WhatsApp USA: +1 6032769350 | WhatsApp HK: +852 63697831
Global Healthcare Medical
GHM ACA Anticardiolipin Antibody IgM ELISA Kit US – 96-Well Solid-Phase ELISA for Semi-Quantitative Determination of Anticardiolipin Antibody IgM in Serum & Plasma (96T/Kit)
GHM ACA Anticardiolipin Antibody IgM ELISA Kit US – 96-Well Solid-Phase ELISA for Semi-Quantitative Determination of Anticardiolipin Antibody IgM in Serum & Plasma (96T/Kit)
SKU: GHM ACA Anticardiolipin Antibody IgM ELISA Kit US
Brand: Global Healthcare Medical
Product Overview
Global Healthcare Medical GHM ACA Anticardiolipin Antibody IgM ELISA Kit US is a 96-well enzyme-linked immunosorbent assay (ELISA) designed for the semi-quantitative determination of immunoglobulin M (IgM)-class antibodies directed against cardiolipin in human serum and plasma specimens. Anticardiolipin antibodies (ACA, aCL) belong to the antiphospholipid antibody family and recognise cardiolipin, a diphosphatidylglycerol species that is an anionic phospholipid enriched in the inner mitochondrial membrane and also exposed on certain membrane surfaces. In solid-phase assays, anticardiolipin antibody binding frequently requires the plasma protein β2-glycoprotein I as a cofactor, so antigen-down formats effectively detect antibodies directed against cardiolipin–β2GPI complexes rather than against the phospholipid alone — a consideration that materially affects assay design and the interpretation of binding signals. The IgM class is a pentameric immunoglobulin in which five monomeric units are linked by disulfide bonds and a J chain, giving ten antigen-binding sites per molecule. Because of its high molecular mass, IgM is largely confined to the intravascular compartment; it is also the first isotype produced in a primary humoral response before class switching. IgM-class anticardiolipin reactivity is studied as one isotype component of antiphospholipid antibody profiles in immunological research. Measurement of anticardiolipin antibody IgM is used in research settings to characterise the early-phase humoral response to anionic phospholipid antigens, study immunoglobulin class distribution within antiphospholipid antibody families, and investigate autoantibody profiles in immunological research models.
The kit employs a solid-phase ELISA principle with cardiolipin antigen immobilized on the solid phase and enzyme-conjugated anti-human IgM detection antibodies in the liquid phase. Results are evaluated against a cut-off value established from the assay calibrators and are expressed in MPL units (IgM phospholipid units) referenced to the kit calibrators, yielding a semi-quantitative interpretation. The assay is configured for a 50 µL sample volume and a total incubation time of approximately 1.5–2.5 hours (depending on protocol configuration), with absorbance read at 450 nm using standard microplate ELISA equipment. The kit is supplied in a 96-test/box format with an 18-month shelf life.
Intended Use: For laboratory research use only. This product is not intended for use in diagnostic procedures, not for therapeutic use, and not for clinical decision-making. Results should be interpreted by qualified laboratory professionals in the context of research applications.
Key Features & Benefits
Solid-Phase ELISA for Anticardiolipin Antibody IgM Detection
The assay utilizes a solid-phase ELISA format in which cardiolipin antigen is immobilized on the 96-well microplate and enzyme-conjugated anti-human IgM detection antibodies are supplied in liquid phase. This configuration supports specific antibody capture and signal generation, enabling evaluation of IgM-class anticardiolipin reactivity in serum and plasma matrices. Because the detection conjugate is directed against the mu heavy chain of human IgM, the readout is restricted to the IgM isotype and does not report total anticardiolipin immunoglobulin content — an important distinction when IgM, IgG, and IgA classes are studied as separate analytes within an antiphospholipid antibody profile. The pentameric structure of IgM means each molecule presents multiple binding sites to the immobilized phospholipid antigen, which supports efficient capture in solid-phase formats. The anionic phospholipid coating requires careful blocking and stabilisation to preserve antigen accessibility across the shelf life of the plate.
|
Feature |
Benefit |
|
Solid-phase ELISA format |
Established principle for anticardiolipin antibody detection |
|
Anti-human IgM detection |
IgM-isotype specific readout, not total immunoglobulin |
|
Anionic phospholipid antigen coating |
Preserves cardiolipin antigen accessibility |
|
MPL unit reporting |
Isotype-appropriate unit convention for IgM anticardiolipin |
Performance Aligned with Published Anticardiolipin Antibody ELISA Benchmarks
Published performance data for ELISA-format anticardiolipin antibody assays report cut-off value based semi-quantitative evaluation, with results expressed in isotype-specific phospholipid units — MPL units for the IgM class — referenced to kit calibrators rather than to a mass-concentration standard. It is well documented in the literature that antiphospholipid antibody assays lack a common international calibrator, so absolute unit values obtained on different platforms are not directly interchangeable and cut-off definitions differ between referenced configurations; laboratory professionals should confirm the applicable calibrator and cut-off definitions against the kit documentation supplied with each lot. Precision data for antibody-class ELISA formats of this type generally indicate intra-assay CV values below 10% and inter-assay CV values below 15%. Sample volumes of 50 µL are used in this configuration, and absorbance is read at 450 nm. These reference benchmarks support dependable performance expectations for research-oriented anticardiolipin antibody IgM serology.
|
Feature |
Benefit |
|
Cut-off value based semi-quantitative readout (published benchmark) |
Standardised qualitative and semi-quantitative framework |
|
MPL unit reporting (published benchmark) |
Isotype-specific unit convention for IgM anticardiolipin |
|
Intra-assay CV <10%; inter-assay CV <15% (published benchmark) |
Repeatability and reproducibility suitable for laboratory use |
Standardized 96-Well Workflow with 50 µL Sample Volume
The assay is formatted for standard 96-well microplate processing with a 50 µL sample volume and a total incubation time of approximately 1.5–2.5 hours. Absorbance is measured at 450 nm, aligning with widely available ELISA readers and washers.
|
Feature |
Benefit |
|
96 tests/box |
Practical batch configuration for research workflows |
|
50 µL sample volume |
Standard ELISA sample requirement |
|
450 nm reading |
Compatible with common microplate spectrophotometers |
|
~1.5–2.5 hour total incubation |
Efficient turnaround for batch processing |
18-Month Shelf Life
Extended reagent stability supports inventory planning and reduces replacement frequency in laboratory settings.
|
Feature |
Benefit |
|
18-month shelf life |
Extended inventory stability |
|
Consistent batch supply |
Supports repeatable research workflows |
Kit Contents & Pricing (EXW US Dollar)
|
Product Description |
Package |
Shelf Life |
Price/Kit (USD) |
CPT (USD/Test) |
|
ACA Anticardiolipin Antibody IgM ELISA Kit |
96 Tests/Box |
18 Months |
$38.00 |
$0.3958 |
Cost per test: approximately $0.40, based on a 96-test kit configuration.
Product Specifications
|
Specification |
Detail |
|
Model / SKU |
GHM ACA Anticardiolipin Antibody IgM ELISA Kit US |
|
Product Type |
Enzyme-Linked Immunosorbent Assay (ELISA) Kit |
|
Intended Use |
Semi-quantitative determination of anticardiolipin antibody IgM in human serum or plasma; for laboratory research use only; not for use in diagnostic procedures; not for therapeutic use |
|
Assay Principle |
Solid-phase ELISA with anti-human IgM detection |
|
Target Analyte |
Anticardiolipin antibody, immunoglobulin M (IgM) class |
|
Immunoglobulin Class |
IgM (mu heavy chain specific; pentameric) |
|
Antigen |
Cardiolipin (diphosphatidylglycerol), anionic phospholipid |
|
Cofactor Consideration |
β2-glycoprotein I dependent binding in solid-phase formats |
|
Specimen Types |
Human serum, plasma |
|
Specimen Volume |
50 µL/well |
|
Package Size |
96 Tests/Box |
|
Shelf Life |
18 Months |
|
Reading Wavelength |
450 nm |
|
Total Incubation Time |
Approximately 1.5–2.5 hours (protocol-dependent) |
|
Precision (published benchmark) |
Intra-assay CV <10%; inter-assay CV <15% |
|
Result Interpretation |
Cut-off value based semi-quantitative readout (published benchmark) |
|
Calibration Format |
MPL units (IgM phospholipid units) referenced to kit calibrators; no common international calibrator |
|
Regulatory Status |
Manufactured under EN ISO 13485 certified quality management system |
Why Laboratories Choose Global Healthcare Medical
|
Consideration |
GHM ACA Anticardiolipin Antibody IgM ELISA Kit US |
|
Solid-phase ELISA with anti-human IgM detection |
IgM-isotype specific readout, not total immunoglobulin |
|
MPL unit convention |
Isotype-appropriate reporting for IgM anticardiolipin |
|
Isotype-specific panel capability |
Pairs with the IgG and IgA configurations for class comparison |
|
Performance aligned with published anticardiolipin ELISA benchmarks |
Cut-off value based; CV <10%/<15% |
|
Cost-effective research serology |
$0.3958 per test; $38.00 per 96-test kit |
|
18-month shelf life |
Extended inventory stability |
|
Standard 96-well format |
Compatible with routine ELISA equipment |
|
ISO 13485 certified |
Quality management system compliance |
About Global Healthcare Medical
Global Healthcare Medical connects clinical laboratories, research institutions, and blood screening centers with diagnostic reagents and analytical systems designed for reliable operation in demanding healthcare environments. The GHM ACA Anticardiolipin Antibody IgM ELISA Kit US is part of our professional ELISA reagent portfolio, developed to support standardized, reproducible laboratory workflows.
Our focus is on dependable analytical performance, clear documentation, and responsive support for professional laboratory operations.
