{"product_id":"sonoscape-s80-trolley-color-doppler-ultrasound-system","title":"SonoScape S80 Trolley Color Doppler Ultrasound System","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSonoScape S80\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epremium trolley-based color Doppler ultrasound system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e engineered for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emulti-modality clinical imaging\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e across radiology, obstetrics and gynecology, musculoskeletal, and interventional applications. It is built on SonoScape's \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eC-Field+™ architecture\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, a platform designed around \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eprecise signal-to-noise ratio, spatial and contrast resolution, and frame rate\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, supported by \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintelligent XPUs hybrid hardware\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eaccelerated computing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for boosted processing. The system is positioned as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eflagship systemic-application platform\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, offering a comprehensive clinical solution that spans \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eabdominal, OB\/GYN, MSK, cardiac, and small-parts\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e imaging within a single cart-based configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eS80\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is listed in the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA Establishment Registration \u0026amp; Device Listing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e as the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e“S80 Digital Color Doppler Ultrasound System”\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , under \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eProduct Code IYN (System, Imaging, Pulsed Doppler, Ultrasonic), Class 2, Regulation 892.1550\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePremarket Submission Number K222596\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e cited in the listing. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eK222596 clearance\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e covers the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eS90 Exp Series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, which includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eS80, S80 Elite, S80 Exp, and S80 Plus\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e models. Distributor documentation also references \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE MDR\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e certification for the S80 platform. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNo independent peer-reviewed clinical validation study specific to the S80 was identified in the public literature during preparation of this page.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e Availability, labeling, and cleared claims vary by market.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe imaging chain is anchored by a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epremium transducer portfolio\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003econvex, linear, phased array, volume, and specialty probes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ewideband frequency ranges\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e designed to balance \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eresolution and penetration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eminute detail detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAdvanced hemodynamic tools\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e include \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFHR\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for microvascular structure visualization, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBright Flow\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for 3D-like color Doppler flow without a volume transducer, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMicro F+\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for separating subtle low-velocity flow signals from tissue motion using an innovative \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMatrix E adaptive filter algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe S80 supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edepartment-specific clinical modules\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e: \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eS-MSK\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for automatic musculoskeletal joint section identification, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eS-Fetus®\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for one-click standard fetal plane acquisition and biometry, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSWE\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for liver fibrosis quantification with a quality map, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eATI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for liver steatosis assessment through attenuation coefficient measurement, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eURI-CEUS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for micron-scale angiogram reconstruction, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eContrast HFR\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for high-frame-rate lesion perfusion display, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSonoFusion\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for CT\/MR–ultrasound fusion using a probe-integrated magnetic sensor, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eS-Thyroid\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with ACR TI-RADS-based classification, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eS-Breast\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with BI-RADS standardized reporting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eWorkflow features include \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eProbe Auto Wakeup\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSonoSynch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for real-time remote consultation, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSonoDrop\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for wireless image and report transfer, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSonoAssistant\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for automated protocols, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSonoHelp\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for on-screen tutorials, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSonoTransfer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for Windows-based data sharing. The system is presented with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24-inch LED monitor and 15-inch tilting touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for high-definition viewing and streamlined operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eC-Field+™ Architecture with Intelligent XPUs Hybrid Hardware\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eC-Field+™ platform\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e integrates \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eprecise field imaging transmission\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadaptive aggregation reconstruction\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintelligent XPUs hybrid hardware\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e to optimize \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esignal-to-noise ratio, spatial and contrast resolution, and frame rate\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. This architecture is designed to deliver \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epure signal and refined imaging\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e across different body habitus and clinical applications, within the physical limits of the installed probe set.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003ePremium Transducer Portfolio: Convex, Linear, Phased, Volume, Specialty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe S80 supports a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebroad range of transducers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003econvex array, linear array, phased array, volume probe, and specialty probes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ewideband frequency ranges\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e that balance \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eresolution and penetration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eenhanced minute detail detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eevolutional transducers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e are positioned for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eexcellent 2D image clarity and color sensitivity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, supporting \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003econfident assessment in anatomy and pathology\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eAdvanced Hemodynamics: FHR, Bright Flow, and Micro F+\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFHR\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e enables \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eobservation of microvascular structure within organs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eenhanced sensitivity and improved resolution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBright Flow\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3D-like color Doppler flow visualization without a volume transducer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, strengthening \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003evessel wall boundary definition\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and reducing \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eflow spillover\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMicro F+\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e uses an innovative \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMatrix E adaptive filter algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e to effectively \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efilter out soft tissue and noise signals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, retaining \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eultra-low-velocity fine blood flow signals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and improving \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003espatial resolution for tissue and lesion perfusion assessment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. These are \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eimaging capabilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—clinical value depends on proper probe selection and clinician review.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eDepartment-Specific Clinical Modules: S-MSK, S-Fetus, SWE, ATI, and CEUS\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eS-MSK module\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e automatically identifies \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estandard musculoskeletal joint sections\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and highlights anatomical structures from the cine loop with one click. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eS-Fetus®\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e intelligently identifies \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e29 standard fetal sections\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and automatically obtains \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e13 biometric measurements\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with a single click, supporting \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estandardized and efficient prenatal assessment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSWE (Shear Wave Elastography)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003equantitative liver fibrosis assessment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003equality map\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for measurement reliability, including \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eP-SWE and S-SWE\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e methods. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eATI (Acoustic Attenuation Imaging)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e quantifies \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eliver steatosis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e through \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eattenuation coefficient measurement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eURI-CEUS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e reconstructs \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emicron-scale angiograms\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ehigh-resolution morphological and hemodynamic information\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eContrast HFR\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e dynamically displays \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elesion perfusion at high frame rates\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, combined with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMFI, MFI Time, and Mix mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for multi-perspective perfusion review.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eSonoFusion with Probe-Integrated Magnetic Sensor\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSonoFusion\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e fuses \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eultrasound data with CT\/MR data\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esimultaneous display by image registration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, using a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebuilt-in magnetic sensor in the probe\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—eliminating the need for an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eexternal magnetic sensor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. This supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecomprehensive disease analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e where multimodal correlation is clinically relevant.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eS-Breast and S-Thyroid with Standardized Classification Frameworks\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eS-Breast\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e applies \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBI-RADS guidelines\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estandardized reporting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic lesion boundary extraction and classification\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eS-Thyroid\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edetection and classification of suspicious thyroid lesions based on ACR TI-RADS guidelines\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic boundary definition and report generation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. These tools are \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eclassification and reporting aids\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—they support the clinician's assessment and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edo not constitute a diagnosis on their own\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e24-Inch LED Monitor and 15-Inch Tilting Touchscreen\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe system features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24-inch LED monitor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e15-inch tilting touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, providing \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ehigh-definition viewing and a straightforward workflow\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eergonomically optimized design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eremote access solutions\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e support \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eproductivity in daily clinical operations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eWorkflow Assistants: Probe Auto Wakeup, SonoSynch, SonoDrop, and SonoHelp\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eProbe Auto Wakeup\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e uses an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintelligent motion boost sensor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in the transducer for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eauto activation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emulti-adjustable sensitivity levels\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSonoSynch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e enables \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ereal-time shared interface and camera\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eremote consultation and parameter adjustment across multiple devices\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSonoDrop\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ewireless onsite transfer of images, video, and PDF reports\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSonoAssistant\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e helps \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estreamline workflow, increase standardization, and reduce keystrokes and exam time\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSonoHelp\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eon-screen tutorials with probe placement, anatomy, and reference images\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSonoTransfer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e transfers \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePDF reports, images, and cine to a shared Windows PC folder\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDevice Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eTrolley-based premium color Doppler ultrasound system\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eArchitecture\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eC-Field+™\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with precise field imaging transmission, adaptive aggregation reconstruction, and intelligent XPUs hybrid hardware\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e24-inch LED monitor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e15-inch tilting touchscreen\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTransducer Types\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eConvex, linear, phased array, volume, specialty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; wideband frequency range\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eImaging Modes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eB\/W, Color Doppler, Spectral Doppler, Elastography, Contrast-Enhanced Ultrasound\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHemodynamic Technologies\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFHR, Bright Flow, Micro F+\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClinical Modules\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eS-MSK, S-Fetus®, SWE (P-SWE\/S-SWE), ATI, URI-CEUS, Contrast HFR, SonoFusion, S-Breast (BI-RADS), S-Thyroid (ACR TI-RADS)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFusion Imaging\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eSonoFusion\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eprobe-integrated magnetic sensor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; CT\/MR fusion\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWorkflow Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eProbe Auto Wakeup, SonoSynch, SonoDrop, SonoAssistant, SonoHelp, SonoTransfer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRegulatory Status\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA Device Listing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e: “S80 Digital Color Doppler Ultrasound System”; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eProduct Code IYN\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, Class 2, Regulation 892.1550; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePremarket Submission K222596\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE MDR\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced in distributor documentation; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eno independent peer-reviewed clinical validation study specific to S80 identified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; confirm local registration before purchase\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntended Use\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eMulti-modality ultrasound imaging, measurement, display, and analysis for clinical assessment across abdominal, OB\/GYN, MSK, and related applications by qualified healthcare professionals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the SonoScape S80?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eClinical or Operational Challenge\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eS80 Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed a premium shared-service ultrasound across radiology, OB\/GYN, MSK, and interventional applications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eC-Field+™ architecture\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emulti-modality imaging\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebroad transducer portfolio\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed high image clarity and hemodynamic sensitivity for challenging flow\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eFHR, Bright Flow, and Micro F+\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emicrovascular, 3D-like flow, and low-velocity fine-vessel visualization\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed quantitative tissue characterization for liver, thyroid, and breast assessment\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eSWE\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eliver fibrosis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eATI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eliver steatosis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eS-Breast (BI-RADS)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eS-Thyroid (ACR TI-RADS)\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed automated fetal and MSK standard plane acquisition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eS-Fetus®\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (29 planes, 13 biometry); \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eS-MSK\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (automatic joint section identification)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed multimodal correlation with CT\/MR\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eSonoFusion\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eprobe-integrated magnetic sensor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; no external sensor required\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed efficient workflow and remote collaboration tools\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eProbe Auto Wakeup, SonoSynch, SonoDrop, SonoAssistant, SonoHelp, SonoTransfer\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed high-frame-rate contrast perfusion display\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eContrast HFR\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eURI-CEUS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edynamic lesion perfusion and micron-scale angiogram reconstruction\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed regulatory documentation for U.S. and EU markets\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eFDA Device Listing (IYN, K222596)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE MDR referenced in distributor documentation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; confirm specific model status for local market before purchase\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46594546466860,"sku":null,"price":67999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/SonoScapeS80TrolleyColorDopplerUltrasoundSystem_2.png?v=1793975331","url":"https:\/\/www.globalhealthcaremedical.com\/products\/sonoscape-s80-trolley-color-doppler-ultrasound-system","provider":"Global Healthcare Medical","version":"1.0","type":"link"}