptional Vector ECG, Ventricular Late Potentials, T-wave Alternans, and Waterfall Plot upgrades\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46436814258220,"sku":null,"price":2999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/EdanSE-2003AHolterRecorder.png?v=1792592094","url":"https:\/\/www.globalhealthcaremedical.com\/products\/edan-se-2003a-holter-recorder","provider":"Global Healthcare Medical","version":"1.0","type":"link"}