EDAN CX10 Patient Monitor
EDAN CX10 Patient Monitor
The EDAN CX10 is the 10.1-inch entry point into EDAN's CX series of multi-parameter patient monitors—a bedside and in-hospital transport solution sharing the same monitoring platform as the larger CX12 (13.3-inch) and CX15 (15.6-inch) models. Where the CX10 differs is its compact 10.1-inch enclosure, making it suitable for general wards, sub-acute units, and transport scenarios where space and portability are practical constraints.
Standard parameters on the CX10 include 3/5-lead ECG, RESP, EDAN SpO₂, EDAN NIBP, PR, and 1-channel TEMP, running on EDAN's iSEAP™ ECG, iFAST™ NIBP, iCUFS™ NIBP, and iMAT™ SpO₂ algorithms. The 10.1-inch touchscreen (1024 × 600) supports gesture operation, supplemented by a rotary knob and physical buttons for alternative control. A fanless cooling design reduces power consumption and dust accumulation, and the enclosure is compatible with up to 31 common medical disinfectants for routine wipe-down between patients.
For expansion, the CX10 accepts optional 6/12-lead ECG, 2-channel TEMP, EDAN G2 sidestream CO₂ (with iCARB™ algorithm), cardiac output (C.O.), a thermal printer, and built-in Wi-Fi—parameters that move the device beyond basic vital-signs monitoring into procedure and higher-acuity support. Data management covers 1,200 NIBP records, 48 hours of 1-second trend data (or 240 hours at 1-minute resolution), 1,000 alarm events, and 48 hours of full-disclosure waveforms, with Wi-Fi, HDMI, and a multifunction interface for connectivity.
The CX10 is built for departments that need a common monitoring platform across different acuity levels: the same algorithms and interface logic as the CX12 and CX15, in the smallest enclosure in the CX series.
Key Features & Benefits
10.1-Inch Touchscreen with Rotary Knob for Alternative Control
The 10.1-inch color TFT touchscreen (1024 × 600) supports intuitive gesture operation for parameter selection and menu navigation. A rotary knob provides an alternative physical control, allowing operation when touch interaction is not practical. Large font, trend, OxyCRG, and full ECG display modes let the clinical team prioritize numerics, waveforms, or historical data depending on the task at hand.
No-Fan Design for Hygiene and Low Maintenance
The fanless architecture eliminates operating noise and prevents dust from accumulating on internal fan blades and grilles. This supports lower power consumption and reduced dust-related maintenance needs—advantages in wards and isolation areas where dust and noise are operational concerns. The enclosure is rated for compatibility with up to 31 common disinfectants, supporting routine wipe-down protocols between patients.
iSEAP™ ECG: Up to 33 Arrhythmia Types with SEMIP™ Analysis
The iSEAP™ ECG algorithm detects up to 33 arrhythmia types and incorporates SEMIP™ analysis for ECG evaluation. Multi-level analysis is designed to improve cardiac sensitivity while reducing false alarms, supporting clinician trust in the displayed measurements. The monitor supports standard 3/5-lead ECG with optional 6/12-lead for expanded cardiac evaluation.
iFAST™ NIBP: Rapid Measurement in Approximately 15 Seconds
The iFAST™ algorithm is designed to complete blood pressure measurement in approximately 15 seconds, reducing cuff inflation time during routine rounds. The iCUFS™ algorithm manages smart adaptive cuff inflation and deflation with cuff size identification, and is intended for adult, pediatric, and neonatal patients. A maintenance mode supports routine NIBP calibration and cleaning.
iMAT™ SpO₂: Motion and Low-Perfusion Performance
EDAN's iMAT™ SpO₂ algorithm is designed for motion resistance and low-perfusion performance, with a Perfusion Index (PI) reference reading that reflects perfusion changes at the sensor site. The CX10 supports simultaneous SpO₂ and NIBP measurement on the same limb, which can simplify setup in patients with limited access sites.
Optional EDAN G2 Sidestream CO₂ with iCARB™
When configured with the EDAN G2 CO₂ module, the CX10 adds sidestream capnography with the iCARB™ algorithm for intelligent CO₂ pseudo-wave identification, a superior water trap design, and a sampling rate as low as 50 mL/min. This makes the CX10 suitable for procedural sedation and anesthesia support where EtCO₂ trends are part of the monitoring workflow.
Expandable to IBP and Cardiac Output
The CX10 supports optional 2-channel IBP and cardiac output (C.O.) , allowing the same device to serve higher-acuity patients when hemodynamic monitoring is required. This expansion path is shared across the CX series, so departments can standardize on one interface and accessory ecosystem from ward to higher-acuity areas.
Data Review, Storage, and Connectivity
The CX10 stores 1,200 NIBP records, 48 hours of 1-second trend data (or 240 hours at 1-minute resolution), 1,000 alarm events, and 48 hours of full-disclosure waveforms. Wi-Fi (2.4/5 GHz), HDMI, and a multifunction interface support integration with central monitoring stations and hospital networks, while the optional thermal printer provides hard-copy documentation.
Technical Specifications
Why Choose the EDAN CX10?
| Clinical Challenge | CX10 Solution |
|---|---|
| Need a monitoring platform that scales across departments | Same algorithms and interface as CX12/CX15, in the smallest 10.1-inch CX enclosure |
| Touch-only interfaces can slow interaction in some workflows | Touchscreen + rotary knob for alternative control |
| Frequent cleaning between patients | No-fan design; enclosure compatible with up to 31 disinfectants |
| Routine NIBP rounds take time | iFAST™ algorithm designed to complete measurement in approximately 15 seconds |
| Motion and low perfusion compromise SpO₂ | iMAT™ algorithm with motion and low-perfusion resistance, plus PI reference |
| Need to add capnography without replacing the monitor | EDAN G2 sidestream CO₂ with iCARB™ and ~50 mL/min sampling rate |
| Need hemodynamic monitoring for higher-acuity patients | Optional 2-channel IBP and cardiac output (C.O.) |
| Procedure review without a separate PC | 48 h full disclosure, 1,200 NIBP, 1,000 alarms stored on-board; Wi-Fi/HDMI connectivity |