{"product_id":"ghm-mdk-310-us-fully-auto-glycated-hemoglobin-hba1c-analyzer-10-position-ion-exchange-hplc-system-with-75-second-fast-mode-continuous-sample-loading-and-dual-ifcc-ngsp-reporting","title":"GHM MDK-310 US Fully Auto Glycated Hemoglobin (HbA1c) Analyzer – 10-Position Ion-Exchange HPLC System with 75-Second Fast Mode, Continuous Sample Loading and Dual IFCC\/NGSP Reporting","description":"\u003cp\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e GHM MDK-310 US\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Global Healthcare Medical\u003c\/p\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Healthcare Medical GHM MDK-310 US\u003c\/strong\u003e is a \u003cstrong\u003efully automated benchtop analyzer for the separation and quantification of glycated hemoglobin (HbA1c) and hemoglobin fractions by high-performance ion-exchange liquid chromatography (HPLC)\u003c\/strong\u003e, built around a \u003cstrong\u003e75-second analytical cycle\u003c\/strong\u003e and a \u003cstrong\u003econtinuously fed 10-position sample disk\u003c\/strong\u003e. It is the throughput-oriented configuration of the GHM HPLC platform: the same ion-exchange chemistry and the same three-buffer reagent set, with a \u003cstrong\u003eshorter cycle time and automatic continuous rack loading\u003c\/strong\u003e that keep the instrument working through a queue of samples rather than waiting for a batch to be assembled by hand.\u003c\/p\u003e\n\u003cp\u003eThe instrument performs the complete analytical sequence without operator intervention between loading and result output: \u003cstrong\u003ethe sample is identified by barcode, the primary tube cap is pierced automatically, 5 µL of whole blood is aspirated, haemolysed in-line at a 5 µL : 1,500 µL ratio, injected onto a cation-exchange column, eluted under a programmed gradient and detected at 415 nm\u003c\/strong\u003e — the absorbance maximum of the haem group. Results print on the integrated thermal printer, are written to on-board storage, and can be routed to a laboratory information system over USB.\u003c\/p\u003e\n\u003cp\u003eSeparation is \u003cstrong\u003echarge-based cation exchange\u003c\/strong\u003e, not an antibody or enzymatic reaction. Hemoglobin species differ in net surface charge according to globin composition and post-translational modification; HbA1c carries additional negative charge at the N-terminal valine of the β-chain through irreversible glucose adduction and therefore elutes at a \u003cstrong\u003ereproducible position relative to the unmodified HbA0 peak\u003c\/strong\u003e. The instrument integrates peak area across defined elution windows and reports \u003cstrong\u003epercentage composition\u003c\/strong\u003e for each fraction. Because the result is a \u003cstrong\u003epeak-area ratio taken directly from the chromatogram\u003c\/strong\u003e, it does not depend on reagent-lot immunoreactivity, and it is traceable to column separation performance and pump flow stability.\u003c\/p\u003e\n\u003cp\u003eThree modes are selectable in software from the \u003cstrong\u003esame installed reagent set\u003c\/strong\u003e, with no reagent change, column change or re-plumbing. \u003cstrong\u003eFast mode returns a HbA1c result in 75 seconds — 48 samples per hour\u003c\/strong\u003e; \u003cstrong\u003eVariant mode (100 seconds)\u003c\/strong\u003e opens the integration window to report HbA1a, HbA1b, labile A1c (LA1c), stable A1c, HbF, HbA2 and the variant fractions HbS, HbD, HbE and HbJ; \u003cstrong\u003eA2\/F mode (240 seconds)\u003c\/strong\u003e extends the run to resolve the A2 and F regions for \u003cstrong\u003eHbA2 and HbF quantification\u003c\/strong\u003e. All results are reported in \u003cstrong\u003eboth IFCC (mmol\/mol) and NGSP (%) units\u003c\/strong\u003e from a single injection.\u003c\/p\u003e\n\u003cp\u003eConsumables are the \u003cstrong\u003e4,000-test chromatographic column\u003c\/strong\u003e, the \u003cstrong\u003e500-test in-line pre-sieve\u003c\/strong\u003e (nine supplied with the instrument) and buffer packs in \u003cstrong\u003e100, 200, 500, 1,000 and 2,000-test\u003c\/strong\u003e sizes, with every pack price listed in the pricing section below.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntended Use:\u003c\/strong\u003e For \u003cstrong\u003eprofessional laboratory use\u003c\/strong\u003e. The instrument is intended for operation by qualified laboratory personnel within a controlled laboratory environment. It is \u003cstrong\u003enot intended for self-testing, home use, or operation by untrained personnel\u003c\/strong\u003e. Results should be interpreted by qualified laboratory professionals in accordance with the laboratory's own validated procedures and applicable local regulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e The analyzer is supplied as a \u003cstrong\u003emain unit without the chromatographic column\u003c\/strong\u003e; the column is ordered separately as a consumable (see pricing).\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003ch3\u003e75-Second Cycle, 48 Samples per Hour\u003c\/h3\u003e\n\u003cp\u003eThe 75-second Fast cycle is a \u003cstrong\u003ecomplete analytical cycle\u003c\/strong\u003e, not a partial one: aspiration, in-line haemolysis, injection, gradient separation, 415 nm detection, peak integration, printing and data storage all occur inside it. At that cycle time the instrument delivers \u003cstrong\u003e48 HbA1c results per hour\u003c\/strong\u003e, which changes how a 10-position disk behaves in practice — a full disk is consumed in roughly twelve and a half minutes, so the disk is a \u003cstrong\u003eflow buffer rather than a batch container\u003c\/strong\u003e. For a laboratory running morning peaks, the difference between a 90-second and a 75-second cycle is the difference between 40 and 48 results per hour, or \u003cstrong\u003eroughly 60 additional results across a seven-hour working day\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e75-second complete cycle\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAspiration to printed result inside one cycle\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e48 samples per hour\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHigher morning-peak capacity than a 90-second cycle\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eFull disk consumed in ~12.5 minutes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDisk functions as a flow buffer, not a batch\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e~60 extra results per 7-hour day\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMeasurable capacity gain at unchanged staffing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eContinuous Automatic Sample Loading\u003c\/h3\u003e\n\u003cp\u003eLoading is \u003cstrong\u003econtinuous and automatic\u003c\/strong\u003e: as positions on the 10-place disk free up, further primary tubes or sample cups can be added and the instrument picks them up without a run being restarted or a batch being completed. Combined with a \u003cstrong\u003e75-second cycle\u003c\/strong\u003e, this removes the idle time that appears whenever a manual batch finishes before the next batch is assembled — the analyzer is fed sample by sample rather than batch by batch. The disk accepts \u003cstrong\u003eprimary blood tubes and sample cups interchangeably in the same run\u003c\/strong\u003e, so a laboratory can mix tube types without reconfiguring anything.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eContinuous automatic loading\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSamples added while the run continues\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eNo batch assembly wait\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eInstrument does not idle between batches\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e10-position disk\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSteady queue at a 75-second cycle\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eTubes and cups in the same run\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMixed collection formats without reconfiguration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eThree Modes at 75 \/ 100 \/ 240 Seconds\u003c\/h3\u003e\n\u003cp\u003eFast, Variant and A2\/F are \u003cstrong\u003esoftware states of one hardware and reagent configuration\u003c\/strong\u003e. \u003cstrong\u003eFast (75 s)\u003c\/strong\u003e covers routine HbA1c; \u003cstrong\u003eVariant (100 s)\u003c\/strong\u003e adds the extended fraction set including HbA1a, HbA1b, LA1c, stable A1c, HbF and the variant windows HbS, HbD, HbE and HbJ; \u003cstrong\u003eA2\/F (240 s)\u003c\/strong\u003e resolves the A2 and F regions for HbA2 and HbF quantification. Because all three run on the \u003cstrong\u003esame buffers and the same column\u003c\/strong\u003e, a laboratory can move from routine throughput to extended profiling for an individual sample \u003cstrong\u003ewithout interrupting reagent supply, swapping a column or recalibrating\u003c\/strong\u003e. The 240-second A2\/F cycle is also short enough that extended profiling does not have to be deferred to a separate shift.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eFast 75 s \/ Variant 100 s \/ A2\/F 240 s\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne platform, three cycle budgets\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSame buffers and column in all modes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNo swap, no re-plumbing, no recalibration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eVariant windows S, D, E, J\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUnexpected peaks visible rather than suppressed\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e240 s A2\/F cycle\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eExtended profiling fits inside the working day\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWide Measuring Range and Full Fraction Panel\u003c\/h3\u003e\n\u003cp\u003eThe calibrated measuring range is \u003cstrong\u003eHbA1c 3–25% (9–250 mmol\/mol)\u003c\/strong\u003e, \u003cstrong\u003eHbF 0.45–45%\u003c\/strong\u003e and \u003cstrong\u003eHbA2 0–15%\u003c\/strong\u003e. The 25% upper HbA1c boundary sits well above the 18–20% ceiling common on compact HPLC systems, so samples at the extreme high end of the distribution stay \u003cstrong\u003einside the calibration envelope\u003c\/strong\u003e instead of being flagged above-range and diluted by hand. Each run reports the full fraction set — HbA1a, HbA1b, LA1c, stable A1c, HbF, HbA2 and the variant fractions — so one injection yields both a quantitative HbA1c value and a chromatogram that can be reviewed for unexpected peaks.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eHbA1c 3–25%\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eWider upper boundary than typical compact systems\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eHbF 0.45–45% \/ HbA2 0–15%\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eExtended coverage of the F and A2 regions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eFull fraction panel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eQuantitative result plus qualitative review in one run\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eVariant windows reported\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAtypical peaks are documented, not hidden\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCV ≤ 2% with Dual IFCC \/ NGSP Reporting\u003c\/h3\u003e\n\u003cp\u003eRepeatability is specified at \u003cstrong\u003eCV ≤ 2%\u003c\/strong\u003e, and every result is reported in \u003cstrong\u003eboth IFCC (mmol\/mol) and NGSP (%) units\u003c\/strong\u003e from the same chromatogram — no conversion sheet, no second run. Dual-unit output matters wherever results are exchanged with collaborators or publications that use a different convention, because one analytical measurement is presented in \u003cstrong\u003eboth reference frames at once\u003c\/strong\u003e. Chromatograms are retained on board (\u003cstrong\u003e50,000 results, or 7,500 results with full curves\u003c\/strong\u003e) and can be exported through the \u003cstrong\u003eindependent PC software\u003c\/strong\u003e for archival reporting, curve review and trend analysis.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCV ≤ 2%\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eConsistent replicate performance across the range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIFCC and NGSP together\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOne run, two reporting conventions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e50,000 stored results\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLong retention without external archiving\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e7,500 results with curves\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eChromatograms kept for retrospective review\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIndependent PC software\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCurve review, report generation, data export\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eLong-Life Consumables and Five Buffer Pack Sizes\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ecolumn is rated for 4,000 tests\u003c\/strong\u003e and the \u003cstrong\u003epre-sieve for 500 tests\u003c\/strong\u003e (nine supplied), so scheduled maintenance follows \u003cstrong\u003etest count rather than the calendar\u003c\/strong\u003e. Buffer packs come in \u003cstrong\u003e100, 200, 500, 1,000 and 2,000-test\u003c\/strong\u003e configurations, letting a laboratory match standing inventory to its real monthly workload instead of committing to one oversized pack. Reagents carry a \u003cstrong\u003etwo-year shelf life\u003c\/strong\u003e and remain usable for \u003cstrong\u003ethree months after opening\u003c\/strong\u003e; an opened column is rated for \u003cstrong\u003e4,000 tests within two years of opening\u003c\/strong\u003e, so a low-volume laboratory can run a column to its rated capacity rather than discard it unused.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e4,000-test column\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eReplacement roughly once per 4,000 results\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eFive buffer pack sizes (100–2,000 tests)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eInventory sized to actual monthly volume\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e500-test pre-sieve, 9 supplied\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFilter changes known in advance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e2-year shelf life \/ 3 months in use\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLess write-off, workable open-pack window\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eColumn rated 4,000 tests over 2 years\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFull utilisation at low test volumes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompact 20 kg Chassis with Standard Laboratory Integration\u003c\/h3\u003e\n\u003cp\u003eThe instrument measures \u003cstrong\u003e310 × 470 × 500 mm and weighs 20 kg\u003c\/strong\u003e, so it takes a \u003cstrong\u003esingle bench position\u003c\/strong\u003e rather than a dedicated workstation — notable for a unit delivering 48 results per hour. It runs from \u003cstrong\u003e110–220 V, 50–60 Hz\u003c\/strong\u003e across a \u003cstrong\u003e5–38 °C, 30–70% RH\u003c\/strong\u003e envelope, connects through \u003cstrong\u003eUSB with LIS\/HIS support\u003c\/strong\u003e, and is operated from a \u003cstrong\u003e10.4-inch TFT colour LCD touch screen\u003c\/strong\u003e with barcode-scanner or touch-keypad input. Reports issue on the \u003cstrong\u003ebuilt-in thermal printer\u003c\/strong\u003e or an \u003cstrong\u003eexternal printer\u003c\/strong\u003e, and report layouts can be customised to the site's own template.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e310 × 470 × 500 mm, 20 kg\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSingle bench position at 48 results\/hour\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e110–220 V, 50–60 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDual-range supply, no site configuration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e5–38 °C \/ 30–70% RH\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTolerant of normal ambient variation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eUSB with LIS\/HIS support\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDirect laboratory information system integration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e10.4-inch colour touch screen\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eChromatogram and fraction table on one screen\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCustomisable report layout\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOutput matched to the site's template\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eSystem Contents \u0026amp; Pricing (EXW, USD)\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAnalyzer configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eItem\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDetail\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMain unit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFully automated HPLC HbA1c analyzer, 10-position continuous-loading disk, \u003cstrong\u003ecolumn not included\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSupplied with unit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePower cord, thermal paper roll, user manual, \u003cstrong\u003e9 × pre-sieve\/filter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eColumn\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eOrdered separately — see consumables below\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAnalyzer pricing is quoted per configuration and destination. Request a quotation for the current EXW price of the main unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReagents, consumables and accessories\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProduct Description\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePack Size\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePrice\/Pack (USD)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eBuffer ABCL Set — Buffer A 750 mL ×1, Buffer B 750 mL ×1, Buffer C 750 mL ×1, Hemolysin 750 mL ×1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 tests\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$105.00\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eBuffer ABCL Set — Buffer A 750 mL ×1, Buffer B 750 mL ×1, Buffer C 750 mL ×1, Hemolysin 750 mL ×1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e200 tests\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$105.00\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eBuffer ABCL Set — Buffer A 750 mL ×2, Buffer B 750 mL ×3, Buffer C 750 mL ×2, Hemolysin 750 mL ×3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e500 tests\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$250.50\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eBuffer ABCL Set — Buffer A 750 mL ×4, Buffer B 750 mL ×6, Buffer C 750 mL ×4, Hemolysin 750 mL ×6\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1,000 tests\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$501.00\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eBuffer ABCL Set — Buffer A 750 mL ×8, Buffer B 750 mL ×12, Buffer C 750 mL ×8, Hemolysin 750 mL ×12\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2,000 tests\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$1,002.00\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eChromatographic Column\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4,000 tests\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$675.00\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eQuality Control Set — low value + high value\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 levels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$12.00\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCalibrator Set — low value + high value\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2 levels\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$12.00\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePre-Sieve \/ Filter (9 supplied with instrument; replace every 500 tests)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEach\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$12.00\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eReagent storage:\u003c\/strong\u003e two-year shelf life from manufacture; three months in use after opening. An opened column is rated for 4,000 tests within two years of opening.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePricing terms:\u003c\/strong\u003e EXW, USD, excluding freight, insurance, duties and local taxes. Prices are per pack as listed.\u003c\/p\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSpecification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDetail\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eModel \/ SKU\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGHM MDK-310 US\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFully automated glycated hemoglobin (HbA1c) analyzer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMethodology\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHigh-performance ion-exchange liquid chromatography (HPLC)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDetection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e415 nm LED photometer, rated emitter life 20,000 hours\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSeparation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCation-exchange column, three-buffer programmed gradient (A \/ B \/ C)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePump\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHigh-stability HPLC pump, constant-flow gradient delivery\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTest Modes \u0026amp; Speed\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFast 75 s\/test; Variant 100 s\/test; A2\/F 240 s\/test\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eThroughput\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e48 samples\/hour in Fast mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMeasuring Range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHbA1c 3–25% (9–250 mmol\/mol); HbF 0.45–45%; HbA2 0–15%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePrecision\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCV ≤ 2%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eReported Parameters\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHbA1c; HbA1a, HbA1b, LA1c, stable A1c, HbF, HbA2; variants HbS, HbD, HbE, HbJ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eReporting Units\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIFCC (mmol\/mol) and NGSP (%) from the same run\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSample Types\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eVenous whole blood, finger-peripheral blood, haemolysed blood\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSample Volume\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5 µL whole blood; haemolysate at 5 µL : 1,500 µL ratio\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSample Capacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10 positions per disk; primary tubes and sample cups, interchangeable\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSample Handling\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBarcode identification, automatic cap piercing, continuous automatic loading, in-line haemolysis\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eColumn Capacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e4,000 tests\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePre-Sieve Capacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e500 tests (9 supplied)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDisplay\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e10.4-inch TFT colour LCD touch screen\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInput\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBuilt-in barcode scanner or touch keypad\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eData Storage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e50,000 results, or 7,500 results with full chromatogram curves\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eData Transfer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUSB; LIS\/HIS support; independent PC software\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePrinter\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIntegrated thermal printer; external printer supported\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWorking Conditions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5–38 °C, 30–70% RH\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower Supply\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e110–220 V, 50–60 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e310 × 470 × 500 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e20 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIntended Use\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eQuantification of glycated hemoglobin and hemoglobin fractions in whole blood; \u003cstrong\u003efor professional laboratory use; not for self-testing or home use\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRegulatory Status\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eManufactured under an EN ISO 13485 certified quality management system; market clearance varies by country\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhy Laboratories Choose Global Healthcare Medical\u003c\/h2\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConsideration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGHM MDK-310 US\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e75-second Fast cycle\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eComplete aspiration-to-print cycle\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e48 samples per hour\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHigher capacity than a 90-second platform\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eContinuous automatic loading\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSamples added while the run continues\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eThree modes, one reagent set\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e75 \/ 100 \/ 240 s without reagent change\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic cap piercing\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePrimary tubes loaded directly, no decapping\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e5 µL whole blood\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLow sample volume, finger-peripheral compatible\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eHbA1c range 3–25%\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eWider upper boundary than typical compact systems\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDual IFCC \/ NGSP reporting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBoth conventions from one chromatogram\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCV ≤ 2%\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eConsistent replicate performance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e4,000-test column\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eInfrequent column replacement\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e20 kg, single bench position\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFull throughput without a dedicated workstation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eLIS\/HIS connectivity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDirect laboratory information system integration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAbout Global Healthcare Medical\u003c\/h2\u003e\n\u003cp\u003eGlobal Healthcare Medical supplies clinical laboratories, reference laboratories, and analytical service facilities with laboratory reagents and benchtop analytical systems engineered for dependable operation in demanding healthcare environments. The GHM MDK-310 US sits within our professional HPLC analyzer portfolio alongside the GHM MDK-300 US, sharing the same reagent set, column and consumable range so that a laboratory can standardise on one consumable inventory across both configurations.\u003c\/p\u003e\n\u003cp\u003eOur focus is on verifiable analytical performance, complete technical documentation, and responsive support for professional laboratory operations.\u003c\/p\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46791087620140,"sku":null,"price":4999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/MDK-310FullyAutoGlycatedHemoglobinAnalyzer_HPLC.png?v=1795763913","url":"https:\/\/www.globalhealthcaremedical.com\/products\/ghm-mdk-310-us-fully-auto-glycated-hemoglobin-hba1c-analyzer-10-position-ion-exchange-hplc-system-with-75-second-fast-mode-continuous-sample-loading-and-dual-ifcc-ngsp-reporting","provider":"Global Healthcare Medical","version":"1.0","type":"link"}