{"product_id":"ghm-m-900-semi-auto-k-electrolyte-analyzer","title":"GHM M-900 Semi-auto K Electrolyte Analyzer #","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMagnesium, Ionized Calcium \u0026amp; pH – Essential for Cardiac \u0026amp; Neuromuscular Care\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe GHM M-900 Semi-auto K is designed for serum, plasma, whole blood, and dilute urine samples. It measures\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epotassium (K⁺)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esodium (Na⁺)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003echloride (Cl⁻)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eionized calcium (iCa⁺⁺)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003enormalized calcium (nCa)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etotal calcium (TCa)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epH\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emagnesium (Mg⁺⁺)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. This makes it the perfect choice for cardiology, neurology, ICUs, and metabolic labs where magnesium monitoring is critical for heart rhythm, muscle function, and neurological stability.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e7\" Color Touch Screen\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eIntuitive human‑machine interface – easy to operate with minimal training.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLow Cost of Use – Fast Return on Investment\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eConsumables cost a fraction of imported alternatives. Most users recover their investment quickly – ideal for budget‑conscious facilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eComprehensive Parameter Set – Model K Configuration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003ePotassium (K⁺): 0.50–20.00 mmol\/L\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eSodium (Na⁺): 15.0–200.0 mmol\/L\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eChloride (Cl⁻): 15.0–200.0 mmol\/L\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIonized Calcium (iCa⁺⁺)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e: 0.10–6.00 mmol\/L – bioactive calcium for cardiac and nerve function\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNormalized Calcium (nCa)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– pH‑adjusted for accurate assessment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTotal Calcium (TCa)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epH\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e: 4.00–9.00 – acid‑base balance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMagnesium (Mg⁺⁺)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e: 0.10–4.00 mmol\/L – vital for cardiac conduction, muscle contraction, and enzyme function\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHigh Precision Across All Analytes\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eIon‑selective electrode (ISE) technology. Measuring time ≤40 seconds.\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"\"\u003ePrecision (CV%):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eK, Na, Cl, Ca⁺⁺ ≤1.5%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003epH ≤2.0%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eMg⁺⁺ ≤3.5% (per M-900 specifications)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCompact \u0026amp; Lightweight\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003e334 × 252 × 365 mm, only 5 kg – saves bench space and reduces shipping costs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAutomatic Flushing After Each Sample\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eKeeps electrodes clean and extends their life – reduces maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLarge Data Storage\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eStores up to 10,000 test results with power failure protection – no data loss.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBlockage Prevention \u0026amp; Cross‑Contamination Control\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eOriginal wave flushing + direct injection tube design minimizes clogs and cross‑pollution for accurate results.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eError Warnings \u0026amp; Auto Troubleshooting\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eAlerts you to issues and guides problem‑solving – improves workflow efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eConnectivity Ready\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eRS‑232 port for LIS connection. Print QC graphs and statistical parameters for hospital management.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSleep Mode\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eReduces reagent consumption when idle – saves money and extends consumable life.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSpecifications (Model K)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eMeasuring Range\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eResolution\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003ePrecision (CV%)\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eK⁺\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.50–20.00 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.01 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤1.5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eNa⁺\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e15.0–200.0 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.1 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤1.5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eCl⁻\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e15.0–200.0 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.1 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤1.5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eCa⁺⁺ (iCa)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.10–6.00 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.01 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤1.5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003epH\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e4.00–9.00\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.01 pH\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤2.0%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eMg⁺⁺\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.10–4.00 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e0.01 mmol\/L\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e≤3.5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSample types:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSerum, plasma, whole blood, dilute urine\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAnalysis method:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIon‑selective electrode (ISE)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMeasuring time:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e≤40 seconds\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePrinter:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eInternal thermal printer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eStorage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUp to 10,000 results\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWorking environment:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e5–40°C, 30–85% RH\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower supply:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAC 100‑240V, 50\/60Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e334 × 252 × 365 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNet weight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e5 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWhy choose Model K?\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eMagnesium is often overlooked but critical for cardiac arrhythmias, pre‑eclampsia, and neuromuscular disorders. The M-900 Semi-auto K delivers accurate magnesium alongside ionized calcium and pH – all in one compact, affordable analyzer. Ideal for cardiology wards, ICUs, and metabolic clinics.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":45557258485804,"sku":null,"price":1688.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/GHMM-900Semi-autoKElectrolyteAnalyzer.png?v=1779291459","url":"https:\/\/www.globalhealthcaremedical.com\/products\/ghm-m-900-semi-auto-k-electrolyte-analyzer","provider":"GlobalHeathcareMedical","version":"1.0","type":"link"}