{"product_id":"ghm-β2-glycoprotein-1-antibody-elisa-kit-us-96-well-sandwich-elisa-for-quantitative-determination-of-anti-β2gpi-antibodies-in-serum-plasma-96t-kit","title":"GHM β2 Glycoprotein 1 Antibody ELISA Kit US – 96-Well Sandwich ELISA for Quantitative Determination of Anti-β2GPI Antibodies in Serum \u0026 Plasma (96T\/Kit)","description":"\u003cp\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e GHM β2 Glycoprotein 1 Antibody ELISA Kit US\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Global Healthcare Medical\u003c\/p\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Healthcare Medical GHM Beta-2 Glycoprotein 1 Antibody ELISA Kit US\u003c\/strong\u003e is a 96-well enzyme-linked immunosorbent assay (ELISA) designed for the \u003cstrong\u003equantitative determination of antibodies directed against Beta-2 Glycoprotein 1 (β2GPI, also designated apolipoprotein H)\u003c\/strong\u003e in human serum and plasma specimens. β2GPI is an abundant plasma glycoprotein that interacts with negatively charged phospholipid surfaces and participates in coagulation-related pathways; antibodies recognising β2GPI belong to the antiphospholipid antibody family and are widely studied as markers of autoimmune humoral reactivity. Quantitative measurement of anti-β2GPI antibodies is used in research settings to characterize autoantibody profiles, study antiphospholipid antibody reactivity, and investigate autoimmune serology.\u003c\/p\u003e\n\u003cp\u003eThe kit employs a \u003cstrong\u003esandwich ELISA principle\u003c\/strong\u003e with capture antibodies immobilized on the solid phase and enzyme-conjugated detection antibodies in the liquid phase. The assay is configured for a \u003cstrong\u003e50 µL sample volume\u003c\/strong\u003e and a \u003cstrong\u003etotal incubation time of approximately 1.5–2.5 hours\u003c\/strong\u003e (depending on protocol configuration), with absorbance read at \u003cstrong\u003e450 nm\u003c\/strong\u003e using standard microplate ELISA equipment. The kit is supplied in a \u003cstrong\u003e96-test\/box\u003c\/strong\u003e format with an \u003cstrong\u003e18-month shelf life\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntended Use:\u003c\/strong\u003e For \u003cstrong\u003elaboratory research use only\u003c\/strong\u003e. This product is \u003cstrong\u003enot intended for use in diagnostic procedures\u003c\/strong\u003e, \u003cstrong\u003enot for therapeutic use\u003c\/strong\u003e, and \u003cstrong\u003enot for clinical decision-making\u003c\/strong\u003e. Results should be interpreted by qualified laboratory professionals in the context of research applications.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003ch3\u003eSandwich ELISA Principle for Quantitative Anti-β2GPI Detection\u003c\/h3\u003e\n\u003cp\u003eThe assay utilizes a \u003cstrong\u003esandwich ELISA format\u003c\/strong\u003e in which capture antibodies are coated onto the 96-well microplate and enzyme-conjugated detection antibodies are supplied in liquid phase. This configuration supports specific antigen capture and signal generation, enabling quantitative anti-β2GPI determination across serum and plasma matrices. The sandwich design is an established reference format for antibody quantitation and provides a direct relationship between antibody concentration and signal intensity.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSandwich ELISA format\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEstablished principle for quantitative anti-β2GPI determination\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eβ2GPI-specific capture and detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTargeted measurement across serum and plasma\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDirect signal-to-analyte relationship\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eQuantitative results across the assay calibration range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance Aligned with Published Anti-β2GPI ELISA Benchmarks\u003c\/h3\u003e\n\u003cp\u003ePublished performance data for sandwich-format human anti-β2GPI antibody ELISA report \u003cstrong\u003eanalytical sensitivity values in the low unit-per-millilitre range, typically approximately 1–2 U\/mL\u003c\/strong\u003e across referenced configurations. Calibration ranges commonly span \u003cstrong\u003e0–100 U\/mL\u003c\/strong\u003e to \u003cstrong\u003e0–300 RU\/mL\u003c\/strong\u003e, depending on platform, calibrator assignment and unit standardization; because anti-β2GPI results are expressed relative to a calibrator rather than as absolute mass concentration, unit definitions vary between referenced configurations. Precision data for these formats indicate \u003cstrong\u003eintra-assay CV values generally below 10%\u003c\/strong\u003e and \u003cstrong\u003einter-assay CV values generally below 12%\u003c\/strong\u003e. Sample volumes of \u003cstrong\u003e50 µL\u003c\/strong\u003e are standard across serum and plasma applications. These reference benchmarks support dependable performance expectations for research-oriented anti-β2GPI quantitation.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eAnalytical sensitivity ~1–2 U\/mL (published benchmark)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupports detection at low antibody concentrations\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration range ~0–100 U\/mL (published benchmark)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBroad coverage across the assay range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIntra-assay CV \u0026lt;10%; inter-assay CV \u0026lt;12% (published benchmark)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRepeatability and reproducibility suitable for laboratory use\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eStandardized 96-Well Workflow with 50 µL Sample Volume\u003c\/h3\u003e\n\u003cp\u003eThe assay is formatted for standard 96-well microplate processing with a \u003cstrong\u003e50 µL sample volume\u003c\/strong\u003e and a \u003cstrong\u003etotal incubation time of approximately 1.5–2.5 hours\u003c\/strong\u003e. Absorbance is measured at \u003cstrong\u003e450 nm\u003c\/strong\u003e, aligning with widely available ELISA readers and washers.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e96 tests\/box\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePractical batch configuration for research workflows\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e50 µL sample volume\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStandard ELISA sample requirement\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e450 nm reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCompatible with common microplate spectrophotometers\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e~1.5–2.5 hour total incubation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEfficient turnaround for batch processing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e18-Month Shelf Life\u003c\/h3\u003e\n\u003cp\u003eExtended reagent stability supports inventory planning and reduces replacement frequency in laboratory settings.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e18-month shelf life\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eExtended inventory stability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eConsistent batch supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupports repeatable research workflows\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Contents \u0026amp; Pricing (EXW US Dollar)\u003c\/h2\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProduct Description\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePackage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eShelf Life\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePrice\/Kit (USD)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCPT (USD\/Test)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eBeta-2 Glycoprotein 1 Antibody ELISA Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e96 Tests\/Box\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e18 Months\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$32.00\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$0.3333\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eCost per test:\u003c\/strong\u003e approximately \u003cstrong\u003e$0.33\u003c\/strong\u003e, based on a 96-test kit configuration.\u003c\/p\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSpecification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDetail\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eModel \/ SKU\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGHM β2 Glycoprotein 1 Antibody ELISA Kit US\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEnzyme-Linked Immunosorbent Assay (ELISA) Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIntended Use\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eQuantitative determination of anti-Beta-2 Glycoprotein 1 (anti-β2GPI) antibodies in human serum or plasma; \u003cstrong\u003efor laboratory research use only; not for use in diagnostic procedures; not for therapeutic use\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAssay Principle\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSandwich ELISA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTarget Analyte\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAnti-Beta-2 Glycoprotein 1 antibody (anti-β2GPI; β2GPI \/ apolipoprotein H)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSpecimen Types\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHuman serum, plasma\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSpecimen Volume\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e50 µL\/well\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePackage Size\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e96 Tests\/Box\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShelf Life\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e18 Months\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eReading Wavelength\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e450 nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTotal Incubation Time\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eApproximately 1.5–2.5 hours (protocol-dependent)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePrecision (published benchmark)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIntra-assay CV \u0026lt;10%; inter-assay CV \u0026lt;12%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAnalytical Sensitivity (published benchmark)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eApproximately 1–2 U\/mL\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCalibration Range (published benchmark)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eApproximately 0–100 U\/mL\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRegulatory Status\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eManufactured under EN ISO 13485 certified quality management system\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhy Laboratories Choose Global Healthcare Medical\u003c\/h2\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConsideration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGHM Beta-2 Glycoprotein 1 Antibody ELISA Kit US\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSandwich ELISA with β2GPI-specific capture and detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTargeted measurement in serum and plasma\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance aligned with published anti-β2GPI ELISA benchmarks\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSensitivity ~1–2 U\/mL; CV \u0026lt;10%\/\u0026lt;12%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eBroad calibration range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e~0–100 U\/mL across referenced configurations\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCost-effective research quantitation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$0.3333 per test; $32.00 per 96-test kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e18-month shelf life\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eExtended inventory stability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eStandard 96-well format\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCompatible with routine ELISA equipment\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eISO 13485 certified\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eQuality management system compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAbout Global Healthcare Medical\u003c\/h2\u003e\n\u003cp\u003eGlobal Healthcare Medical connects clinical laboratories, research institutions, and blood screening centers with diagnostic reagents and analytical systems designed for reliable operation in demanding healthcare environments. The GHM Beta-2 Glycoprotein 1 Antibody ELISA Kit US is part of our professional ELISA reagent portfolio, developed to support standardized, reproducible laboratory workflows.\u003c\/p\u003e\n\u003cp\u003eOur focus is on dependable analytical performance, clear documentation, and responsive support for professional laboratory operations.\u003c\/p\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46767342682156,"sku":null,"price":32.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/2Glycoprotein1AntibodyELISATestKit.png?v=1795504534","url":"https:\/\/www.globalhealthcaremedical.com\/products\/ghm-%ce%b22-glycoprotein-1-antibody-elisa-kit-us-96-well-sandwich-elisa-for-quantitative-determination-of-anti-%ce%b22gpi-antibodies-in-serum-plasma-96t-kit","provider":"Global Healthcare Medical","version":"1.0","type":"link"}