The EDAN H90 is a compact, high-performance 6-part differential hematology analyzer designed for mid- to high-volume clinical laboratories that need fast throughput, precise CBC and differential analysis, and fully standardized workflows. Built on EDAN’s fluorescent 3D flow cytometry platform, it combines forward scatter, side scatter, and side fluorescence to assess cell size, morphology, and nucleic-acid content—supporting true 6-part WBC differentials that include immature granulocytes (IG) alongside the standard five populations.
The H90 is positioned for laboratories that need high analytical depth without a large footprint. It reports 39 parameters (including NRBC in every CD test without extra reagents or operator steps) and supports up to 100 tests per hour with sample volumes as low as 23 µL in whole-blood mode. The 12.1-inch color touchscreen runs an upgraded, intuitive interface, and RFID reagent management supports reagent authenticity and traceability. On-board storage holds up to 150,000 results with histograms.
The analyzer’s fluorescent 3D analysis enables enhanced flagging for left shift, atypical/abnormal lymphocytes, and blasts, supporting review of samples that may warrant closer visual attention. The platelet solution includes impedance-based PLT-I, optional optical fluorescent PLT-O, and AI-driven PLT-A Smart Computing to resolve interferences from RBC fragments, microcytes, or platelet clumps. Expanded RBC indices—including IRF, RHE, IPF, LFR/MFR/HFR retic fractions, and InR for malaria-related infected RBC detection—extend the platform into anemia, infection, and thrombopoiesis assessment.
Regulatory status: The H90 is intended for in vitro diagnostic use in clinical laboratory settings. No independent peer-reviewed clinical validation study specific to the H90 was identified in the public literature during preparation of this page. Availability, labeling, and cleared claims vary by market; confirm local registration and intended use before purchase.
Key Features & Benefits
True 6-Part Differential with Fluorescent 3D Flow Cytometry
The H90 uses fluorescent 3D flow cytometry combining forward scatter (FSC), side scatter (SSC), and side fluorescence (SFL) to assess cell size, morphology, and nucleic-acid content. This supports a true 6-part differential that includes immature granulocytes (IG) with full validation, alongside enhanced flagging for left shift, atypical/abnormal lymphocytes, and blasts.
Cost-Efficient NRBC Analysis in Every CD Test
The H90 reports NRBCs in every CD test with no additional steps, reagents, or operator intervention, and results do not require WBC correction. This simplifies routine workflows and supports review of samples where nucleated red blood cells may interfere with WBC counts.
Comprehensive Platelet Solution: PLT-I, PLT-O, and PLT-A
The H90 includes improved impedance-based PLT-I, optional optical fluorescent PLT-O, and AI-driven PLT-A Smart Computing. This combination is designed to resolve most interferences such as RBC fragments, microcytes, or platelet clumps, supporting low-count accuracy in samples where platelet measurement is challenging.
Expanded RBC Indices for Anemia and Infection Screening
The platform includes IRF for reticulocyte production, RHE for iron-incorporation assessment, IPF as an indicator of thrombopoiesis, LFR/MFR/HFR retic fractions for anemia evaluation, and InR for malaria-related infected RBC detection. These indices extend the H90 beyond routine CBC into anemia workup and infection-related screening.
Up to 100 Tests per Hour with Low Sample Volume
The H90 supports up to 100 tests per hour (CBC+DIFF throughput referenced as 70 samples/hour in some documentation) and sample volumes as low as 23 µL in whole-blood mode, alongside capillary and pre-diluted modes. Front-back sheath flow eliminates secondary dilution, improving counting accuracy and reducing clogging.
12.1-Inch Touchscreen with Intuitive Upgraded UI and RFID Reagent Security
The 12.1-inch color touchscreen runs an upgraded, user-oriented interface with customizable print formats and Barcode Entry QC for secure, simple QC sheet scanning. Single-use RFID ensures reagent authenticity and traceability, supporting a secure reagent business model.
39 Reportable Parameters, 71 Research Parameters, and 150,000-Result Storage
The H90 reports 39 parameters and 71 research parameters, with 3 histograms, 3 scattergrams, and 8 two-dimensional scatterplots. On-board storage holds up to 150,000 results with histograms, supporting retrospective review and data management.
Flexible Connectivity and Compact Footprint
The system includes 4 USB ports (for external printer, barcode scanner, mouse, keyboard), 1 LAN port, and HL7 protocol support for LIS integration. At 640 mm (W) × 660 mm (D) × 610 mm (H) and 61 kg, the H90 fits mid-volume laboratory benches while delivering high-end analytical capability.
Technical Specifications
| Specification | Detail |
|---|---|
| Device Type | 6-part differential automated hematology analyzer |
| Analysis Platform | Fluorescent 3D flow cytometry (FSC, SSC, SFL) |
| Differential | True 6-part including immature granulocytes (IG) |
| Reportable Parameters | 39 parameters; including NRBC, PLT-I/PLT-O/PLT-A, expanded RBC indices |
| Research Parameters | 71 research parameters |
| Graphical Displays | 3 histograms, 3 scattergrams, 8 two-dimensional scatterplots |
| Throughput | Up to 100 tests/hour (CBC+DIFF referenced as 70 samples/hour in some documentation) |
| Sample Volume | Whole blood: as low as 23 µL; Capillary: 20 µL; Pre-diluted: 20 µL |
| Display | 12.1-inch color touchscreen |
| Data Storage | Up to 150,000 results with histograms |
| Connectivity | 4 USB ports; 1 LAN port; HL7 protocol / LIS support |
| Reagent Management | Single-use RFID for authenticity and traceability |
| Dimensions | 640 mm (W) × 660 mm (D) × 610 mm (H) |
| Weight | 61 kg |
| Power Supply | 100–240 V, 50/60 Hz |
| Operating Environment | 10°C–32°C; 30%–85% RH; 70–106 kPa |
| Intended Use | In vitro diagnostic 6-part CBC testing in clinical laboratory settings |
Reagent Pricing
The H90 reagent portfolio includes lyse (HL90H, HL91D, HL92N), diluent (HD93R, HD600), dye (HF91D, HF93R, HF92N), and cleaners (HC310, HC600). The table below lists the product description, pack configuration, and price per box as provided in the EDAN price documentation. Part numbers have been omitted in accordance with the requested format.
| Product | Pack Configuration | Price per Box (USD) |
|---|---|---|
| HL90H Lyse | 500 mL × 4 | $135.00 |
| HL90H Lyse | 1000 mL × 4 | $270.00 |
| HL91D Lyse | 500 mL × 4 | $135.00 |
| HL91D Lyse | 1000 mL × 4 | $270.00 |
| HL92N Lyse | 500 mL × 4 | $120.00 |
| HL92N Lyse | 1000 mL × 4 | $240.00 |
| HD93R Diluent | 500 mL × 4 | $135.00 |
| HD93R Diluent | 1000 mL × 4 | $270.00 |
| HL90H Lyse | 500 mL × 1 | $33.75 |
| HL90H Lyse | 1000 mL × 1 | $67.50 |
| HL91D Lyse | 500 mL × 1 | $33.75 |
| HL91D Lyse | 1000 mL × 1 | $67.50 |
| HL92N Lyse | 500 mL × 1 | $30.00 |
| HL92N Lyse | 1000 mL × 1 | $60.00 |
| HD93R Diluent | 500 mL × 1 | $33.75 |
| HD93R Diluent | 1000 mL × 1 | $67.50 |
| HF91D Dye | 12 mL × 1 | $41.25 |
| HF91D Dye | 12 mL × 2 | $82.50 |
| HF91D Dye | 48 mL × 1 | $165.00 |
| HF91D Dye | 48 mL × 2 | $330.00 |
| HF93R Dye | 6 mL × 1 | $165.00 |
| HF93R Dye | 6 mL × 2 | $330.00 |
| HF93R Dye | 12 mL × 1 | $330.00 |
| HF93R Dye | 12 mL × 2 | $660.00 |
| HF92N Dye | 12 mL × 1 | $41.25 |
| HF92N Dye | 12 mL × 2 | $82.50 |
| HF92N Dye | 48 mL × 1 | $165.00 |
| HF92N Dye | 48 mL × 2 | $330.00 |
| HD600 Diluent | 20 L × 1/box | $37.50 |
| HC310 Cleaner | 50 mL × 6 | $45.00 |
| HC600 Cleaner | 50 mL × 6 | $45.00 |
Why Choose the EDAN H90?
| Clinical or Operational Challenge | H90 Solution |
|---|---|
| Need true 6-part differential including IG | Fluorescent 3D flow cytometry with FSC, SSC, SFL; validated IG and enhanced flagging for blasts, atypical lymphocytes, and left shift |
| Need NRBC results without extra cost or workflow steps | NRBC reported in every CD test; no additional reagents or operator correction |
| Need reliable platelet counts in interference-prone samples | PLT-I, optional PLT-O, and AI-driven PLT-A to resolve RBC fragments, microcytes, and clumps |
| Need anemia and infection-related RBC indices | IRF, RHE, IPF, LFR/MFR/HFR, InR for reticulocyte, iron, thrombopoiesis, and malaria-related assessment |
| Need high throughput with low sample volume | Up to 100 tests/hour; 23 µL whole blood; front-back sheath flow for accuracy |
| Need reagent traceability and QC workflow | Single-use RFID; Barcode Entry QC; upgraded UI |
| Need substantial on-board storage | 150,000 results with histograms |
| Need LIS integration and compact footprint | HL7/LIS support; 4 USB + 1 LAN; 640 × 660 × 610 mm; 61 kg |