{"product_id":"ghm-tb-mycobacterium-tuberculosis-antibody-igg-elisa-kit-us-96-well-solid-phase-elisa-for-semi-quantitative-determination-of-anti-m-tuberculosis-igg-in-serum-plasma-96t-kit","title":"GHM TB Mycobacterium Tuberculosis Antibody IgG ELISA Kit US – 96-Well Solid-Phase ELISA for Semi-Quantitative Determination of Anti-M. tuberculosis IgG in Serum \u0026 Plasma (96T\/Kit)","description":"\u003cp\u003e\u003cstrong\u003eSKU:\u003c\/strong\u003e GHM TB Mycobacterium Tuberculosis Antibody IgG ELISA Kit US\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Global Healthcare Medical\u003c\/p\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eGlobal Healthcare Medical GHM TB Mycobacterium Tuberculosis Antibody IgG ELISA Kit US\u003c\/strong\u003e is a 96-well enzyme-linked immunosorbent assay (ELISA) designed for the \u003cstrong\u003esemi-quantitative determination of immunoglobulin G (IgG)-class antibodies directed against \u003cem\u003eMycobacterium tuberculosis\u003c\/em\u003e antigens\u003c\/strong\u003e in human serum and plasma specimens. \u003cem\u003eM. tuberculosis\u003c\/em\u003e is a \u003cstrong\u003eslow-growing, acid-fast bacillus\u003c\/strong\u003e whose most distinctive feature is a \u003cstrong\u003elipid-rich, multi-layered cell envelope\u003c\/strong\u003e of unusual composition. This envelope comprises an inner plasma membrane, a \u003cstrong\u003epeptidoglycan–arabinogalactan complex\u003c\/strong\u003e covalently linked to \u003cstrong\u003emycolic acids\u003c\/strong\u003e — very-long-chain α-branched fatty acids that form the characteristic outer bilayer — together with \u003cstrong\u003eglycolipids and lipoglycans\u003c\/strong\u003e including \u003cstrong\u003elipoarabinomannan (LAM)\u003c\/strong\u003e, phosphatidylinositol mannosides, and trehalose dimycolate. The cell surface also presents a defined set of \u003cstrong\u003esecreted and cell-wall-associated protein antigens\u003c\/strong\u003e, among them the \u003cstrong\u003eAntigen 85 complex\u003c\/strong\u003e (mycolyl transferases Ag85A\/B\/C), the \u003cstrong\u003eESAT-6 and CFP-10\u003c\/strong\u003e proteins of the ESX-1 secretion system, and heat-shock proteins such as GroEL2. \u003cem\u003eM. tuberculosis\u003c\/em\u003e is studied within the broader field of \u003cstrong\u003emycobacterial cell envelope biology and serological characterisation of bacterial antigen recognition\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe IgG class is the \u003cstrong\u003emost abundant immunoglobulin isotype in serum\u003c\/strong\u003e, accounting for approximately three quarters of total serum immunoglobulin, and it is the product of \u003cstrong\u003eclass switching and avidity maturation\u003c\/strong\u003e following antigen encounter. IgG circulates as a \u003cstrong\u003emonomeric, bivalent molecule\u003c\/strong\u003e with two antigen-binding sites per molecule, and its \u003cstrong\u003eneonatal Fc receptor–mediated recycling\u003c\/strong\u003e pathway gives it the longest circulatory half-life among the immunoglobulin classes. A key consideration for this antigen system is that \u003cstrong\u003eprotein antigens drive class switching and affinity maturation\u003c\/strong\u003e, whereas repetitive glycan and glycolipid epitopes elicit a largely T-independent response in which IgM predominates — so the IgG readout is particularly informative for the \u003cstrong\u003eprotein component\u003c\/strong\u003e of the mycobacterial antigen repertoire, namely the Antigen 85 complex, ESAT-6\/CFP-10, and the heat-shock proteins. Measurement of anti-\u003cem\u003eM. tuberculosis\u003c\/em\u003e antibody IgG is used in research settings to characterise established humoral reactivity to mycobacterial protein antigens, study immunoglobulin class distribution across antibacterial antibody responses, and investigate protein antigen–antibody interaction profiles in immunological research models.\u003c\/p\u003e\n\u003cp\u003eThe kit employs a \u003cstrong\u003esolid-phase ELISA principle\u003c\/strong\u003e with \u003cem\u003eM. tuberculosis\u003c\/em\u003e antigen immobilized on the solid phase and enzyme-conjugated anti-human IgG detection antibodies in the liquid phase. Results are evaluated against a \u003cstrong\u003ecut-off value\u003c\/strong\u003e established from the assay calibrators, yielding a semi-quantitative interpretation expressed as a cut-off index. The assay is configured for a \u003cstrong\u003e50 µL sample volume\u003c\/strong\u003e and a \u003cstrong\u003etotal incubation time of approximately 1.5–2.5 hours\u003c\/strong\u003e (depending on protocol configuration), with absorbance read at \u003cstrong\u003e450 nm\u003c\/strong\u003e using standard microplate ELISA equipment. The kit is supplied in a \u003cstrong\u003e96-test\/box\u003c\/strong\u003e format with an \u003cstrong\u003e18-month shelf life\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntended Use:\u003c\/strong\u003e For \u003cstrong\u003elaboratory research use only\u003c\/strong\u003e. This product is \u003cstrong\u003enot intended for use in diagnostic procedures\u003c\/strong\u003e, \u003cstrong\u003enot for therapeutic use\u003c\/strong\u003e, and \u003cstrong\u003enot for clinical decision-making\u003c\/strong\u003e. Results should be interpreted by qualified laboratory professionals in the context of research applications.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003ch3\u003eSolid-Phase ELISA for Anti-M. tuberculosis Antibody IgG Detection\u003c\/h3\u003e\n\u003cp\u003eThe assay utilizes a \u003cstrong\u003esolid-phase ELISA format\u003c\/strong\u003e in which \u003cem\u003eM. tuberculosis\u003c\/em\u003e antigen is coated onto the 96-well microplate and enzyme-conjugated anti-human IgG detection antibodies are supplied in liquid phase. This configuration supports specific antibody capture and signal generation, enabling evaluation of IgG-class antibacterial reactivity in serum and plasma matrices. Because the detection conjugate is directed against the \u003cstrong\u003egamma heavy chain of human IgG\u003c\/strong\u003e, the readout is restricted to the IgG isotype and does not report total antimycobacterial immunoglobulin content — an important distinction when IgG and IgM classes are studied as separate analytes in a paired serological design.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSolid-phase ELISA format\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEstablished principle for antibacterial IgG detection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eAnti-human IgG detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIgG-isotype specific readout, not total immunoglobulin\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMycobacterial antigen coating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePresents envelope glycolipid and protein epitopes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCut-off index evaluation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStandardised semi-quantitative interpretation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIgG Readout Targeted at the Protein Antigen Component\u003c\/h3\u003e\n\u003cp\u003eThe mycobacterial antigen repertoire is \u003cstrong\u003enot immunologically uniform\u003c\/strong\u003e. Repetitive glycan and glycolipid structures — lipoarabinomannan, arabinomannan, and mycolic acid–containing glycolipids — behave as \u003cstrong\u003eT-independent type 2 antigens\u003c\/strong\u003e and elicit a largely IgM-dominated response. The \u003cstrong\u003eprotein antigens\u003c\/strong\u003e, by contrast, are processed and presented through the class II pathway and \u003cstrong\u003edrive class switching with affinity maturation\u003c\/strong\u003e, so their corresponding antibodies are found predominantly in the IgG class. This configuration therefore provides an IgG readout that is \u003cstrong\u003eselectively informative for the protein component\u003c\/strong\u003e of the antigen repertoire — the Antigen 85 complex, ESAT-6, CFP-10, and GroEL2 — and complements rather than duplicates an IgM determination performed on the same antigen preparation. Recognising this division is what allows the two isotype configurations to be used as a genuinely paired analytical design.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eProtein-antigen–focused IgG readout\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSelectively informative for Ag85, ESAT-6, CFP-10, GroEL2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eClass-switched, affinity-matured pool\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eReflects a mature rather than early-phase response\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePaired design with the IgM configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eComplementary, non-duplicative isotype information\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eWhole-cell antigen coating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePreserves both glycan and protein epitopes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMonomeric Bivalent Binding with Defined Stoichiometry\u003c\/h3\u003e\n\u003cp\u003eIgG binds through a \u003cstrong\u003edefined two-site stoichiometry\u003c\/strong\u003e per molecule, giving a \u003cstrong\u003equantifiable and highly reproducible\u003c\/strong\u003e interaction with the coated antigen across assay runs — an advantage for comparative work in which signal intensity must track antibody concentration consistently. This contrasts with the multivalent engagement characteristic of the pentameric IgM isotype on repetitive epitope arrays. IgG is the \u003cstrong\u003emost extensively characterised isotype\u003c\/strong\u003e in antibacterial serology and the one with the largest body of comparable published data, which is why IgG results are commonly used as the \u003cstrong\u003ereference axis\u003c\/strong\u003e when IgM data are interpreted alongside them.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMonomeric bivalent IgG\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDefined two-site stoichiometry; highly reproducible capture\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eLongest circulatory half-life\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStable, well-characterised analyte\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eReference-axis positioning\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupports interpretation of paired IgM data\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eNative glycolipid and protein epitopes\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eMulti-component antigen repertoire retained\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance Aligned with Published Antibacterial IgG ELISA Benchmarks\u003c\/h3\u003e\n\u003cp\u003ePublished performance data for ELISA-format antibacterial IgG assays report \u003cstrong\u003esample volumes of 50–100 µL\u003c\/strong\u003e, a \u003cstrong\u003ecolorimetric microplate readout at 450 nm\u003c\/strong\u003e, and \u003cstrong\u003etime to results of approximately 1–5 hours\u003c\/strong\u003e, with results expressed as a \u003cstrong\u003ecut-off index\u003c\/strong\u003e derived from kit calibrators rather than a mass-concentration standard. Precision data for antibody-class ELISA formats of this type generally indicate \u003cstrong\u003eintra-assay CV values below 10%\u003c\/strong\u003e and \u003cstrong\u003einter-assay CV values below 15%\u003c\/strong\u003e. Sample volumes of \u003cstrong\u003e50 µL\u003c\/strong\u003e are used in this configuration, and absorbance is read at \u003cstrong\u003e450 nm\u003c\/strong\u003e. Because the same assay format is commonly applied to paired IgM and IgG determinations, laboratory professionals should confirm the applicable calibrator and cut-off definitions against the kit documentation supplied with each lot, and should exercise independent judgment in interpreting cut-off index values in a research context.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCut-off index based semi-quantitative readout (published benchmark)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStandardised qualitative and semi-quantitative framework\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIntra-assay CV \u0026lt;10%; inter-assay CV \u0026lt;15% (published benchmark)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRepeatability and reproducibility suitable for laboratory use\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eArbitrary unit reporting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eConsistent with established antibacterial ELISA practice\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eStandardized 96-Well Workflow with 50 µL Sample Volume\u003c\/h3\u003e\n\u003cp\u003eThe assay is formatted for standard 96-well microplate processing with a \u003cstrong\u003e50 µL sample volume\u003c\/strong\u003e and a \u003cstrong\u003etotal incubation time of approximately 1.5–2.5 hours\u003c\/strong\u003e. Absorbance is measured at \u003cstrong\u003e450 nm\u003c\/strong\u003e, aligning with widely available ELISA readers and washers.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e96 tests\/box\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePractical batch configuration for research workflows\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e50 µL sample volume\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStandard ELISA sample requirement\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e450 nm reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCompatible with common microplate spectrophotometers\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e~1.5–2.5 hour total incubation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEfficient turnaround for batch processing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e18-Month Shelf Life\u003c\/h3\u003e\n\u003cp\u003eExtended reagent stability supports inventory planning and reduces replacement frequency in laboratory settings.\u003c\/p\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eFeature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBenefit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e18-month shelf life\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eExtended inventory stability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eConsistent batch supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSupports repeatable research workflows\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eKit Contents \u0026amp; Pricing (EXW US Dollar)\u003c\/h2\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProduct Description\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePackage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eShelf Life\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePrice\/Kit (USD)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCPT (USD\/Test)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTB Mycobacterium Tuberculosis Antibody IgG ELISA Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e96 Tests\/Box\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e18 Months\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$38.00\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$0.3958\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eCost per test:\u003c\/strong\u003e approximately \u003cstrong\u003e$0.40\u003c\/strong\u003e, based on a 96-test kit configuration.\u003c\/p\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSpecification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDetail\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eModel \/ SKU\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGHM TB Mycobacterium Tuberculosis Antibody IgG ELISA Kit US\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eProduct Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEnzyme-Linked Immunosorbent Assay (ELISA) Kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIntended Use\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSemi-quantitative determination of anti-\u003cem\u003eM. tuberculosis\u003c\/em\u003e antibody IgG in human serum or plasma; \u003cstrong\u003efor laboratory research use only; not for use in diagnostic procedures; not for therapeutic use\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAssay Principle\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSolid-phase ELISA with anti-human IgG detection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTarget Analyte\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAnti-\u003cem\u003eMycobacterium tuberculosis\u003c\/em\u003e antibody, immunoglobulin G (IgG) class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eImmunoglobulin Class\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIgG (gamma heavy chain specific; monomeric, bivalent)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAntigen\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eM. tuberculosis\u003c\/em\u003e antigen (whole-cell preparation; protein and glycolipid epitopes)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSpecimen Types\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eHuman serum, plasma\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSpecimen Volume\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e50 µL\/well\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePackage Size\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e96 Tests\/Box\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eShelf Life\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e18 Months\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eReading Wavelength\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e450 nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTotal Incubation Time\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eApproximately 1.5–2.5 hours (protocol-dependent)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePrecision (published benchmark)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIntra-assay CV \u0026lt;10%; inter-assay CV \u0026lt;15%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResult Interpretation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCut-off index based semi-quantitative readout (published benchmark)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCalibration Format\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCut-off index referenced to kit calibrators (not mass-concentration calibrated)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRegulatory Status\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eManufactured under EN ISO 13485 certified quality management system\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhy Laboratories Choose Global Healthcare Medical\u003c\/h2\u003e\n\u003ctable data-sc-row-header=\"true\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eConsideration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGHM TB Mycobacterium Tuberculosis Antibody IgG ELISA Kit US\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSolid-phase ELISA with anti-human IgG detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIgG-isotype specific readout, not total immunoglobulin\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eProtein-antigen–focused IgG readout\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSelectively informative for Ag85, ESAT-6, CFP-10, GroEL2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eMonomeric bivalent binding\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDefined two-site stoichiometry; reproducible capture\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePaired design with the IgM configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eComplementary, non-duplicative isotype information\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance aligned with published antibacterial IgG ELISA benchmarks\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCut-off index based; CV \u0026lt;10%\/\u0026lt;15%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eCost-effective research serology\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e$0.3958 per test; $38.00 per 96-test kit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e18-month shelf life\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eExtended inventory stability\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eStandard 96-well format\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCompatible with routine ELISA equipment\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eISO 13485 certified\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eQuality management system compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eAbout Global Healthcare Medical\u003c\/h2\u003e\n\u003cp\u003eGlobal Healthcare Medical connects clinical laboratories, research institutions, and blood screening centers with diagnostic reagents and analytical systems designed for reliable operation in demanding healthcare environments. The GHM TB Mycobacterium Tuberculosis Antibody IgG ELISA Kit US is part of our professional ELISA reagent portfolio, developed to support standardized, reproducible laboratory workflows.\u003c\/p\u003e\n\u003cp\u003eOur focus is on dependable analytical performance, clear documentation, and responsive support for professional laboratory operations.\u003c\/p\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46773840576556,"sku":null,"price":38.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/TBMycobacteriumTuberculosisAntibodyIgGELISAKit.png?v=1795612964","url":"https:\/\/www.globalhealthcaremedical.com\/products\/ghm-tb-mycobacterium-tuberculosis-antibody-igg-elisa-kit-us-96-well-solid-phase-elisa-for-semi-quantitative-determination-of-anti-m-tuberculosis-igg-in-serum-plasma-96t-kit","provider":"Global Healthcare Medical","version":"1.0","type":"link"}