{"product_id":"tlc5000-12-lead-holter-ecg-system-24-hour-ambulatory-ecg-recorder-with-advanced-analysis","title":"TLC5000 12-Lead Holter ECG System | 24-Hour Ambulatory ECG Recorder with Advanced Analysis #","description":"\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12-lead Holter ECG system with 24-hour ambulatory recording, advanced arrhythmia \u0026amp; pacemaker analysis, HRV, and sleep apnea screening. Comprehensive PC-based ECG analysis software.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCONTEC TLC5000 Dynamic ECG System\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a professional 12-lead Holter monitoring solution designed for comprehensive cardiac assessment over a 24-hour period. Adopting an\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einternational standard 12-lead system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, the TLC5000 continuously records ECG waveforms and provides powerful PC-based analysis software for detailed interpretation\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eWith\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvanced arrhythmia analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epacemaker detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and a suite of predictive diagnostic tools including\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHeart Rate Turbulence (HRT)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eT-Wave Alternation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eanalysis, the TLC5000 helps clinicians identify cardiac risks, evaluate myocardial ischemia, and make more informed treatment decisions\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eIdeal for hospitals, cardiology clinics, and community healthcare settings, the TLC5000 delivers the accuracy, flexibility, and comprehensive analysis capabilities required for modern cardiac diagnostics.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003e📊 24-Hour Continuous 12-Lead ECG Recording\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe TLC5000 recorder continuously stores real-time ECG data for a full\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24-hour period\u003c\/span\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e. The system adopts a 12-lead system of international standard, ensuring comprehensive cardiac electrical activity\u003cspan\u003e \u003c\/span\u003ecapture\u003cspan\u003e \u003c\/span\u003ethroughout the monitoring period\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003e🔬 Advanced Arrhythmia Analysis with MCSSTM \u0026amp; TMCATM\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe system features powerful arrhythmia analysis based on\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMCSSTM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTMCATM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003etechnology, which significantly reduces the doctor's workload by automating complex waveform classification\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e. With\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emore than 10 templates\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—including atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, and others—the system can distinguish almost any kind of pathologic waveform\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e. User-defined modules further extend the system's diagnostic capabilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003e🫀 Synchronous 12-Lead Analysis\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe TLC5000 performs\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esynchronous analysis for 12-lead\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, ensuring that QRS waveforms are found accurately without distortion\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e. Flexible analysis channel selection allows any channel to be selected as the main analysis channel, providing physicians with complete control over the diagnostic process\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003e🔄 Comprehensive Pacemaker Analysis\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe system offers\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epowerful pacemaker analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efor all pacemaker types, including\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAAI, VVI, DDD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and others\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e. Multiple pacing analysis templates are available, such as \"Dual chamber pacing,\" \"Atrial pacing,\" \"Ventricular pacing,\" \"Ventricular Pseudofusion,\" and \"Ventricular asynchronous pacing\"\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003e🧠 Predictive Diagnostic Tools\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe TLC5000 goes beyond basic ECG analysis with advanced predictive functions:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSleep Breath Pause Syndrome Analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Predicts the risk of sleep-disordered breathing\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHeart Rate Turbulence (HRT) Analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Predicts death risk in patients with myocardial infarction\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eT-Wave Alternation Analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– An important index for predicting malignant arrhythmia and sudden cardiac death\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eST Segment Analysis \u0026amp; Total Ischemic Load\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Analyzes abnormal ST segments according to the whole and events, helping physicians comprehensively judge myocardial ischemia\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003e🕒 Heart Rate Variability (HRV) Analysis\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe system provides HRV analysis for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5-minute, 1-hour, and 24-hour\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eperiods, offering valuable insights into autonomic nervous system function\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003e📋 Advanced Analysis Modules\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe TLC5000 includes additional analysis modules for more comprehensive reporting:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQTD (QT Dispersion)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eanalysis\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVCG (Vector Cardiogram)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eanalysis\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eVLP (Ventricular Late Potential)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eanalysis\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eTVCG (Time Vector Cardiogram)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eanalysis\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003e🔍 Fast Review \u0026amp; Flexible Reporting\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003efast review analysis function\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallows physicians to review single or full-lead ECG in any time bucket\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOne-key printing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emakes report generation convenient and fast\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003e💾 Perfect Case Management\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe system features comprehensive case management functions for efficient storage, retrieval, and organization of patient records\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan class=\"\"\u003e🖥️ PC-Based Analysis Software\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eComprehensive PC software enables detailed waveform analysis, report generation, and data management, making the TLC5000 a complete Holter ECG solution for medical institutions\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eRecorder Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eTLC5000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLead Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e12-lead (international standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eRecording Duration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e24 hours continuous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e1.77\" TFT color LCD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eMemory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eMicroSD (1GB)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eTwo \"AA\" batteries\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eInterface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eUSB 2.0\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e111mm(L) × 61mm(W) × 25mm(H)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eFeatures\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eWaveform preview, record review, event marking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eAnalysis Software Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDescription\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eArrhythmia Analysis\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eMCSSTM \u0026amp; TMCATM technology with 10+ templates\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePacemaker Analysis\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSupports AAI, VVI, DDD and all pacemaker types\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eHeart Rate Variability\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e5-min, 1-hour, 24-hour analysis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eST Segment Analysis\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eFull and event-based analysis with ischemic load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSleep Apnea Screening\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePredicts risk of sleep breath pause syndrome\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eHRT Analysis\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePredicts death risk in post-MI patients\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eT-Wave Alternation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003ePredicts malignant arrhythmia and sudden cardiac death\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAdvanced Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eQTD, VCG, VLP, TVCG analysis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eCase Management\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eComprehensive storage and retrieval\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eWhy Choose the TLC5000?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBasic Holter Systems\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCONTEC TLC5000\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLimited arrhythmia templates\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e10+ templates + user-defined modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eNo pacemaker analysis\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eComprehensive pacemaker detection (AAI, VVI, DDD, etc.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eBasic ECG reporting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eHRV, HRT, T-Wave Alternation, sleep apnea screening\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSingle-channel focus\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eSynchronous 12-lead analysis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eLimited predictive tools\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eAdvanced risk prediction for sudden cardiac death\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eBasic case management\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003eComprehensive case management system\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eWhether you're a cardiologist, hospital department, or diagnostic center, the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCONTEC TLC5000 12-Lead Holter ECG System\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edelivers the advanced analysis, predictive capabilities, and diagnostic accuracy you need.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eWhat's Included\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eTLC5000 12-Lead Holter Recorder\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003e12-Lead ECG Patient Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003ePC Analysis Software\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eUSB 2.0 Cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eTwo \"AA\" Batteries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eUser Manual\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eSoftware Installation Guide\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eApplications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe TLC5000 Dynamic ECG System is applicable for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHospitals\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Cardiology departments, ICUs, emergency rooms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCardiology Clinics\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Outpatient Holter monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCommunity Health Centers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Remote cardiac screening\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePhysical Examination Centers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Preventive cardiac assessment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSleep Clinics\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Sleep apnea risk screening\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eFAQ\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: What is the recording duration of the TLC5000?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eA: The TLC5000 recorder continuously stores real-time ECG data for a full\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24-hour period\u003c\/span\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: What lead system does the TLC5000 use?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eA: The system adopts an\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003einternational standard 12-lead system\u003c\/span\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: What types of arrhythmia can the system detect?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eA: The TLC5000 features more than 10 templates including atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, and others, with user-defined modules to distinguish almost any kind of pathologic waveform\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: Can the TLC5000 analyze pacemaker patients?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eA: Yes. The system offers powerful pacemaker analysis for all pacemaker types, including\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAAI, VVI, DDD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and others\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: What predictive diagnostic tools are available?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eA: The TLC5000 includes Sleep Breath Pause Syndrome analysis, Heart Rate Turbulence (HRT) analysis for post-MI risk prediction, T-Wave Alternation analysis for sudden cardiac death risk, and ST segment analysis for myocardial ischemia assessment\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: Does the system include Heart Rate Variability analysis?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eA: Yes. The system provides HRV analysis for\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5-minute, 1-hour, and 24-hour\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eperiods\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: What additional analysis modules are available?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eA: The TLC5000 includes QTD (QT dispersion), VCG (vector cardiogram), VLP (ventricular late potential), and TVCG (time vector cardiogram) analysis modules\u003c\/span\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.contecmed.com\/productinfo\/603449.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: What type of memory does the recorder use?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eA: The TLC5000 uses\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMicroSD (1GB)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ememory for data storage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: How is the recorder powered?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eA: The recorder is powered by\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003etwo \"AA\" batteries\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eQ: Can I preview waveforms during recording?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eA: Yes. The TLC5000 features\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ewaveform preview\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, record review, and event marking functions.\u003c\/span\u003e\u003c\/p\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":45755343372332,"sku":null,"price":799.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/TLC5000DynamicECGSystems.png?v=1783143030","url":"https:\/\/www.globalhealthcaremedical.com\/products\/tlc5000-12-lead-holter-ecg-system-24-hour-ambulatory-ecg-recorder-with-advanced-analysis","provider":"GlobalHeathcareMedical","version":"1.0","type":"link"}