WhatsApp USA: +1 6032769350 | WhatsApp HK: +852 63697831
Global Healthcare Medical
GHM BHA-3000 US – Compact Open-System 3-Part Differential Automatic Hematology Analyzer with 21 Reportable Parameters, 60 T/H Throughput & Flexible Reagent Configuration
GHM BHA-3000 US – Compact Open-System 3-Part Differential Automatic Hematology Analyzer with 21 Reportable Parameters, 60 T/H Throughput & Flexible Reagent Configuration
SKU: GHM BHA-3000 US
Brand: Global Healthcare Medical
Global Healthcare Medical GHM BHA-3000 US is a compact, fully automated 3-part differential hematology analyzer engineered for clinics, small-to-mid-sized hospital laboratories, and satellite testing sites that require routine CBC capability without proportionally expanding bench space. The system delivers a throughput of up to 60 tests per hour using as little as 6–10 µL of venous whole blood or 20 µL of capillary blood in pre-dilution mode, making it suitable for both adult and pediatric populations where collection volume is a practical constraint.
The analyzer is configured for open-system reagent operation, giving laboratories the flexibility to select compatible diluent and lysing reagents according to procurement preferences and cost-management strategies, while still supporting the dedicated DIL-3 diluent and HR-1 lyser chemistry for validated performance. The measurement platform combines classical electrical impedance for cell counting with photoelectric colorimetry for hemoglobin determination, reporting 21 parameters across 3 histograms for routine blood picture assessment.
Intelligent floating threshold technology supports reliable WBC subpopulation classification under variable sample conditions, while linear fitting breaks the conventional 2 fL lower detection limit for platelet volume, improving platelet counting confidence in samples with small platelets or interfering debris. The optimized liquid system and no-residue fluid path design reduce reagent carryover between consecutive samples, contributing to a low failure rate and straightforward maintenance.
The system operates on an Android-based platform with a 10.1-inch resistive touch screen, supporting intuitive workflow navigation and on-board result review without the need for an external computer. RFID reagent information recognition streamlines reagent loading without manual parameter entry. With dimensions of 328 × 425 × 446 mm and a weight of 16 kg, the GHM BHA-3000 US fits into space-constrained clinical environments while delivering core hematology reporting capability.
Key Features & Benefits
Open-System Reagent Configuration – Flexible Consumable Sourcing
The GHM BHA-3000 US is configured for open-system reagent operation, allowing laboratories to use compatible diluent and lysing reagents selected according to local procurement requirements and cost-management strategies. This configuration supports both the dedicated DIL-3 / HR-1 chemistry and alternative compatible reagent formulations, giving facilities greater control over consumable sourcing without locking into a single supply channel.
| Feature | Benefit |
|---|---|
| Open-system reagent mode | Flexibility to source compatible diluent and lyser reagents |
| Dedicated DIL-3 / HR-1 chemistry | Validated reagent pair for consistent analytical performance |
| Two-reagent architecture | 1 Diluent + 1 Lyser + 1 Shutdown Solution for simplified onboard management |
| RFID reagent recognition | Automatic reagent information loading without manual entry |
3-Part WBC Differential with 21 Reportable Parameters and 3 Histograms
The analyzer provides a 3-part white blood cell differential (lymphocytes, intermediate cells, and neutrophils) alongside red blood cell, platelet, and hemoglobin parameters, delivering a 21-parameter reportable panel covering routine CBC requirements. Three histograms (WBC, RBC, and PLT) offer visual distribution profiles for result verification.
| Feature | Benefit |
|---|---|
| 3-part WBC differential | LYM, MXD, and NEU populations with absolute and percentage values |
| 21 reportable parameters | Comprehensive routine CBC panel |
| 3 histograms | Visual quality assessment for WBC, RBC, and PLT distributions |
| Abnormal sample alarm | Flags results requiring manual review |
Minimal Sample Volume – 6–10 µL Venous or 20 µL Capillary Blood
The analyzer requires only 6–10 µL of venous whole blood and 20 µL of capillary blood in pre-dilution mode, reducing collection burden for pediatric, geriatric, and difficult-draw patients while maintaining analytical performance.
| Feature | Benefit |
|---|---|
| 6–10 µL venous whole blood | Minimal collection volume for routine testing |
| 20 µL capillary pre-dilution mode | Suitable for fingerstick or heelstick specimens |
| Flexible micro-sampling | Supports adult and pediatric testing from the same platform |
Optimized Liquid System & No-Residue Fluid Path
The optimized liquid system is engineered for a limited failure rate and excellent maintainability. The no-residue fluid path minimizes carryover of hematology diluent or lysing reagent between samples, supporting consistent results across consecutive tests without frequent priming or flushing cycles.
| Feature | Benefit |
|---|---|
| No-residue fluid path | Reduced reagent carryover between samples |
| Optimized liquid system | Limited failure rate and simplified maintenance |
| Automatic maintenance | Automatic cleaning and maintenance of the liquid system at regular intervals |
Intelligent Floating Threshold & Linear Fitting for Platelet Accuracy
Intelligent floating threshold technology supports accurate WBC subpopulation classification under variable sample conditions. Linear fitting extends the platelet volume detection range, breaking the conventional 2 fL lower limit and enabling more reliable platelet counting in samples with small platelets or subcellular debris interference.
| Feature | Benefit |
|---|---|
| Intelligent floating threshold | Reliable WBC classification across sample variability |
| Linear fitting for PLT | Extended platelet volume detection range |
| Breakthrough 2 fL limit | Improved low-end platelet counting confidence |
Android Touchscreen Operation with RFID Reagent Recognition
The system runs on an Android operating system with a 10.1-inch resistive touch screen, supporting intuitive workflow navigation and high-definition color display without an external computer. RFID automatic reagent information reading eliminates manual parameter entry, reducing setup errors and streamlining reagent changes.
Compact Footprint – 328 × 425 × 446 mm, 16 kg
With dimensions of 328 mm (L) × 425 mm (W) × 446 mm (H) and a weight of 16 kg, the analyzer occupies minimal bench space, making it suitable for clinics, physician offices, and satellite laboratory settings where space is at a premium.
| Feature | Benefit |
|---|---|
| 328 × 425 × 446 mm | Space-efficient benchtop installation |
| 16 kg | Lightweight and easy to relocate |
| Compact 3-part differential platform | Full CBC reporting capability in a small footprint |
Reagent Menu & Pricing (EXW US Dollar)
The GHM BHA-3000 US operates with a two-reagent configuration (1 Diluent + 1 Lyser) and an optional shutdown solution for fluid-path maintenance. The following dedicated reagent options are available for validated performance; the open-system configuration also permits evaluation of compatible alternative reagents according to the user's validation protocol.
Reagents for BHA-3000
| Category | Product Name | Packing | EXW Price (USD/Bottle) |
|---|---|---|---|
| Diluent | DIL-3 | 20 L / Bottle | $30.00 |
| Diluent | DIL-3C (Concentrated) | 2 L / Bottle | $15.00 |
| Diluent | DIL-3C (Concentrated) | 5 L / Bottle | $37.50 |
| Lyser | HR-1 | 200 mL / Bottle | $21.00 |
| Lyser | HR-1 | 500 mL / Bottle | $31.50 |
| Shutdown Solution | — | 50 mL / Bottle | $13.50 |
Product Specifications
| Specification | Detail |
|---|---|
| Model / SKU | GHM BHA-3000 US |
| Product Type | Fully Automated 3-Part Differential Hematology Analyzer |
| Reagent Configuration | Open-system reagent mode; dedicated DIL-3 diluent and HR-1 lyser supported |
| Intended Use | Counting of red blood cells, white blood cells, and platelets; hemoglobin measurement by colorimetry; calculation of related blood cell parameters for professional in vitro diagnostic use |
| Differential | 3-part WBC differential (LYM, MXD, NEU) |
| Reportable Parameters | 21 (WBC, NEU#, MXD#, LYM#, NEU%, MXD%, LYM%, RBC, HGB, MCV, RDW-CV, MCHC, MCH, RDW-SD, HCT, PLT, MPV, PDW, PCT, P-LCR, P-LCC) |
| Histograms | 3 (WBC, RBC, PLT) |
| Throughput | Up to 60 T/H (double-channel test mode) |
| Sample Modes | Whole blood (venous/capillary), pre-dilution |
| Sample Volume | Venous blood: 6–10 µL; Capillary blood (pre-dilution): 20 µL |
| Measurement Principles | Electrical impedance method (cell counting); photoelectric colorimetry (hemoglobin) |
| Display | 10.1-inch resistive touch screen |
| Operating System | Android |
| Reagent Recognition | RFID automatic reagent information reading |
| Reagent Type | Two reagents: 1 Diluent + 1 Lyser; optional Shutdown Solution |
| Data Storage | 100,000 patient results |
| QC Methods | L-J QC, X-B QC |
| Abnormal Sample Alarm | Yes |
| Automatic Printing | Built-in printer |
| Dimensions | 328 mm (L) × 425 mm (W) × 446 mm (H) |
| Weight | 16 kg |
| Power Supply | 220 V~, 50 Hz |
| Operating Conditions | 18–30°C, ≤80% relative humidity, 75–106 kPa |
| Regulatory Status | Manufactured under EN ISO 13485 certified quality management system |
Why Clinics and Small Laboratories Choose Global Healthcare Medical
| Consideration | GHM BHA-3000 US |
|---|---|
| Open-system reagent flexibility | Source compatible diluent and lyser according to local requirements |
| Compact 3-part differential | 21-parameter CBC in a 328 × 425 × 446 mm footprint |
| Minimal sample volume | 6–10 µL venous / 20 µL capillary modes |
| Platelet accuracy | Linear fitting breaks the 2 fL detection limit |
| No-residue fluid path | Reduced carryover and simplified maintenance |
| RFID reagent recognition | Error-free reagent loading without manual scanning |
| Android touchscreen operation | Intuitive workflow with 10.1-inch display |
| ISO 13485 certified | Quality management system compliance |
About Global Healthcare Medical
Global Healthcare Medical connects clinical laboratories and diagnostic centers with high-performance analytical systems designed for reliable operation in demanding healthcare environments. The GHM BHA-3000 US is part of our professional hematology analyzer line, developed to support accurate, compact, and procurement-flexible blood analysis in clinics, physician offices, and small-to-mid-sized laboratory settings.
Our focus is on dependable analytical performance, clear documentation, and responsive support for professional clinical operations.