{"product_id":"ghm852-anesthesia-machine-upgraded-version","title":"GHM852 Anesthesia Machine Upgraded Version #","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe upgraded GHM852 Anesthesia Machine delivers cutting-edge performance with a spacious touchscreen interface, advanced ventilation modes, and comprehensive safety features. Designed to meet the most demanding clinical requirements, this system offers exceptional flexibility and precision for anesthesia delivery across all patient populations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eKey Features:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e15-Inch Color LCD Touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eLarge \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e15-inch color LCD built-in touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with multilingual support provides an intuitive user interface, enabling easy navigation and clear visualization of critical patient data.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eThree-Gas Source Standard Configuration\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eStandard configuration includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoxygen (O₂), nitrous oxide (N₂O), and air (AIR)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e gas sources, ensuring maximum flexibility for diverse anesthesia protocols.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eAdvanced Ventilation Modes\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eComprehensive range of ventilation modes to suit various clinical scenarios:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eVCV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (Volume-Controlled Ventilation)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePCV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (Pressure-Controlled Ventilation)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePCV-VG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (Pressure-Controlled Ventilation – Volume Guaranteed)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eSIMV-VC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (Synchronized Intermittent Mandatory Ventilation – Volume Control)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eSIMV-PC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (Synchronized Intermittent Mandatory Ventilation – Pressure Control)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eSIMV-VG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (Synchronized Intermittent Mandatory Ventilation – Volume Guaranteed)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePSV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (Pressure Support Ventilation)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMAN\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (Manual Ventilation)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eStandard Extracorporeal Circulation (ECC) Function\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eIntegrated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eECC function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e supports cardiopulmonary bypass procedures, expanding the machine's utility in complex cardiac surgeries.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRecruitment Maneuver (RM)\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBuilt-in \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRecruitment Maneuver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e function helps optimize lung volume and improve oxygenation, supporting lung-protective ventilation strategies.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCardiopulmonary Bypass Mode\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eDedicated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecardiopulmonary bypass mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ensures seamless integration with bypass procedures, enhancing workflow during cardiac surgeries.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePrecision Gas Delivery\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eO₂ Flush:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 35–50 L\/min for rapid oxygen delivery\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFlow Rate Trigger:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0.2–15.0 L\/min\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePressure Trigger:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e –20 to –1 cmH₂O\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWide Parameter Setting Ranges\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTidal Volume:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 15–1500 mL\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRespiratory Rate:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 4–100 bpm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eI:E Ratio:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 8:1 – 1:10\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTrigger Window:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 5%–90%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePressure Limit:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 10–100 cmH₂O\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePEEP:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e OFF, 3–30 cmH₂O\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eComprehensive Monitoring Parameters\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eReal-time monitoring of:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTidal Volume (0–3000 mL)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRespiratory Rate (0–120 bpm)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eI:E Ratio (10:1 – 1:10)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eOxygen Concentration (18%–100%)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eAirway Pressure (–20 to 120 cmH₂O)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePEEP (0–70 cmH₂O)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eAdvanced Waveform \u0026amp; Loop Display\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eSimultaneous display of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eany three waveforms and two loops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e on the same screen, enabling comprehensive assessment of patient-ventilator interaction and respiratory mechanics.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eExtensive Optional Functions\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eCustomize the machine to meet specific clinical needs with optional modules:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eEtCO₂ module\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for end-tidal carbon dioxide monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMAC module\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for minimum alveolar concentration monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eSpO₂ module\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for oxygen saturation monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eParamagnetic oxygen sensor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for precise oxygen measurement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eAGSS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (Anesthesia Gas Scavenging System)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNegative pressure suction\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (Pressure Support Indicator)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDesigned for Versatility \u0026amp; Safety\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eSuitable for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eadults, children, and infants\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the GHM852 combines powerful ventilatory function with a human-centered design to deliver safe, reliable anesthesia support across a wide range of clinical environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":45418945970220,"sku":null,"price":17000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/GHM852AnesthesiaMachineUpgradedVersion.png?v=1774856235","url":"https:\/\/www.globalhealthcaremedical.com\/products\/ghm852-anesthesia-machine-upgraded-version","provider":"GlobalHeathcareMedical","version":"1.0","type":"link"}