{"product_id":"ghm-h900-semi-auto-h-electrolyte-analyzer","title":"GHM H900 Semi-auto H Electrolyte Analyzer #","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLithium, Ionized Calcium \u0026amp; pH – All in One Advanced Analyzer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe GHM H900 Semi-auto H combines therapeutic lithium monitoring with complete calcium and acid‑base parameters. It measures\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epotassium (K⁺)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esodium (Na⁺)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003echloride (Cl⁻)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eionized calcium (iCa⁺⁺)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003enormalized calcium (nCa)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etotal calcium (TCa)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epH\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elithium (Li⁺)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Ideal for psychiatric units, critical care, nephrology, and labs managing bipolar patients with complex metabolic needs.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e7\" Color Touch Screen\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eIntuitive human‑machine interface with real‑time sample ID display and dynamic menu navigation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFull Parameter Set – Model H Configuration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003ePotassium (K⁺)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eSodium (Na⁺)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eChloride (Cl⁻)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eIonized Calcium (iCa⁺⁺)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eNormalized Calcium (nCa) – pH‑adjusted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eTotal Calcium (TCa)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003epH\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLithium (Li⁺)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– for therapeutic drug monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHigh Precision Across All Analytes\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eIon‑selective electrode (ISE) technology. Measuring speed ≤30 seconds.\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"\"\u003ePrecision (CV%):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eK, Na, Cl ≤1.5%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eiCa, pH ≤2.0%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eLi⁺ ≤3.0%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWide Measuring Ranges\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eLi⁺: 0.10–6.00 mmol\/L (therapeutic \u0026amp; toxic levels)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eiCa: 0.10–6.00 mmol\/L\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003epH: 4.00–9.00\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSmart Fluid Management\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eAutomatic liquid level detection and alarm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eDetects and filters tiny bubbles – prevents clogs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eWave theory flushing + direct flush pipe method – eliminates cross‑contamination\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAutomatic Calibration \u0026amp; QC Tools\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eTwo‑point correction adjusts slope and intercept. Print QC graphs and statistical parameters for lithium, calcium, and pH.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLarge Data Storage\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eStores up to 10,000 test results with power failure protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eConnectivity \u0026amp; Integration\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eRS‑232 port, optional barcode reader, LIS software compatible. Selectable upload data format. RTC clock management.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEnergy‑Saving Sleep Mode\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eReduces reagent consumption. Can be powered off anytime – ideal for mixed workloads.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eReal‑Time System Diagnostics\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eContinuously monitors working status. Supports fuzzy query and system alerts.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOptional Sample Tray\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eAutomate sample handling when needed.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSpecifications (Model H)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eMeasuring Range\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eResolution\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003ePrecision (CV%)\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eK⁺\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.50–20.00 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.01 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤1.5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eNa⁺\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e15.0–200.0 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.1 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤1.5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eCl⁻\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e15.0–200.0 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.1 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤1.5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eCa⁺⁺ (iCa)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.10–6.00 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.01 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤2.0%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003epH\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e4.00–9.00\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.01 pH\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤2.0%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLi⁺\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.10–6.00 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.01 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤3.0%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSample positions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e38 (5 emergency + 3 functional)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePrinter:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eInternal thermal printer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWorking environment:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e5–40°C, ≤80% RH\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAC220V±22V, ≤120W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e625 × 280 × 384 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNet weight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e6 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWhy choose Model H?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eOne instrument – lithium monitoring for bipolar therapy, plus ionized calcium and pH for critical care. Perfect for hospitals and labs that need both psychopharmacology support and metabolic\/acid‑base assessment. No need for separate analyzers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":45557208252460,"sku":null,"price":1899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/GHMH900Semi-autoHElectrolyteAnalyzer.png?v=1779289321","url":"https:\/\/www.globalhealthcaremedical.com\/products\/ghm-h900-semi-auto-h-electrolyte-analyzer","provider":"GlobalHeathcareMedical","version":"1.0","type":"link"}