{"product_id":"ghm-ct-chlamydia-trachomatis-antibody-igg-elisa-kit-us-96-well-solid-phase-elisa-for-semi-quantitative-determination-of-anti-c-trachomatis-igg-in-serum-plasma-96t-kit","title":"GHM Ct Chlamydia Trachomatis Antibody IgG ELISA Kit US – 96-Well Solid-Phase ELISA for Semi-Quantitative Determination of Anti-C. trachomatis IgG in Serum \u0026 Plasma (96T\/Kit)","description":"\u003cp\u003e\u003cstrong\u003eSKU: \u003c\/strong\u003eGHM Ct Chlamydia Trachomatis Antibody IgG ELISA Test Kit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBrand: \u003c\/span\u003e\u003c\/strong\u003eGlobal Healthcare Medical\u003c\/p\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Healthcare Medical GHM Ct Chlamydia Trachomatis Antibody IgG ELISA Kit US\u003c\/strong\u003e is a 96-well enzyme-linked immunosorbent assay (ELISA) designed for the \u003cstrong\u003esemi-quantitative determination of immunoglobulin G (IgG)-class antibodies directed against \u003cem\u003eChlamydia trachomatis\u003c\/em\u003e antigens\u003c\/strong\u003e in human serum and plasma specimens. \u003cem\u003eC. trachomatis\u003c\/em\u003e is an \u003cstrong\u003eobligate intracellular Gram-negative bacterium\u003c\/strong\u003e with a distinctive \u003cstrong\u003ebiphasic developmental cycle\u003c\/strong\u003e that alternates between two morphologically and functionally distinct forms. The \u003cstrong\u003eelementary body (EB)\u003c\/strong\u003e is the compact, metabolically quiescent, environmentally stable form, whose outer membrane is extensively \u003cstrong\u003ecross-linked by cysteine-rich proteins\u003c\/strong\u003e and which serves as the dispersal vehicle; the \u003cstrong\u003ereticulate body (RB)\u003c\/strong\u003e is the larger, metabolically active, replicative form found within the intracellular compartment. The \u003cstrong\u003emajor outer membrane protein (MOMP, encoded by \u003cem\u003eompA\u003c\/em\u003e)\u003c\/strong\u003e is the \u003cstrong\u003edominant surface antigen\u003c\/strong\u003e and the principal target of antibody recognition, its surface-exposed loops carrying both serovar-specific and species-specific determinants. The outer envelope also contains the \u003cstrong\u003ecysteine-rich proteins OmcA and OmcB\u003c\/strong\u003e, a \u003cstrong\u003elipopolysaccharide bearing a genus-specific epitope\u003c\/strong\u003e, and the \u003cstrong\u003epolymorphic membrane protein (Pmp)\u003c\/strong\u003e family. \u003cem\u003eC. trachomatis\u003c\/em\u003e is studied within the broader field of \u003cstrong\u003echlamydial cell biology and serological characterisation of obligate intracellular bacteria\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe IgG class is the \u003cstrong\u003emost abundant immunoglobulin isotype in serum\u003c\/strong\u003e, accounting for approximately three quarters of total serum immunoglobulin, and it is the product of \u003cstrong\u003eclass switching and avidity maturation\u003c\/strong\u003e following antigen encounter. IgG circulates as a \u003cstrong\u003emonomeric, bivalent molecule\u003c\/strong\u003e with two antigen-binding sites per molecule, and its \u003cstrong\u003eFcRn-mediated recycling\u003c\/strong\u003e pathway gives it the longest circulatory half-life among the immunoglobulin classes. For an \u003cstrong\u003eobligate intracellular organism\u003c\/strong\u003e, the systemic IgG response is the compartment in which antibody reactivity is most reproducibly measured, because circulating immunoglobulin integrates reactivity generated across compartmental and systemic sites rather than sampling a single local compartment. Measurement of anti-\u003cem\u003eC. trachomatis\u003c\/em\u003e antibody IgG is used in research settings to characterise systemic humoral reactivity to chlamydial surface antigens, study immunoglobulin class distribution across antibacterial antibody responses, and investigate MOMP antigen–antibody interaction profiles in microbiological research models.\u003c\/p\u003e\n\u003cp\u003eThe kit employs a \u003cstrong\u003esolid-phase ELISA principle\u003c\/strong\u003e with \u003cem\u003eC. trachomatis\u003c\/em\u003e antigen immobilized on the solid phase and enzyme-conjugated anti-human IgG detection antibodies in the liquid phase. Results are evaluated against a \u003cstrong\u003ecut-off value\u003c\/strong\u003e established from the assay calibrators, yielding a semi-quantitative interpretation expressed as a cut-off index. The assay is configured for a \u003cstrong\u003e50 µL sample volume\u003c\/strong\u003e and a \u003cstrong\u003etotal incubation time of approximately 1.5–2.5 hours\u003c\/strong\u003e (depending on protocol configuration), with absorbance read at \u003cstrong\u003e450 nm\u003c\/strong\u003e using standard microplate ELISA equipment. The kit is supplied in a \u003cstrong\u003e96-test\/box\u003c\/strong\u003e format with an \u003cstrong\u003e18-month shelf life\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntended Use:\u003c\/strong\u003e For \u003cstrong\u003elaboratory research use only\u003c\/strong\u003e. This product is \u003cstrong\u003enot intended for use in diagnostic procedures\u003c\/strong\u003e, \u003cstrong\u003enot for therapeutic use\u003c\/strong\u003e, and \u003cstrong\u003enot for clinical decision-making\u003c\/strong\u003e. Results should be interpreted by qualified laboratory professionals in the context of research applications.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003ch3\u003eSolid-Phase ELISA for Anti-C. trachomatis Antibody IgG Detection\u003c\/h3\u003e\n\u003cp\u003eThe assay utilizes a \u003cstrong\u003esolid-phase ELISA format\u003c\/strong\u003e in which \u003cem\u003eC. trachomatis\u003c\/em\u003e antigen is coated onto the 96-well microplate and enzyme-conjugated anti-human IgG detection antibodies are supplied in liquid phase. This configuration supports specific antibody capture and signal generation, enabling evaluation of IgG-class antichlamydial reactivity in serum and plasma matrices. Because the detection conjugate is directed against the \u003cstrong\u003egamma heavy chain of human IgG\u003c\/strong\u003e, the readout is restricted to the IgG isotype and does not report total antichlamydial immunoglobulin content — an important distinction when IgG and IgM classes are studied as separate analytes in a paired serological design.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSolid-phase ELISA format\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEstablished principle for antichlamydial IgG detection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eAnti-human IgG detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIgG-isotype specific readout, not total immunoglobulin\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eWhole-organism antigen coating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePresents native MOMP and envelope epitopes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCut-off index evaluation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStandardised semi-quantitative interpretation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eElementary Body Antigen Preserving MOMP Surface Loops\u003c\/h3\u003e\n\u003cp\u003eAntibody recognition of \u003cem\u003eC. trachomatis\u003c\/em\u003e is dominated by \u003cstrong\u003eMOMP\u003c\/strong\u003e, whose surface-exposed loops carry the determinants that distinguish serovars, and those determinants are \u003cstrong\u003econformational\u003c\/strong\u003e: they depend on the disulfide-cross-linked folding of the protein within the outer envelope rather than on linear sequence alone. The \u003cstrong\u003eelementary body\u003c\/strong\u003e is the form whose envelope is most extensively cross-linked and therefore \u003cstrong\u003estructurally most stable\u003c\/strong\u003e, which makes an EB-derived whole-organism preparation the appropriate antigen source for preserving \u003cstrong\u003enative MOMP loop conformation\u003c\/strong\u003e together with the cysteine-rich Omc proteins and the genus-specific lipopolysaccharide epitope. This design rationale distinguishes the format from configurations built on denatured or isolated recombinant MOMP fragments, where loop-dependent epitopes are lost. Because the antigen set spans several envelope components, the readout reflects \u003cstrong\u003ecomposite antichlamydial reactivity\u003c\/strong\u003e rather than a single-protein response.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eElementary body whole-organism antigen\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePreserves native, cross-linked envelope structure\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eNative MOMP loop conformation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRetains serovar- and species-specific determinants\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMultiple envelope antigens present\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eComposite rather than single-protein readout\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDistinct from recombinant MOMP formats\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eComplements single-antigen configurations\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSystemic IgG as the Reproducible Compartment for an Intracellular Organism\u003c\/h3\u003e\n\u003cp\u003eBecause \u003cem\u003eC. trachomatis\u003c\/em\u003e is \u003cstrong\u003eobligate intracellular\u003c\/strong\u003e, the organism is not accessible to antibody in the extracellular space during its replicative phase, and local antibody sampling is correspondingly variable. Circulating \u003cstrong\u003eIgG integrates reactivity generated across compartmental and systemic sites\u003c\/strong\u003e, which is why serum IgG is the compartment in which antichlamydial antibody reactivity is most reproducibly measured and most extensively reported in the literature. Following class switching, \u003cstrong\u003esomatic hypermutation and avidity maturation\u003c\/strong\u003e raise the intrinsic affinity of the IgG pool, so IgG-class antichlamydial reactivity reflects a \u003cstrong\u003emature rather than early-phase humoral response\u003c\/strong\u003e. IgG is consequently the isotype with the largest body of comparable published data in chlamydial serology, and IgG results are commonly used as the \u003cstrong\u003ereference axis\u003c\/strong\u003e when IgM data are interpreted alongside them.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSystemic IgG compartment\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMost reproducible measurand for an intracellular organism\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eAffinity-matured IgG pool\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eReflects a mature rather than early-phase response\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eLargest published dataset\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMost directly comparable to literature values\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePaired design with the IgM configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupports class comparison in the same format\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance Aligned with Published Antichlamydial IgG ELISA Benchmarks\u003c\/h3\u003e\n\u003cp\u003ePublished performance data for ELISA-format antichlamydial IgG assays are \u003cstrong\u003eplatform-dependent\u003c\/strong\u003e, and \u003cstrong\u003eunit definitions vary between referenced configurations\u003c\/strong\u003e. Available product data for whole-organism bacterial antigen ELISA formats report \u003cstrong\u003esample volumes of 50–100 µL\u003c\/strong\u003e, a \u003cstrong\u003ecolorimetric microplate readout at 450 nm\u003c\/strong\u003e, and \u003cstrong\u003etime to results of approximately 1–5 hours\u003c\/strong\u003e, with results expressed as a \u003cstrong\u003ecut-off index\u003c\/strong\u003e derived from kit calibrators rather than a mass-concentration standard. Precision data for antibody-class ELISA formats of this type generally indicate \u003cstrong\u003eintra-assay CV values below 10%\u003c\/strong\u003e and \u003cstrong\u003einter-assay CV values below 15%\u003c\/strong\u003e. Sample volumes of \u003cstrong\u003e50 µL\u003c\/strong\u003e are used in this configuration, and absorbance is read at \u003cstrong\u003e450 nm\u003c\/strong\u003e. Laboratory professionals should confirm the applicable calibrator and cut-off definitions against the kit documentation supplied with each lot, and should exercise independent judgment in interpreting cut-off index values in a research context.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCut-off index based semi-quantitative readout (published benchmark)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStandardised qualitative and semi-quantitative framework\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIntra-assay CV \u0026lt;10%; inter-assay CV \u0026lt;15% (published benchmark)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRepeatability and reproducibility suitable for laboratory use\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eArbitrary unit reporting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eConsistent with established antichlamydial ELISA practice\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eStandardized 96-Well Workflow with 50 µL Sample Volume\u003c\/h3\u003e\n\u003cp\u003eThe assay is formatted for standard 96-well microplate processing with a \u003cstrong\u003e50 µL sample volume\u003c\/strong\u003e and a \u003cstrong\u003etotal incubation time of approximately 1.5–2.5 hours\u003c\/strong\u003e. Absorbance is measured at \u003cstrong\u003e450 nm\u003c\/strong\u003e, aligning with widely available ELISA readers and washers.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e96 tests\/box\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePractical batch configuration for research workflows\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e50 µL sample volume\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStandard ELISA sample requirement\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e450 nm reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCompatible with common microplate spectrophotometers\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e~1.5–2.5 hour total incubation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEfficient turnaround for batch processing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e18-Month Shelf Life\u003c\/h3\u003e\n\u003cp\u003eExtended reagent stability supports inventory planning and reduces replacement frequency in laboratory settings.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e18-month shelf life\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eExtended inventory stability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eConsistent batch supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupports repeatable research workflows\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Contents \u0026amp; Pricing (EXW US Dollar)\u003c\/h2\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProduct Description\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePackage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eShelf Life\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePrice\/Kit (USD)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCPT (USD\/Test)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCt Chlamydia Trachomatis Antibody IgG ELISA Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e96 Tests\/Box\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e18 Months\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$38.00\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$0.3958\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eCost per test:\u003c\/strong\u003e approximately \u003cstrong\u003e$0.40\u003c\/strong\u003e, based on a 96-test kit configuration.\u003c\/p\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSpecification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDetail\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eModel \/ SKU\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGHM Ct Chlamydia Trachomatis Antibody IgG ELISA Kit US\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEnzyme-Linked Immunosorbent Assay (ELISA) Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIntended Use\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSemi-quantitative determination of anti-\u003cem\u003eC. trachomatis\u003c\/em\u003e antibody IgG in human serum or plasma; \u003cstrong\u003efor laboratory research use only; not for use in diagnostic procedures; not for therapeutic use\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAssay Principle\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSolid-phase ELISA with anti-human IgG detection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTarget Analyte\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAnti-\u003cem\u003eChlamydia trachomatis\u003c\/em\u003e antibody, immunoglobulin G (IgG) class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunoglobulin Class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIgG (gamma heavy chain specific; monomeric, bivalent)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAntigen\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eC. trachomatis\u003c\/em\u003e antigen (elementary body whole-organism preparation; MOMP and envelope epitopes)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSpecimen Types\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHuman serum, plasma\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSpecimen Volume\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e50 µL\/well\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePackage Size\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e96 Tests\/Box\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShelf Life\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e18 Months\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eReading Wavelength\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e450 nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTotal Incubation Time\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eApproximately 1.5–2.5 hours (protocol-dependent)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePrecision (published benchmark)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIntra-assay CV \u0026lt;10%; inter-assay CV \u0026lt;15%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResult Interpretation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCut-off index based semi-quantitative readout (published benchmark)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCalibration Format\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCut-off index referenced to kit calibrators (not mass-concentration calibrated)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRegulatory Status\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eManufactured under EN ISO 13485 certified quality management system\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhy Laboratories Choose Global Healthcare Medical\u003c\/h2\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConsideration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGHM Ct Chlamydia Trachomatis Antibody IgG ELISA Kit US\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSolid-phase ELISA with anti-human IgG detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIgG-isotype specific readout, not total immunoglobulin\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eElementary body whole-organism antigen\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePreserves native, cross-linked envelope structure\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eNative MOMP loop conformation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRetains serovar- and species-specific determinants\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSystemic IgG compartment\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMost reproducible measurand for an intracellular organism\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance aligned with published antichlamydial IgG ELISA benchmarks\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCut-off index based; CV \u0026lt;10%\/\u0026lt;15%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCost-effective research serology\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$0.3958 per test; $38.00 per 96-test kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e18-month shelf life\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eExtended inventory stability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eStandard 96-well format\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCompatible with routine ELISA equipment\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eISO 13485 certified\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eQuality management system compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAbout Global Healthcare Medical\u003c\/h2\u003e\n\u003cp\u003eGlobal Healthcare Medical connects clinical laboratories, research institutions, and blood screening centers with diagnostic reagents and analytical systems designed for reliable operation in demanding healthcare environments. The GHM Ct Chlamydia Trachomatis Antibody IgG ELISA Kit US is part of our professional ELISA reagent portfolio, developed to support standardized, reproducible laboratory workflows.\u003c\/p\u003e\n\u003cp\u003eOur focus is on dependable analytical performance, clear documentation, and responsive support for professional laboratory operations.\u003c\/p\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46773876588588,"sku":null,"price":38.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/CtChlamydiaTrachomatisAntibodyIgGELISATestKit.png?v=1795614254","url":"https:\/\/www.globalhealthcaremedical.com\/products\/ghm-ct-chlamydia-trachomatis-antibody-igg-elisa-kit-us-96-well-solid-phase-elisa-for-semi-quantitative-determination-of-anti-c-trachomatis-igg-in-serum-plasma-96t-kit","provider":"Global Healthcare Medical","version":"1.0","type":"link"}