WhatsApp USA: +1 6032769350 | WhatsApp HK: +852 63697831
Global Healthcare Medical
EDAN H60 5‑Part Hematology Analyzer
EDAN H60 5‑Part Hematology Analyzer
The EDAN H60 is a fully automated 5‑part differential hematology analyzer engineered for low‑ to moderate‑volume clinical laboratories. Combining tri‑angle laser flow cytometry for white blood cell differentiation with electrical impedance for red blood cell and platelet counting, this benchtop system delivers a comprehensive 33‑parameter complete blood count (CBC) including NRBC, NLR, and PLR—all with exceptional accuracy and minimal operator intervention.
Designed around an Android‑based operating system with a 12.1‑inch color touchscreen, the H60 offers the intuitive feel of a smartphone while providing the clinical rigor expected from a professional hematology platform. Whether you run a small veterinary clinic, a mid‑sized hospital lab, or a reference laboratory, the H60 adapts to your workflow with three sampling modes (whole blood, capillary whole blood, and pre‑diluted) and a throughput of 60 samples per hour.
Key Features & Benefits
5‑Part Differential with 33 Parameters
The H60 delivers 25 reportable parameters plus 8 research parameters—far beyond what 3‑part analyzers can offer. The 5‑part differential provides individual counts and percentages for:
-
Neutrophils (NEU%) – key indicator of bacterial infection
-
Lymphocytes (LYM%) – essential for viral infection and immune status
-
Monocytes (MON%) – elevated in chronic inflammation and certain infections
-
Eosinophils (EOS%) – critical for allergy and parasitic infection detection
-
Basophils (BAS%) – rare but valuable for allergic reactions and myeloproliferative disorders
Additional advanced parameters include NRBC%, NRBC# (nucleated red blood cells), ALY%, ALY# (atypical lymphocytes), LIC%, LIC# (large immature cells), NLR, and PLR—providing deeper insights into hematological conditions.
Advanced Flagging System for Clinical Confidence
Sensitive flagging alerts you to abnormal results that may require manual slide review. This intelligent system reduces the risk of missing critical findings while helping you prioritize workflow—especially valuable in high‑volume settings where efficiency is paramount.
Triple‑Laser Flow Cytometry Technology
The H60 employs tri‑angle laser flow cytometry for WBC differential and BASO counting, combined with electrical impedance for RBC and PLT counting, and a cyanide‑free colorimetric method for hemoglobin measurement. This multi‑technology approach ensures:
-
Accurate cell classification even in challenging samples
-
Reliable platelet counting with anti‑interference technology
-
Wide linearity ranges for abnormal clinical cases
| Parameter | Linearity Range | Precision (CV%) |
|---|---|---|
| WBC | 0.0 – 500.0 × 10⁹/L | ≤ 3.0% (3.50–7.00) / ≤ 2.5% (7.01–15.00) |
| RBC | 0.0 – 8.5 × 10⁹/L | ≤ 1.5% (3.5–6.5) |
| HGB | 0 – 250 g/L | ≤ 1.5% (100–180) |
| PLT | 0 – 4000 × 10⁹/L | ≤ 5.0% (100–500) |
| MCV | 70 – 120 fL | ≤ 1.0% |
Visual Data Interpretation
The H60 provides 1 three‑dimensional scattergram (DIFF) and 4 two‑dimensional scattergrams (DIFF, BASO), plus 3 histograms for WBC, RBC, and PLT. These graphical representations allow you to quickly visualize cell populations and identify abnormalities at a glance—reducing time spent on data interpretation.
Android‑Based OS – Smartphone Simplicity
The Android‑based operating system delivers a user experience that feels natural and responsive. The 12.1‑inch color touchscreen displays all parameters and graphs on a single page, and you can access any function within two taps. The intuitive interface minimizes training time and reduces operator errors—allowing your team to focus on patient care rather than instrument operation.
Flexible Connectivity & Data Management
-
100,000 result storage including histograms and scattergrams
-
60 QC files (100 data per file)
-
Bi‑directional LIS/HIS connectivity with standardized HL7 protocol
-
Flexible printing options – individual results, control tests, L‑J graphs, or QC lists with selectable parameters
Smart Reagent Management with RFID
Each reagent is equipped with an RFID card that regulates usage and provides full traceability. This intelligent system:
-
Prevents reagent errors
-
Tracks consumption in real time
-
Secures your reagent business model
-
Reduces operating costs through optimized inventory management
Low Sample Volume – 16 µL
With a sample aspiration volume of just 16 µL (whole blood and capillary modes) and 20 µL for pre‑diluted mode, the H60 is ideal for:
-
Pediatric and neonatal patients
-
Small animal veterinary applications
-
Critical care settings with limited blood availability
-
Serial monitoring in patients where blood conservation is important
Low Maintenance – Maximum Uptime
The H60 is engineered for long product life with minimal maintenance requirements. The system automatically reminds you when service is due, ensuring consistent performance and reducing unplanned downtime.
Technical Specifications
| Specification | Detail |
|---|---|
| Measurement Principles | Tri‑angle laser flow cytometry (WBC DIFF & BASO); Electrical impedance (RBC & PLT); Cyanide‑free colorimetric (HGB) |
| Parameters | 25 reportable + 8 research = 33 total |
| Histograms | WBC, RBC, PLT |
| Scattergrams | 1× 3D (DIFF) + 4× 2D (DIFF, BASO) |
| Throughput | 60 samples per hour |
| Sample Volume | 16 µL (whole blood / capillary) / 20 µL (pre‑diluted) |
| Sample Modes | Whole blood, Capillary whole blood, Pre‑diluted |
| Display | 12.1‑inch color touchscreen |
| Data Storage | 100,000 results + 60 QC files |
| Connectivity | Bi‑directional LIS/HIS, HL7 protocol |
| Reagents | HD600 Diluent (20L), HL600 Lyse (500mL/1L), HC310 Cleaner (50mL) |
| Power Supply | 100V – 240V, 50/60Hz |
| Operating Temperature | 15°C – 32°C |
| Operating Humidity | 30% RH – 85% RH |
| Air Pressure | 70 kPa – 106 kPa |
| Dimensions | 501(D) × 320(W) × 502.5(H) mm |
| Weight | 29.3 kg |
Why Choose the EDAN H60?
| Challenge | H60 Solution |
|---|---|
| Need for 5‑part differential | 5‑part WBC differential with 33 total parameters including NRBC, NLR, PLR |
| Abnormal cell detection | Sensitive flagging system + 3D/2D scattergrams for visual verification |
| High operating costs | RFID reagent management + low reagent consumption |
| Complex operation | Android‑based OS with 12.1″ touchscreen – smartphone‑like experience |
| Limited sample volume | Only 16 µL sample aspiration – ideal for pediatric and small animal use |
| Data management | 100,000‑result storage + bi‑directional LIS with HL7 |
| Maintenance burden | Automatic service reminders + long‑life design |
| Multi‑site consistency | Standardized performance across instruments |