{"product_id":"ghm-hev-hepatitis-e-virus-antibody-igm-elisa-kit-us-96-well-solid-phase-elisa-for-semi-quantitative-determination-of-anti-hev-igm-in-serum-plasma-96t-kit","title":"GHM HEV Hepatitis E Virus Antibody IgM ELISA Kit US – 96-Well Solid-Phase ELISA for Semi-Quantitative Determination of Anti-HEV IgM in Serum \u0026 Plasma (96T\/Kit)","description":"\u003cp\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e GHM HEV Hepatitis E Virus Antibody IgM ELISA Kit US\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Global Healthcare Medical\u003c\/p\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Healthcare Medical GHM HEV Hepatitis E Virus Antibody IgM ELISA Kit US\u003c\/strong\u003e is a 96-well enzyme-linked immunosorbent assay (ELISA) designed for the \u003cstrong\u003esemi-quantitative determination of immunoglobulin M (IgM)-class antibodies directed against hepatitis E virus (HEV) antigens\u003c\/strong\u003e in human serum and plasma specimens. HEV is a small \u003cstrong\u003epositive-sense, single-stranded RNA virus\u003c\/strong\u003e classified in the family \u003cem\u003eHepeviridae\u003c\/em\u003e, with a genome of approximately 7.2 kb organised into \u003cstrong\u003ethree open reading frames\u003c\/strong\u003e. ORF1 encodes the non-structural polyprotein carrying the methyltransferase, helicase, and RNA-dependent RNA polymerase domains; \u003cstrong\u003eORF2 encodes the capsid protein\u003c\/strong\u003e, which assembles into a \u003cstrong\u003eT=1 icosahedral shell built from 60 copies of a single subunit\u003c\/strong\u003e; and ORF3 encodes a small phosphoprotein associated with virion morphogenesis and release. The HEV capsid is therefore \u003cstrong\u003estructurally more homogeneous than that of viruses whose shells are assembled from several distinct subunit types\u003c\/strong\u003e, and the ORF2 protein is \u003cstrong\u003eN-glycosylated\u003c\/strong\u003e at defined sequons. HEV is also notable for occurring in both a \u003cstrong\u003enon-enveloped form\u003c\/strong\u003e and a \u003cstrong\u003equasi-enveloped form\u003c\/strong\u003e in which the capsid is transiently wrapped in a host-derived lipid membrane — a feature that influences how the particle surface is presented to antibodies. HEV is studied within the broader field of \u003cstrong\u003ehepeviral molecular biology and serological characterisation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe IgM class is the \u003cstrong\u003efirst immunoglobulin isotype to appear in a primary humoral response to a viral antigen\u003c\/strong\u003e, before class switching to IgG or IgA, and it circulates predominantly as a \u003cstrong\u003epentamer\u003c\/strong\u003e in which five monomeric units are linked by disulfide bonds and a joining (J) chain, giving ten antigen-binding sites per molecule. Because of its high molecular mass, IgM is largely \u003cstrong\u003econfined to the intravascular compartment\u003c\/strong\u003e and does not readily transude into secretory fluids — a distribution property that determines the specimen types appropriate to IgM-class serology. Measurement of anti-HEV antibody IgM is used in research settings to characterise early-phase humoral reactivity to hepeviral capsid antigens, study immunoglobulin class distribution across antiviral antibody responses, and investigate viral antigen–antibody interaction profiles in virological research models.\u003c\/p\u003e\n\u003cp\u003eThe kit employs a \u003cstrong\u003esolid-phase ELISA principle\u003c\/strong\u003e with HEV antigen immobilized on the solid phase and enzyme-conjugated anti-human IgM detection antibodies in the liquid phase. Results are evaluated against a \u003cstrong\u003ecut-off value\u003c\/strong\u003e established from the assay calibrators, yielding a semi-quantitative interpretation expressed as a cut-off index. The assay is configured for a \u003cstrong\u003e50 µL sample volume\u003c\/strong\u003e and a \u003cstrong\u003etotal incubation time of approximately 1.5–2.5 hours\u003c\/strong\u003e (depending on protocol configuration), with absorbance read at \u003cstrong\u003e450 nm\u003c\/strong\u003e using standard microplate ELISA equipment. The kit is supplied in a \u003cstrong\u003e96-test\/box\u003c\/strong\u003e format with an \u003cstrong\u003e18-month shelf life\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntended Use:\u003c\/strong\u003e For \u003cstrong\u003elaboratory research use only\u003c\/strong\u003e. This product is \u003cstrong\u003enot intended for use in diagnostic procedures\u003c\/strong\u003e, \u003cstrong\u003enot for therapeutic use\u003c\/strong\u003e, and \u003cstrong\u003enot for clinical decision-making\u003c\/strong\u003e. Results should be interpreted by qualified laboratory professionals in the context of research applications.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003ch3\u003eSolid-Phase ELISA for Anti-HEV Antibody IgM Detection\u003c\/h3\u003e\n\u003cp\u003eThe assay utilizes a \u003cstrong\u003esolid-phase ELISA format\u003c\/strong\u003e in which HEV antigen is coated onto the 96-well microplate and enzyme-conjugated anti-human IgM detection antibodies are supplied in liquid phase. This configuration supports specific antibody capture and signal generation, enabling evaluation of IgM-class antiviral reactivity in serum and plasma matrices. Because the detection conjugate is directed against the \u003cstrong\u003emu heavy chain of human IgM\u003c\/strong\u003e, the readout is restricted to the IgM isotype and does not report total antiviral immunoglobulin content — an important distinction when IgM and IgG classes are studied as separate analytes in a paired serological design.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSolid-phase ELISA format\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEstablished principle for antiviral IgM detection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eAnti-human IgM detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIgM-isotype specific readout, not total immunoglobulin\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eViral antigen coating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePresents native capsid conformational epitopes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCut-off index evaluation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStandardised semi-quantitative interpretation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHomogeneous Single-Subunit Capsid Antigen\u003c\/h3\u003e\n\u003cp\u003eThe HEV capsid is assembled from \u003cstrong\u003e60 copies of one protein species — the ORF2 gene product\u003c\/strong\u003e — rather than from a mixture of distinct subunit types, which makes the virion surface an \u003cstrong\u003eimmunologically homogeneous and highly ordered array\u003c\/strong\u003e. This single-subunit architecture concentrates the neutralising epitopes into a \u003cstrong\u003erepetitive, structurally uniform display\u003c\/strong\u003e, and because the ORF2 protein is \u003cstrong\u003eN-glycosylated\u003c\/strong\u003e, a proportion of the recognised epitopes depends on glycan occupancy in addition to polypeptide fold. Coating with a whole-virus antigen preparation preserves these \u003cstrong\u003econformational and glycosylation-dependent capsid epitopes\u003c\/strong\u003e, in contrast to formats that present denatured or isolated recombinant fragments. The distinction matters in practice: the HEV capsid is a single-protein shell, so antigen preparation choices have a proportionally larger effect on the epitope repertoire than they would for a multi-subunit capsid.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eWhole-virus capsid antigen coating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePreserves conformational quaternary epitopes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSingle-subunit 60-copy shell\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStructurally uniform, repetitive epitope display\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eNative N-glycosylation retained\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupports glycan-dependent epitope recognition\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDistinct from recombinant-fragment formats\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eComplements single-antigen ELISA configurations\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePentameric IgM Binding to a Repetitive Capsid Epitope Array\u003c\/h3\u003e\n\u003cp\u003eRepetitive epitope display is precisely the geometry in which \u003cstrong\u003eIgM's pentameric architecture\u003c\/strong\u003e confers its advantage: with ten antigen-binding sites per molecule, IgM engages multiple capsid epitopes simultaneously, generating \u003cstrong\u003ehigh functional avidity\u003c\/strong\u003e through multivalent attachment even where the intrinsic affinity of an individual site is modest. Because the HEV shell is built from a single subunit species, the epitopes presented across the particle surface are \u003cstrong\u003emore uniform in structure than those of a multi-subunit capsid\u003c\/strong\u003e, which favours consistent multivalent engagement. This structure–function relationship is specific to IgM and does not apply equivalently to the monomeric IgG configuration, which makes the IgM isotype a distinct analytical window on anti-HEV reactivity rather than a simple replicate of the IgG response.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePentameric IgM with ten binding sites\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHigh functional avidity on repetitive capsid arrays\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eUniform single-subunit epitope set\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eConsistent multivalent engagement across particles\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eEarly-phase isotype positioning\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCaptures the first antiviral antibody class to appear\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePaired isotype design\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupports IgM and IgG comparison in the same format\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance Aligned with Published Antiviral IgM ELISA Benchmarks\u003c\/h3\u003e\n\u003cp\u003ePublished performance data for ELISA-format antiviral IgM assays report \u003cstrong\u003esample volumes of 50–100 µL\u003c\/strong\u003e, a \u003cstrong\u003ecolorimetric microplate readout at 450 nm\u003c\/strong\u003e, and \u003cstrong\u003etime to results of approximately 1–5 hours\u003c\/strong\u003e, with results expressed as a \u003cstrong\u003ecut-off index\u003c\/strong\u003e derived from kit calibrators rather than a mass-concentration standard. Precision data for antibody-class ELISA formats of this type generally indicate \u003cstrong\u003eintra-assay CV values below 10%\u003c\/strong\u003e and \u003cstrong\u003einter-assay CV values below 15%\u003c\/strong\u003e. Sample volumes of \u003cstrong\u003e50 µL\u003c\/strong\u003e are used in this configuration, and absorbance is read at \u003cstrong\u003e450 nm\u003c\/strong\u003e. Because the same assay format is commonly applied to paired IgM and IgG determinations, laboratory professionals should confirm the applicable calibrator and cut-off definitions against the kit documentation supplied with each lot, and should exercise independent judgment in interpreting cut-off index values in a research context.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCut-off index based semi-quantitative readout (published benchmark)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStandardised qualitative and semi-quantitative framework\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIntra-assay CV \u0026lt;10%; inter-assay CV \u0026lt;15% (published benchmark)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRepeatability and reproducibility suitable for laboratory use\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eArbitrary unit reporting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eConsistent with established antiviral ELISA practice\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eStandardized 96-Well Workflow with 50 µL Sample Volume\u003c\/h3\u003e\n\u003cp\u003eThe assay is formatted for standard 96-well microplate processing with a \u003cstrong\u003e50 µL sample volume\u003c\/strong\u003e and a \u003cstrong\u003etotal incubation time of approximately 1.5–2.5 hours\u003c\/strong\u003e. Absorbance is measured at \u003cstrong\u003e450 nm\u003c\/strong\u003e, aligning with widely available ELISA readers and washers.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e96 tests\/box\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePractical batch configuration for research workflows\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e50 µL sample volume\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStandard ELISA sample requirement\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e450 nm reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCompatible with common microplate spectrophotometers\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e~1.5–2.5 hour total incubation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEfficient turnaround for batch processing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e18-Month Shelf Life\u003c\/h3\u003e\n\u003cp\u003eExtended reagent stability supports inventory planning and reduces replacement frequency in laboratory settings.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e18-month shelf life\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eExtended inventory stability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eConsistent batch supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupports repeatable research workflows\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Contents \u0026amp; Pricing (EXW US Dollar)\u003c\/h2\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProduct Description\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePackage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eShelf Life\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePrice\/Kit (USD)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCPT (USD\/Test)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHEV Hepatitis E Virus Antibody IgM ELISA Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e96 Tests\/Box\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e18 Months\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$28.00\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$0.2917\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eCost per test:\u003c\/strong\u003e approximately \u003cstrong\u003e$0.29\u003c\/strong\u003e, based on a 96-test kit configuration.\u003c\/p\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSpecification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDetail\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eModel \/ SKU\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGHM HEV Hepatitis E Virus Antibody IgM ELISA Kit US\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEnzyme-Linked Immunosorbent Assay (ELISA) Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIntended Use\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSemi-quantitative determination of anti-HEV antibody IgM in human serum or plasma; \u003cstrong\u003efor laboratory research use only; not for use in diagnostic procedures; not for therapeutic use\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAssay Principle\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSolid-phase ELISA with anti-human IgM detection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTarget Analyte\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAnti-hepatitis E virus antibody, immunoglobulin M (IgM) class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunoglobulin Class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIgM (mu heavy chain specific; pentameric)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAntigen\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHEV antigen (whole-virus preparation; ORF2 capsid protein epitopes)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSpecimen Types\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHuman serum, plasma\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSpecimen Volume\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e50 µL\/well\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePackage Size\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e96 Tests\/Box\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShelf Life\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e18 Months\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eReading Wavelength\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e450 nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTotal Incubation Time\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eApproximately 1.5–2.5 hours (protocol-dependent)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePrecision (published benchmark)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIntra-assay CV \u0026lt;10%; inter-assay CV \u0026lt;15%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResult Interpretation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCut-off index based semi-quantitative readout (published benchmark)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCalibration Format\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCut-off index referenced to kit calibrators (not mass-concentration calibrated)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRegulatory Status\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eManufactured under EN ISO 13485 certified quality management system\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhy Laboratories Choose Global Healthcare Medical\u003c\/h2\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConsideration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGHM HEV Hepatitis E Virus Antibody IgM ELISA Kit US\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSolid-phase ELISA with anti-human IgM detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIgM-isotype specific readout, not total immunoglobulin\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eWhole-virus capsid antigen coating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePreserves conformational quaternary epitopes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSingle-subunit 60-copy shell\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStructurally uniform, repetitive epitope display\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePentameric IgM on a repetitive capsid array\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTen binding sites per molecule; high functional avidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance aligned with published antiviral IgM ELISA benchmarks\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCut-off index based; CV \u0026lt;10%\/\u0026lt;15%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCost-effective research serology\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$0.2917 per test; $28.00 per 96-test kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e18-month shelf life\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eExtended inventory stability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eStandard 96-well format\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCompatible with routine ELISA equipment\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eISO 13485 certified\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eQuality management system compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAbout Global Healthcare Medical\u003c\/h2\u003e\n\u003cp\u003eGlobal Healthcare Medical connects clinical laboratories, research institutions, and blood screening centers with diagnostic reagents and analytical systems designed for reliable operation in demanding healthcare environments. The GHM HEV Hepatitis E Virus Antibody IgM ELISA Kit US is part of our professional ELISA reagent portfolio, developed to support standardized, reproducible laboratory workflows.\u003c\/p\u003e\n\u003cp\u003eOur focus is on dependable analytical performance, clear documentation, and responsive support for professional laboratory operations.\u003c\/p\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46773825798188,"sku":null,"price":29.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/HEVHepatitisEVirusAntibodyIgMELISATestKit.png?v=1795612351","url":"https:\/\/www.globalhealthcaremedical.com\/products\/ghm-hev-hepatitis-e-virus-antibody-igm-elisa-kit-us-96-well-solid-phase-elisa-for-semi-quantitative-determination-of-anti-hev-igm-in-serum-plasma-96t-kit","provider":"Global Healthcare Medical","version":"1.0","type":"link"}