{"product_id":"edan-se-3-3-channel-electrocardiograph-color-screen","title":"EDAN SE-3 3-Channel Electrocardiograph (Color Screen)","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEDAN SE-3 (Color Screen)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecompact, portable 3-channel resting electrocardiograph\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e designed for routine 12-lead ECG acquisition in hospitals, clinics, and primary care settings. It combines the core SE-3 acquisition and recording platform with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3.9-inch, 320 × 240-pixel color LCD screen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, bringing color-coded waveform differentiation and menu navigation to a device that remains small enough to carry between examination rooms and bedside locations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-3 acquires \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eall 12 leads simultaneously\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e through body surface electrodes, then outputs \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3-channel reports on an integrated high-resolution thermal printer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e using \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e80 mm × 20 m rolled or 80 × 70 mm × 200-page Z-fold thermal paper\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efoldable color LCD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e displays real-time waveforms before recording, allowing the clinician to confirm signal quality, electrode contact, and baseline stability at the point of acquisition. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRecording modes include AUTO, MANUAL, OFF-AUTO, RHYTHM, OFF-RHYTHM, and R-R\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with the rhythm lead selectable from any of the 12 standard leads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-3 series is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA-cleared under 510(k) K091513 (July 24, 2009)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e as part of the SMART ECG Series Electrocardiograph, with the SE-3, SE-300A, and SE-300B explicitly listed in the clearance. A subsequent clearance under \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eK171943 (September 25, 2017)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e covers the SE-3 Series including the SE-3, SE-300A, SE-300B, and SE-301. The cleared intended use covers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eacquisition of ECG signals from adult and pediatric patients (beginning at birth through 21 years of age) through body surface ECG electrodes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, for use \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ein hospitals or healthcare facilities by doctors and trained healthcare professionals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, to help users \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eanalyze and diagnose heart disease\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECG with measurements and interpretive statements is offered to clinicians on an advisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The FDA summary for K171943 explicitly notes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e“No clinical data”\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; evidence consisted of non-clinical bench testing including electrical safety (IEC 60601-1), EMC (IEC 60601-1-2), performance testing per IEC 60601-2-25, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECG interpretation features validated via database testing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe signal chain includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12-bit or 24-bit A\/D resolution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einput impedance ≥ 50 MΩ (10 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efrequency response 0.05–150 Hz (−3 dB)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCMRR ≥ 110 dB (≥ 115 dB optional)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eselectable digital filters\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for AC (on\/off), DFT (0.05\/0.15\/0.25\/0.32\/0.5\/0.67 Hz), EMG (25\/35\/45 Hz\/off), and low-pass (150\/100\/75 Hz). \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePacemaker detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is available with an optional board.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003ePower is supplied by \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAC mains (100–115 V \/ 220–240 V, 50\/60 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e or a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebuilt-in rechargeable lithium-ion battery (14.8 V)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emore than 3 hours of continuous recording\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e cited in product documentation (and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emore than 6 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e of continuous operation referenced in other distributor specifications). \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInternal storage holds 500 ECG records\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with data transfer via \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEthernet, RS232, or USB\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePDF, DICOM, SCP, and XML\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e report formats.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-3 is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass I with internal power supply, Type CF, defibrillation-proof\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, designed to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIEC 60601-1:2005\/A1:2012, IEC 60601-1-2:2007, and IEC 60601-2-25:2011\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e standards, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE marked as a Class IIa device (Rule 10)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e under MDD 93\/42\/EEC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-3 (Color Screen) is built for facilities that need \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ean FDA-cleared, CE-marked 3-channel ECG device with a color preview display, simultaneous 12-lead acquisition, integrated thermal printing, and battery-backed portability\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—with the clarity of a color screen and the option to add pacemaker detection when needed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e3.9-Inch Color LCD for Waveform Differentiation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e320 × 240-pixel color LCD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e displays the ECG waveform in real time before recording, with color differentiation across traces and menu elements for easier visual parsing. The screen folds down when not in use, reducing the device footprint during transport and storage. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSelectable display languages\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e include GB, IT, FR, ES, RU, PL, CZ, RO, DE, TR, HR, and UA.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSimultaneous 12-Lead Acquisition with 3-Channel Output\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-3 acquires \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eall 12 leads simultaneously\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e through body surface electrodes, then presents and prints them as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3-channel reports\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e4 pages in series to output all 12 leads\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The full 12-lead set is captured in one acquisition pass, while the printed format remains manageable on 80 mm thermal paper. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLead selection and rhythm lead\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e are user-configurable from any of the 12 standard leads.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eBuilt-In High-Resolution Thermal Printer\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintegrated thermal printer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e produces 3-channel ECG recordings on \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e80 mm × 20 m rolled or 80 × 70 mm × 200-page Z-fold thermal paper\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with selectable paper speeds of \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5, 6.25, 10, 12.5, 25, or 50 mm\/s (±3%)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The printer is part of the main unit, so acquisition and hard-copy documentation happen in a single step. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12-lead grid printing on normal A4 paper\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is also supported through an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eexternal printer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSix Recording Modes for Flexible Workflow\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-3 supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAUTO, MANUAL, OFF-AUTO, RHYTHM, OFF-RHYTHM, and R-R recording modes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, allowing the user to choose between pre-configured acquisition sequences, full manual control, rhythm strips, and R-R interval recording. This flexibility supports both experienced ECG technicians and staff who perform ECGs intermittently.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSelectable Digital Filters and Optional Pacemaker Detection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-3 applies \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAC filtering (on\/off)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDFT filtering (0.05\/0.15\/0.25\/0.32\/0.5\/0.67 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEMG filtering (25\/35\/45 Hz\/off)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elow-pass filtering (150\/100\/75 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e to support trace readability across different recording environments. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePacemaker detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is available with an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional board\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, supporting use in patients with implanted pacemakers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSEMIP Interpretation with Advisory Labeling\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-3 includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic ECG measurements and interpretation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, processed by the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSEMIP algorithm (V1.7 or V1.8)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Per the cleared labeling under \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eK091513 \/ K171943\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECG with measurements and interpretive statements is offered to clinicians on an advisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—it supports, but does not replace, clinician analysis and diagnosis. EDAN’s product literature notes the interpretation function is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etested with CSE\/AHA\/MIT databases\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and the FDA summary confirms \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECG interpretation features were validated via database testing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e500 ECG Internal Storage with Multi-Interface Export\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-3 stores \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eup to 500 ECG records\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e internally, with data transfer to a PC via \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEthernet, RS232, or USB\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Reports can be exported in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePDF, DICOM, SCP, and XML\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e formats. Integration with the optional \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSE-1515 Data Management System\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e enables centralized review and paperless workflow where configured.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eRechargeable Li-Ion Battery with AC\/DC Power\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebuilt-in rechargeable lithium-ion battery (14.8 V, 2200 mAh)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emore than 3 hours of continuous recording\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e per one distributor specification, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emore than 6 hours of continuous operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e per another. The device can also run on \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAC mains (100–115 V \/ 220–240 V, 50\/60 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with automatic switching between power sources.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSafety Classification: Class I, Type CF, Defibrillation-Proof\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-3 is classified as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass I with internal power supply, Type CF (defibrillation-proof applied part)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e under \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIEC 60601-1\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The patient connection is fully isolated, and the device is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edefibrillation-proof\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, supporting use in settings where defibrillation may occur.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDevice Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e3-channel resting electrocardiograph (Color Screen configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA Clearance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eK091513 (July 24, 2009; SE-3 explicitly listed); K171943 (September 25, 2017)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAcquisition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12 leads simultaneous via body surface electrodes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e3.9-inch color LCD, 320 × 240 pixels; foldable; real-time waveform preview\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePrinter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eBuilt-in thermal dot-matrix recorder; 80 mm × 20 m roll or 80 × 70 mm × 200-page Z-fold\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePaper Speed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e5, 6.25, 10, 12.5, 25, 50 mm\/s (±3%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSensitivity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e2.5, 5, 10, 20 mm\/mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInput Impedance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≥ 50 MΩ (10 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFrequency Response\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.05–150 Hz (−3 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCMRR\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≥ 110 dB (≥ 115 dB optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eA\/D Resolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12-bit or 24-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFilters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAC on\/off; DFT 0.05\/0.15\/0.25\/0.32\/0.5\/0.67 Hz; EMG 25\/35\/45 Hz\/off; Low-pass 150\/100\/75 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRecording Modes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAUTO, MANUAL, OFF-AUTO, RHYTHM, OFF-RHYTHM, R-R\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRhythm Lead\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAny lead selectable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePacemaker Detection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAvailable with optional board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInterpretation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eSEMIP algorithm (V1.7\/V1.8); interpretation tested with CSE\/AHA\/MIT databases; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e per cleared labeling\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInternal Storage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e500 ECG records\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eData Transfer \/ Export\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eEthernet, RS232, USB; PDF, DICOM, SCP, XML\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAC 100–115 V \/ 220–240 V, 50\/60 Hz; built-in rechargeable Li-ion battery (14.8 V, 2200 mAh)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBattery Operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e\u0026gt;3 hours continuous recording (one spec); \u0026gt;6 hours continuous operation (alternate spec)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e290 × 220 × 85 mm (per product datasheet); 288 × 210 × 70 mm (alternate distributor spec)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e2.5 kg without battery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSafety Classification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eClass I, internal power supply, Type CF, defibrillation-proof\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSafety Standards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eIEC 60601-1:2005\/A1:2012; EN 60601-1:2006\/A1:2013; IEC 60601-1-2:2007; EN 60601-1-2:2007\/AC:2010; IEC 60601-2-25:2011\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE Marking\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eClass IIa, Rule 10, MDD 93\/42\/EEC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Patient Population\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAdult and pediatric patients (beginning at birth through 21 years of age)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Use\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eAcquisition of ECG signals via body surface electrodes to help analyze and diagnose heart disease in hospitals or healthcare facilities by doctors and trained healthcare professionals; ECG with measurements and interpretive statements offered on an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the EDAN SE-3 (Color Screen)?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eClinical or Operational Challenge\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSE-3 (Color Screen) Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed FDA-cleared 3-channel ECG with a color preview display\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSE-3 explicitly listed in K091513 and K171943; 3.9-inch color LCD for waveform differentiation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed simultaneous 12-lead acquisition with compact 3-channel output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12-lead simultaneous acquisition; 3-channel printing on 80 mm paper, 4 pages for all 12 leads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed integrated thermal printing at the point of care\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eBuilt-in high-resolution thermal printer; multiple paper speed options; A4 grid printing via external printer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed flexible recording control for different workflows\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSix recording modes: AUTO, MANUAL, OFF-AUTO, RHYTHM, OFF-RHYTHM, R-R\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed pacemaker compatibility when required\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eOptional pacemaker detection board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed filtering to manage baseline drift, AC, and EMG artifacts\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSelectable AC, DFT, EMG, and low-pass digital filters with automatic baseline adjustment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed to know when an electrode loses contact\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLead-off detection and alarm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed portability with battery backup\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eBuilt-in rechargeable Li-ion battery; AC\/DC power; \u0026gt;3 hours continuous recording\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed storage and export flexibility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e500 ECG records; Ethernet\/USB\/RS232; PDF\/DICOM\/SCP\/XML export\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46461751623724,"sku":null,"price":1399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/EDANSE-33-ChannelElectrocardiograph_ColorScreen.png?v=1792771090","url":"https:\/\/www.globalhealthcaremedical.com\/products\/edan-se-3-3-channel-electrocardiograph-color-screen","provider":"Global Healthcare Medical","version":"1.0","type":"link"}