Comen NV8 Neonatal Ventilator

Comen NV8 Neonatal Ventilator

Regular price $7,979.00
Regular price Sale price $7,979.00
Sale Sold out
Free worldwide shipping. Shipping included in the price.

The Comen NV8 is a dedicated non-invasive neonatal ventilator engineered for newborns, premature infants, and low-birth-weight babies, including those weighing as little as 500 g. It brings together NCPAP, NIPPV, SNIPPV (with backup ventilation), and HFNC modes in a single device, with Peak Inspiratory Pressure (PIP) reaching up to 20 cmH₂O—a pressure range designed to support non-invasive respiratory care while reducing reliance on tracheal intubation.

The NV8’s iFlow intelligent closed-loop control system continuously monitors airway pressure near the infant’s nose and compensates for gas leakage in real time, supporting stable pressure delivery even during high-flow ventilation. The abdominal respiratory sensor triggers apnea wake-up in NCPAP mode and supports SNIPPV synchronization accuracy exceeding 90% across 10 sensitivity levels, directly addressing the irregular breathing patterns common in premature infants.

The device is built around an 8-inch LED touchscreen with a 15° tilt for ergonomic viewing, and includes dual-CPU monitoring, a 360° visible alarm light, and an intelligent warning system with double confirmation for key parameter settings. A built-in lithium battery provides up to 4 hours of operation during power interruption or intra-hospital transport, and the unit is mounted on an aluminum alloy trolley designed to reduce noise and enhance mobility.

For monitoring, the NV8 supports SpO₂ via Masimo or Nellcor modules and includes online oxygen concentration calibration that operates without interrupting ventilation. The device is compatible with NV Flow / Neo.Flow pressure generators as standard, and also accepts Infant Flow, Infant Flow LP, and Medijet generators to match existing departmental setups.

Regulatory status: The NV8 holds China NMPA registration (国械注准20163541772) as a Class III medical device, valid through January 21, 2026. Comen’s quality management system for neonatal and pediatric ventilators is certified under EU MDR 2017/745 Annex IX by SGS FIMKO (Notified Body 0598), Certificate FI23/1008002, valid from December 23, 2025 to September 5, 2028. No FDA 510(k) clearance specific to the NV8 was identified in the public FDA database during preparation of this page. Availability and cleared claims vary by market; confirm local registration and labeling before purchase.

The NV8 is built for neonatal intensive care units, special care nurseries, and delivery rooms that need a dedicated non-invasive ventilation platform for fragile patients—with the pressure performance, synchronization technology, and transport capability that preterm respiratory support demands.

Key Features & Benefits

Four Non-Invasive Modes in One Device: NCPAP, NIPPV, SNIPPV, and HFNC

The NV8 integrates Nasal Continuous Positive Airway Pressure (NCPAP) , Nasal Intermittent Positive Pressure Ventilation (NIPPV) , Synchronized Nasal Intermittent Positive Pressure Ventilation (SNIPPV) with backup ventilation, and High-Flow Nasal Cannula (HFNC) therapy in a single unit. This mode breadth allows a single device to support a neonatal patient from initial non-invasive support through weaning, without requiring separate machines for each modality. The SNIPPV mode includes backup ventilation, and HFNC includes pressure monitoring—configurations intended to support continuity of care as the infant’s respiratory status evolves.

PIP up to 20 cmH₂O with iFlow Closed-Loop Pressure Control

The NV8 delivers Peak Inspiratory Pressure up to 20 cmH₂O, a pressure ceiling positioned to support effective non-invasive ventilation in newborns without escalating to invasive support. The iFlow closed-loop control system uses proximal pressure monitoring near the infant’s nose, feeding data back to the CPU for real-time pressure adjustment and leak compensation—supporting stable pressure delivery even when circuit leakage is present or during high-flow ventilation. The device also includes automatic leakage compensation as a standard function.

Abdominal Respiratory Sensor with Apnea Wake-Up and >90% Synchronization

Premature infants frequently exhibit irregular abdominal breathing and apnea. The NV8 addresses this with an abdominal respiratory sensor that monitors breathing patterns and triggers an apnea wake-up function in NCPAP mode—delivering a strong airflow during detected apnea events. In SNIPPV mode, the sensor supports synchronization with 10 sensitivity levels, achieving breathing synchronization accuracy exceeding 90% according to Comen. This combination is intended to reduce the incidence of apnea and support patient-ventilator synchrony in spontaneously breathing infants.

8-Inch Touchscreen with 15° Tilt and Dual-CPU Monitoring

The 8-inch LED touchscreen is mounted at a 15° tilt for ergonomic viewing from beside the incubator, with a wide viewing angle intended to support quick parameter checks during rounds. The dual-CPU monitoring architecture provides a secondary processing path for enhanced operational reliability, and the intelligent warning system requires double confirmation when setting key parameters to reduce setting errors. A 360° visible alarm light supports awareness from across the NICU.

Up to 4 Hours of Battery for Transport and Power Interruption

The built-in lithium battery provides up to 4 hours of operation, supporting intra-hospital transport and continuity during power failure without interrupting ventilation. The aluminum alloy trolley is designed for mobility and reduced noise during movement between departments. The NV8 is cleared for use in medical institutions and intra-hospital transport under its China registration.

Broad Pressure Generator Compatibility: NV Flow, Neo.Flow, Infant Flow, Medijet

The NV8 ships standard with NV Flow / Neo.Flow pressure generators, designed for comfort and sealing performance in neonatal interfaces. It is also compatible with Infant Flow, Infant Flow LP, and Medijet generators, allowing departments that have standardized on a particular pressure generator to adopt the NV8 without changing their consumable ecosystem. The device includes multi-size soft silicone nasal plugs, masks, and cotton bonnets suitable for premature infants as small as 500 g.

SpO₂ Monitoring and Online Oxygen Calibration Without Interruption

The NV8 supports SpO₂ monitoring via Masimo or Nellcor modules, providing clinicians with blood oxygen data to assess the effectiveness of non-invasive support. The online oxygen concentration calibration circuit allows the oxygen cell to be calibrated while the NV8 continues ventilating—removing the need to interrupt therapy for routine calibration.

Technical Specifications



Specification Detail
Device Type Dedicated non-invasive neonatal ventilator
Intended Population Newborns, premature infants, and low-birth-weight infants (compatible with infants as small as 500 g)
Ventilation Modes NCPAP; NIPPV; SNIPPV (with backup ventilation); HFNC (with pressure monitoring)
Peak Inspiratory Pressure (PIP) Up to 20 cmH₂O
PEEP Range 1–13 cmH₂O (distributor documentation); clinical study settings referenced at 4–8 cmH₂O
Apnea Wake-Up Pressure 3–20 cmH₂O (distributor documentation)
Apnea Interval OFF; 1 s–30 s (distributor documentation)
Inspiratory Time 0.1–15 s (distributor documentation)
Respiratory Rate 1–120 bpm (distributor documentation)
FiO₂ 21%–100% (±3%), continuously adjustable
HFNC Flow Range 0.5–25 L/min (distributor documentation)
Manual Ventilation Time 1–30 s adjustable; airway pressure 2–25 cmH₂O; flow 2.0–30 L/min
Quick Oxygen Boost Up to 120 s; concentration 22%–100% continuously adjustable
Display 8-inch LED touchscreen; 15° tilt
Pressure Control iFlow closed-loop system with proximal pressure monitoring and leak compensation
Synchronization Abdominal respiratory sensor; 10 sensitivity levels; >90% SNIPPV synchronization accuracy
SpO₂ Monitoring Masimo or Nellcor module compatible
Oxygen Calibration Online calibration without interrupting ventilation
Battery Built-in lithium battery; up to 4 hours operation
Monitoring Architecture Dual-CPU
Alarm System 360° visible alarm light; intelligent double-confirmation for key parameter settings
Pressure Generator Compatibility NV Flow / Neo.Flow (standard); Infant Flow; Infant Flow LP; Medijet
Trolley Aluminum alloy construction for reduced noise and mobility
Data Features Log function; trend graphs and tables; storage and export (distributor documentation)
Regulatory Status China NMPA Class III: 国械注准20163541772 (valid through 2026-01-21); EU MDR 2017/745 QMS Certificate FI23/1008002 (SGS FIMKO, NB 0598, valid 2025-12-23 to 2028-09-05); no FDA 510(k) specific to NV8 identified; availability and cleared claims vary by market

Why Choose the Comen NV8?



Clinical or Operational Challenge NV8 Solution
Need a dedicated non-invasive neonatal platform with multiple modes NCPAP, NIPPV, SNIPPV (with backup), and HFNC in one device; PIP up to 20 cmH₂O
Need stable pressure despite circuit leaks in tiny patients iFlow closed-loop control with proximal pressure monitoring and real-time leak compensation
Premature infants with irregular breathing and apnea risk Abdominal respiratory sensor; apnea wake-up in NCPAP; SNIPPV synchronization >90% with 10 sensitivity levels
Need transport capability within the hospital Built-in battery up to 4 hours; aluminum trolley; cleared for intra-hospital transport
Need compatibility with existing pressure generators NV Flow / Neo.Flow standard; also accepts Infant Flow, Infant Flow LP, and Medijet
Need to support the smallest premature infants Compatible with infants as small as 500 g; multi-size soft silicone nasal interfaces
Need SpO₂ and oxygen calibration without interrupting therapy Masimo/Nellcor SpO₂; online oxygen calibration during ventilation
Need clear regulatory documentation for procurement China NMPA Class III registration; EU MDR QMS certificate from SGS FIMKO
View full details