{"product_id":"heyer-aeon8800a-anesthesia-machine","title":"Heyer Aeon8800A Anesthesia Machine","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAeon8800A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ehigh-level anesthesia workstation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e engineered around \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elung-protective ventilation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eprecise low-tidal-volume delivery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintelligent fresh-gas management\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einfants, children, and adult patients\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. It combines a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emagnesium-aluminium alloy integrated breathing circuit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e35°C constant-temperature heating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eultra-light 0.7 g ceramic inspiratory and expiratory valves\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced as suitable for patients with weak respiratory effort such as infants, and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eminimum tidal volume of 10 mL in volume control mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"1\"\u003e\u003ca href=\"https:\/\/www.aeonmed.com\/index21f0.html?c=show\u0026amp;id=485\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe platform supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eventilator-level ventilation modes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e including \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVCV, PCV, SIMV, PS + Apnea ventilation, PCV-VG, BIVENT, SIMV-VG, and SIMV-PC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, alongside a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edigital flowmeter with ECO-Optimizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced as supporting \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esafe low-flow and minimal-flow anesthesia\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e while reducing anesthetic agent and medical gas waste\u003c\/span\u003e\u003cspan class=\"\"\u003e. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDriven Gas Auto-Switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e function first uses compressed air as drive gas to reduce oxygen consumption\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"2\"\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw5o\" rel=\"noreferrer\" aria-label=\"4\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eClinical tools include \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eStress Index (SI) monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for individualized PEEP titration, a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eStatic PV loop tool\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for PEEP and tidal volume setting, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etwo recruitment maneuver types\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (stepwise PEEP and sustained inflation), \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDriving Pressure (DP) monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecardiopulmonary bypass (CBP) modes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e15.1-inch TFT color touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provides waveform and loop display, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eelectronic flowmeter control\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for O₂, N₂O, and air\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"4\"\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw5o\" rel=\"noreferrer\" aria-label=\"4\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.madeinchina.com\/mall\/show-Anesthesia-Machine-Aeon8800A-Hospital-Medial-Equipment-for-or_675825.html#1\" rel=\"noreferrer\" aria-label=\"5\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe Aeon8800A is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE marked\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, meeting referenced \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eEU clinical requirements\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Optional configurations include \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVP300\/VP500 vaporizers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003espotlight\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eauxiliary folding table\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Confirm the final configuration, vaporizer models, and local registration with your supplier.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"6\"\u003e\u003ca href=\"https:\/\/www.madeinchina.com\/mall\/show-Anesthesia-Machine-Aeon8800A-Hospital-Medial-Equipment-for-or_675825.html#1\" rel=\"noreferrer\" aria-label=\"5\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/www.duolemed.cn\/products\/3894.html\" rel=\"noreferrer\" aria-label=\"20\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eLung-Protective Ventilation Toolkit: 10 mL Minimum VT, PCV-VG, BIVENT, SI, PV Loop, and Recruitment Maneuvers\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe Aeon8800A integrates a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elung-protective ventilation toolkit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced as supporting reduction of \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epostoperative pulmonary complications (PPCs)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"9\"\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw5o\" rel=\"noreferrer\" aria-label=\"4\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMinimum tidal volume of 10 mL in volume control mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, supporting precise low-tidal-volume ventilation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePCV-VG and BIVENT modes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for individualized low-tidal-volume delivery\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eStress Index (SI) monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eindividualized PEEP titration\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eStatic PV loop tool\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e to guide \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePEEP and tidal volume setting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTwo recruitment maneuver types\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e: \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estepwise PEEP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esustained inflation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDriving Pressure (DP) monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (range 0–100 cmH₂O) referenced to guide ventilation parameter adjustment\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"10\"\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/3486411\/Aeonmed-Aeon8800a.html?page=48#manual\" rel=\"noreferrer\" aria-label=\"50\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThese tools are intended to support \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elung-protective ventilation strategies\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and are referenced as clinical support functions, not as independent outcome guarantees.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eMagnesium-Aluminium Alloy Integrated Breathing Circuit with 35°C Heating\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003echaracteristic breathing circuit is made of alloy\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, referenced as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecorrosion-resistant\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and able to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ewithstand repeated high-temperature and high-pressure sterilization\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e134°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e)\u003c\/span\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintegrated heating system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e leverages the alloy’s \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebetter thermal conductivity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eprevent condensation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and support \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epatient comfort\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The circuit includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCO₂ bypass function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAPL valve with fast-release pressure\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eprecisely adjustable upper pressure limits\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"11\"\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw5o\" rel=\"noreferrer\" aria-label=\"4\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.madeinchina.com\/mall\/show-Anesthesia-Machine-Aeon8800A-Hospital-Medial-Equipment-for-or_675825.html#1\" rel=\"noreferrer\" aria-label=\"5\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eUltra-Light 0.7 g Ceramic Valves for Infant and Pediatric Sensitivity\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe breathing circuit is equipped with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eceramic inspiratory and expiratory valves weighing as little as 0.7 g\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, referenced as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esuitable for patients with weak respiratory effort, such as infants and young children\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. This design supports the platform’s \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einfant-to-adult\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e patient coverage.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"15\"\u003e\u003ca href=\"https:\/\/www.aeonmed.com\/index21f0.html?c=show\u0026amp;id=485\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eDigital Flowmeter with ECO-Optimizer and Driven Gas Auto-Switch\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDigital Flowmeter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e makes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efresh gas flow setting easier and more precise\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eelectronic monitoring of O₂, N₂O, and air\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e alongside \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emechanical flowmeter total gas volume monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECO-Optimizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e indicates the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003erecommended fresh gas flow setting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e according to set values and patient needs, supporting \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esafe low-flow and minimal-flow anesthesia\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e while \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ereducing anesthetic agent and medical gas waste\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDriven Gas Auto-Switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e first uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecompressed air as drive gas\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ereduce oxygen consumption\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"16\"\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw5o\" rel=\"noreferrer\" aria-label=\"4\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.madeinchina.com\/mall\/show-Anesthesia-Machine-Aeon8800A-Hospital-Medial-Equipment-for-or_675825.html#1\" rel=\"noreferrer\" aria-label=\"5\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eVentilator-Level Ventilation Modes: VCV, PCV, SIMV, PS + Apnea, PCV-VG, BIVENT\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe Aeon8800A supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eventilator-level ventilation modes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced as suitable for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003evarious clinical situations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, covering \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einfants through adults\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"20\"\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw5o\" rel=\"noreferrer\" aria-label=\"4\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.aeonmed.com\/english757d.html?c=show\u0026amp;id=315\" rel=\"noreferrer\" aria-label=\"12\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVCV (Volume Control Ventilation)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePCV (Pressure Control Ventilation)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSIMV (Synchronized Intermittent Mandatory Ventilation)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePS + Apnea ventilation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePCV-VG (Pressure Control Ventilation — Volume Guaranteed)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBIVENT\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSIMV-VG and SIMV-PC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced in the user manual\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"22\"\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/3486411\/Aeonmed-Aeon8800a.html?page=83#manual\" rel=\"noreferrer\" aria-label=\"34\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eone-key operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports switching between \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emanual and mechanical ventilation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"23\"\u003e\u003ca href=\"https:\/\/www.madeinchina.com\/mall\/show-Anesthesia-Machine-Aeon8800A-Hospital-Medial-Equipment-for-or_675825.html#1\" rel=\"noreferrer\" aria-label=\"5\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e15.1-Inch TFT Color Touchscreen with Comprehensive Monitoring\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e15.1-inch TFT LCD color screen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ehighlighted display\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e of \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emain ventilation parameters, monitored data, and message alerts simultaneously\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Graph display includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eP-T and F-T waveforms\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eP-V and F-V loops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ewaveform save function for real-time contrast\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Monitoring includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etraditional parameters\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e plus \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003especial parameters such as Driving Pressure (DP) and Stress Index (SI)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003econtinuous trend information and discrete events stored and displayed in tables or charts\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"24\"\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw5o\" rel=\"noreferrer\" aria-label=\"4\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.madeinchina.com\/mall\/show-Anesthesia-Machine-Aeon8800A-Hospital-Medial-Equipment-for-or_675825.html#1\" rel=\"noreferrer\" aria-label=\"5\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eClinical Tools: CBP Modes, Gas Consumption Calculations, and Data Connectivity\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe Aeon8800A provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emultiple cardiopulmonary bypass (CBP) modes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e to assist with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecardiopulmonary bypass surgery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. It also provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emedical gas consumption calculations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (O₂, N₂O, and agent) and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCO₂ production calculations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, along with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einternational standard data protocol support\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for connection to hospital internet centers\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"27\"\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw5o\" rel=\"noreferrer\" aria-label=\"4\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eIntegrated 2-Hour Battery and Pneumatic Drive\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe workstation is \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epneumatically and electrically controlled\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDC 24 V, 4 Ah battery providing a minimum of 120 minutes (2 hours)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e of operation\u003c\/span\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecentral-brake casters\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e support mobility within the operating room environment\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"29\"\u003e\u003ca href=\"https:\/\/soportevital.co\/wp-content\/uploads\/2025\/03\/Aeon8800A-AEONMED-Ingles.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"16\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.fr.ysenmedical.com\/products\/aeon8800a-medical-high-end-aeon-anesthesia-machine\" rel=\"noreferrer\" aria-label=\"36\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eCompact Stainless-Steel Work Surface and Storage\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe workstation includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elarge stainless-steel work table with LED light\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efolding table for additional workspace\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efour large-capacity drawers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for storing anesthesia consumables and medications\u003c\/span\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDual OCC rails\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e allow easy installation of additional devices\u003c\/span\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"31\"\u003e\u003ca href=\"https:\/\/soportevital.co\/wp-content\/uploads\/2025\/03\/Aeon8800A-AEONMED-Ingles.pdf#1#1#1\" rel=\"noreferrer\" aria-label=\"16\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/www.duolemed.cn\/products\/3894.html\" rel=\"noreferrer\" aria-label=\"20\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eOptional Vaporizers and Accessories\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eOptional configurations referenced across platform documentation include \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVP300\/VP500 series vaporizers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebimetallic temperature compensation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSevoflurane, Isoflurane, and Enflurane\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003espotlight with LED light source\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eauxiliary folding table\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"34\"\u003e\u003ca href=\"https:\/\/www.madeinchina.com\/mall\/show-Anesthesia-Machine-Aeon8800A-Hospital-Medial-Equipment-for-or_675825.html#1\" rel=\"noreferrer\" aria-label=\"5\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/www.duolemed.cn\/products\/3894.html\" rel=\"noreferrer\" aria-label=\"20\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDevice Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eContinuous-flow anesthesia workstation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAeon8800A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eManufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBeijing Aeonmed Co., Ltd.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBrand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eHeyer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (post-2019 Aeonmed–HEYER merger)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePatient Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eInfants, children, and adults\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (NMPA registration); distributor documentation also references \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eneonatal\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e coverage\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"36\"\u003e\u003ca href=\"https:\/\/www.madeinchina.com\/mall\/show-Anesthesia-Machine-Aeon8800A-Hospital-Medial-Equipment-for-or_675825.html#1\" rel=\"noreferrer\" aria-label=\"5\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/www.duolemed.cn\/products\/3894.html\" rel=\"noreferrer\" aria-label=\"20\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDrive \/ Control\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003ePneumatically and electrically controlled\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e continuous airflow workstation\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"38\"\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/3486411\/Aeonmed-Aeon8800a.html#1\" rel=\"noreferrer\" aria-label=\"49\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVentilation Modes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVCV, PCV, SIMV, PS + Apnea, PCV-VG, BIVENT, SIMV-VG, SIMV-PC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTidal Volume (VT)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e10–1,500 mL\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (10 mL minimum in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003evolume control mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e); \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e20–300 mL (child), 20–1,500 mL (adult)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e per user manual\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"39\"\u003e\u003ca href=\"https:\/\/www.reachmedicalsystems.com\/aeonmed\/aeon8800a\" rel=\"noreferrer\" aria-label=\"32\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/3486411\/Aeonmed-Aeon8800a.html?page=79#manual\" rel=\"noreferrer\" aria-label=\"33\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVentilation Frequency\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e2–100 breaths\/min\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"40\"\u003e\u003ca href=\"https:\/\/www.reachmedicalsystems.com\/aeonmed\/aeon8800a\" rel=\"noreferrer\" aria-label=\"32\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePEEP\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e0–30 cmH₂O (optional)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; user manual cites \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3–30 cmH₂O\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"41\"\u003e\u003ca href=\"https:\/\/www.madeinchina.com\/mall\/show-Hospital-Medical-Equipment-Anesthetic-Worksation-with-Ventilator-with-Vaporizer-Aeon8800A_675823.html#1\" rel=\"noreferrer\" aria-label=\"6\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.reachmedicalsystems.com\/aeonmed\/aeon8800a\" rel=\"noreferrer\" aria-label=\"32\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/3486411\/Aeonmed-Aeon8800a.html?page=79#manual\" rel=\"noreferrer\" aria-label=\"33\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e15.1-inch TFT LCD color screen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"42\"\u003e\u003ca href=\"https:\/\/www.madeinchina.com\/mall\/show-Anesthesia-Machine-Aeon8800A-Hospital-Medial-Equipment-for-or_675825.html#1\" rel=\"noreferrer\" aria-label=\"5\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGraphs \/ Loops\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eP-T, F-T waveforms; P-V, F-V loops; waveform save function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"43\"\u003e\u003ca href=\"https:\/\/www.madeinchina.com\/mall\/show-Anesthesia-Machine-Aeon8800A-Hospital-Medial-Equipment-for-or_675825.html#1\" rel=\"noreferrer\" aria-label=\"5\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSpecial Monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eDriving Pressure (DP): 0–100 cmH₂O; Stress Index (SI): 0.100–5.000\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"44\"\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/3486411\/Aeonmed-Aeon8800a.html?page=48#manual\" rel=\"noreferrer\" aria-label=\"50\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBreathing Circuit\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eMagnesium-aluminium alloy integrated circuit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautoclavable up to 134°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e35°C constant-temperature heating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCO₂ bypass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"45\"\u003e\u003ca href=\"https:\/\/www.aeonmed.com\/index21f0.html?c=show\u0026amp;id=485\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.madeinchina.com\/mall\/show-Anesthesia-Machine-Aeon8800A-Hospital-Medial-Equipment-for-or_675825.html#1\" rel=\"noreferrer\" aria-label=\"5\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eValves\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eCeramic inspiratory\/expiratory valves, 0.7 g\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"47\"\u003e\u003ca href=\"https:\/\/www.aeonmed.com\/index21f0.html?c=show\u0026amp;id=485\" rel=\"noreferrer\" aria-label=\"2\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFlowmeters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eDigital electronic flowmeter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for O₂, N₂O, air; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emechanical flowmeter total gas volume monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"48\"\u003e\u003ca href=\"https:\/\/www.madeinchina.com\/mall\/show-Anesthesia-Machine-Aeon8800A-Hospital-Medial-Equipment-for-or_675825.html#1\" rel=\"noreferrer\" aria-label=\"5\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFresh Gas Management\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eECO-Optimizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for recommended low-flow setting; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDriven Gas Auto-Switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (air drive gas first)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"49\"\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw5o\" rel=\"noreferrer\" aria-label=\"4\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClinical Tools\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eCBP modes; gas consumption calculations (O₂, N₂O, agent); CO₂ production calculation; data protocol for hospital network\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"50\"\u003e\u003ca href=\"https:\/\/ceec.fastexpo.cn\/exhibitor\/ph7dnqjogw\/exhibit\/xbtdwc3igw5o\" rel=\"noreferrer\" aria-label=\"4\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVaporizers (Optional)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eVP300\/VP500\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, bimetallic temperature compensation; Sevoflurane, Isoflurane, Enflurane\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"51\"\u003e\u003ca href=\"http:\/\/www.duolemed.cn\/products\/3894.html\" rel=\"noreferrer\" aria-label=\"20\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBattery\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eDC 24 V, 4 Ah, minimum 120 min (2 hours)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"52\"\u003e\u003ca href=\"https:\/\/www.fr.ysenmedical.com\/products\/aeon8800a-medical-high-end-aeon-anesthesia-machine\" rel=\"noreferrer\" aria-label=\"36\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDimensions (H×W×D)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e1,403 × 704 × 750 mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (without yoke)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"53\"\u003e\u003ca href=\"https:\/\/www.fr.ysenmedical.com\/products\/aeon8800a-medical-high-end-aeon-anesthesia-machine\" rel=\"noreferrer\" aria-label=\"36\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWeight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e110 kg (basic unit)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"54\"\u003e\u003ca href=\"https:\/\/www.fr.ysenmedical.com\/products\/aeon8800a-medical-high-end-aeon-anesthesia-machine\" rel=\"noreferrer\" aria-label=\"36\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRegulatory Reference\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eCE marked\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (EU clinical requirements)\u003c\/span\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChina NMPA 国械注准20193081664\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (Aeon8600A\/8700A\/8800A series)\u003c\/span\u003e\u003cspan class=\"_5f9bba8\" data-citation-group=\"55\"\u003e\u003ca href=\"https:\/\/www.madeinchina.com\/mall\/show-Anesthesia-Machine-Aeon8800A-Hospital-Medial-Equipment-for-or_675825.html#1\" rel=\"noreferrer\" aria-label=\"5\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.vedeng.com\/zhucezheng\/gc\/312043.html\" rel=\"noreferrer\" aria-label=\"22\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.vedeng.com\/qixie\/558397.html\" rel=\"noreferrer\" aria-label=\"40\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cem\u003e\u003cspan class=\"\"\u003eNote: Tidal volume ranges vary by source: \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e10–1,500 mL\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is referenced for volume control mode, while the user manual cites \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e20–300 mL (child), 20–1,500 mL (adult), and 10–1,500 mL (adult optional)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for different configurations. PEEP is referenced as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e0–30 cmH₂O (optional)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in one distributor listing and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3–30 cmH₂O\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in the user manual. Patient range includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einfant to adult\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in NMPA documentation, with some distributor listings adding \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eneonatal\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e coverage. Confirm the exact configured tidal volume range, PEEP range, and patient population for your unit with the supplier before publishing.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the Aeon8800A?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eClinical or Operational Need\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eAeon8800A Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed lung-protective ventilation capability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e10 mL minimum VT (volume control)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePCV-VG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBIVENT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eStatic PV loop\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003erecruitment maneuvers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDP monitoring\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed precise low-tidal-volume delivery for small patients\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e10 mL minimum VT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e0.7 g ceramic valves\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced for weak respiratory effort\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed condensation control and circuit durability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eMagnesium-aluminium alloy circuit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e35°C heating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautoclavable to 134°C\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed intelligent fresh-gas management for low-flow anesthesia\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eDigital flowmeter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECO-Optimizer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDriven Gas Auto-Switch\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed ventilator-level ventilation modes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVCV, PCV, SIMV, PS + Apnea, PCV-VG, BIVENT, SIMV-VG, SIMV-PC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed comprehensive monitoring and clinical tools\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e15.1-inch touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDP\/SI monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCBP modes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003egas consumption calculations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etrend storage\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed battery backup for continuity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDC 24 V, 4 Ah, minimum 120 minutes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed a compact, mobile workstation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e1,403 × 704 × 750 mm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e110 kg\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, central-brake casters\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed storage and workspace\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eStainless-steel work table with LED light\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efolding table\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efour large drawers\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed vaporizer flexibility\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eVP300\/VP500 optional\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, Sevoflurane\/Isoflurane\/Enflurane\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":45106915803180,"sku":null,"price":21999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/Heyer_Aeon8800A_Anesthesia_Machine.png?v=1795028353","url":"https:\/\/www.globalhealthcaremedical.com\/products\/heyer-aeon8800a-anesthesia-machine","provider":"Global Healthcare Medical","version":"1.0","type":"link"}