{"product_id":"rt-2100-microplate-reader-8-channel-elisa-reader-with-5-second-whole-plate-reading","title":"RT-2100 Microplate Reader | 8‑Channel ELISA Reader with 5‑Second Whole‑Plate Reading","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e8‑channel microplate ELISA reader with 5‑second whole‑plate reading, 100‑program memory, 10,000‑sample storage, and powerful QC functions. Ideal for clinical labs, research, and food safety.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGlobal Healthcare Medical RT-2100 Microplate Reader\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high‑performance, 8‑channel ELISA reader engineered for accurate and efficient microplate analysis in clinical, research, and industrial laboratories. Featuring a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elarge LCD display\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintuitive Windows‑based operation software\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etouch screen or mouse interface\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, this microplate reader delivers exceptional usability and workflow efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eWith its\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e8‑channel optical fiber system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, the RT-2100 completes whole‑plate reading in just\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5 seconds\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—significantly reducing processing time in busy laboratory environments. The system supports\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebichromatic measurement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand a comprehensive range of calculation modes, including\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eabsorbance, cut‑off, curve, linear regression, index regression, logarithm regression, exponent regression, and power regression\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. Whether you're performing ELISA assays in clinical diagnostics, food safety testing, or veterinary applications, the RT‑2100 delivers the speed, accuracy, and versatility you need.\u003c\/span\u003e\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cem\u003e\u003cspan class=\"\"\u003eThis device is intended for professional use in laboratory settings by trained professionals. Not a substitute for professional medical diagnosis.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e⚡ Ultra‑Fast 5‑Second Whole‑Plate Reading\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe RT-2100 is equipped with an\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e8‑channel optical fiber system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethat enables\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecomplete 96‑well plate reading in just 5 seconds\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. This exceptional speed dramatically improves laboratory throughput, reducing wait times and increasing productivity in high‑volume testing environments. The system supports both\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esingle‑wavelength and bichromatic measurement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emodes for enhanced accuracy and flexibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e🖥️ Intuitive Windows‑Based Operation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe microplate reader features\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eeasy Windows operation software\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewith a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elarge LCD display\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand supports both\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etouch screen and mouse input\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. This user‑friendly interface simplifies assay setup, data collection, and result interpretation—minimizing training time and reducing the risk of operator error. The software supports\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eeasy upgrade via SD card\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand is compatible with\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eUSB mouse and keyboard\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efor flexible data entry.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e📊 Comprehensive Calculation Modes\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe RT-2100 offers a versatile suite of calculation modes to accommodate diverse assay requirements:\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eCalculation Mode\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eApplication\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAbsorbance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eDirect optical density measurement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCut‑off\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eQualitative ELISA interpretation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCurve\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eStandard curve‑based quantification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLinear Regression\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLinear standard curve fitting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIndex Regression\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eIndex‑based calculations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLogarithm Regression\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLog‑transformed curve fitting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eExponent Regression\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eExponential curve fitting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower Regression\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePower‑law curve fitting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e💾 Large Memory Storage Capacity\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe RT-2100 offers substantial onboard storage for comprehensive data management:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e100 programs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Store and recall customized assay protocols\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e1,000 patients data\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Manage patient information and test records\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e10,000 sample records\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Archive extensive testing history\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e⚙️ Advanced Quality Control \u0026amp; Multi‑Assay Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePowerful QC function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Supports\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eimmediate QC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eELISA QC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWestgard rules\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLevey‑Jennings plots\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e(optional)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRandom positive and negative control setting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Enhances assay validation and quality assurance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMulti‑assay feature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Enables up to\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12 different assays on one plate\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, maximizing efficiency and reducing reagent waste\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e🔌 Smart Connectivity \u0026amp; Data Management\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCommunication with PC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efor comprehensive data management (optional)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMultiform result output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epatient comprehensive reports\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAutomatic self‑check on power‑on\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Verifies system integrity before each use\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLamp sleeping and wake‑up function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Extends lamp life and reduces energy consumption\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e📋 Comprehensive Reporting\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe RT-2100 generates\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emultiform result output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epatient comprehensive reports\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, facilitating seamless documentation and data sharing. This feature supports efficient record‑keeping for clinical, research, and regulatory compliance purposes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eProduct Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eMicroplate Reader \/ ELISA Reader\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eModel\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eRT‑2100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOptical System\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e8‑channel optical fiber\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eReading Time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e5 seconds per whole plate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMeasurement Modes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSingle‑wavelength, bichromatic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCalculation Modes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAbsorbance, Cut‑off, Curve, Linear Regression, Index Regression, Logarithm Regression, Exponent Regression, Power Regression\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eProgram Storage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e100 programs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePatient Data Storage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1,000 patients\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSample Record Storage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e10,000 sample records\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQC Functions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eImmediate QC, ELISA QC (Westgard rules, Levey‑Jennings plots – optional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMulti‑Assay Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eUp to 12 assays per plate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLarge LCD display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOperation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eTouch screen or mouse; Windows‑based software\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eConnectivity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePC communication (optional), USB mouse\/keyboard support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSoftware Upgrade\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eVia SD card\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSpecial Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAuto self‑check on power‑on, lamp sleep\/wake‑up function, random positive\/negative control setting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eClinical diagnostics, research, food safety, veterinary testing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhat's Included\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eRT-2100 Microplate Reader Main Unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eLarge LCD Display\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eWindows‑Based Operation Software\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003e8‑Channel Optical Fiber System\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003ePower Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eUser Manual\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003e(Software upgrade via SD card)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe RT-2100 Microplate Reader is suitable for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClinical Diagnostics\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– ELISA testing for infectious diseases, hormones, tumor markers, and autoimmune disorders\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eImmunology Laboratories\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Antibody and antigen detection assays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFood Safety Testing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Allergen detection, foodborne pathogen screening\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVeterinary Diagnostics\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Animal disease testing and veterinary ELISA assays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePharmaceutical Research\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Drug development and quality control assays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLife Science Research\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Protein quantification, cytokine analysis, and molecular biology applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePublic Health Laboratories\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Disease surveillance and screening programs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the RT-2100?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eStandard Microplate Readers\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGlobal Healthcare Medical RT-2100\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSlower plate reading times\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e5‑second\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhole‑plate reading – ultra‑fast\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLimited calculation modes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e8 calculation modes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efor maximum flexibility\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSmall storage capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e100 programs, 1,000 patients, 10,000 sample records\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eBasic QC functions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003ePowerful QC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewith Westgard rules and Levey‑Jennings plots (optional)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSingle‑assay capability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eMulti‑assay\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– up to 12 assays per plate\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eManual operation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eWindows‑based\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eintuitive interface with touch screen support\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLimited connectivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003ePC communication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand USB keyboard\/mouse support\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eFAQ\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: What is the RT-2100 Microplate Reader?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eA: The RT-2100 is an 8‑channel microplate ELISA reader featuring 5‑second whole‑plate reading, Windows‑based operation software, comprehensive calculation modes, and powerful quality control functions for clinical, research, and industrial laboratories.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: How fast is the RT-2100?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eA: The RT-2100 completes\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ewhole‑plate reading in just 5 seconds\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethanks to its 8‑channel optical fiber system—significantly reducing processing time in busy laboratory environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: What calculation modes does the RT-2100 support?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eA: The system supports\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eabsorbance, cut‑off, curve, linear regression, index regression, logarithm regression, exponent regression, and power regression\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecalculation modes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: How much data can the RT-2100 store?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eA: The RT-2100 can store\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e100 programs, 1,000 patient data records, and 10,000 sample records\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: Does the RT-2100 support multi‑assay capability?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eA: Yes. The RT-2100 enables\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eup to 12 different assays on one plate\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, maximizing efficiency and reducing reagent waste.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: What quality control functions are available?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eA: The RT-2100 features\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epowerful QC functions\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding immediate QC, ELISA QC with Westgard rules, and Levey‑Jennings plots (optional).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: What type of display and operation does the RT-2100 have?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eA: The RT-2100 features a\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elarge LCD display\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewith\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etouch screen and mouse input\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, running on an intuitive Windows‑based operation software.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: Can the RT-2100 be upgraded?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eA: Yes. The RT-2100 supports\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eeasy software upgrade via SD card\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand is compatible with USB mouse and keyboard.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: What applications is the RT-2100 suitable for?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eA: The RT-2100 is suitable for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eclinical diagnostics, immunology, food safety testing, veterinary diagnostics, pharmaceutical research, life science research, and public health laboratories\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: Does the RT-2100 include automatic self‑check?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eA: Yes. The RT-2100 performs an\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic self‑check on power‑on\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eto verify system integrity before each use.\u003c\/span\u003e\u003c\/p\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":45818659078188,"sku":null,"price":1499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/RT-2100MicroplateReader.png?v=1784365504","url":"https:\/\/www.globalhealthcaremedical.com\/products\/rt-2100-microplate-reader-8-channel-elisa-reader-with-5-second-whole-plate-reading","provider":"Global Healthcare Medical","version":"1.0","type":"link"}