{"product_id":"edan-se-2012a-holter-recorder","title":"EDAN SE-2012A Holter Recorder","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEDAN SE-2012A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estandard-SD-card variant of the 12-channel \/ 3-channel SE-2012 recorder\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e within EDAN’s \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSE-2003\/SE-2012 Holter System\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e family. It is designed for extended ambulatory ECG recording in adult and pediatric patients, including infants weighing less than 10 kg, and shares the dual-mode recording architecture that distinguishes the SE-2012 line: \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efull-disclosure 12-lead ECG for 24–48 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, or \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3-channel ECG for 24–96 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, on a single AAA alkaline battery\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"1\"\u003e\u003ca href=\"https:\/\/imda.moh.gov.vn\/documents\/10182\/69312373\/upload_00000175_1749849623456.pdf?version=1.0\u0026amp;fileId=69313251#5#2\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe key practical distinction between the SE-2012A and the SE-2012 lies in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estorage media\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The SE-2012 accepts \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emicro-SD cards\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSE-2012A accepts standard SD cards\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—a difference that can matter for departments that already standardize on full-size SD readers or prefer the handling characteristics of standard SD media during transfer between recorder and analysis workstation\u003c\/span\u003e\u003cspan class=\"\"\u003e. The SE-2012A also has a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elarger enclosure (92 × 56 × 20 mm) and a higher weight (75 g without battery)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e compared with the SE-2012 (76 × 49 × 16 mm, 50 g), reflecting the physical accommodation of the standard SD card slot\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"2\"\u003e\u003ca href=\"https:\/\/imda.moh.gov.vn\/documents\/10182\/69312373\/upload_00000175_1749849623456.pdf?version=1.0\u0026amp;fileId=69313251#5#2\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/solicmedical.com\/pdf\/82-01.54.456542-1.3%20SE-2003\u0026amp;SE-2012%20Series%20Holter%20System%20Recorder%20User%20Manual_French-ES.pdf#6#6\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-2003\/SE-2012 Holter System received \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA 510(k) clearance under K151787 (January 27, 2016)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e . The cleared trade name lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSE-2003 and SE-2012\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and the cleared intended use covers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003erecording, analysis, display, editing, and report generation of ambulatory ECG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with analysis results offered \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eon an advisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The SE-2012A is the standard-SD variant within this system family; confirm local registration and model-specific labeling before purchase.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"4\"\u003e\u003ca href=\"https:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf15\/K151787.pdf#3#1\" rel=\"noreferrer\" aria-label=\"11\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-2012A is built for facilities that need \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ethe 12-lead depth and extended recording capacity of the SE-2012 platform with standard SD card convenience\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, paired with a mature analysis suite covering \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003earrhythmia, ST segment, atrial fibrillation, HRV, HRT, and pacemaker detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eStandard SD Card Storage for Department Workflow\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-2012A records to a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estandard SD card\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, while the SE-2012 uses a micro-SD card\u003c\/span\u003e\u003cspan class=\"\"\u003e. For departments that already use full-size SD card readers, or that prefer handling standard SD media during data transfer, the SE-2012A aligns with that workflow without requiring an adapter. Recordings can be downloaded via \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSD card reader or direct USB connection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e to the Holter analysis software.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"5\"\u003e\u003ca href=\"https:\/\/imda.moh.gov.vn\/documents\/10182\/69312373\/upload_00000175_1749849623456.pdf?version=1.0\u0026amp;fileId=69313251#5#2\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eDual-Mode Recording: 12-Lead Depth or Extended 3-Channel Duration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-2012A supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ethree lead configurations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e: \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e10-electrode standard 12-lead\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e7-electrode 3-channel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5-electrode 3-channel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. In 12-lead mode, it records \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003enon-compressed, full-disclosure ECG for 24–48 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; in 3-channel mode, recording extends to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24–96 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e on a standard AAA alkaline battery\u003c\/span\u003e\u003cspan class=\"\"\u003e. This allows one recorder to serve both detailed 12-lead studies and longer rhythm surveillance without purchasing a second device.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"7\"\u003e\u003ca href=\"https:\/\/imda.moh.gov.vn\/documents\/10182\/69312373\/upload_00000175_1749849623456.pdf?version=1.0\u0026amp;fileId=69313251#5#2\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eIP27 Water and Dust Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-2012A carries an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIP27 rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for water and dust ingress protection, supporting cleaning between patients and reducing the risk of accidental water damage during daily wear, including shower use. The recorder is designed to be worn with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecarry belt\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (included) during the recording period.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eReal-Time Waveform Display and Patient Event Marker\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe recorder includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e1.92-inch full-color OLED screen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ereal-time waveform display\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, allowing signal-quality confirmation at hook-up and during recording without waiting for post-processing\u003c\/span\u003e\u003cspan class=\"\"\u003e. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epatient event marker (confirmation key)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e lets the wearer flag symptomatic episodes or meaningful timestamps—such as exercise onset or sleep—so those periods receive focused attention during review\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"8\"\u003e\u003ca href=\"https:\/\/imda.moh.gov.vn\/documents\/10182\/69312373\/upload_00000175_1749849623456.pdf?version=1.0\u0026amp;fileId=69313251#5#2\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/solicmedical.com\/pdf\/82-01.54.456542-1.3%20SE-2003\u0026amp;SE-2012%20Series%20Holter%20System%20Recorder%20User%20Manual_French-ES.pdf#6#6\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eHolter Analysis Software with Multi-Parameter Review\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe included \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHolter Analysis Software\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efull-disclosure review, automatic and manual editing, arrhythmia analysis, ST-segment analysis, atrial fibrillation\/flutter analysis, HRV, HRT, and pacemaker detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Graphical assistive tools include \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eR-R histograms, waveform superposition heat maps, and Lorenz plots\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for locating abnormal beats during long recordings. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecustomizable toolbar\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports user-defined workflow organization.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003ePacemaker Detection Under Cleared Indications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-2012A supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epacemaker pulse detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, aligning with the system’s cleared indication for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eevaluation of patients with pacemakers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Detection parameters include amplitude ranges of approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e±1 mV to ±200 mV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and pulse widths of \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e0.1 ms to 2.0 ms\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, per published performance specifications\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"10\"\u003e\u003ca href=\"https:\/\/solicmedical.com\/pdf\/82-01.54.456542-1.3%20SE-2003\u0026amp;SE-2012%20Series%20Holter%20System%20Recorder%20User%20Manual_French-ES.pdf#6#6\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/imda.moh.gov.vn\/documents\/10182\/75785821\/upload_00007418_1762767347505.pdf?version=1.0\u0026amp;fileId=75821976#3#1\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eOptional Advanced Analysis Upgrades\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eOptional software modules extend the analysis toolkit with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVector ECG, Ventricular Late Potentials, T-wave Alternans, and Waterfall Plot\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e functions, allowing departments to tailor the platform to specific clinical or research interests.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDevice Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12-channel \/ 3-channel digital Holter recorder with analysis software\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eModel Distinction\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSE-2012A records to standard SD card (SE-2012 uses micro-SD)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRecording Modes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e10-electrode 12-lead; 7-electrode 3-channel; 5-electrode 3-channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12-Lead Recording Duration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e24–48 hours, non-compressed, full-disclosure (AAA alkaline)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3-Channel Recording Duration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e24–96 hours, non-compressed, full-disclosure (AAA alkaline)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eStorage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eStandard SD card\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1.92-inch full-color OLED with real-time waveform display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBattery\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSingle AAA (alkaline, Li-Fe, or Ni-MH); Li-Fe recommended for extended use\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIngress Protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eIP27 (water and dust protected)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e75 g (excluding battery), ±5 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e92 × 56 × 20 mm, ±2 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFrequency Response\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.05–100 Hz (-3 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInput Impedance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≥ 50 MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCMRR\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≥ 100 dB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eA\/D Sampling\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e25.6 kHz, 24-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePacemaker Detection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e±1 mV ~ ±200 mV amplitude; 0.1 ms ~ 2.0 ms pulse width\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eData Transfer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eUSB cable or SD card reader\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSoftware Functions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eFull disclosure; arrhythmia analysis; ST analysis; AFib\/Flutter analysis; HRV; HRT; pacemaker analysis; R-R Histogram; Waveform Superposition Heat Map; Lorenz Plot; customizable toolbar\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOptional Upgrades\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eVector ECG; Ventricular Late Potentials; T-wave Alternans; Waterfall Plot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Patient Population\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAdult and pediatric patients, including infants weighing less than 10 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Use\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eRecording, analysis, display, editing, and report generation of ambulatory ECG; analysis results advisory only; use by trained personnel under physician direction (SE-2003\/SE-2012 Holter System, FDA 510(k) K151787)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRegulatory Status\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSE-2003\/SE-2012 Holter System FDA 510(k) cleared (K151787, January 27, 2016); SE-2012A is the standard-SD variant within this system family; availability and cleared claims vary by market\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the EDAN SE-2012A?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eClinical or Operational Challenge\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSE-2012A Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDepartment standardizes on standard SD cards for Holter data\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eRecords to standard SD card; direct transfer via SD reader or USB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed both 12-lead depth and extended rhythm surveillance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12-lead for 24–48 hours, or 3-channel for 24–96 hours\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed to confirm signal quality at setup and during recording\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1.92-inch OLED with real-time waveform display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed to flag symptomatic episodes for focused review\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePatient-activated event marker\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed a mature analysis platform for arrhythmia, ST, AFib, HRV, and pacemaker review\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eHolter Analysis Software with full disclosure, multiple analysis modules, and graphical tools\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed pacemaker evaluation capability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePacemaker detection supported under cleared indications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed to match existing ECG cable formats\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12-lead, 7-electrode, and 5-electrode cables in IEC or AHA configurations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed to extend analysis for specific clinical interests\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eOptional Vector ECG, Ventricular Late Potentials, T-wave Alternans, and Waterfall Plot upgrades\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46436848762924,"sku":null,"price":3199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/EdanSE-2012AHolter.png?v=1792592378","url":"https:\/\/www.globalhealthcaremedical.com\/products\/edan-se-2012a-holter-recorder","provider":"Global Healthcare Medical","version":"1.0","type":"link"}