Skip to product information
1 of 1

Contact via WhatsApp: +81 9022195237

Global Healthcare Medical

GHM-CA10S Capnograph | Portable EtCO2 Monitor with SpO2 & Respiratory Rate #

GHM-CA10S Capnograph | Portable EtCO2 Monitor with SpO2 & Respiratory Rate #

Regular price $599.00
Regular price Sale price $599.00
Sale Sold out
Shipping calculated at checkout.

Portable sidestream capnograph with EtCO2, SpO2, PR, and respiration rate monitoring. Audible/visual alarms, 8-hour battery, and self-calibration. Ideal for ICU, ER, and respiratory care.

The Global Healthcare Medical GHM-CA10S Capnograph is a portable, handheld monitoring device designed for real‑time measurement of end‑tidal carbon dioxide (EtCO₂) , airway respiration rate (AwRR) , blood oxygen saturation (SpO₂) , and pulse rate (PR) . Using advanced sidestream sampling technology, the device draws a small sample of respiratory gas from the patient's nasal airway through a sampling tube, enabling continuous, non‑invasive monitoring of pulmonary ventilation and circulatory function.

With its compact size (159mm × 72mm × 31mm) and lightweight design (270g) , the GHM-CA10S is ideal for use in emergency departments, ICUs, operating rooms, respiratory departments, pre‑hospital emergency transfers, and neonatology.

This device is intended for use by healthcare professionals in clinical settings. It is not a substitute for professional medical diagnosis.

Key Features

🫁 Sidestream EtCO₂ & Respiration Rate Monitoring

The GHM-CA10S adopts sidestream sampling technology to continuously measure end‑tidal carbon dioxide (EtCO₂) and airway respiration rate (AwRR). This allows clinicians to:

  • Detect pulmonary ventilation function

  • Reflect circulation and pulmonary blood flow

  • Indirectly assess alveolar ventilation

EtCO₂ Specifications:

  • Measurement range: 0 – 150 mmHg

  • Resolution: 1 mmHg

Respiration Rate Specifications:

  • Measurement range: 2 – 120 rpm

🩸 Integrated SpO₂ & Pulse Rate Monitoring

In addition to capnography, the GHM-CA10S measures blood oxygen saturation (SpO₂) and pulse rate (PR) in a single, integrated device, providing comprehensive respiratory and hemodynamic assessment.

SpO₂ & PR Specifications (Human Use):

  • SpO₂ measurement range: 30 – 100%

  • Pulse rate range: 25 – 250 bpm

  • Resolution: 1 bpm

  • Accuracy: ±2 bpm or ±2%, whichever is greater

🚨 Audible & Visual Alarms with Adjustable Limits

Patient safety is paramount with the GHM-CA10S's comprehensive alarm system:

  • Audible and visual alarms with silencing function

  • Adjustable alarm limits for EtCO₂, respiration rate, SpO₂, and pulse rate

  • Over‑limit alarm for all parameters

  • Low battery alarm

  • "Checking Filterline" prompt to ensure proper sampling line function

🔬 Self‑Calibration & Environmental Compensation

The GHM-CA10S allows users to calibrate zero by themselves, ensuring measurement accuracy. It also features built‑in atmospheric pressure and temperature compensation functions, maintaining reliable performance across varying clinical environments.

🔋 Long‑Lasting Rechargeable Battery

Powered by a rechargeable lithium battery with up to 8 hours of continuous use, the GHM-CA10S ensures uninterrupted monitoring during transport, emergency procedures, and power outages.

📦 Compact, Portable & Ergonomic Design

  • Dimensions: 159mm × 72mm × 31mm

  • Weight: Approx. 270g

  • Handheld design – Easy to carry and operate

  • Sidestream sampling – Connects to the patient's nasal airway via a sampling tube (applied part)

🌍 Optional Unit Selection

The device supports three optional units for measurement display, accommodating different clinical preferences and regional standards.

Specifications



Feature Specification
Product Type Sidestream Capnograph / EtCO₂ Monitor
Model GHM-CA10S
Technology Sidestream sampling
EtCO₂ Range 0 – 150 mmHg
EtCO₂ Resolution 1 mmHg
Respiration Rate Range 2 – 120 rpm
SpO₂ Range 30 – 100%
Pulse Rate Range 25 – 250 bpm
Pulse Rate Resolution 1 bpm
Pulse Rate Accuracy ±2 bpm or ±2% (whichever is greater)
Alarm Types Audible, visual; adjustable limits; silencing function
Alarm Parameters EtCO₂, Respiration Rate, SpO₂, Pulse Rate, Low Battery
Special Functions Self‑calibration, atmospheric pressure & temperature compensation, "Checking Filterline" prompt, optional units
Power Supply Rechargeable lithium battery
Battery Life Up to 8 hours
Dimensions 159mm × 72mm × 31mm
Weight Approx. 270g
Intended Use Emergency departments, ICU, operating rooms, respiratory departments, pre‑hospital transfer, neonatology
Patient Population Adult patients

What's Included

  • GHM-CA10S Capnograph Main Unit

  • Sampling Tube (Applied Part)

  • SpO₂ Probe

  • Rechargeable Lithium Battery (built‑in)

  • USB Charging Cable

  • User Manual

Applications

The GHM-CA10S Capnograph is suitable for:

  • Emergency Departments (ER) – Rapid respiratory and hemodynamic assessment

  • Intensive Care Units (ICU) – Continuous monitoring of ventilated and non‑ventilated patients

  • Operating Rooms (OR) – Intraoperative monitoring of EtCO₂ and ventilation

  • Respiratory Departments – Pulmonary function assessment and monitoring

  • Pre‑Hospital Emergency Transfer – Portable monitoring during ambulance transport

  • Neonatology – Respiratory monitoring in neonatal care settings

  • Post‑Anesthesia Care Units (PACU) – Recovery monitoring

Why Choose the GHM-CA10S?



Basic Capnographs Global Healthcare Medical GHM-CA10S
EtCO₂ only EtCO₂ + AwRR + SpO₂ + PR – 4‑in‑1 monitoring
Fixed alarms Adjustable audible/visual alarms with silencing
Limited battery Up to 8‑hour rechargeable battery
Bulky design Compact (159×72×31mm), lightweight (270g)
No self‑calibration User‑initiated zero calibration
No environmental compensation Built‑in pressure & temperature compensation

FAQ

Q: What is the GHM-CA10S Capnograph?

A: The GHM-CA10S is a portable, handheld sidestream capnograph that measures end‑tidal carbon dioxide (EtCO₂), airway respiration rate (AwRR), blood oxygen saturation (SpO₂), and pulse rate (PR) in a single device.

Q: What is sidestream sampling technology?

A: Sidestream sampling draws a small sample of respiratory gas from the patient's nasal airway through a sampling tube for continuous analysis, enabling non‑invasive monitoring of ventilation and circulation.

Q: How long does the battery last?

A: The built‑in rechargeable lithium battery provides up to 8 hours of continuous use.

Q: Does the device have alarm functions?

A: Yes. The GHM-CA10S features audible and visual alarms with adjustable limits for EtCO₂, respiration rate, SpO₂, and pulse rate, as well as low battery and filterline check alerts.

Q: Can I calibrate the device myself?

A: Yes. Users can calibrate zero by themselves, ensuring ongoing measurement accuracy.

Q: What clinical settings is the device suitable for?

A: The GHM-CA10S is suitable for emergency departments, ICUs, operating rooms, respiratory departments, pre‑hospital emergency transfer, and neonatology.

Q: What patient population is the device intended for?

A: The GHM-CA10S is intended for adult patients.

Q: What is included in the package?

A: The package includes the GHM-CA10S main unit, sampling tube, SpO₂ probe, built‑in rechargeable battery, USB charging cable, and user manual.

View full details