Global Healthcare Medical
Biossays E6 Plus Fully Automatic Electrolyte Analyzer #
Biossays E6 Plus Fully Automatic Electrolyte Analyzer #
Couldn't load pickup availability
Product Overview
The Biossays E6 Plus is a fully automatic electrolyte analyzer designed for accurate and efficient measurement of ionized calcium (iCa²⁺) and other key electrolytes. Featuring a puncture pipettor that eliminates the need for manual decapping, it maintains the maximum anaerobic environment to ensure the stability of ionized calcium levels and measurement accuracy. With its user-centric design, flexible electrode configuration, and connectivity to total laboratory automation systems, the Biossays E6 Plus is the ideal solution for laboratories seeking to streamline electrolyte testing workflows.
Key Features
-
Puncture Pipettor Technology: Equipped with a puncture pipettor that pierces sample tube caps directly—no manual decapping required. This maintains the maximum anaerobic environment, ensuring the stability of ionized calcium levels and measurement accuracy while avoiding biological hazards associated with decapping.
-
Fully Automatic Operation: Automatic sample loading, information reading, and testing minimize hands-on time and improve workflow efficiency.
-
High Throughput: Up to 90 samples per hour (540 tests per hour) with 30 samples loaded in a single operation. Supports continuous loading for uninterrupted testing.
-
Barcode Recognition: Integrated barcode scanner automatically reads sample information for seamless data management.
-
User-Centric Design: 12-inch color LCD touch screen with concise, intuitive interface. Drag-out ISE module and portable electrode replacement ensure convenient maintenance.
-
Flexible Electrode Configuration: Up to 6 electrodes can be configured in any combination to meet your laboratory's specific testing needs.
-
Capacitive Liquid Level Detection: Ensures accurate sample aspiration and reduces sampling errors.
-
Comprehensive Quality Control: Slope tracking chart, Levey-Jennings (L-J) quality control chart, and X̄-M (floating mean quality control) chart for robust quality management.
-
Data Visualization: Real-time instrument status monitoring and data statistics for easy oversight.
-
LIS Connectivity: Supports LIS connection for seamless data integration.
-
Multiple Output Options: Built-in thermal printer with support for external printer connection.
-
Expandable Connectivity: 2 USB, 1 COM, and 1 LAN interfaces for flexible connectivity.
-
Online Program Upgrade: Supports online program upgrades for easy software updates.
Technical Specifications
| Feature | Specification |
|---|---|
| Test Method | Ion Selective Electrodes (direct) |
| Sample Types | Whole blood, serum, urine |
| Throughput | Up to 90 samples/hour (540 tests/hour) |
| Sample Loading | 30 samples per operation, continuous loading |
| Sample Volume | 100 μL |
| Liquid Level Detection | Capacitive liquid level detection |
| Electrodes | Up to 6 electrodes as per request of any combination |
| Software Platform | Android |
| Display | 12-inch color LCD touch screen |
| Data Management | Data statistics and instrument status monitoring |
| Quality Control Charts | Slope tracking chart, Levey-Jennings (L-J) chart, X̄-M (floating mean quality control) chart |
| LIS Connectivity | Supported |
| Result Printing | Built-in thermal printer; supports external printer connection |
| Interfaces | 2 USB, 1 COM, 1 LAN |
| Program Upgrade | Online program upgrade supported |
| Extendibility | Connectable to Total Laboratory Automation System (TLA/LAS) |
Test Menu (Electrode Configuration)
The Biossays E6 Plus measures electrolytes using ion-selective electrode technology. Up to 6 electrodes can be configured in any combination to suit your laboratory's testing requirements.
Available Electrode Parameters
| Parameter | Description |
|---|---|
| iCa²⁺ | Ionized Calcium – Critical for assessing calcium status in conditions such as parathyroid disorders, renal failure, and critical care. Maintained under anaerobic conditions for accuracy. |
| K⁺ | Potassium – Essential for monitoring electrolyte balance in renal disease, cardiac conditions, and acid-base disorders. |
| Na⁺ | Sodium – Key parameter for assessing hydration status, renal function, and acid-base balance. |
| Cl⁻ | Chloride – Important for evaluating electrolyte balance, metabolic disorders, and acid-base status. |
| pH | Measures hydrogen ion concentration for acid-base balance assessment. |
| Reference Electrode | Provides stable reference potential for accurate measurements. |
Why Choose Biossays E6 Plus?
-
Puncture Pipettor Advantage: Eliminates manual decapping, maintaining anaerobic conditions for accurate iCa²⁺ measurement and protecting laboratory staff from biological hazards
-
Fully Automated Workflow: From sample loading to result output, automation reduces manual intervention and improves efficiency
-
High Productivity: Up to 90 samples per hour with continuous loading capability
-
Flexible Configuration: Choose any combination of up to 6 electrodes to match your testing menu requirements
-
User-Friendly Operation: Large touch screen interface with intuitive design simplifies daily operation
-
Easy Maintenance: Drag-out ISE module and portable electrode replacement make maintenance convenient and quick
-
Robust Quality Control: Multiple QC charting options ensure reliable quality management
-
Seamless Integration: LIS connectivity and TLA/LAS compatibility allow integration into existing laboratory workflows
-
Multiple Connectivity Options: USB, COM, and LAN interfaces provide flexibility for data export and networking