Contact via WhatsApp: +81 9022195237
Global Healthcare Medical
GHM-CA20M Capnograph | Mainstream EtCO2 Monitor with SpO2 & 8‑Hour Battery #
GHM-CA20M Capnograph | Mainstream EtCO2 Monitor with SpO2 & 8‑Hour Battery #
Couldn't load pickup availability
Mainstream capnograph with EtCO2, respiration rate, SpO2, and pulse rate monitoring. Audible/visual alarms, self‑calibration, 8‑hour battery, and high‑altitude capability. Ideal for ICU, ED, OR, and respiratory care.
The Global Healthcare Medical GHM-CA20M Capnograph is a compact, handheld mainstream capnograph designed for continuous, real‑time monitoring of end‑tidal carbon dioxide (EtCO₂) , airway respiration rate (AwRR) , blood oxygen saturation (SpO₂) , and pulse rate (PR) in a single integrated device. Using advanced mainstream measurement technology, the device places the CO₂ sensor directly in the patient's breathing circuit via an airway adapter and breathing tube, providing accurate, real‑time measurements at the airway.
This versatile monitoring solution is applicable for adult, pediatric, and infant patients in emergency departments, ICUs, operating rooms, respiratory departments, and pre‑hospital emergency transfer. With its compact design, rechargeable battery providing up to 8 hours of continuous use, and comprehensive alarm system, the GHM-CA20M is an essential tool for clinicians managing ventilated and non‑ventilated patients alike.
This device is intended for use by healthcare professionals in clinical settings. It is not a substitute for professional medical diagnosis.
Key Features
🫁 Mainstream EtCO₂ & Respiration Rate Monitoring
The GHM-CA20M adopts mainstream measurement technology to continuously measure end‑tidal carbon dioxide (EtCO₂) and airway respiration rate (AwRR). This enables clinicians to:
-
Monitor pulmonary ventilation function
-
Assess circulation and pulmonary blood flow
-
Indirectly evaluate alveolar ventilation
EtCO₂ Specifications:
-
Measurement range: 0 – 150 mmHg
-
Resolution: 1 mmHg
-
Accuracy: 0–40 mmHg: ±2 mmHg; 41–70 mmHg: ±5% of readings; 71–100 mmHg: ±8% of readings; 101–150 mmHg: ±10% of readings
Respiration Rate Specifications:
-
Measurement range: 2 – 150 rpm
🩸 Integrated SpO₂ & Pulse Rate Monitoring
In addition to capnography, the GHM-CA20M measures blood oxygen saturation (SpO₂) and pulse rate (PR) in a single, integrated device, providing comprehensive respiratory and hemodynamic assessment without the need for separate monitors.
🚨 Comprehensive Audible & Visual Alarms
Patient safety is paramount with the GHM-CA20M's advanced alarm system:
-
Audible and visual alarms with silencing function
-
Adjustable alarm limits for all parameters
-
Over‑limit alarms for EtCO₂, respiration rate, SpO₂, and pulse rate
-
"Adapter off" prompt to ensure proper airway adapter connection
🔬 Self‑Calibration & Environmental Compensation
The GHM-CA20M allows users to calibrate the device independently, ensuring ongoing measurement accuracy. It also features built‑in atmospheric pressure and temperature compensation functions, maintaining reliable performance across varying clinical environments—including high altitude areas.
🔋 Long‑Lasting Rechargeable Battery
Powered by a rechargeable lithium battery, the GHM-CA20M provides up to 8 hours of continuous use, ensuring uninterrupted monitoring during transport, emergency procedures, and power outages. The device also features a low battery alarm to alert clinicians before power runs out.
💾 Data Storage & Transmission
The GHM-CA20M includes a reserved data storage and transmission function module, enabling future expansion for data management and integration with hospital information systems.
📦 Ultra‑Compact & Lightweight Design
-
Handheld design – Easy to carry and operate
-
Mainstream connection – Connects directly to the patient's breathing circuit via airway adapter and breathing tube
🌍 Optional Unit Selection
The device supports three optional units for measurement display, accommodating different clinical preferences and regional standards.
🛡️ Premium Safety Classifications
Specifications
What's Included
-
GHM-CA20M Capnograph Main Unit
-
Airway Adapter
-
Breathing Tube
-
Rechargeable Lithium Battery (built‑in)
-
User Manual
Optional Accessories
Applications
The GHM-CA20M Capnograph is suitable for:
-
Emergency Departments (ED) – Rapid respiratory and hemodynamic assessment
-
Intensive Care Units (ICU) – Continuous monitoring of ventilated and non‑ventilated patients
-
Operating Rooms (OR) – Intraoperative capnography during anesthesia
-
Respiratory Departments – Pulmonary function assessment and monitoring
-
Pre‑Hospital Emergency Transfer – Portable monitoring during ambulance transport
-
Neonatology – Respiratory monitoring in neonatal care (with optional neonate adapter)
-
High‑Altitude Environments – Accurate performance even in high altitude areas
Why Choose the GHM-CA20M?
| Basic Capnographs | Global Healthcare Medical GHM-CA20M |
|---|---|
| EtCO₂ only | EtCO₂ + AwRR + SpO₂ + PR – 4‑in‑1 monitoring |
| Fixed alarms | Adjustable audible/visual alarms with silencing |
| Limited battery | Up to 8‑hour rechargeable battery |
| Bulky design | Compact (159×72×31mm), lightweight (254g) |
| No self‑calibration | User‑initiated calibration |
| No environmental compensation | Built‑in pressure & temperature compensation |
| Standard use only | High‑altitude capable |
FAQ
Q: What is the GHM-CA20M Capnograph?
A: The GHM-CA20M is a handheld mainstream capnograph that measures end‑tidal carbon dioxide (EtCO₂), airway respiration rate (AwRR), blood oxygen saturation (SpO₂), and pulse rate (PR) in a single device.
Q: What is mainstream measurement technology?
A: Mainstream technology places the CO₂ sensor directly in the patient's breathing circuit via an airway adapter, providing real‑time, accurate EtCO₂ measurements at the airway.
Q: What patient populations is the device suitable for?
A: The GHM-CA20M is suitable for adult, pediatric, and infant patients.
Q: How long does the battery last?
A: The built‑in rechargeable lithium battery provides up to 8 hours of continuous use.
Q: Does the device have alarm functions?
A: Yes. The GHM-CA20M features audible and visual alarms with adjustable limits for EtCO₂, respiration rate, SpO₂, and pulse rate, plus low battery and adapter off alerts.
Q: Can I calibrate the device myself?
A: Yes. Users can calibrate the device independently to ensure ongoing measurement accuracy.
Q: Can the device be used in high‑altitude areas?
A: Yes. The GHM-CA20M features atmospheric pressure compensation and is designed to function accurately in high altitude environments.
Q: What clinical settings is the device suitable for?
A: The GHM-CA20M is suitable for emergency departments, ICUs, operating rooms, respiratory departments, and pre‑hospital emergency transfer.
Q: What is included in the package?
A: The package includes the GHM-CA20M main unit, airway adapter, breathing tube, built‑in rechargeable battery, and user manual.
Share