The EDAN H80S is a high‑throughput, 5‑part differential hematology analyzer engineered to reduce laboratory workload through advanced laser‑based cell analysis, streamlined automation, and an intuitive user interface. With a throughput of 80 samples per hour, continuous loading of venous and capillary tubes, and tri‑angle semiconductor laser differentiation, the H80S delivers reliable, accurate results for both routine and complex samples.
The H80S features a dedicated BASO channel, NRBC flagging with quantification, and comprehensive 3D & 2D scattergram analysis. Its large 12.1‑inch color touchscreen with a user‑oriented interface ensures fast navigation and simplified workflow for routine operations. Cost‑effective reagents with two‑year shelf life and 90‑day onboard stability, combined with simplified maintenance, make the H80S a powerful solution for modern mid‑volume laboratories seeking efficiency and diagnostic confidence.
Key Features & Benefits
Tri‑Angle Semiconductor Laser Technology for Superior WBC Differentiation
The H80S utilizes tri‑angle semiconductor laser flow cytometry for WBC, DIFF, and BASO counting. Three different angle scatters reflect comprehensive information about cells:
-
Low scatter (LS, <10°) – reflects cell volume
-
Middle scatter (MS, 10°–20°) – reflects cell complexity
This three‑angle approach provides detailed information on cell size, complexity, and granularity, improving separation of WBC subpopulations and enhancing detection in abnormal or aging samples.
Dedicated BASO Channel for Accurate Basophil Counting
Basophils are the least numerous cells and are easily masked by other cell clusters, making them the most difficult to detect. The H80S features dedicated baths and channels to accurately detect basophils. Cell volume and cell complexity are obtained on the specific basophil scattergram, reducing masking from other cell clusters and ensuring accurate basophil counts.
NRBC Flagging with Quantification
Nucleated red blood cells (NRBCs) are similar in size to lymphocytes, often leading to misidentification and erroneous WBC and lymphocyte counts. The H80S automatically flags and quantifies NRBCs, preventing falsely elevated WBC and lymphocyte counts caused by undetected NRBCs.
High Eosinophilia Performance
Eosinophils are significantly elevated during bacterial or parasitic infections. Combined with laser technology and 3D scattergrams, the H80S can easily handle high eosinophilic samples. Laser scatter and 3D scattergrams allow precise differentiation of eosinophils, especially in samples with parasitic or bacterial infections.
3D & 2D Scattergram Analysis for Enhanced Visualization
The H80S provides 1 three‑dimensional scattergram (DIFF) and 4 two‑dimensional scattergrams (3× DIFF, 1× BASO). The rotating 3D scattergram facilitates observation of each cell cluster, making results more reliable for both normal and abnormal samples. In abnormal and aging samples, eosinophils are often obscured by other normal cells—by using MS in conjunction with HS to observe contents, granularities, and nuclei, the 3D scattergram can more accurately differentiate eosinophils.
High Throughput & Flexible Sampling
-
Sample Volume: 23 μL (whole blood / capillary), 20 μL (pre‑diluted)
-
Sample Modes: Whole blood, capillary whole blood, and pre‑diluted
-
Capillary tube loading and auto bionic mixing of micro‑volume samples
Intuitive Android‑Based Operating System
The H80S features a 12.1‑inch color touchscreen with a user‑oriented interface. Fast navigation and simplified workflow make routine operations efficient and effortless.
Cost‑Effective Reagents with Long Shelf Life
-
Three core reagents with two‑year shelf life and 90‑day onboard stability
-
RFID reagent authentication and tracking for secure reagent management
-
Reduces operational costs while maintaining analytical reliability
Simplified Maintenance
Comprehensive Parameters
The H80S delivers 25 reportable parameters and 9 research parameters:
| Category | Parameters |
|---|---|
| Reportable (25) | WBC, LYM%, LYM#, MON%, MON#, NEU%, NEU#, EOS%, EOS#, BAS%, BAS#, RBC, HGB, HCT, MCV, RDW‑CV, RDW‑SD, MCH, MCHC, PLT, MPV, PCT, PDW, P‑LCR, P‑LCC |
| Research (9) | ALY%, ALY#, LIC%, LIC#, NRBC%, NRBC#, NLR, PLR, MLR |
| Histograms | WBC, RBC, PLT |
| Scattergrams | 4× 2D (3× DIFF, 1× BASO) + 1× 3D (DIFF) |
Technical Specifications
Why Choose the EDAN H80S?
| Laboratory Challenge | H80S Solution |
|---|---|
| Accurate WBC differentiation | Tri‑angle semiconductor laser with 3‑angle scatter (volume, complexity, granularity) |
| Basophil detection | Dedicated BASO channel—the least numerous cells are accurately counted |
| NRBC interference | Automatic NRBC flagging with quantification—prevents false WBC/lymphocyte counts |
| High eosinophil samples | 3D scattergram + laser technology for precise eosinophil differentiation |
| High sample volume | 80 samples/hour with continuous loading—walk‑away operation |
| Complex operation | 12.1″ touchscreen with Android‑based, user‑oriented interface |
| Limited sample volume | Only 23 μL whole blood—ideal for pediatric and critical care |
| High operating costs | Three core reagents with 2‑year shelf life, 90‑day onboard stability, RFID management |
| Maintenance burden | Test‑quantity‑based reminders + automated micro‑mixing |
| Data management | 100,000‑result storage + bi‑directional LIS with HL7 |