High‑throughput automatic chemistry analyzer with 800 tests/hour (1200 with ISE), 12‑wavelength grating system, and 140‑sample capacity. Ideal for clinical laboratories and hospitals.

The Global Healthcare Medical Chemray 800 Automatic Chemistry Analyzer is a future‑ready, random‑access biochemistry system engineered for high‑throughput clinical laboratory testing. Featuring a constant throughput of 800 tests per hour (1,200 tests per hour with integrated ISE module), this analyzer delivers the speed and efficiency required in modern hospital and reference laboratory environments.

Built with advanced optical technology, the Chemray 800 utilizes a grating system with 12 wavelengths for precise photometric measurement across a broad spectrum. Its open system design supports user‑defined profiles and calculation assays, providing exceptional flexibility for diverse testing menus. Whether you are performing routine biochemistry panels or specialized assays, the Chemray 800 delivers the reliability, accuracy, and throughput that clinical laboratories demand.

This device is intended for professional use in clinical laboratory settings by trained professionals. Not a substitute for professional medical diagnosis.

Key Features

⚡ High‑Throughput Performance – Up to 1200 T/H with ISE

The Chemray 800 delivers a constant throughput of 800 tests per hour (single and dual reagent) and up to 1,200 tests per hour when equipped with the integrated ISE (Ion‑Selective Electrode) module for electrolyte analysis (K⁺, Na⁺, Cl⁻). This high‑speed performance ensures efficient processing of routine and STAT workloads in busy laboratory environments.

🔬 Advanced Optical System with 12‑Wavelength Grating

The analyzer features a grating photometer system with 12 wavelengths (340, 405, 450, 505, 540, 570, 600, 635, 670, 700, 760, and 795 nm). This multi‑wavelength capability enables a wide range of clinical chemistry assays with high precision and accuracy.

📊 High‑Capacity Sample & Reagent Management

The Chemray 800 offers extensive capacity for high‑volume testing:



Component Capacity
Sample Tray 140 positions (inner 25 with 24‑hour non‑stop cooling)
Reagent Tray 128 positions, dual reagent tray design
Reaction Cuvettes 165 cuvettes with water bath temperature control

🧪 Flexible Reagent & Sample Handling

  • 2 reagent probes and 1 sample probe with collision protection, liquid level detection, and inventory checking,

  • 4 independent mixing stirrers for thorough homogenization,

  • Sample volume: 2‑45 µL (0.1 µL adjustable)

  • Reagent volume: 20‑350 µL (0.5 µL adjustable)

  • Support for R3 and R4 reagents – up to quadruple reagent chemistries

🧼 Low Carryover & Advanced Washing

The Chemray 800 features an 8‑step automatic washing system that ensures carryover ≤0.1%. This low carryover design minimizes cross‑contamination between samples, ensuring result integrity.

🔧 User‑Friendly Software & Connectivity

  • User‑friendly software with intuitive operation

  • Bi‑directional LIS interface (HL7) for seamless data exchange

  • Built‑in sample/reagent barcode scanners (optional),

🌡️ 24‑Hour Non‑Stop Refrigeration

The reagent tray and inner sample tray feature 24‑hour non‑stop cooling at 2‑10°C, ensuring reagent stability and integrity for continuous operation,.

⚙️ System Specifications



Feature Specification
Throughput 800 tests/hour (1200 with ISE)
Sample Capacity 140 positions
Reagent Capacity 128 positions
Reaction Cuvettes 165 positions
Methodologies End‑point, Two‑point, Kinetic
Wavelengths 12 wavelengths (340‑795 nm)
Absorbance Range 0‑3.500 Abs
Reaction Temperature 37°C ±0.2°C
Water Consumption ≤35 L/H
Dimensions (L×W×H) 1150 × 850 × 1250 mm
Power Supply AC100‑240V, 50/60Hz

What's Included

  • Chemray 800 Automatic Chemistry Analyzer Main Unit

  • 140‑Position Sample Tray (with 24h cooling)

  • 128‑Position Reagent Tray (dual reagent tray)

  • 165‑Position Reaction Cuvette Rotor

  • 12‑Wavelength Grating Photometer System

  • 2 Reagent Probes + 1 Sample Probe

  • 4 Independent Mixing Stirrers

  • 8‑Step Automatic Washing System

  • User‑Friendly Operation Software

  • Power Cable

  • User Manual

  • Installation and Training Support

Applications

The Chemray 800 Automatic Chemistry Analyzer is suitable for:

  • Clinical Laboratories – High‑volume routine biochemistry testing

  • Hospitals – Comprehensive patient diagnostics

  • Reference Laboratories – High‑throughput commercial testing

  • Research Institutions – Biochemical research and assay development

  • Public Health Laboratories – Screening and surveillance programs

Why Choose the Chemray 800?



Standard Chemistry Analyzers Global Healthcare Medical Chemray 800
Lower throughput 800 T/H (1200 with ISE) – high‑speed processing
Limited wavelengths 12‑wavelength grating system – broad assay capability
Limited sample capacity 140 sample positions – high‑volume testing
Limited reagent capacity 128 reagent positions – extensive menu flexibility
Higher carryover ≤0.1% carryover – 8‑step washing system
Limited probe redundancy 2 reagent probes + 1 sample probe – efficient workflow
Basic cooling 24‑hour non‑stop refrigeration – reagent stability

 

FAQ

Q: What is the Chemray 800 Automatic Chemistry Analyzer?

A: The Chemray 800 is a high‑throughput, random‑access automatic chemistry analyzer designed for clinical laboratory testing, featuring 800 tests/hour throughput (1200 with ISE) and a 12‑wavelength grating optical system.

Q: What is the throughput of the Chemray 800?

A: The Chemray 800 delivers a constant throughput of 800 tests per hour (single and dual reagent) and up to 1,200 tests per hour when equipped with the ISE module.

Q: What is the sample and reagent capacity?

A: The analyzer offers 140 sample positions (inner 25 with 24‑hour cooling) and 128 reagent positions with dual reagent tray design.

Q: What methodologies does the Chemray 800 support?

A: The analyzer supports end‑point, two‑point, and kinetic methodologies, with support for up to quadruple reagent chemistries.

Q: What wavelengths does the optical system cover?

A: The grating photometer system covers 12 wavelengths: 340, 405, 450, 505, 540, 570, 600, 635, 670, 700, 760, and 795 nm.

Q: Does the Chemray 800 have a cooling system for reagents?

A: Yes. The reagent tray and inner sample tray feature 24‑hour non‑stop cooling at 2‑10°C to ensure reagent stability.

Q: What is the carryover rate?

A: The Chemray 800 features an 8‑step automatic washing system with a carryover rate of ≤0.1%.

Q: Does the Chemray 800 support LIS connectivity?

A: Yes. The analyzer supports a bi‑directional LIS interface (HL7) for seamless data exchange.

Q: What is the power requirement?

A: The Chemray 800 operates on AC100‑240V, 50/60Hz.

Q: What are the dimensions of the Chemray 800?

A: The dimensions are 1150 mm (L) × 850 mm (W) × 1250 mm (H).