{"product_id":"imac-1800-high-end-18-channel-ecg-machine","title":"iMAC 1800 High-end 18-Channel ECG Machine","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWorld First 18-Channel Resting ECG. Complete Visibility. Superior Detection.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1. Revolutionary 18-Channel Acquisition\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe world's first 18-channel resting ECG machine.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eComplete Cardiac Coverage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Simultaneously observes right ventricular and posterior wall, greatly increasing detection rates of myocardial infarction in these critical areas.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eSolves Clinical Limitations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Effectively addresses the problem that normal 12-lead ECG machines cannot observe multiple cardiac regions at the same time.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eImproves Diagnostic Accuracy \u0026amp; Timeliness\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Enhances detection of myocardial infarction and myocardial ischemia.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2. Exceptional Signal Accuracy\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eEngineered to capture every electrical signal with precision.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e32,000 Hz Digital Sampling Rate\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Ultra-high resolution for detailed waveform analysis.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e24-bit A\/D Conversion\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – 24 sampling data points per channel for exceptional signal fidelity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e0.01-350 Hz Frequency Response\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Ultra-wide range captures signals from pediatric to elderly patients.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1 Second Baseline Stability\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Consistent, reliable baseline for accurate measurements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRecords Weak Signals Accurately\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Captures low-amplitude signals that other systems may miss.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDual-Chamber Pacing Detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Supports double-pole pacemaker detection for paced patients.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e3. Glasgow ECG Analysis Algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eTrusted worldwide with industry-leading performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eSuperior STEMI Detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – ST segment elevation myocardial infarction diagnosis ability is in the industry leading position. Studies show the Glasgow algorithm is more specific than cardiologists in reporting STEMI.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eClinically Validated\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – AHA and CSE database certified.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePatient-Specific Interpretation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – The only algorithm that utilizes age, gender, race, and medication history in making an interpretation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eProven Accuracy\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Clinical data (601 male myocardial infarction patients):\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eAge 18-39: iMAC 100% vs. Cardiologists 87% diagnostic effective rate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eAge 40-49: iMAC 96% vs. Cardiologists 87%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eAge 50-59: iMAC 93% vs. Cardiologists 90%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eAge 60-69: iMAC 93% vs. Cardiologists 82%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eAge 70-79: iMAC 92% vs. Cardiologists 91%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e4. Advanced Analysis Capabilities\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eVectorcardiography (VCG)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Advanced spatial analysis of cardiac electrical activity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTime VCG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Temporal vector analysis for comprehensive assessment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eVentricular Late Potentials (VLP)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Detection of arrhythmogenic substrates.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e5. Original iFilter™ Adaptive Filtering Technology\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSignificantly improves ECG signal quality by reducing noise and artifacts, ensuring clean, diagnostic-quality tracings even in challenging environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e6. Large Intuitive User Interface\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e15\" Large High-Resolution LED Screen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Crystal-clear waveform display.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eStandard Fundamental Grid Design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Familiar layout for rapid interpretation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eIntuitive \u0026amp; Convenient Workflow Design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Minimizes exam time.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eF1-F7 Shortcut Buttons\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – One-touch access to frequently used functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eStandard Alphanumeric Keyboard\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Easy patient data entry.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTrackball\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Intuitive navigation through menus and waveforms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e7. Measurement Accuracy Validated\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eMeets or exceeds IEC60601-2-51 latest requirements:\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eiMAC Results (Avg Deviation)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eIEC Requirement\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eP-wave time limit (ms)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePR Interval (ms)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-1.9 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eQRS Complex (ms)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eQT Interval (ms)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±30 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eSection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eRecommendation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eHero Image\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUse a high-quality image showing the 15\" LED screen with the trackball and keyboard.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eVideo Demo\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eEmbed short clips showing:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e18-lead placement and simultaneous acquisition\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eGlasgow Algorithm auto-diagnosis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with patient-specific factors (age\/gender\/race\/medication)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eVCG, Time VCG, and VLP analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDual-chamber pacing detection\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTechnical Specs Tab\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eList: 18 channels, 32,000Hz sampling rate, 24-bit A\/D conversion, 0.01-350Hz frequency response, 15\" LED screen, pacing detection (dual-chamber), analysis modes (VCG, Time VCG, VLP), connectivity, power requirements, dimensions, weight.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eComparison Chart\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eCreate a powerful comparison against standard 12-lead ECG machines:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eiMAC 1800 (18-lead)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Complete right ventricular + posterior wall view, world-first 18-channel, Glasgow algorithm with patient-specific factors, superior STEMI detection\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eStandard 12-lead ECG\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Limited to anterior\/inferior\/lateral views, misses right ventricular and posterior MIs, basic interpretation only\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eKey Clinical Benefits\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eEmphasize with data:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eWorld-first 18-channel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Uniquely positioned in the market\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRight ventricular \u0026amp; posterior wall MI detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Greatly increased detection rates\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eGlasgow algorithm outperforms cardiologists\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Show the 18-39 age group: 100% vs 87%\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePatient-specific interpretation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Only algorithm using age, gender, race, medication history\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIEC60601-2-51 compliant\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Validated measurement accuracy\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTarget Audience\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eList ideal users:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ Hospital cardiology departments (especially CCU\/ICU)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ Emergency departments (rapid STEMI rule-out)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ Chest pain centers \u0026amp; cardiac clinics\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ Academic medical centers (teaching VCG\/VLP)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ Large health systems requiring advanced ECG capabilities\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e✓ Research institutions\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eClinical Evidence Section\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eCreate a dedicated \"Clinical Validation\" tab showing:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e601 patient study\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – iMAC vs. cardiologists diagnostic rates by age group\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIEC60601-2-51 compliance table\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAHA and CSE database certification\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSTEMI detection comparison\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Glasgow vs. ESC\/AAC criteria\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePacing Highlight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFeature \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edual-chamber pacemaker detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e prominently – many ECG machines cannot accurately capture pacing spikes from both atrial and ventricular leads.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":45432202199084,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/iMAC1800High-end18-ChECGMachine.png?v=1775278157","url":"https:\/\/www.globalhealthcaremedical.com\/products\/imac-1800-high-end-18-channel-ecg-machine","provider":"Global Healthcare Medical","version":"1.0","type":"link"}