{"product_id":"ghm-aca-anticardiolipin-antibody-igg-elisa-kit-us-96-well-solid-phase-elisa-for-semi-quantitative-determination-of-anticardiolipin-antibody-igg-in-serum-plasma-96t-kit","title":"GHM ACA Anticardiolipin Antibody IgG ELISA Kit US – 96-Well Solid-Phase ELISA for Semi-Quantitative Determination of Anticardiolipin Antibody IgG in Serum \u0026 Plasma (96T\/Kit)","description":"\u003cp\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e GHM ACA Anticardiolipin Antibody IgG ELISA Kit US\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Global Healthcare Medical\u003c\/p\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Healthcare Medical GHM ACA Anticardiolipin Antibody IgG ELISA Kit US\u003c\/strong\u003e is a 96-well enzyme-linked immunosorbent assay (ELISA) designed for the \u003cstrong\u003esemi-quantitative determination of immunoglobulin G (IgG)-class antibodies directed against cardiolipin\u003c\/strong\u003e in human serum and plasma specimens. Anticardiolipin antibodies (ACA, aCL) belong to the \u003cstrong\u003eantiphospholipid antibody family\u003c\/strong\u003e and recognise cardiolipin, a diphosphatidylglycerol species that is an anionic phospholipid enriched in the inner mitochondrial membrane and also exposed on certain membrane surfaces. In solid-phase assays, anticardiolipin antibody binding frequently requires the plasma protein \u003cstrong\u003eβ2-glycoprotein I as a cofactor\u003c\/strong\u003e, so antigen-down formats effectively detect antibodies directed against cardiolipin–β2GPI complexes rather than against the phospholipid alone — a consideration that materially affects assay design and the interpretation of binding signals. The IgG class is a \u003cstrong\u003emonomeric, bivalent immunoglobulin\u003c\/strong\u003e and the most abundant isotype in human serum, accounting for roughly three-quarters of total serum immunoglobulin, with the longest serum half-life of the five classes. IgG arises through class switching and affinity maturation, and it is the predominant isotype of the secondary and memory-phase humoral response. IgG-class anticardiolipin reactivity is studied as one isotype component of \u003cstrong\u003eantiphospholipid antibody profiles\u003c\/strong\u003e in immunological research. Measurement of anticardiolipin antibody IgG is used in research settings to characterise the class-switched, affinity-matured humoral response to anionic phospholipid antigens, study immunoglobulin class distribution within antiphospholipid antibody families, and investigate autoantibody profiles in immunological research models.\u003c\/p\u003e\n\u003cp\u003eThe kit employs a \u003cstrong\u003esolid-phase ELISA principle\u003c\/strong\u003e with cardiolipin antigen immobilized on the solid phase and enzyme-conjugated anti-human IgG detection antibodies in the liquid phase. Results are evaluated against a \u003cstrong\u003ecut-off value\u003c\/strong\u003e established from the assay calibrators and are expressed in \u003cstrong\u003eGPL units\u003c\/strong\u003e (IgG phospholipid units) referenced to the kit calibrators, yielding a semi-quantitative interpretation. The assay is configured for a \u003cstrong\u003e50 µL sample volume\u003c\/strong\u003e and a \u003cstrong\u003etotal incubation time of approximately 1.5–2.5 hours\u003c\/strong\u003e (depending on protocol configuration), with absorbance read at \u003cstrong\u003e450 nm\u003c\/strong\u003e using standard microplate ELISA equipment. The kit is supplied in a \u003cstrong\u003e96-test\/box\u003c\/strong\u003e format with an \u003cstrong\u003e18-month shelf life\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntended Use:\u003c\/strong\u003e For \u003cstrong\u003elaboratory research use only\u003c\/strong\u003e. This product is \u003cstrong\u003enot intended for use in diagnostic procedures\u003c\/strong\u003e, \u003cstrong\u003enot for therapeutic use\u003c\/strong\u003e, and \u003cstrong\u003enot for clinical decision-making\u003c\/strong\u003e. Results should be interpreted by qualified laboratory professionals in the context of research applications.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003ch3\u003eSolid-Phase ELISA for Anticardiolipin Antibody IgG Detection\u003c\/h3\u003e\n\u003cp\u003eThe assay utilizes a \u003cstrong\u003esolid-phase ELISA format\u003c\/strong\u003e in which cardiolipin antigen is immobilized on the 96-well microplate and enzyme-conjugated anti-human IgG detection antibodies are supplied in liquid phase. This configuration supports specific antibody capture and signal generation, enabling evaluation of IgG-class anticardiolipin reactivity in serum and plasma matrices. Because the detection conjugate is directed against the \u003cstrong\u003egamma heavy chain of human IgG\u003c\/strong\u003e, the readout is restricted to the IgG isotype and does not report total anticardiolipin immunoglobulin content — an important distinction when IgG, IgM, and IgA classes are studied as separate analytes within an antiphospholipid antibody profile. The monomeric, bivalent structure of IgG gives a defined two-site binding stoichiometry per molecule, which supports consistent semi-quantitative classification against calibrators in solid-phase formats. The anionic phospholipid coating requires careful blocking and stabilisation to preserve antigen accessibility across the shelf life of the plate.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSolid-phase ELISA format\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEstablished principle for anticardiolipin antibody detection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eAnti-human IgG detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIgG-isotype specific readout, not total immunoglobulin\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eAnionic phospholipid antigen coating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePreserves cardiolipin antigen accessibility\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eGPL unit reporting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIsotype-appropriate unit convention for IgG anticardiolipin\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance Aligned with Published Anticardiolipin Antibody ELISA Benchmarks\u003c\/h3\u003e\n\u003cp\u003ePublished performance data for ELISA-format anticardiolipin antibody assays report \u003cstrong\u003ecut-off value based semi-quantitative evaluation\u003c\/strong\u003e, with results expressed in \u003cstrong\u003eisotype-specific phospholipid units\u003c\/strong\u003e — GPL units for the IgG class — referenced to kit calibrators rather than to a mass-concentration standard. It is well documented in the literature that \u003cstrong\u003eantiphospholipid antibody assays lack a common international calibrator\u003c\/strong\u003e, so absolute unit values obtained on different platforms are not directly interchangeable and cut-off definitions differ between referenced configurations; laboratory professionals should confirm the applicable calibrator and cut-off definitions against the kit documentation supplied with each lot. Precision data for antibody-class ELISA formats of this type generally indicate \u003cstrong\u003eintra-assay CV values below 10%\u003c\/strong\u003e and \u003cstrong\u003einter-assay CV values below 15%\u003c\/strong\u003e. Sample volumes of \u003cstrong\u003e50 µL\u003c\/strong\u003e are used in this configuration, and absorbance is read at \u003cstrong\u003e450 nm\u003c\/strong\u003e. These reference benchmarks support dependable performance expectations for research-oriented anticardiolipin antibody IgG serology.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCut-off value based semi-quantitative readout (published benchmark)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStandardised qualitative and semi-quantitative framework\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eGPL unit reporting (published benchmark)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIsotype-specific unit convention for IgG anticardiolipin\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIntra-assay CV \u0026lt;10%; inter-assay CV \u0026lt;15% (published benchmark)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRepeatability and reproducibility suitable for laboratory use\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eStandardized 96-Well Workflow with 50 µL Sample Volume\u003c\/h3\u003e\n\u003cp\u003eThe assay is formatted for standard 96-well microplate processing with a \u003cstrong\u003e50 µL sample volume\u003c\/strong\u003e and a \u003cstrong\u003etotal incubation time of approximately 1.5–2.5 hours\u003c\/strong\u003e. Absorbance is measured at \u003cstrong\u003e450 nm\u003c\/strong\u003e, aligning with widely available ELISA readers and washers.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e96 tests\/box\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePractical batch configuration for research workflows\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e50 µL sample volume\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStandard ELISA sample requirement\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e450 nm reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCompatible with common microplate spectrophotometers\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e~1.5–2.5 hour total incubation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEfficient turnaround for batch processing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e18-Month Shelf Life\u003c\/h3\u003e\n\u003cp\u003eExtended reagent stability supports inventory planning and reduces replacement frequency in laboratory settings.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e18-month shelf life\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eExtended inventory stability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eConsistent batch supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupports repeatable research workflows\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Contents \u0026amp; Pricing (EXW US Dollar)\u003c\/h2\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProduct Description\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePackage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eShelf Life\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePrice\/Kit (USD)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCPT (USD\/Test)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eACA Anticardiolipin Antibody IgG ELISA Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e96 Tests\/Box\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e18 Months\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$38.00\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$0.3958\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eCost per test:\u003c\/strong\u003e approximately \u003cstrong\u003e$0.40\u003c\/strong\u003e, based on a 96-test kit configuration.\u003c\/p\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSpecification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDetail\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eModel \/ SKU\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGHM ACA Anticardiolipin Antibody IgG ELISA Kit US\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEnzyme-Linked Immunosorbent Assay (ELISA) Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIntended Use\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSemi-quantitative determination of anticardiolipin antibody IgG in human serum or plasma; \u003cstrong\u003efor laboratory research use only; not for use in diagnostic procedures; not for therapeutic use\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAssay Principle\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSolid-phase ELISA with anti-human IgG detection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTarget Analyte\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAnticardiolipin antibody, immunoglobulin G (IgG) class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunoglobulin Class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIgG (gamma heavy chain specific; monomeric, bivalent)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAntigen\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCardiolipin (diphosphatidylglycerol), anionic phospholipid\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCofactor Consideration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eβ2-glycoprotein I dependent binding in solid-phase formats\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSpecimen Types\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHuman serum, plasma\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSpecimen Volume\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e50 µL\/well\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePackage Size\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e96 Tests\/Box\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShelf Life\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e18 Months\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eReading Wavelength\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e450 nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTotal Incubation Time\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eApproximately 1.5–2.5 hours (protocol-dependent)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePrecision (published benchmark)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIntra-assay CV \u0026lt;10%; inter-assay CV \u0026lt;15%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResult Interpretation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCut-off value based semi-quantitative readout (published benchmark)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCalibration Format\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGPL units (IgG phospholipid units) referenced to kit calibrators; no common international calibrator\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRegulatory Status\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eManufactured under EN ISO 13485 certified quality management system\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhy Laboratories Choose Global Healthcare Medical\u003c\/h2\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConsideration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGHM ACA Anticardiolipin Antibody IgG ELISA Kit US\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSolid-phase ELISA with anti-human IgG detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIgG-isotype specific readout, not total immunoglobulin\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eGPL unit convention\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIsotype-appropriate reporting for IgG anticardiolipin\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIsotype-specific panel capability\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePairs with the IgM and IgA configurations for class comparison\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance aligned with published anticardiolipin ELISA benchmarks\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCut-off value based; CV \u0026lt;10%\/\u0026lt;15%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCost-effective research serology\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$0.3958 per test; $38.00 per 96-test kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e18-month shelf life\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eExtended inventory stability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eStandard 96-well format\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCompatible with routine ELISA equipment\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eISO 13485 certified\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eQuality management system compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAbout Global Healthcare Medical\u003c\/h2\u003e\n\u003cp\u003eGlobal Healthcare Medical connects clinical laboratories, research institutions, and blood screening centers with diagnostic reagents and analytical systems designed for reliable operation in demanding healthcare environments. The GHM ACA Anticardiolipin Antibody IgG ELISA Kit US is part of our professional ELISA reagent portfolio, developed to support standardized, reproducible laboratory workflows.\u003c\/p\u003e\n\u003cp\u003eOur focus is on dependable analytical performance, clear documentation, and responsive support for professional laboratory operations.\u003c\/p\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46768325001260,"sku":null,"price":38.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/ACAAnticardiolipinAntibodyIgGELISATestKit.png?v=1795533192","url":"https:\/\/www.globalhealthcaremedical.com\/products\/ghm-aca-anticardiolipin-antibody-igg-elisa-kit-us-96-well-solid-phase-elisa-for-semi-quantitative-determination-of-anticardiolipin-antibody-igg-in-serum-plasma-96t-kit","provider":"Global Healthcare Medical","version":"1.0","type":"link"}