{"product_id":"heyer-aeon8600a-anesthesia-machine","title":"Heyer Aeon8600A Anesthesia Machine","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAeon8600A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efull-featured anesthesia workstation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e positioned as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e“tailor-made all-round anesthesia workstation”\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e by its manufacturer, combining \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etreatment-grade ventilation modes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emagnesium-aluminium alloy breathing circuit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efully electronic fresh gas control\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eperioperative monitoring tools\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einfant, pediatric, and adult patients\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"2\"\u003e\u003ca href=\"https:\/\/www.heyerglobal.com\/AnesthesiaMachine\/info_96.html\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe platform supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIPPV, PCV, SIMV+PS, PS, and Manual\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e ventilation as standard, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePCV-VG, SIMV-VG, BIVENT, and APRV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced in additional configuration documentation\u003c\/span\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eminimum tidal volume of 10 mL in volume control mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, combined with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePCV-VG and BIVENT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, is referenced as supporting \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eprecise low-tidal-volume delivery during lung-protective ventilation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emagnesium-aluminium alloy breathing circuit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edurability and high-quality anesthetic ventilation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, while \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efully electronic fresh gas setting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emillisecond-level electronic sampling\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edurable control valves\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etrue low-flow anesthesia\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"3\"\u003e\u003ca href=\"https:\/\/www.heyerglobal.com\/AnesthesiaMachine\/info_96.html\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw5y\" rel=\"noreferrer\" aria-label=\"10\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/m.huanlab.com\/08\/42503.html\" rel=\"noreferrer\" aria-label=\"11\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe Aeon8600A is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE marked\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, meeting referenced \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEU clinical requirements\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Optional pathways include \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCO₂ monitoring, anesthetic gas monitoring (AGM), AGSS, CO₂ bypass, ACGO, and vaporizers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Configuration, monitoring modules, and local registration may vary; confirm the final specification with your supplier.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"6\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eAll-Round Anesthesia Workstation for Infant, Pediatric, and Adult Patients\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe Aeon8600A is positioned as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e“tailor-made all-round anesthesia workstation”\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e developed by \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSino-US R\u0026amp;D teams\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. China NMPA registration documentation covers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einfants, children, and adults\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e as intended patient populations, and distributor documentation also references \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eneonatal\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e coverage in certain configurations\u003c\/span\u003e\u003cspan class=\"\"\u003e. This patient range supports one platform across different surgical populations, subject to the configured settings and clinical protocols.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"7\"\u003e\u003ca href=\"https:\/\/www.heyerglobal.com\/AnesthesiaMachine\/info_96.html\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/nulizam.es\/images\/AEONMED\/Quirofanos\/ANESTESIA\/anesthesia%20machine%20aeon8600A.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"22\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.vedeng.com\/zhucezheng\/gc\/312043.html\" rel=\"noreferrer\" aria-label=\"25\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eLung-Protective Ventilation Toolkit: 10 mL Minimum VT, PCV-VG, BIVENT, SI, and PV Loop\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe Aeon8600A integrates a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elung-protective ventilation toolkit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced as supporting reduction of \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epostoperative pulmonary complications (PPCs)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e :\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMinimum tidal volume of 10 mL in volume control mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, enabling precise low-tidal-volume ventilation\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"10\"\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw5y\" rel=\"noreferrer\" aria-label=\"10\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePCV-VG and BIVENT modes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for individualized low-tidal-volume delivery\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"11\"\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw5y\" rel=\"noreferrer\" aria-label=\"10\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eStress Index (SI) monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e to support \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eindividualized PEEP titration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"12\"\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw5y\" rel=\"noreferrer\" aria-label=\"10\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eStatic PV loop tool\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e to guide \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePEEP and tidal volume setting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"13\"\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw5y\" rel=\"noreferrer\" aria-label=\"10\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTwo recruitment maneuver types\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e: \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estepwise PEEP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esustained inflation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"14\"\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw5y\" rel=\"noreferrer\" aria-label=\"10\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThese tools are intended to support \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elung-protective ventilation strategies\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and are referenced as clinical support functions, not as independent outcome guarantees.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eMagnesium-Aluminium Alloy Breathing Circuit\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe breathing circuit is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emanufactured from magnesium-aluminium alloy\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, referenced as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einnovatively designed\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and providing \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ehigh-quality anesthetic ventilation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The alloy construction supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edurability and autoclavability\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with the circuit referenced as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eeasy to remove and clean, fully autoclavable\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (except the O₂ cell and mechanical pressure gauge)\u003c\/span\u003e\u003cspan class=\"\"\u003e. An \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional CO₂ bypass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esoda lime replacement without interrupting ventilation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"15\"\u003e\u003ca href=\"https:\/\/www.heyerglobal.com\/AnesthesiaMachine\/info_96.html\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eFully Electronic Fresh Gas Control for True Low-Flow Anesthesia\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe Aeon8600A features \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efully electronic fresh gas setting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emillisecond-level electronic sampling\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edurable control valves\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, referenced as supporting \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etrue low-flow anesthesia\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003evirtual flowmeter display on screen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e replaces conventional mechanical tube reading with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eelectronic precision\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebacklit flowmeters\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e remain available for visual reference. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCompliance, leakage, fresh gas, and altitude compensation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e are referenced as supporting \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003econsistent ventilation delivery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e across different circuit conditions and altitudes\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"19\"\u003e\u003ca href=\"https:\/\/www.heyerglobal.com\/AnesthesiaMachine\/info_96.html\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e10.4-Inch TFT Color Screen with Touch Key and Navigator Wheel\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e10.4-inch TFT color screen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epressure, volume, and gas monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eP-t, F-t, P-V, and F-V loops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e that can be saved\u003c\/span\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esetting interface\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etouch keys and a navigator wheel knob\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, referenced as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esimple and intuitive\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Monitoring includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePpeak, Pplat, Pmean, PEEP; MV, Vt, Freq; O₂ concentration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional CO₂, anesthetic agent, and MAC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e modules\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"21\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eComprehensive Alarm and Safety Architecture\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe Aeon8600A includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecomprehensive alarm set\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHigh\/Low airway pressure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSustained airway pressure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHigh\/Low minute volume\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHigh\/Low FiO₂\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHigh breath rate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eO₂ supply failure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower failure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eApnea\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAlarm silence\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is referenced at \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e110 seconds\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Additional safety features include \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoxygen supply failure alarm, N₂O cut-off system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eO₂ flush of 25–75 L\/min\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The flowmeter system is referenced as providing a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eminimum 25% oxygen concentration in O₂\/N₂O mixtures\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"23\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eIntegrated 2-Hour Battery and Pneumatic Drive\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe Aeon8600A is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epneumatically driven and electronically controlled\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24 V DC battery providing a minimum of 120 minutes (2 hours)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e of backup\u003c\/span\u003e\u003cspan class=\"\"\u003e. This supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003econtinuity during power interruption\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintra-operative mobility\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e where configured.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"26\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eOptional Monitoring and Upgrade Pathways\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eOptional configurations referenced across platform documentation include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCO₂ monitoring module\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAnesthetic gas monitoring (AGM)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMAC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAGSS (anesthetic gas scavenging system)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCO₂ bypass\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eACGO (auxiliary common gas outlet)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAuxiliary oxygen, suction, auxiliary power source, monitor arm, infusion pump holder\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVaporizers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e: up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e2 units\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, Selectatec-compatible, for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHalothane, Enflurane, Isoflurane, Sevoflurane\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"28\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDevice Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eContinuous-flow anesthesia workstation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAeon8600A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eManufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBeijing Aeonmed Co., Ltd.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eHeyer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (post-2019 Aeonmed–HEYER merger)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePatient Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eInfants, children, and adults\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (NMPA registration); \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eneonatal\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e also referenced in distributor documentation\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDrive \/ Control\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePneumatically driven and electronically controlled\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWorking Modes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClosed, semi-closed, semi-open\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVentilation Modes (Standard)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eIPPV, PCV, SIMV+PS, PS, Manual\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"29\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVentilation Modes (Additional Ref.)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003ePCV-VG, SIMV-VG, BIVENT, APRV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced in distributor documentation\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"30\"\u003e\u003ca href=\"http:\/\/m.huanlab.com\/08\/42503.html\" rel=\"noreferrer\" aria-label=\"11\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTidal Volume (VT)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e10–1,500 mL in volume control\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (CEEC listing); \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e20–1,500 mL\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced in other distributor documentation; confirm configured range\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"31\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw5y\" rel=\"noreferrer\" aria-label=\"10\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMinimum Tidal Volume\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e10 mL\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (volume control mode), referenced for lung-protective ventilation\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"33\"\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw5y\" rel=\"noreferrer\" aria-label=\"10\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVentilation Frequency\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e4–100 bpm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"34\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eI:E Ratio\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e4:1–1:8\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"35\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInspired Pressure Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e5–70 cmH₂O\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"36\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePressure Support Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e3–50 cmH₂O\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"37\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePEEP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eOff, 3–30 cmH₂O\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"38\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTslope\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e0–2 s\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"39\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInspiratory Plateau\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eOff, 5%–60% Ti\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"40\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTrigger Sensitivity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e1–15 L\/min\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"41\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e10.4-inch TFT color screen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; touch key + navigator wheel knob\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGraphs \/ Loops\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eP-t, F-t, P-V, F-V loops (savable)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; optional \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCO₂-t\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"42\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMonitoring\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003ePpeak, Pplat, Pmean, PEEP; MV, Vt, Freq; O₂ concentration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; optional \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCO₂, agent, MAC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"43\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBreathing Circuit Material\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eMagnesium-aluminium alloy\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautoclavable\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (except O₂ cell and mechanical pressure gauge)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"44\"\u003e\u003ca href=\"https:\/\/www.heyerglobal.com\/AnesthesiaMachine\/info_96.html\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCO₂ Absorption\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e2 loose fill (3L) or 2 prepacks\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; optional \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esingle canister (1.8L)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCO₂ bypass optional\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"46\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFlowmeters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eO₂: 0–1 \/ 1–10 L\/min; N₂O: 0–1 \/ 1–10 L\/min; Air: 0–1 \/ 1–12 L\/min; Aux. O₂: 0–15 L\/min\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; backlit\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"47\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGas Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eAir, O₂, N₂O: 280–600 kPa\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"48\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eO₂ Flush\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e25–75 L\/min\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"49\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGas Safety\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eO₂ supply failure alarm; N₂O cut-off system; minimum 25% O₂ in O₂\/N₂O mixture\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"50\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCompensation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eCompliance, leakage, fresh gas, altitude\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"52\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBattery\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e24 V DC, minimum 120 min (2 hours)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"53\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e100–240 V AC, 50\/60 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"54\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDimensions (W×H×D)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e704 × 1,403 × 750 mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"55\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e115 kg\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (including trolley base and 2 vaporizers, without cylinder)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"56\"\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOperating Temperature \/ Humidity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e+10 to +40°C; ≤80% (non-condensing)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"57\"\u003e\u003ca href=\"https:\/\/nulizam.es\/images\/AEONMED\/Quirofanos\/ANESTESIA\/anesthesia%20machine%20aeon8600A.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"22\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eStorage Temperature \/ Humidity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e-20 to +55°C; ≤93% (non-condensing)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"58\"\u003e\u003ca href=\"https:\/\/nulizam.es\/images\/AEONMED\/Quirofanos\/ANESTESIA\/anesthesia%20machine%20aeon8600A.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"22\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRegulatory Reference\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eCE marked\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChina NMPA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (Aeon8600A\/8700A\/8800A series); confirm current local registration with supplier\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cem\u003e\u003cspan class=\"\"\u003eNote: Tidal volume lower limit varies by source: \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e10 mL\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is referenced specifically in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003evolume control mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for lung-protective ventilation (CEEC listing), while \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e20 mL\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e appears as a general ventilator specification in several distributor documents. The 10 mL figure is used in the lung-protection section, and both ranges are noted in the specification table for transparency. Patient range also varies: NMPA registration covers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einfants, children, and adults\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, while some distributor pages reference \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eneonatal\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e coverage in certain configurations. Confirm the exact configured tidal volume range and patient population for your unit with the supplier before publishing.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the Aeon8600A?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eClinical or Operational Need\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eAeon8600A Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed an all-round anesthesia workstation for varied patient populations\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eInfant, pediatric, and adult\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e coverage (NMPA); \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eneonatal\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced in distributor configurations\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed lung-protective ventilation capability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e10 mL minimum VT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePCV-VG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBIVENT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSI monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estatic PV loop\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003erecruitment maneuvers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"59\"\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw5y\" rel=\"noreferrer\" aria-label=\"10\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed precise fresh gas control for low-flow anesthesia\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eFully electronic fresh gas setting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emillisecond sampling\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edurable control valves\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003evirtual flowmeter display\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"60\"\u003e\u003ca href=\"https:\/\/www.heyerglobal.com\/AnesthesiaMachine\/info_96.html\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed a durable, autoclavable breathing circuit\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eMagnesium-aluminium alloy\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e construction, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efully autoclavable\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (except O₂ cell\/gauge)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"61\"\u003e\u003ca href=\"https:\/\/www.heyerglobal.com\/AnesthesiaMachine\/info_96.html\" rel=\"noreferrer\" aria-label=\"1\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/fr.ysenmed.com\/products\/anesthesia-machine-ventilator-aeon8600a\" rel=\"noreferrer\" aria-label=\"3\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed flexible ventilation modes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eIPPV, PCV, SIMV+PS, PS, Manual\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePCV-VG, SIMV-VG, BIVENT, APRV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced in additional documentation\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed comprehensive perioperative monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e10.4-inch TFT screen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eP-t\/F-t\/P-V\/F-V loops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePpeak\/Pplat\/Pmean\/PEEP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMV\/Vt\/Freq\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eO₂\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; optional \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCO₂, agent, MAC\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed safety and alarm coverage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eO₂ failure alarm, N₂O cut-off, 25% min O₂\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapnea\/power failure alarms\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e110-s alarm silence\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed battery backup for continuity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24 V DC, minimum 120 minutes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed optional gas monitoring and scavenging\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCO₂, AGM, AGSS, CO₂ bypass, ACGO\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed vaporizer flexibility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eUp to 2 Selectatec-compatible vaporizers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for common agents\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":45106905186348,"sku":null,"price":17999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/1_bd052ff8-b9da-4a07-b820-0ed4394b479e.png?v=1765081980","url":"https:\/\/www.globalhealthcaremedical.com\/products\/heyer-aeon8600a-anesthesia-machine","provider":"Global Healthcare Medical","version":"1.0","type":"link"}