{"product_id":"edan-ve-1010-veterinary-pc-ecg","title":"EDAN VE-1010 Veterinary PC ECG","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEDAN VE-1010\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePC-based veterinary ECG solution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e that combines a compact \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDP12 data sampling box\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with dedicated \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVE-1010 VET PC ECG software\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e to turn a compatible Windows computer into a paperless animal ECG workstation. Unlike self-contained ECG devices with built-in screens, the VE-1010 separates acquisition from processing: the sampling box connects to the PC via \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eUSB\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and the software handles waveform display, measurement, report generation, archiving, and data sharing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe system is designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esimultaneous 6\/7-lead acquisition and recording\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, supporting \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eresting ECG examination, surgical monitoring, and routine cardiac screening\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in veterinary practice. The DP12 sampling box measures \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e148 × 100 × 40 mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, weighs \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapproximately 210 g\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and receives power directly from the PC via \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDC 5V USB\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—no separate power adapter or battery is required for the acquisition front-end. ECG data is sampled at \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e1,000 Hz per channel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24-bit A\/D resolution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e0.05–150 Hz frequency response\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einput impedance ≥ 50 MΩ (10 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVE-1010 VET PC ECG software\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic and manual measurement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eheart rate variability analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ereport generation on standard A4, B5, or Letter paper\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e using a general office printer. Reports can be exported in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePDF, WORD, JPG, and BMP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e formats, and transmitted via \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eemail for teleconsultation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e or shared across a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elocal area network (LAN)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e . The software maintains a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edatabase of patient information and ECG traces\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for archiving and recall, supporting a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epaperless and streamlined workflow\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for veterinary clinics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWindows compatibility is a critical consideration for this product.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e The VE-1010 software is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eonly compatible with Windows 7 and Windows XP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (with Windows Vista also referenced in some documentation)\u003c\/span\u003e\u003cspan class=\"\"\u003e. It is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003enot compatible with Windows 10, Windows 11, or macOS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and the system requirements reference older hardware specifications (\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePentium P4 or Celeron D 310 or above, 256 MB RAM, 40 GB HDD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e). Buyers must confirm that a suitable Windows 7\/XP computer is available before purchase.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"1\"\u003e\u003ca href=\"https:\/\/www.hexamed.es\/10526-electrocardiografo-ecg-veterinario-edan-pc-ve-1010-digital-usb.html\" rel=\"noreferrer\" aria-label=\"13\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRegulatory status:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e The VE-1010 is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eveterinary device\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, not a human medical device. No \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA 510(k) clearance specific to the VE-1010\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e was identified in the public FDA database; available records reference \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIEC\/EN 60601-1-1\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e compliance and a general U.S. federal restriction statement, consistent with veterinary equipment labeling. No independent \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE MDR\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e certification specific to this model was identified. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAvailability and labeling vary by market; confirm local import and use requirements before purchase.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe VE-1010 is built for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eveterinarians who want to use an existing compatible PC as the display and processing platform\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, adding \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e6\/7-lead ECG acquisition, digital measurement, report export, and archiving\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e without purchasing a self-contained ECG cart.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003ePC-Based Paperless Workflow: Sampling Box + Dedicated Software\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe VE-1010 separates the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECG acquisition front-end (DP12 sampling box)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e from the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecomputing and display environment (the clinic’s Windows PC)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e . The sampling box connects via \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eUSB\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and is powered by the PC, while the VE-1010 VET PC ECG software provides the waveform display, measurement tools, report templates, and database. This architecture allows clinics to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eleverage existing computer hardware\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e rather than dedicating a standalone ECG device to each examination room.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSimultaneous 6\/7-Lead Acquisition with 24-Bit Signal Chain\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe DP12 sampling box acquires \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e6 or 7 leads simultaneously\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24-bit A\/D resolution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e1,000 Hz per-channel sampling\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einput impedance ≥ 50 MΩ (10 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efrequency response of 0.05–150 Hz (−3 dB)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e . The input circuit is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efloating and defibrillation-protected\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and the system supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic baseline adjustment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e to keep traces readable during recording. These are \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esignal-chain specifications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; clinical value depends on proper electrode placement and clinician review.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eHeart Rate Variability Analysis and Auto\/Manual Measurement\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe VE-1010 software includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic and manual measurement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e tools, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eheart rate variability (HRV) analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced as part of the feature set. HRV analysis is positioned as a tool for assessing autonomic influence on cardiac rhythm, and is presented within the software as an analytical function for clinician interpretation. The software also supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emultiple display modes, including 7×1 and 3×3 layouts\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for the 6-lead mode.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eReport Export in PDF, WORD, JPG, and BMP with Teleconsultation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eECG reports can be generated on \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estandard A4, B5, or Letter paper\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e using a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003egeneral office printer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with paper speeds of \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5, 6.25, 10, 12.5, 25, or 50 mm\/s (±3%)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and gain settings of \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e0.625, 1.25, 2.5, 5, 10, 20, or 40 mm\/mV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Reports can be exported in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePDF, WORD, JPG, and BMP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e formats, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etransmitted via email for teleconsultation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e or shared across a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLAN\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e . This supports remote case discussion and digital recordkeeping without requiring a dedicated thermal printer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003ePatient Database and Complete ECG Archives\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe software maintains a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edatabase of patient information and ECG traces\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for archiving and recall. Storage capacity \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edepends on the PC’s hard drive\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, rather than a fixed internal memory limit, allowing clinics to retain as many records as their computer storage allows. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePet ID, pet name, sex, age, and species\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e can be recorded alongside each ECG for organized retrieval.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eCompact USB-Powered Sampling Box\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDP12 sampling box\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e measures \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e148 × 100 × 40 mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, weighs \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapproximately 210 g\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and is powered directly from the PC via \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eUSB (DC 5V)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e . It is small enough to place beside the patient or on a clip, reducing cable clutter between the animal and the computer. The system includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5-lead veterinary ECG cable (Ø4 mm banana connector, IEC or AHA)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and a set of \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ereusable veterinary clip electrodes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e as standard.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eWindows 7 \/ XP Compatibility: Critical System Requirement\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe VE-1010 software is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eonly compatible with Windows 7 and Windows XP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (with Windows Vista also referenced in some documentation)\u003c\/span\u003e\u003cspan class=\"\"\u003e. It is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003enot compatible with Windows 10, Windows 11, or macOS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The software’s system requirements reference \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePentium P4 or Celeron D 310 or above, 256 MB RAM or above, and 40 GB HDD or above\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Buyers should confirm that a suitable Windows 7\/XP computer is available or can be maintained before purchase, as this is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elegacy operating system environment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"2\"\u003e\u003ca href=\"https:\/\/www.hexamed.es\/10526-electrocardiografo-ecg-veterinario-edan-pc-ve-1010-digital-usb.html\" rel=\"noreferrer\" aria-label=\"13\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eVeterinary-Specific Intended Use\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe VE-1010 is intended for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eveterinary ECG examination\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003enot a human medical device\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. It is designed for use by \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eveterinarians and trained veterinary professionals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eanimal hospitals, clinics, and surgical settings\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eresting ECG examination and surgical monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. It should not be used for human diagnostic purposes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDevice Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePC-based veterinary ECG system (USB sampling box + PC software)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRegulatory Status\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan class=\"\"\u003eVeterinary device; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eno FDA 510(k) specific to VE-1010 identified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; IEC\/EN 60601-1-1 referenced; no independent CE MDR specific to this model identified; confirm local import and use requirements\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAcquisition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e6 or 7 leads simultaneous; standard or Cabrera lead modes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSampling Rate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1,000 Hz per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eA\/D Resolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e24-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFrequency Response\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.05–150 Hz (−3 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTime Constant\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≥ 3.2 s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInput Impedance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≥ 50 MΩ (10 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCMRR\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e\u0026gt; 110 dB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInput Circuit\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eFloating, defibrillation-protected\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInput Voltage Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e\u0026lt; ±5 mVpp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCalibration Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1 mV ± 2%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGain\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.625, 1.25, 2.5, 5, 10, 20, 40 mm\/mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePaper Speed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e5, 6.25, 10, 12.5, 25, 50 mm\/s (±3%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFilters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eEMG 25\/35\/45 Hz\/off; Baseline drift strong\/weak\/off; Low-pass 150\/100\/75 Hz; AC 50\/60 Hz\/off\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHR Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e30–300 BPM, ±1 BPM accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRecording Paper\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eA4 (210×297 mm), B5 (182×257 mm), Letter (216×279 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eReport Export\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePDF, WORD, JPG, BMP; email and LAN transmission\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePC Connection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eUSB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower (Sampling Box)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eDC 5V via USB; input power 1 VA (max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDimensions \/ Weight (DP12)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e148 × 100 × 40 mm; approximately 210 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSoftware Compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eWindows 7 and Windows XP only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (Windows Vista also referenced); \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003enot compatible with Windows 10\/11 or macOS\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePC Requirements\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePentium P4 or Celeron D 310 or above; 256 MB RAM or above; 40 GB HDD or above; at least 2 free USB ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eStandard Accessories\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eDP12 sampling box; VE-1010 software CD; USB sentinel; USB connection cable; 5-lead veterinary ECG cable (IEC or AHA); veterinary clip electrodes (5 pcs); electrode cream; carrying bag; manuals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOptional Accessories\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAdditional ECG cables; clip electrodes; carrying bag; PC trolley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Species\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAnimals (veterinary use)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Use\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePC-based veterinary ECG examination, surgical monitoring, and routine cardiac screening; not for human diagnostic use\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the EDAN VE-1010?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eVeterinary Clinical or Operational Challenge\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eVE-1010 Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWant to use an existing PC as the ECG display and processing platform\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eUSB sampling box + dedicated software; no dedicated ECG cart required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed 6\/7-lead simultaneous acquisition with digital measurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e6\/7-lead simultaneous acquisition; 24-bit A\/D; 1,000 Hz sampling; auto\/manual measurement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed heart rate variability analysis\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eHRV analysis referenced in the software feature set\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed reports on standard office paper, not thermal paper\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eA4\/B5\/Letter printing via general office printer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed to share ECG reports remotely or across the clinic\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePDF\/WORD\/JPG\/BMP export; email teleconsultation; LAN networking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed a patient ECG database without fixed internal memory limits\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePC-dependent storage; record pet ID, name, sex, age, and species\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed a compact, USB-powered acquisition front-end\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eDP12 sampling box: 148×100×40 mm, ~210 g, USB-powered\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed to confirm compatibility with existing IT infrastructure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eWindows 7 \/ XP only\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; confirm PC availability before purchase\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46507652349996,"sku":null,"price":1399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/EDANVE-1010VeterinaryPCECG.png?v=1793020093","url":"https:\/\/www.globalhealthcaremedical.com\/products\/edan-ve-1010-veterinary-pc-ecg","provider":"Global Healthcare Medical","version":"1.0","type":"link"}