{"product_id":"ghm-ca-5500-us-compact-automated-coagulation-analyzer-with-200-t-h-throughput-hil-interference-warning-10-1-inch-touchscreen","title":"GHM CA 5500 US – Compact Automated Coagulation Analyzer with 200 T\/H Throughput, HIL Interference Warning \u0026 10.1-Inch Touchscreen","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSKU:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e GHM CA 5500 US\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBrand:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e Global Healthcare Medical\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGlobal Healthcare Medical GHM CA 5500 US\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is a compact, fully automated coagulation analyzer engineered for hemostasis testing in hospital laboratories, emergency departments, clinics, and health check-up centers\u003c\/span\u003e\u003cspan class=\"\"\u003e. The system delivers a throughput of up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e200 tests per hour\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e20 sample positions\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e20 reagent positions\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, providing a balanced combination of high-quality results and rapid turnaround for routine and STAT coagulation testing\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"1\"\u003e\u003ca href=\"https:\/\/www.getein.com\/coagulation_c7\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.getein.com\/ca-5500-automated-coagulation-analyzer_p185.html\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe analyzer utilizes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etransmitted light detection for clot analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, alongside \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003echromogenic and immunoturbidimetric methods\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for specialized coagulation assays\u003c\/span\u003e\u003cspan class=\"\"\u003e. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efully automated HIL (Hemolysis, Icterus, Lipemia) sample solution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esuperior resistance to sample interference\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, supporting reliable results even in challenging specimens\u003c\/span\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAutomatic barcode recognition\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic dilution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic retesting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ereagent probe heating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e further streamline the testing workflow\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"3\"\u003e\u003ca href=\"https:\/\/www.getein.com\/ca-5500-automated-coagulation-analyzer_p185.html\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/vip.stock.finance.sina.com.cn\/corp\/view\/vCB_AllBulletinDetail.php?stockid=603387\u0026amp;id=10457180#4\" rel=\"noreferrer\" aria-label=\"5\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe system features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efolding 10.1-inch high-definition touch screen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAndroid-based operating system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, designed to align with familiar user operation habits\u003c\/span\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esample incubation module\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ereagent refrigeration system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (reagent cabin maintained at \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e14.0°C ± 1.0°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e) support exceptional accuracy of results, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eincubation area, reagent probe, and testing area\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e are all maintained at \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e37.0°C ± 1.0°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"6\"\u003e\u003ca href=\"https:\/\/www.getein.com\/ca-5500-automated-coagulation-analyzer_p185.html\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/money.finance.sina.com.cn\/corp\/view\/vCB_AllBulletinDetail.php?stockid=603387\u0026amp;id=11075281#4\" rel=\"noreferrer\" aria-label=\"4\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSTAT function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e prioritizes emergency samples for immediate processing, and the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etilted aspirating design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e reduces dead space volume of reagents for more cost-effective operation\u003c\/span\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eenclosed sample testing design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic cabin door opening and locking\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports biosafety during analysis\u003c\/span\u003e\u003cspan class=\"\"\u003e. With dimensions of \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e518 × 495 × 545 mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and a weight of \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e40 kg\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, the GHM CA 5500 US integrates into space-constrained laboratory environments while delivering automated coagulation testing capability.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"10\"\u003e\u003ca href=\"https:\/\/www.getein.com\/ca-5500-automated-coagulation-analyzer_p185.html\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/money.finance.sina.com.cn\/corp\/view\/vCB_AllBulletinDetail.php?stockid=603387\u0026amp;id=11075281#4\" rel=\"noreferrer\" aria-label=\"4\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eHIL Interference Warning – Superior Resistance to Sample Interference\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe analyzer incorporates a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efully automated HIL sample solution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e that provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esuperior resistance to sample interference\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e from hemolysis, icterus, and lipemia. This feature supports reliable coagulation results even in challenging clinical specimens where sample quality may be variable\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"12\"\u003e\u003ca href=\"https:\/\/www.getein.com\/ca-5500-automated-coagulation-analyzer_p185.html\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eBenefit\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHIL interference warning\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eFlags sample quality issues before result reporting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSuperior interference resistance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eReliable results in challenging specimens\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAutomated sample monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSupports confidence in reported coagulation values\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003ePrecise Temperature Control – Incubation and Reagent Refrigeration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe system maintains \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esample incubation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ereagent refrigeration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e at precisely controlled temperatures: the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ereagent cabin\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is held at \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e14.0°C ± 1.0°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eincubation area\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ereagent probe\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etesting area\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e are all maintained at \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e37.0°C ± 1.0°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. This multi-zone temperature control supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eexceptional accuracy of results\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e across the coagulation testing workflow.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"13\"\u003e\u003ca href=\"https:\/\/www.getein.com\/ca-5500-automated-coagulation-analyzer_p185.html\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eBenefit\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eReagent cabin at 14.0°C ± 1.0°C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePreserves reagent stability on board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIncubation area at 37.0°C ± 1.0°C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eOptimal reaction temperature control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eReagent probe \u0026amp; testing area at 37.0°C ± 1.0°C\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eConsistent thermal conditions throughout the assay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSTAT Function – Emergency Sample Priority\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSTAT function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e prioritizes emergency samples, ensuring they are \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eprocessed immediately\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e without waiting behind routine batches\u003c\/span\u003e\u003cspan class=\"\"\u003e. This capability is critical in emergency departments and acute care settings where rapid coagulation results inform time-sensitive clinical decisions.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"15\"\u003e\u003ca href=\"https:\/\/www.getein.com\/ca-5500-automated-coagulation-analyzer_p185.html\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eBenefit\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSTAT priority processing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eEmergency samples tested immediately\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNo workflow interruption\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eRoutine runs continue while STAT samples are prioritized\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eTilted Aspirating Design – Reduced Reagent Dead Volume\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etilted aspirating design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e reduces the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edead space volume of reagents\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, supporting more efficient reagent utilization and lower cost per test\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"16\"\u003e\u003ca href=\"https:\/\/www.getein.com\/ca-5500-automated-coagulation-analyzer_p185.html\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eBenefit\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTilted reagent aspiration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eReduced dead volume and optimized reagent consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCost-effective operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLower reagent waste per test\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eAutomated Workflow – Barcode Recognition, Auto-Dilution \u0026amp; Auto-Retest\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe analyzer features \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic barcode recognition\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic dilution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic retesting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for streamlined operation\u003c\/span\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eenclosed sample testing design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic cabin door opening and locking\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports biosafety during analysis\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"17\"\u003e\u003ca href=\"https:\/\/money.finance.sina.com.cn\/corp\/view\/vCB_AllBulletinDetail.php?stockid=603387\u0026amp;id=11075281#4\" rel=\"noreferrer\" aria-label=\"4\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/vip.stock.finance.sina.com.cn\/corp\/view\/vCB_AllBulletinDetail.php?stockid=603387\u0026amp;id=10457180#4\" rel=\"noreferrer\" aria-label=\"5\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eBenefit\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAutomatic barcode recognition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eError-free sample identification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAutomatic dilution \u0026amp; retesting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eReduced manual intervention\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEnclosed sample testing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eBiosafe workflow with automatic cabin door lock\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e10.1-Inch Android Touchscreen – Intuitive Operation with Folding Screen\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe system features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efolding 10.1-inch high-definition touch screen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAndroid-based operating system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, designed to align with familiar user operation habits\u003c\/span\u003e\u003cspan class=\"\"\u003e. The folding screen design reduces the instrument's footprint when not in use.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"19\"\u003e\u003ca href=\"https:\/\/www.getein.com\/ca-5500-automated-coagulation-analyzer_p185.html\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/money.finance.sina.com.cn\/corp\/view\/vCB_AllBulletinDetail.php?stockid=603387\u0026amp;id=11075281#4\" rel=\"noreferrer\" aria-label=\"4\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eBenefit\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e10.1-inch HD touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eClear display for result review and workflow navigation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAndroid OS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eFamiliar and responsive user experience\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFolding screen design\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eReduced footprint and flexible placement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eComprehensive Coagulation Test Menu – PT, APTT, FIB, TT, AT III, FDP, D-Dimer\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe GHM CA 5500 US supports a comprehensive coagulation test menu covering \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eroutine and specialized hemostasis assays\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, including \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePT, APTT, FIB, TT, AT III, FDP, and D-Dimer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, alongside associated consumables and quality control materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eClinical Category\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eKey Assays\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRoutine Coagulation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePT, APTT, TT, FIB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eThrombosis \u0026amp; Fibrinolysis\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eD-Dimer, FDP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAnticoagulation Monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAT III\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eReagent, Consumable \u0026amp; Quality Control Pricing (EXW US Dollar)\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eCoagulation Reagents\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eAll coagulation reagents are supplied in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e400 Tests\/Box\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-bar\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eTesting Item\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003ePacking\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eEXW Price (USD\/test)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eEXW Price (USD\/box)\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePT\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e8 × 5 mL\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e400 Tests\/Box\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$0.195\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$75.00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eTT\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e8 × 5 mL\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e400 Tests\/Box\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$0.15\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$60.00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAPTT\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAPTT Reagent (R1): 4 × 5 mL; CaCl₂ (R2): 4 × 5 mL\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e400 Tests\/Box\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$0.12\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$45.00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eFIB\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eFIB Thrombin Reagent (R2): 4 × 5 mL; FIB Sample Diluent: 3 × 20 mL; FIB Calibration (Freeze-dried powder): 1 × 1 mL\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e400 Tests\/Box\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$0.225\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$90.00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAT III\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eReagent 1 (R1): 8 × 4 mL; Reagent 2 (R2): 8 × 4 mL; Heparin Dilution Solution: 6 × 20 mL; Calibration (Freeze-dried powder): 1 × 1 mL\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e400 Tests\/Box\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$1.125\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$450.00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eFDP\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eFDP Reagent 1 (R1): 8 × 4 mL; FDP Reagent 2 (R2): 8 × 4 mL; FDP Calibration (Freeze-dried powder): 1 × 1 mL\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e400 Tests\/Box\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$1.125\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$450.00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eD-Dimer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eDD Reagent 1 (R1): 8 × 4 mL; DD Reagent 2 (R2): 8 × 4 mL; DD Calibration (Freeze-dried powder): 1 × 1 mL\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e400 Tests\/Box\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$1.50\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$600.00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eConsumables\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eProduct\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eEXW Price (USD\/Barrel or Box)\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eCoagulation Cleaning Solution 1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e3 L \/ Barrel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$45.00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eCoagulation Cleaning Solution 2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e5 L \/ Barrel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$300.00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eCoagulation Reaction Cup\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e140 cups per pack, 5 packs\/box\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$45.00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eCoagulation Cleaning Solution Base 1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e50 mL \/ Box\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$12.00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eCoagulation Cleaning Solution Acid 2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e50 mL \/ Box\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$12.00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eQuality Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eProduct\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eEXW Price (USD\/Tube)\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eNormal Value for D-dimer QC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1 × 1 mL\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$15.00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAbnormal Value for D-dimer QC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1 × 1 mL\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$15.00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eNormal Value for FDP QC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1 × 1 mL\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$15.00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAbnormal Value for FDP QC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1 × 1 mL\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$15.00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eNormal Value for 5-item (PT, TT, APTT, AT III, FIB) Composite QC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1 × 1 mL\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$30.00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAbnormal Value for 5-item (PT, TT, APTT, AT III, FIB) Composite QC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1 × 1 mL\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e$30.00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eModel \/ SKU\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eGHM CA 5500 US\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eFully Automated Coagulation Analyzer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eIntended Use\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cem\u003e\u003cspan class=\"\"\u003eIn vitro\u003c\/span\u003e\u003c\/em\u003e\u003cspan class=\"\"\u003e quantitative detection of coagulation parameters in human plasma for professional laboratory use\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eMethodology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eClot (transmitted light detection), chromogenic, and immunoturbidimetric principles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eThroughput\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e200 T\/H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSample Positions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eReagent Positions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eStorage Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e100,000 reaction curves\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e10.1-inch high-definition touch screen, folding design\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eOperating System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAndroid-based\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eReagent Cabin Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e14.0°C ± 1.0°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eIncubation Area Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e37.0°C ± 1.0°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eReagent Probe Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e37.0°C ± 1.0°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eTesting Area Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e37.0°C ± 1.0°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eHIL Interference\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAutomated HIL sample solution with warning\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSTAT Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eYes, priority processing for emergency samples\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAutomated Features\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eBarcode recognition, auto-dilution, auto-retesting, reagent probe heating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eBiosafety Design\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eEnclosed sample testing with automatic cabin door opening and locking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e518 mm (L) × 495 mm (W) × 545 mm (H)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e40 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eApplicable Settings\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eMedical laboratories, hospital labs, emergency departments, clinics, health check-up centers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eRegulatory Status\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eManufactured under EN ISO 13485 certified quality management system\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Laboratories and Emergency Departments Choose Global Healthcare Medical\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eConsideration\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eGHM CA 5500 US\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCompact footprint\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e518 × 495 × 545 mm, 40 kg, suitable for space-constrained settings\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHigh throughput\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e200 T\/H for routine and STAT coagulation testing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHIL interference warning\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSuperior resistance to hemolysis, icterus, and lipemia interference\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePrecise temperature control\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eMulti-zone temperature management for reagent and reaction stability\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSTAT priority\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eEmergency samples processed immediately\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eComprehensive menu\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePT, APTT, FIB, TT, AT III, FDP, and D-Dimer available\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAndroid touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e10.1-inch folding HD display with familiar operation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eISO 13485 certified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eQuality management system compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eAbout Global Healthcare Medical\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eGlobal Healthcare Medical connects clinical laboratories, hospital departments, and emergency care settings with high-performance diagnostic systems designed for reliable operation in demanding healthcare environments. The GHM CA 5500 US is part of our professional coagulation analyzer line, developed to support accurate, compact, and rapid hemostasis testing in medical laboratories, emergency departments, clinics, and health check-up centers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eOur focus is on dependable analytical performance, clear documentation, and responsive support for professional clinical operations.\u003c\/span\u003e\u003c\/p\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46704281583660,"sku":null,"price":9999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/CA5500AutomatedCoagulationAnalyzer.png?v=1794911317","url":"https:\/\/www.globalhealthcaremedical.com\/products\/ghm-ca-5500-us-compact-automated-coagulation-analyzer-with-200-t-h-throughput-hil-interference-warning-10-1-inch-touchscreen","provider":"Global Healthcare Medical","version":"1.0","type":"link"}