{"product_id":"zoncare-imac-300-pro-3-channel-ecg-machine","title":"Zoncare iMAC 300 Pro 3-Channel ECG Machine","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eZoncare iMAC 300 Pro\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecompact, touch-operated 3-channel digital electrocardiograph\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eroutine resting ECG acquisition in clinics, hospitals, and mobile care settings\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. It builds on the iMAC 300 platform with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5-inch super-sensitive capacitive touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (optional on the standard model), \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e20,000-report storage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadvanced Glasgow analysis\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecomprehensive wired and wireless connectivity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—bringing high-capacity ECG management into a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e1.3 kg, hand-carried enclosure\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e that fits within a standard consultation-room footprint.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe iMAC 300 Pro is positioned for \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebusy clinical practices that need reliable 12-lead acquisition with compact 3-channel printing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, alongside the ability to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003estore, review, and export ECG records\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e without a dedicated workstation. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ealphanumeric keyboard and shortcut keys\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e support efficient patient information entry, and the interface can be adapted to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eregional clinical habits\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe acquisition chain includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e32,000 Hz sampling rate\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24-bit A\/D conversion\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e0.01–350 Hz ultra-wide frequency response\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e≥115 dB CMRR\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—parameters oriented toward \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edetecting tiny waveform components\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and supporting \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esignal quality across adult, pediatric, and newborn patients\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eiFilter™ adaptive filtering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e further improves ECG signal quality, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epacemaker detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is supported for patients with implanted devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGlasgow ECG analysis algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomated measurements and interpretive output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e based on patient demographics including \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esex, age, race, and medication history\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—positioned as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eclinical decision support tool\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e that supports the clinician’s review and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edoes not constitute a diagnosis on its own\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMinnesota code\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eR-R histogram\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eaverage template\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e functions are also referenced in the analysis and recording workflow.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe iMAC 300 Pro stores \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eup to 20,000 reports locally\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eUSB, SD card, LAN, and Wi-Fi\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e export. Reports can be transmitted using \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFTP, DICOM, HTTP, and Samba protocols\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and saved in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eZQECG, JPG, PDF, PNG, XML, HL7, DICOM-JPG, DICOM-PDF, and DICOM-WAVEFORM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e formats—supporting \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePACS and hospital information system integration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e where configured. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003erechargeable Li-Ion battery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eover 7 hours of continuous use\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintegrated thermal printer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3×4, 3×4+1, and 1×12\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e print layouts on \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eZ-fold or roll thermal paper\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRegulatory status:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e The iMAC 300 Pro is covered by \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eChina NMPA registration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e , which lists the \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eiMAC 300pro\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e among the covered models. The device is described in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eZoncare documentation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e as carrying \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE and ISO\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e certification, and the broader iMAC ECG family is referenced in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRussian pattern approval (No. 81138-20)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e . \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNo FDA 510(k) clearance specific to the iMAC 300 Pro model name was identified in the public FDA database during preparation of this page\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; distributor documentation references FDA certification for some Zoncare products, but the specific status of this model should be confirmed before U.S. purchase. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNo independent peer-reviewed clinical validation study specific to the iMAC 300 Pro was identified in the public literature during preparation of this page.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e Availability, labeling, and cleared claims vary by market.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e5-Inch Capacitive Touchscreen with Alphanumeric Keyboard\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe iMAC 300 Pro features a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5-inch super-sensitive capacitive touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (optional on the standard iMAC 300), alongside an \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ealphanumeric keyboard and shortcut keys\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for efficient patient information entry. The interface can be \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eadapted to regional clinical habits\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003emultiple languages\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e are supported. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ecompact, ergonomic design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esingle-hand transport\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e between examination rooms and bedside locations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e12-Lead Acquisition with 32,000 Hz Sampling and 0.01–350 Hz Bandwidth\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe system acquires \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e12 leads simultaneously\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3-channel printing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e in \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3×4, 3×4+1, and 1×12\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e layouts. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e32,000 Hz sampling rate\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24-bit A\/D converter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e0.01–350 Hz ultra-wide frequency response\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e are intended to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eimprove the detection of tiny waveform components\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e compared with narrower-band systems. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eiFilter™ adaptive filtering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is designed to \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eimprove ECG signal quality\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCMRR ≥115 dB\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports common-mode noise rejection. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInput impedance is ≥60 MΩ (10 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e per Praxisdienst technical specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eGlasgow ECG Analysis with Pacemaker Detection and Minnesota Code\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eGlasgow ECG analysis algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e provides \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomated interpretive output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e based on patient demographics including \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esex, age, race, and medication history\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epacemaker detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMinnesota code\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic measurement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eR-R histogram and diagram\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eaverage template\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e functions are included in the recording and analysis workflow. These are \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eclinical decision support tools\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e—they support the clinician‘s review and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003edo not constitute a diagnosis on their own\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003e20,000-Report Storage with Comprehensive Export and Connectivity\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe iMAC 300 Pro stores \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eup to 20,000 reports locally\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eUSB, SD card, LAN, and Wi-Fi\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e data transfer. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eReport export formats\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e include \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eZQECG, JPG, PDF, PNG, XML, HL7, DICOM-JPG, DICOM-PDF, and DICOM-WAVEFORM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and transmission supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFTP, DICOM, HTTP, and Samba protocols\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWired and wireless network connectivity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintegration with digital patient records\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePACS environments\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e where configured.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eIntegrated Thermal Printer with Flexible Layouts\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintegrated thermal printer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3×4, 3×4+1, and 1×12\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e manual and automatic print formats on \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eZ-fold or roll thermal paper\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e. An \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eexternal laser printer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is available as an option, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003enetwork printing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e is supported for workflow flexibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eRechargeable Li-Ion Battery with Over 7 Hours of Use\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e10.89 V \/ 2600 mAh Li-Ion battery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eover 7 hours of continuous use\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, alongside \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAC mains operation (100–240 V, 50\/60 Hz, 75 VA)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e . The system includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintegrated defibrillator protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ealerts for bradycardia, tachycardia, lead disconnection, and low battery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e support safe operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eLead-Off Alarm and Clinical Alerts\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLead-off detection and alarm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e support waveform quality assessment before printing, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eclinical alerts for bradycardia and tachycardia\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e draw attention to rate-related findings during acquisition. \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePacemaker detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e supports review of patients with implanted devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eOptional Accessories for Workflow and Mobile Use\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eOptional accessories include a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elifting trolley\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for cart-based deployment, a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ewaterproof and pressure-proof suitcase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for field use, a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebarcode reader\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for sample identification, a \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elaser printer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECG-20NT PC software\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for saving, validating, and archiving ECG data on a PC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDevice Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"\"\u003e3-channel digital resting electrocardiograph\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAcquisition\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e12-lead synchronous acquisition and display\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3-channel printing\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDisplay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e5-inch LCD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003esuper-sensitive capacitive touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (optional on iMAC 300; standard\/optional on iMAC 300 Pro per configuration)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInput\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eAlphanumeric keyboard\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eshortcut keys\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; multiple languages\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSampling Rate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e32,000 samples per second\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eA\/D Conversion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24 bits\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFrequency Response\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e0.01–350 Hz\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCMRR\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e≥115 dB\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInput Impedance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e≥60 MΩ (10 Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePatient Leakage Current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e\u0026lt;10 μA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNoise Level\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e≤10 μVp-p\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCalibration Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e1 mV ±2%\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSensitivity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e2.5, 5, 10, 20, 40 mm\/mV and automatic\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePaper Speed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e5, 6.25, 12.5, 25, 50 mm\/s\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFiltering\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eAC filter, baseline drift, EMG filter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eiFilter™ adaptive filtering\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAnalysis\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eGlasgow ECG analysis algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epacemaker detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMinnesota code\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eautomatic measurement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eR-R histogram and diagram\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eaverage template\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSampling Modes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eReal-time, pre-sampling, triggered sampling\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e4 recording modes\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePrint Layouts\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e3×4, 3×4+1, 1×12\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e manual\/auto\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eThermal Paper\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eZ-fold and roll thermal paper\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInternal Storage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eUp to 20,000 reports\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eData Export Formats\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eZQECG, JPG, PDF, PNG, XML, HL7, DICOM-JPG, DICOM-PDF, DICOM-WAVEFORM\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eData Transfer Protocols\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFTP, DICOM, HTTP, Samba\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eConnectivity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e2 USB ports, LAN, SD card slot, Wi-Fi\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; wired and wireless network connectivity\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eBattery\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eRechargeable Li-Ion 10.89 V \/ 2600 mAh\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eover 7 hours continuous use\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eAC 100–240 V, 50–60 Hz, 75 VA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDimensions \/ Weight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eApproximately 1.3 kg\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e (body); \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eapproximately 1.2 kg\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced for iMAC 300 platform\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSafety Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eIntegrated defibrillator protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elead-off alarm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebradycardia\/tachycardia\/low-battery alerts\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOptional Accessories\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eLifting trolley\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ewaterproof\/pressure-proof suitcase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebarcode reader\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003elaser printer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eECG-20NT PC software\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eSD card\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eUSB disk\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eprojector\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRegulatory Status\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eChina NMPA: \u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e(lists iMAC 300pro among covered models); \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCE and ISO\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e referenced in Zoncare documentation; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRussian pattern approval No. 81138-20\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e for iMAC family; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eno FDA 510(k) specific to iMAC 300 Pro identified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; confirm local registration before purchase\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClinical Evidence\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNo independent peer-reviewed validation study specific to iMAC 300 Pro identified\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003eWhy Choose the Zoncare iMAC 300 Pro?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eClinical or Operational Challenge\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"\"\u003eiMAC 300 Pro Solution\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed a compact 3-channel ECG with touch operation and high-capacity storage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e5-inch capacitive touchscreen\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e20,000-report storage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e1.3 kg\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e enclosure\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed high-resolution waveform capture for detailed ECG review\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e32,000 Hz sampling\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e24-bit A\/D\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e0.01–350 Hz frequency response\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eiFilter™ adaptive filtering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCMRR ≥115 dB\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed automated analysis support with clear advisory labeling\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eGlasgow ECG analysis algorithm\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003epacemaker detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMinnesota code\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; positioned as \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eclinical decision support\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e rather than diagnosis\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed extensive storage and multi-format export for paperless workflow\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e20,000 reports\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eZQECG, JPG, PDF, PNG, XML, HL7, DICOM-JPG, DICOM-PDF, DICOM-WAVEFORM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e export\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed PACS\/HIS integration and network printing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eWi-Fi and wired connectivity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFTP, DICOM, HTTP, Samba\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e protocols; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003enetwork printing support\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed integrated printing with flexible layouts\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eThermal printer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e3×4, 3×4+1, 1×12\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e formats; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eZ-fold and roll paper\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed long battery runtime and defibrillator protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003eLi-Ion battery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e with \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e\u0026gt;7 hours use\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eintegrated defibrillator protection\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eNeed portability with optional trolley and mobile accessories\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e\u003cspan class=\"\"\u003e1.3 kg\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e; \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eoptional lifting trolley\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ewaterproof suitcase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ebarcode reader\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePC software\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Global Healthcare Medical","offers":[{"title":"Default Title","offer_id":46587424079916,"sku":null,"price":1299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/9756\/1388\/files\/ZoncareiMAC300Pro3-ChannelECGMachine_2.png?v=1793880808","url":"https:\/\/www.globalhealthcaremedical.com\/products\/zoncare-imac-300-pro-3-channel-ecg-machine","provider":"Global Healthcare Medical","version":"1.0","type":"link"}