{"product_id":"edan-se-300a-basic-3-channel-electrocardiograph-monochrome-screen","title":"EDAN SE-300A Basic 3-Channel Electrocardiograph (Monochrome Screen)","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEDAN SE-300A Basic\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecompact, portable 3-channel resting electrocardiograph\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e designed for routine 12-lead ECG acquisition in hospitals, clinics, and primary care settings. The Basic configuration pairs the core SE-300A acquisition and recording platform with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emonochrome LCD screen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, providing essential waveform preview and thermal printing functions at the entry point of EDAN's 3-channel ECG line\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"1\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-300A acquires \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eall 12 leads simultaneously\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e through body surface electrodes, then outputs \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3-channel reports on an 80 mm thermal printer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e4 pages in series to cover all 12 leads\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efoldable monochrome LCD screen (320 × 240 pixels)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e displays real-time waveforms before recording, allowing the clinician to confirm signal quality and electrode contact at the point of acquisition\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"2\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-300A series is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA-cleared under 510(k) K091513 (July 24, 2009)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e as part of the SMART ECG Series Electrocardiograph, with the SE-3, SE-300A, and SE-300B models explicitly listed in the clearance\u003c\/span\u003e\u003cspan class=\"\"\u003e. A subsequent clearance under \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eK171943 (September 25, 2017)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e covers the SE-3 Series including the SE-300A\u003c\/span\u003e\u003cspan class=\"\"\u003e. The cleared intended use covers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eacquisition of ECG signals from adult and pediatric patients (beginning at birth through 21 years of age) through body surface ECG electrodes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, for use \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ein hospitals or healthcare facilities by doctors and trained healthcare professionals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, to help users \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eanalyze and diagnose heart disease\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECG with measurements and interpretive statements is offered to clinicians on an advisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"4\"\u003e\u003ca href=\"https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?id=K091513\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/device\/K171943\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-300A Basic is built around \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecomplete digital filtering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—EMG filter (25\/35\/45 Hz or off), DFT filter (0.05\/0.15\/0.25\/0.35\/0.5\/0.67 Hz), low-pass filter (150\/100\/75 Hz), and AC filter (on\/off)—with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic baseline adjustment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e to counter drift during recording. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLead-off detection and alarm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e notify the user when an electrode loses contact. The device supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAuto, Manual, Rhythm, and R-R recording modes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with the rhythm lead selectable from any of the 12 standard leads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003ePower is supplied by a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebuilt-in rechargeable lithium-ion battery (14.8 V)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e or \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAC mains (100–115 V \/ 220–240 V, 50\/60 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapproximately 6.5 hours of normal operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e on battery, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eabout 3 hours of continuous recording in Manual mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e330 reports in AUTO mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Internal storage holds \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eup to 500 ECG records\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, expandable via USB flash disk. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ewaterproof membrane keyboard\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports routine wipe-down between patients, and the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e300 × 260 × 75 mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e enclosure weighs approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e2.5 kg (excluding battery and recorder paper)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"7\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-300A is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass I with internal power supply, Type CF, defibrillation-proof\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, designed to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIEC 60601-1:2005\/A1:2012, IEC 60601-1-2:2007, and IEC 60601-2-25\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e standards\u003c\/span\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE marked as a Class IIa device (Rule 10)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e through \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTÜV SÜD (CE 0123)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. It is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003enot suitable for use in the presence of flammable anesthetics\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"9\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/3856721\/Edan-Se-300-Series.html?page=81\" rel=\"noreferrer\" aria-label=\"16\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-300A Basic is built for facilities that need \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ea straightforward, FDA-cleared 3-channel ECG device with simultaneous 12-lead acquisition, integrated thermal printing, multiple recording modes, and battery-backed portability\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—without the color screen of the SE-300B configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSimultaneous 12-Lead Acquisition with 3-Channel Output\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-300A acquires \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eall 12 leads simultaneously\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e through body surface electrodes, then presents and prints them as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3-channel reports\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e4 pages in series to output all 12 leads\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The full 12-lead set is captured in one acquisition pass, while the printed format remains manageable on 80 mm thermal paper. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLead selection and rhythm lead\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e are user-configurable from any of the 12 standard leads.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"12\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eFoldable Monochrome LCD for Pre-Recording Waveform Preview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e320 × 240-pixel monochrome LCD screen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e displays the ECG waveform in real time before recording begins, allowing the clinician to confirm signal quality, electrode contact, and baseline stability at the point of acquisition\u003c\/span\u003e\u003cspan class=\"\"\u003e. The screen folds down when not in use, reducing the device footprint during transport and storage.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"13\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eBuilt-In High-Resolution Thermal Printer\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintegrated thermal printer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e produces 3-channel ECG recordings on \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003erolled 80 mm × 20 m or Z-fold 80 mm × 70 mm × 200-page thermal paper\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with selectable paper speeds of \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5, 6.25, 10, 12.5, 25, or 50 mm\/s (±3%)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The printer is part of the main unit, so acquisition and hard-copy documentation happen in a single step. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12-lead grid printing on normal A4 paper\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is also supported through an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eexternal printer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"14\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eFour Recording Modes: Auto, Manual, Rhythm, and R-R\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-300A supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAuto, Manual, Rhythm, and R-R recording modes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, allowing the user to choose between pre-configured acquisition sequences, full manual control, rhythm strips, and R-R interval recording. This flexibility supports both experienced ECG technicians and staff who perform ECGs intermittently.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eComplete Digital Filtering and Automatic Baseline Adjustment\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-300A applies \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEMG filtering (25\/35\/45 Hz or off)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDFT filtering (0.05\/0.15\/0.25\/0.35\/0.5\/0.67 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elow-pass filtering (150\/100\/75 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAC filtering (on\/off)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , alongside \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic baseline adjustment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e to counter drift during recording. The frequency response is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e0.05–150 Hz (−3 dB)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. These filters are designed to support trace readability without requiring manual re-adjustment between patients.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"15\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSEMIP Interpretation with Advisory Labeling\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-300A includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic ECG measurements and analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, processed by the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSEMIP algorithm (V1.7 or V1.8)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Per the cleared labeling under \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eK091513 \/ K171943\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECG with measurements and interpretive statements is offered to clinicians on an advisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—it supports, but does not replace, clinician analysis and diagnosis\u003c\/span\u003e\u003cspan class=\"\"\u003e. EDAN's product literature notes the interpretation function is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etested with CSE\/AHA\/MIT databases\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and the FDA summary confirms \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECG interpretation features validated via database testing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"16\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/device\/K171943\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eLead-Off Detection and Alarm\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe device includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elead-off detection and alarm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, which alerts the user when a patient electrode is disconnected or making poor contact. This supports acquisition quality by drawing attention to cable or electrode issues before they affect the recording.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eUp to 500 ECG Storage with USB Expansion and Multi-Format Export\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-300A stores \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eup to 500 ECG records\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e internally, with expansion available via \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eUSB flash disk\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Data can be transferred to a PC via \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEthernet, RS232, or USB\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and reports can be exported in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePDF, DICOM, SCP, and XML\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e formats. Integration with the optional \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSE-1515 Data Management System\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e enables centralized review and paperless workflow.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eRechargeable Li-Ion Battery with AC\/DC Power\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebuilt-in rechargeable lithium-ion battery (14.8 V, 2200 mAh)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapproximately 6.5 hours of normal operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eabout 3 hours of continuous recording in Manual mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e330 reports in AUTO mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The device can also run on \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAC mains (100–115 V \/ 220–240 V, 50\/60 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with automatic switching between power sources.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"19\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSafety Classification: Class I, Type CF, Defibrillation-Proof\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe SE-300A is classified as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClass I with internal power supply, Type CF (defibrillation-proof applied part)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e under \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIEC 60601-1\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The patient connection is fully isolated, and the device is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edefibrillation-proof\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, supporting use in settings where defibrillation may occur. It is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003enot suitable for use in the presence of flammable anesthetics\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"20\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/3856721\/Edan-Se-300-Series.html?page=81\" rel=\"noreferrer\" aria-label=\"16\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDevice Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e3-channel resting electrocardiograph (Basic configuration, monochrome screen)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAcquisition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e12 leads simultaneous via body surface electrodes\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"22\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e320 × 240 pixel monochrome LCD; foldable; real-time waveform preview\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"23\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePrinter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eBuilt-in thermal dot-matrix recorder; 80 mm × 20 m roll or 80 mm × 70 mm × 200-page Z-fold\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"24\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePaper Speed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e5, 6.25, 10, 12.5, 25, 50 mm\/s (±3%)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"25\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSensitivity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e2.5, 5, 10, 20 mm\/mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInput Impedance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e\u0026gt; 50 MΩ (10 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFrequency Response\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e0.05–150 Hz (−3 dB)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"26\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTime Constant\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e≥ 3.2 s\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"27\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eA\/D Resolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e12-bit standard; 24-bit optional (with DE12 ECG board)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"28\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFilters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eEMG 25\/35\/45 Hz or off; DFT 0.05\/0.15\/0.25\/0.35\/0.5\/0.67 Hz; Low-pass 150\/100\/75 Hz; AC on\/off\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRecording Modes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAuto, Manual, Rhythm, R-R\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRhythm Lead\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAny lead selectable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInterpretation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eSEMIP algorithm (V1.7\/V1.8); interpretation features validated via database testing; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e per cleared labeling\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"29\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/device\/K171943\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInternal Storage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eUp to 500 ECG records; expandable via USB flash disk\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eData Transfer \/ Export\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eEthernet, RS232, USB; PDF, DICOM, SCP, XML report formats\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eAC 100–115 V \/ 220–240 V, 50\/60 Hz; built-in rechargeable Li-ion battery (14.8 V, 2200 mAh)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"30\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBattery Operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e~6.5 hours normal operation; ~3 hours continuous Manual mode; up to 330 AUTO reports\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"31\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e300 × 260 × 75 mm\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"32\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eApproximately 2.5 kg (excluding battery and recorder paper)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"33\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSafety Classification\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eClass I, internal power supply, Type CF, defibrillation-proof; not for use with flammable anesthetics\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"34\"\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/3856721\/Edan-Se-300-Series.html?page=81\" rel=\"noreferrer\" aria-label=\"16\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSafety Standards\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eIEC 60601-1:2005\/A1:2012; EN 60601-1:2006\/A1:2013; IEC 60601-1-2:2007; EN 60601-1-2:2007\/AC:2010; IEC\/EN 60601-2-25\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"35\"\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/3856721\/Edan-Se-300-Series.html?page=81\" rel=\"noreferrer\" aria-label=\"16\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEMC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eCISPR 11 Group 1, Class A\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"36\"\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/3856721\/Edan-Se-300-Series.html?page=81\" rel=\"noreferrer\" aria-label=\"16\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Patient Population\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eAdult and pediatric patients (beginning at birth through 21 years of age)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"37\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/device\/K171943\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Use\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eAcquisition of ECG signals via body surface electrodes to help analyze and diagnose heart disease in hospitals or healthcare facilities by doctors and trained healthcare professionals; ECG with measurements and interpretive statements offered on an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvisory basis only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"38\"\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/device\/K171943\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRegulatory Status\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eFDA 510(k) cleared (SE-300A: K091513, July 24, 2009; K171943, September 25, 2017)\u003c\/span\u003e\u003cspan class=\"\"\u003e; CE marked under MDD 93\/42\/EEC, Class IIa (Rule 10), TÜV SÜD CE 0123\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"39\"\u003e\u003ca href=\"https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?id=K091513\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/device\/K171943\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the EDAN SE-300A Basic?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eClinical or Operational Challenge\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSE-300A Basic Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed FDA-cleared 3-channel ECG for routine clinical use\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eSE-300A cleared under K091513 and K171943 for adult and pediatric patients\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"42\"\u003e\u003ca href=\"https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?id=K091513\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/fda.innolitics.com\/device\/K171943\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed simultaneous 12-lead acquisition with compact 3-channel output\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003e12-lead simultaneous acquisition; 3-channel printing on 80 mm paper, 4 pages for all 12 leads\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"44\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed a device with preview display before recording\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eFoldable monochrome LCD shows real-time waveform before committing to paper\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"45\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed integrated thermal printing at the point of care\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eBuilt-in thermal dot-matrix recorder; multiple paper speed options\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"46\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed flexible recording control for different workflows\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAuto, Manual, Rhythm, and R-R modes; rhythm lead selectable from any of 12 leads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed filtering to manage baseline drift, AC, and EMG artifacts\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eComplete digital filtering with automatic baseline adjustment\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"47\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed to know when an electrode loses contact\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLead-off detection and alarm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed portability with battery backup\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eBuilt-in rechargeable Li-ion battery; ~6.5 hours operation; AC\/DC power\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"48\"\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/bjhlf\/edan-instruments-se-300-a--b-electrocardiograph-user-manual-appendix-1-technical-specifications#1\" rel=\"noreferrer\" aria-label=\"15\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed storage and export flexibility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eUp to 500 ECG records; USB expansion; PDF\/DICOM\/SCP\/XML export via Ethernet, RS232, or USB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46461246603308,"sku":null,"price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/EdanSE-300ABasic3-ChannelElectrocardiograph_MonochromeScreen.png?v=1792762447","url":"https:\/\/www.globalhealthcaremedical.com\/products\/edan-se-300a-basic-3-channel-electrocardiograph-monochrome-screen","provider":"Global Healthcare Medical","version":"1.0","type":"link"}