The EDAN H80 is a 5‑part differential hematology analyzer designed for clinical laboratories that need high‑throughput CBC testing with advanced WBC differentiation. It uses semiconductor laser flow cytometry with tri‑angle light scatter to generate a 3D scattergram for WBC subpopulation analysis, alongside a dedicated basophil channel and numerical NRBC reporting to support review of complex or abnormal samples.
The H80 is positioned for laboratories that need 80 samples per hour, a 23 µL test volume, and a 12.1‑inch color touchscreen interface in a compact benchtop format. RFID reagent management tracks reagent identity and status, and the system is designed around three routine reagents with a two‑year shelf life and 90‑day on‑board stability—supporting efficient reagent logistics and routine operation.
The analyzer’s 3D scattergram presents cell clusters across low scatter (cell volume), middle scatter (cell complexity), and high scatter (cell granularity) axes, and can be rotated on screen to support visual review of each cluster. The dedicated BASO channel uses specific baths and channels to detect basophils, which are the least numerous WBC population and can be masked by other clusters in standard analysis. NRBC flagging and numerical reporting are intended to help avoid incorrectly elevated WBC and lymphocyte counts when nucleated red blood cells are present.
Regulatory status: The H80 is intended for in vitro diagnostic use in clinical laboratory settings. No independent peer‑reviewed clinical validation study specific to the H80 was identified in the public literature during preparation of this page. Availability, labeling, and cleared claims vary by market; confirm local registration and intended use before purchase.
Key Features & Benefits
Tri‑Angle Laser and 3D Scattergram for 5‑Part WBC Differentiation
The H80 uses semiconductor laser technology with three scatter angles to characterize WBC populations: low scatter (LS, <10°) reflects cell volume, middle scatter (MS, 10°–20°) reflects cell complexity, and high scatter (HS, >20°) reflects cell granularity. The resulting 3D scattergram separates LYM, MON, NEU, and EOS clusters and can be rotated on screen to support visual inspection of each population in both normal and abnormal samples.
Dedicated BASO Channel
Basophils are the least numerous WBC population and are easily masked by other cell clusters. The H80 includes dedicated baths and channels for basophil detection, with cell volume and cell complexity displayed on a specific basophil scattergram to support visual review of this low‑frequency population.
NRBC Reporting and Flagging
Nucleated red blood cells (NRBCs) are similar in size to lymphocytes, and undetected NRBCs can produce erroneously elevated WBC and lymphocyte counts. The H80 can report numerical NRBC results and flag NRBC presence, supporting review of samples where NRBC interference may be present.
Eosinophilia Performance with 3D Scattergram
Eosinophils can be elevated in certain clinical presentations, and in abnormal or aging samples they may be obscured by other normal cells. The H80 combines laser technology with 3D scattergram visualization, using MS and HS to observe cell contents, granularity, and nucleus, supporting eosinophil differentiation in high‑eosinophil samples.
80 Samples per Hour with 23 µL Test Volume
The H80 processes up to 80 samples per hour and requires a 23 µL test volume, supporting moderate‑to‑high throughput while conserving sample in pediatric, geriatric, and difficult‑draw patients.
12.1‑Inch Color Touchscreen with RFID Reagent Management
The 12.1‑inch color touchscreen provides an intuitive operation system for sample review, result display, and system settings. RFID card‑based reagent management tracks reagent identity and status, supporting regulated reagent use and reducing manual tracking.
Cost‑Effective Reagent System: Three Routine Reagents, 2‑Year Shelf Life, 90‑Day On‑Board Stability
The H80 is designed around three routine reagents, with a two‑year shelf life and 90‑day on‑board stability. This configuration is intended to minimize reagent handling frequency and support cost‑effective operation in routine clinical laboratories.
Compact Benchtop Format
The H80 is a benchtop analyzer with an integrated touchscreen and sample aspiration port, designed for laboratory bench spaces where a compact footprint and direct sample access are practical requirements.
Technical Specifications
| Specification | Detail |
|---|---|
| Device Type | 5‑part differential automated hematology analyzer |
| Reportable Parameters | 5‑part WBC differential plus CBC parameters |
| WBC Analysis | Semiconductor laser flow cytometry with tri‑angle light scatter (LS/MS/HS) and 3D scattergram |
| BASO Detection | Dedicated basophil baths and channels; specific basophil scattergram |
| NRBC | Numerical NRBC reporting and NRBC flagging |
| Eosinophilia | 3D scattergram‑assisted eosinophil differentiation using MS and HS |
| Throughput | 80 samples per hour |
| Sample Volume | 23 µL |
| Display | 12.1‑inch color touchscreen |
| Reagent Management | RFID card‑based reagent tracking |
| Reagent System | 3 routine reagents; 2‑year shelf life; 90‑day on‑board stability |
| Intended Use | In vitro diagnostic 5‑part CBC testing in clinical laboratory settings |
Reagent Pricing
The H80 reagent portfolio includes HL610 Lyse, HL620 Lyse, HD600 Diluent, and HC310/HC600 Cleaner. The table below lists the product description, pack configuration, and price per box as provided in the EDAN price documentation. Part numbers have been omitted in accordance with the requested format.
| Product | Pack Configuration | Price per Box (USD) |
|---|---|---|
| HL610 Lyse | 1000 mL × 4 | $720.00 |
| HL610 Lyse | 1000 mL × 1 | $180.00 |
| HL610 Lyse | 500 mL × 4 | $360.00 |
| HL610 Lyse | 500 mL × 1 | $90.00 |
| HD600 Diluent | 20 L × 1/box | $37.50 |
| HC310 Cleaner | 50 mL × 6 | $45.00 |
| HC600 Cleaner | 50 mL × 6 | $45.00 |
| HL620 Lyse | 500 mL × 4 | $360.00 |
| HL620 Lyse | 500 mL × 1 | $90.00 |
| HL620 Lyse | 1000 mL × 4 | $720.00 |
| HL620 Lyse | 1000 mL × 1 | $180.00 |
Why Choose the EDAN H80?
| Clinical or Operational Challenge | H80 Solution |
|---|---|
| Need 5‑part WBC differentiation with visual cluster review | Tri‑angle laser scatter and rotatable 3D scattergram for LYM, MON, NEU, and EOS |
| Need basophil detection in a routine CBC workflow | Dedicated BASO channel and basophil scattergram |
| Need to avoid NRBC interference in WBC counts | Numerical NRBC reporting and NRBC flagging |
| Need eosinophil differentiation in abnormal or aging samples | 3D scattergram with MS/HS visualization supporting eosinophil review |
| Need moderate‑to‑high throughput | 80 samples per hour |
| Need to conserve sample volume | 23 µL test volume |
| Need regulated reagent tracking and cost control | RFID reagent management; 3 routine reagents; 2‑year shelf life; 90‑day on‑board stability |
| Need an intuitive benchtop interface | 12.1‑inch color touchscreen |