{"product_id":"heyer-aeon7200a-high-end-anesthesia-machine","title":"Heyer Aeon7200A High-End Anesthesia Machine","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAeon7200A High-End\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efull-capability configuration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e of the Aeon7200A continuous-flow anesthesia workstation, designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoperating room anesthesia and respiratory support\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e where \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecomprehensive ventilation modes, integrated monitoring, and upgrade readiness\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e are operational priorities. It is intended for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einfants, children, and adults\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, including patients \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eweighing over 3 kg\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e as referenced in regulatory documentation\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"2\"\u003e\u003ca href=\"https:\/\/www.vedeng.com\/zhucezheng\/gc\/371926.html\" rel=\"noreferrer\" aria-label=\"10\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eWhere the Standard configuration centers on core anesthesia delivery, the High-End platform exposes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecomplete ventilation mode set\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e — \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIPPV, PCV, SIMV-VC, SIMV-PC, and CPAP\/PS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e — alongside readiness for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eanesthetic gas monitoring (AGM), CO₂ monitoring (mainstream or side-stream), anesthetic gas scavenging (AGSS), and suction system integration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e8.4-inch color touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ealloy breathing system with 1.8 L canister\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e20 mL minimum tidal volume\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edynamic tidal volume compensation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e2-hour integrated battery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e form the shared foundation\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"3\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe platform is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE marked\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and holds \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003evalid registrations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e including \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMDA Malaysia (GC2859922-101109, 2022–2027)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChina NMPA (国械注准20163080322)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for the Aeon7200A series. Configuration, modules, vaporizers, and local registration may vary; confirm the final specification with your supplier.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eComplete Ventilation Mode Set: IPPV, PCV, SIMV-VC, SIMV-PC, and CPAP\/PS\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe High-End configuration exposes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efull Aeon7200A mode ceiling\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIPPV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (Intermittent Positive Pressure Ventilation)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePCV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (Pressure Controlled Ventilation)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSIMV-VC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (Synchronized Intermittent Mandatory Ventilation — Volume Controlled)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSIMV-PC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (Synchronized Intermittent Mandatory Ventilation — Pressure Controlled)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCPAP \/ PS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (Continuous Positive Airway Pressure \/ Pressure Support)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"5\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003equick button\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e switches between \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emanual and automatic ventilation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, supporting workflow transitions during induction, maintenance, and emergence\u003c\/span\u003e\u003cspan class=\"\"\u003e. The mode set is intended to match different anesthesia ventilation requirements across infant, pediatric, and adult patients. Mode selection and parameter settings should always be performed by trained clinical personnel according to local protocols.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"6\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eUpgrade-Ready Monitoring: AGM, CO₂ (Mainstream or Side-Stream), and CO₂ Bypass\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe High-End platform is configured for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional monitoring expansion\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMultiple Anesthetic Gas Monitoring (AGM)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e — referenced as helping clinicians \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003econveniently control gas concentration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"7\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw3o\" rel=\"noreferrer\" aria-label=\"13\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCO₂ monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e — available in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emainstream or side-stream\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e configurations\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"9\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCO₂ bypass function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e — referenced as an optional function\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"10\"\u003e\u003ca href=\"https:\/\/www.indiamart.com\/proddetail\/aeonmed-aeon7200a-workstation-anesthesia-machine-2849119128355.html?pos=5#1\" rel=\"noreferrer\" aria-label=\"12\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThese options are intended to support \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einformed anesthetic management\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e by making gas concentration data available at the point of care. Monitoring module selection and configuration should follow local protocols and the configured accessory set.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eComprehensive Safety Architecture\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe High-End platform carries the full Aeon7200A safety stack:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower-on self-test\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e — can be \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eskipped in emergency situations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and completed later\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"11\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eN₂O cut-off valve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoxygen ratio control valve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"12\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOxygen concentration monitoring system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"13\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAutomatic power-off 10 seconds after switch-off\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in case of accidental operation\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"14\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSafety valve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced at \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e≤10 kPa\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in distributor documentation\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"15\"\u003e\u003ca href=\"https:\/\/www.htsymedical.com\/medical-anesthesia-machine.html\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThese features are intended to support safe anesthesia delivery and are referenced across platform documentation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e8.4-Inch Color Touchscreen with Color-Coded Loops, Waveforms, and Parameters\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e8.4-inch LCD color touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esimultaneous monitoring of loops, waveforms, set parameters, and monitored parameters\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecolor-coded displays\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for efficient interpretation\u003c\/span\u003e\u003cspan class=\"\"\u003e. Waveforms referenced include \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eP-T, F-T, and V-T\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; monitored values include \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePaw, Ppeak, Pplat, Pmean, MV, Vt, breath rate, FiO₂, and compliance\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSpirometry loops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e are referenced as supporting interpretation of ventilation effectiveness\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"16\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.indiamart.com\/proddetail\/aeonmed-aeon7200a-workstation-anesthesia-machine-2849119128355.html?pos=5#1\" rel=\"noreferrer\" aria-label=\"12\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/aeonmed.ecvery.com\/products\/emergency-clinics-apparatus\/p2826368\/anaesthesia-machine-system-aeon7200a.html?__cf_chl_rt_tk=fYe_B1Nv1KziLFWZu2z8NrTjNH7QpCa7YZ4gb6oU5LY-1767268302-1.0.1.1-QitHPjo3aMLxCIOvNevCXG3h18MQIA2Y3ep4hUZAiW0\" rel=\"noreferrer\" aria-label=\"17\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eAccurate Tidal Volume Delivery: 20 mL Minimum, Dynamic Compensation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe platform supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etidal volume from 20 mL to 1500 mL\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eminimum 20 mL\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced as suitable for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einfant, pediatric, and adult patients\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edynamic compensation system for tidal volume\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvanced electromagnetic valve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e are referenced as ensuring \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eaccurate tidal volume and compensation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. This supports consistent volume delivery across the patient range.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"19\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/aeonmed.ecvery.com\/products\/emergency-clinics-apparatus\/p2826368\/anaesthesia-machine-system-aeon7200a.html?__cf_chl_rt_tk=fYe_B1Nv1KziLFWZu2z8NrTjNH7QpCa7YZ4gb6oU5LY-1767268302-1.0.1.1-QitHPjo3aMLxCIOvNevCXG3h18MQIA2Y3ep4hUZAiW0\" rel=\"noreferrer\" aria-label=\"17\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eAlloy Breathing System with 1.8 L Canister\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ealloy breathing system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e1.8 L canister\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced as meeting \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elong operating time\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e requirements\u003c\/span\u003e\u003cspan class=\"\"\u003e. The alloy construction supports durability and repeated use workflows in operating room environments.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"21\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eIntegrated 2-Hour Battery and Pneumatic Drive\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe Aeon7200A is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epneumatically driven and electronically controlled\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintegrated battery providing 2 hours of backup (DC 24V, minimum 120 minutes)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced across technical sources\u003c\/span\u003e\u003cspan class=\"\"\u003e. This supports continuity during power interruption and intra-hospital movement where configured.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"22\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.htsymedical.com\/medical-anesthesia-machine.html\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eOptional AGSS and Suction System for Operating Room Integration\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe High-End configuration is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eready for optional anesthetic gas scavenging (AGSS)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e — referenced as supporting \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epassive and active systems\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e — and an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional suction system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAGSS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is referenced as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eprotecting the device while reducing air pollution in the operating room\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. These upgrades support integration into complete operating room workflows.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"24\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw3o\" rel=\"noreferrer\" aria-label=\"13\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eVaporizer Flexibility: Selectatec-Compatible, Up to 2 Units\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe workstation supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eup to 2 vaporizers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSelectatec-compatible mounting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; agent types referenced include \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHalothane, Enflurane, Isoflurane, and Sevoflurane\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Vaporizer models referenced in regulatory listings include \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVP300 and VP500\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"26\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.vedeng.com\/zhucezheng\/gc\/371926.html\" rel=\"noreferrer\" aria-label=\"10\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/aeonmed.ecvery.com\/products\/emergency-clinics-apparatus\/p2826368\/anaesthesia-machine-system-aeon7200a.html?__cf_chl_rt_tk=fYe_B1Nv1KziLFWZu2z8NrTjNH7QpCa7YZ4gb6oU5LY-1767268302-1.0.1.1-QitHPjo3aMLxCIOvNevCXG3h18MQIA2Y3ep4hUZAiW0\" rel=\"noreferrer\" aria-label=\"17\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDevice Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eContinuous-flow anesthesia workstation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAeon7200A (High-End configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eManufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBeijing Aeonmed Co., Ltd.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eHeyer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (post-2019 Aeonmed–HEYER merger)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePatient Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eInfants, children, and adults\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e\u0026gt;3 kg\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced in NMPA registration documentation\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"29\"\u003e\u003ca href=\"https:\/\/www.vedeng.com\/zhucezheng\/gc\/371926.html\" rel=\"noreferrer\" aria-label=\"10\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDrive \/ Control\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003ePneumatically driven and electronically controlled\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"30\"\u003e\u003ca href=\"https:\/\/aeonmed.ecvery.com\/products\/emergency-clinics-apparatus\/p2826368\/anaesthesia-machine-system-aeon7200a.html?__cf_chl_rt_tk=fYe_B1Nv1KziLFWZu2z8NrTjNH7QpCa7YZ4gb6oU5LY-1767268302-1.0.1.1-QitHPjo3aMLxCIOvNevCXG3h18MQIA2Y3ep4hUZAiW0\" rel=\"noreferrer\" aria-label=\"17\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWorking Modes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eClosed, semi-closed, semi-open\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"31\"\u003e\u003ca href=\"https:\/\/www.htsymedical.com\/medical-anesthesia-machine.html\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVentilation Modes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eIPPV, PCV, SIMV-VC, SIMV-PC, CPAP\/PS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eManual\/Auto quick switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"32\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTidal Volume (VT)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e20–1500 mL\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (minimum \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e20 mL\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced for infant\/pediatric suitability)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"33\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVentilation Frequency\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e4–100 bpm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"34\"\u003e\u003ca href=\"https:\/\/aeonmed.ecvery.com\/products\/emergency-clinics-apparatus\/p2826368\/anaesthesia-machine-system-aeon7200a.html?__cf_chl_rt_tk=fYe_B1Nv1KziLFWZu2z8NrTjNH7QpCa7YZ4gb6oU5LY-1767268302-1.0.1.1-QitHPjo3aMLxCIOvNevCXG3h18MQIA2Y3ep4hUZAiW0\" rel=\"noreferrer\" aria-label=\"17\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eI:E Ratio\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e2:1–1:8\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"35\"\u003e\u003ca href=\"https:\/\/aeonmed.ecvery.com\/products\/emergency-clinics-apparatus\/p2826368\/anaesthesia-machine-system-aeon7200a.html?__cf_chl_rt_tk=fYe_B1Nv1KziLFWZu2z8NrTjNH7QpCa7YZ4gb6oU5LY-1767268302-1.0.1.1-QitHPjo3aMLxCIOvNevCXG3h18MQIA2Y3ep4hUZAiW0\" rel=\"noreferrer\" aria-label=\"17\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePressure Control\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e5–60 cmH₂O\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"36\"\u003e\u003ca href=\"https:\/\/aeonmed.ecvery.com\/products\/emergency-clinics-apparatus\/p2826368\/anaesthesia-machine-system-aeon7200a.html?__cf_chl_rt_tk=fYe_B1Nv1KziLFWZu2z8NrTjNH7QpCa7YZ4gb6oU5LY-1767268302-1.0.1.1-QitHPjo3aMLxCIOvNevCXG3h18MQIA2Y3ep4hUZAiW0\" rel=\"noreferrer\" aria-label=\"17\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePEEP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e0–20 cmH₂O\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"37\"\u003e\u003ca href=\"https:\/\/aeonmed.ecvery.com\/products\/emergency-clinics-apparatus\/p2826368\/anaesthesia-machine-system-aeon7200a.html?__cf_chl_rt_tk=fYe_B1Nv1KziLFWZu2z8NrTjNH7QpCa7YZ4gb6oU5LY-1767268302-1.0.1.1-QitHPjo3aMLxCIOvNevCXG3h18MQIA2Y3ep4hUZAiW0\" rel=\"noreferrer\" aria-label=\"17\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInspiratory Plateau\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e0–50% Ti\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"38\"\u003e\u003ca href=\"https:\/\/aeonmed.ecvery.com\/products\/emergency-clinics-apparatus\/p2826368\/anaesthesia-machine-system-aeon7200a.html?__cf_chl_rt_tk=fYe_B1Nv1KziLFWZu2z8NrTjNH7QpCa7YZ4gb6oU5LY-1767268302-1.0.1.1-QitHPjo3aMLxCIOvNevCXG3h18MQIA2Y3ep4hUZAiW0\" rel=\"noreferrer\" aria-label=\"17\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTrigger Sensitivity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e2–30 L\/min\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"39\"\u003e\u003ca href=\"https:\/\/aeonmed.ecvery.com\/products\/emergency-clinics-apparatus\/p2826368\/anaesthesia-machine-system-aeon7200a.html?__cf_chl_rt_tk=fYe_B1Nv1KziLFWZu2z8NrTjNH7QpCa7YZ4gb6oU5LY-1767268302-1.0.1.1-QitHPjo3aMLxCIOvNevCXG3h18MQIA2Y3ep4hUZAiW0\" rel=\"noreferrer\" aria-label=\"17\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHigh \/ Low Pressure Limits\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e21–80 cmH₂O \/ 0–20 cmH₂O\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"40\"\u003e\u003ca href=\"https:\/\/aeonmed.ecvery.com\/products\/emergency-clinics-apparatus\/p2826368\/anaesthesia-machine-system-aeon7200a.html?__cf_chl_rt_tk=fYe_B1Nv1KziLFWZu2z8NrTjNH7QpCa7YZ4gb6oU5LY-1767268302-1.0.1.1-QitHPjo3aMLxCIOvNevCXG3h18MQIA2Y3ep4hUZAiW0\" rel=\"noreferrer\" aria-label=\"17\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e8.4-inch LCD color touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; color-coded loops, waveforms, and parameters\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"41\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFlowmeters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eDouble-tube mechanical flowmeters for each gas\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (2-gas configuration); \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eO₂: 0–1 \/ 1–10 L\/min; N₂O: 0–1 \/ 1–10 L\/min\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"42\"\u003e\u003ca href=\"https:\/\/aeonmed.ecvery.com\/products\/emergency-clinics-apparatus\/p2826368\/anaesthesia-machine-system-aeon7200a.html?__cf_chl_rt_tk=fYe_B1Nv1KziLFWZu2z8NrTjNH7QpCa7YZ4gb6oU5LY-1767268302-1.0.1.1-QitHPjo3aMLxCIOvNevCXG3h18MQIA2Y3ep4hUZAiW0\" rel=\"noreferrer\" aria-label=\"17\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBreathing System\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eAlloy breathing system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e1.8 L canister\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"43\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGas Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eO₂, N₂O: 0.28–0.6 MPa\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"44\"\u003e\u003ca href=\"https:\/\/www.htsymedical.com\/medical-anesthesia-machine.html\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eO₂ Flush\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e35–75 L\/min\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"45\"\u003e\u003ca href=\"https:\/\/aeonmed.ecvery.com\/products\/emergency-clinics-apparatus\/p2826368\/anaesthesia-machine-system-aeon7200a.html?__cf_chl_rt_tk=fYe_B1Nv1KziLFWZu2z8NrTjNH7QpCa7YZ4gb6oU5LY-1767268302-1.0.1.1-QitHPjo3aMLxCIOvNevCXG3h18MQIA2Y3ep4hUZAiW0\" rel=\"noreferrer\" aria-label=\"17\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSafety Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003ePower-on self-test (skippable)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eN₂O cut-off valve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eO₂ ratio control\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eO₂ concentration monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esafety valve ≤10 kPa\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"46\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.htsymedical.com\/medical-anesthesia-machine.html\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOptional Monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eAGM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCO₂ (mainstream or side-stream)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCO₂ bypass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"48\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.indiamart.com\/proddetail\/aeonmed-aeon7200a-workstation-anesthesia-machine-2849119128355.html?pos=5#1\" rel=\"noreferrer\" aria-label=\"12\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOptional Upgrades\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eAGSS (passive\/active)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSuction system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"50\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVaporizers\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eUp to 2, Selectatec-compatible\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVP300\/VP500\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced; Halothane, Enflurane, Isoflurane, Sevoflurane\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"51\"\u003e\u003ca href=\"https:\/\/www.vedeng.com\/zhucezheng\/gc\/371926.html\" rel=\"noreferrer\" aria-label=\"10\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBattery\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eIntegrated, 2 hours; DC 24V, minimum 120 minutes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"52\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.htsymedical.com\/medical-anesthesia-machine.html\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eAC 100–240 V, 50\/60 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"54\"\u003e\u003ca href=\"https:\/\/www.htsymedical.com\/medical-anesthesia-machine.html\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDimensions (H×W×D)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e1356 × 620 × 849 mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"55\"\u003e\u003ca href=\"https:\/\/www.htsymedical.com\/medical-anesthesia-machine.html\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e110 kg (basic model)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"56\"\u003e\u003ca href=\"https:\/\/www.htsymedical.com\/medical-anesthesia-machine.html\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e10–40°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"57\"\u003e\u003ca href=\"https:\/\/www.htsymedical.com\/medical-anesthesia-machine.html\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eStorage Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e-20–55°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"58\"\u003e\u003ca href=\"https:\/\/www.htsymedical.com\/medical-anesthesia-machine.html\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOperating \/ Storage Humidity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e≤80% \/ ≤93% (non-condensing)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"59\"\u003e\u003ca href=\"https:\/\/www.htsymedical.com\/medical-anesthesia-machine.html\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRegulatory Reference\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eCE marked\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMDA Malaysia GC2859922-101109 (2022–2027)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChina NMPA 国械注准20163080322 (Aeon7200A series)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"60\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.vedeng.com\/zhucezheng\/gc\/371926.html\" rel=\"noreferrer\" aria-label=\"10\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cem\u003e\u003cspan class=\"\"\u003eNote: Battery runtime is referenced as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eminimum 90 minutes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in some Aeonmed technical listings and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eminimum 120 minutes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in others; the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e2-hour (120-minute)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e figure is used here based on the Schiller India and HTSY listings\u003c\/span\u003e\u003cspan class=\"\"\u003e. Dimensions of \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e1356×620×849 mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e are drawn from HTSY Medical’s Aeon7200A-specific table\u003c\/span\u003e\u003cspan class=\"\"\u003e; Aeonmed’s own ecvery listing cites \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e824×1382×680 mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for the same model platform — confirm the exact configured dimensions and weight for your unit with the supplier before publishing.\u003c\/span\u003e\u003c\/em\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"62\"\u003e\u003ca href=\"https:\/\/schillerindia.com\/product\/aeon-7200a-2gas\/\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.htsymedical.com\/medical-anesthesia-machine.html\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the Aeon7200A High-End?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eClinical or Operational Need\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eAeon7200A High-End Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed the complete Aeon7200A ventilation mode ceiling\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eIPPV, PCV, SIMV-VC, SIMV-PC, CPAP\/PS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eManual\/Auto quick switch\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed ready access to anesthetic gas concentration data\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eOptional AGM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCO₂ monitoring (mainstream or side-stream)\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed scavenging and suction integration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eOptional AGSS (passive\/active)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional suction system\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed infant-to-adult tidal volume coverage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e20–1500 mL\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e range with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e20 mL minimum\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed accurate volume delivery\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eDynamic tidal volume compensation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvanced electromagnetic valve\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed a clear, color-coded interface\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e8.4-inch color touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with loops, waveforms, and parameters in color\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed comprehensive safety features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eN₂O cut-off\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eO₂ ratio control\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eO₂ concentration monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eskippable self-test\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed battery backup for continuity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntegrated 2-hour battery (DC 24V, min. 120 min)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed vaporizer flexibility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eSelectatec-compatible\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e2 vaporizers\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":45106040078380,"sku":null,"price":10999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/1_1c6efb73-ae1d-4b17-a9d2-7e1acd05a71f.png?v=1765036370","url":"https:\/\/www.globalhealthcaremedical.com\/products\/heyer-aeon7200a-high-end-anesthesia-machine","provider":"Global Healthcare Medical","version":"1.0","type":"link"}