GHM-CA20M Capnograph | Mainstream EtCO2 Monitor with SpO2 & 8‑Hour Battery #

Mainstream capnograph with EtCO2, respiration rate, SpO2, and pulse rate monitoring. Audible/visual alarms, self‑calibration, 8‑hour battery, and high‑altitude capability. Ideal for ICU, ED, OR, and respiratory care.

The Global Healthcare Medical GHM-CA20M Capnograph is a compact, handheld mainstream capnograph designed for continuous, real‑time monitoring of end‑tidal carbon dioxide (EtCO₂) , airway respiration rate (AwRR) , blood oxygen saturation (SpO₂) , and pulse rate (PR) in a single integrated device. Using advanced mainstream measurement technology, the device places the CO₂ sensor directly in the patient's breathing circuit via an airway adapter and breathing tube, providing accurate, real‑time measurements at the airway.

This versatile monitoring solution is applicable for adult, pediatric, and infant patients in emergency departments, ICUs, operating rooms, respiratory departments, and pre‑hospital emergency transfer. With its compact design, rechargeable battery providing up to 8 hours of continuous use, and comprehensive alarm system, the GHM-CA20M is an essential tool for clinicians managing ventilated and non‑ventilated patients alike.

This device is intended for use by healthcare professionals in clinical settings. It is not a substitute for professional medical diagnosis.

Key Features

🫁 Mainstream EtCO₂ & Respiration Rate Monitoring

The GHM-CA20M adopts mainstream measurement technology to continuously measure end‑tidal carbon dioxide (EtCO₂) and airway respiration rate (AwRR). This enables clinicians to:

  • Monitor pulmonary ventilation function

  • Assess circulation and pulmonary blood flow

  • Indirectly evaluate alveolar ventilation

EtCO₂ Specifications:

  • Measurement range: 0 – 150 mmHg

  • Resolution: 1 mmHg

  • Accuracy: 0–40 mmHg: ±2 mmHg; 41–70 mmHg: ±5% of readings; 71–100 mmHg: ±8% of readings; 101–150 mmHg: ±10% of readings

Respiration Rate Specifications:

  • Measurement range: 2 – 150 rpm

🩸 Integrated SpO₂ & Pulse Rate Monitoring

In addition to capnography, the GHM-CA20M measures blood oxygen saturation (SpO₂) and pulse rate (PR) in a single, integrated device, providing comprehensive respiratory and hemodynamic assessment without the need for separate monitors.

🚨 Comprehensive Audible & Visual Alarms

Patient safety is paramount with the GHM-CA20M's advanced alarm system:

  • Audible and visual alarms with silencing function

  • Adjustable alarm limits for all parameters

  • Over‑limit alarms for EtCO₂, respiration rate, SpO₂, and pulse rate

  • Low battery alarm

  • "Adapter off" prompt to ensure proper airway adapter connection

🔬 Self‑Calibration & Environmental Compensation

The GHM-CA20M allows users to calibrate the device independently, ensuring ongoing measurement accuracy. It also features built‑in atmospheric pressure and temperature compensation functions, maintaining reliable performance across varying clinical environments—including high altitude areas.

🔋 Long‑Lasting Rechargeable Battery

Powered by a rechargeable lithium battery, the GHM-CA20M provides up to 8 hours of continuous use, ensuring uninterrupted monitoring during transport, emergency procedures, and power outages. The device also features a low battery alarm to alert clinicians before power runs out.

💾 Data Storage & Transmission

The GHM-CA20M includes a reserved data storage and transmission function module, enabling future expansion for data management and integration with hospital information systems.

📦 Ultra‑Compact & Lightweight Design

  • Dimensions: 159mm × 72mm × 31mm

  • Weight: Approx. 254g

  • Handheld design – Easy to carry and operate

  • Mainstream connection – Connects directly to the patient's breathing circuit via airway adapter and breathing tube

🌍 Optional Unit Selection

The device supports three optional units for measurement display, accommodating different clinical preferences and regional standards.

🛡️ Premium Safety Classifications

  • Degree of protection against ingress of liquid: IPX1

  • Degree of protection against electric shock: Defibrillation‑proof Type BF applied part

  • Operating temperature: 5°C – 40°C

  • Relative humidity: 30% – 75% (no condensation)

  • Atmospheric pressure: 700hPa – 1060hPa

Specifications



Feature Specification
Product Type Mainstream Capnograph / EtCO₂ Monitor
Model GHM-CA20M
Technology Mainstream measurement
EtCO₂ Range 0 – 150 mmHg
EtCO₂ Resolution 1 mmHg
EtCO₂ Accuracy 0–40 mmHg: ±2 mmHg; 41–70 mmHg: ±5%; 71–100 mmHg: ±8%; 101–150 mmHg: ±10%
Respiration Rate Range 2 – 150 rpm
SpO₂ Integrated monitoring
Pulse Rate Integrated monitoring
Alarm Types Audible, visual; silencing function; adjustable limits
Alarm Parameters EtCO₂, respiration rate, SpO₂, pulse rate, low battery, adapter off
Special Functions Self‑calibration, atmospheric pressure & temperature compensation, optional units, high‑altitude capability
Power Supply Rechargeable lithium battery
Battery Life Up to 8 hours
Data Storage Reserved module for storage and transmission
Dimensions 159mm × 72mm × 31mm
Weight Approx. 254g
Waterproof Rating IPX1
Safety Classification Defibrillation‑proof Type BF applied part
Operating Temperature 5°C – 40°C
Relative Humidity 30% – 75% (no condensation)
Atmospheric Pressure 700hPa – 1060hPa
Intended Use Emergency department, ICU, operating room, respiratory department, pre‑hospital transfer
Patient Population Adult, pediatric, infant

What's Included

  • GHM-CA20M Capnograph Main Unit

  • Airway Adapter

  • Breathing Tube

  • Rechargeable Lithium Battery (built‑in)

  • User Manual

Optional Accessories

  • SpO₂ Probe (optional)

  • Neonate Airway Adapter

  • Data Cable

Applications

The GHM-CA20M Capnograph is suitable for:

  • Emergency Departments (ED) – Rapid respiratory and hemodynamic assessment

  • Intensive Care Units (ICU) – Continuous monitoring of ventilated and non‑ventilated patients

  • Operating Rooms (OR) – Intraoperative capnography during anesthesia

  • Respiratory Departments – Pulmonary function assessment and monitoring

  • Pre‑Hospital Emergency Transfer – Portable monitoring during ambulance transport

  • Neonatology – Respiratory monitoring in neonatal care (with optional neonate adapter)

  • High‑Altitude Environments – Accurate performance even in high altitude areas

Why Choose the GHM-CA20M?



Basic Capnographs Global Healthcare Medical GHM-CA20M
EtCO₂ only EtCO₂ + AwRR + SpO₂ + PR – 4‑in‑1 monitoring
Fixed alarms Adjustable audible/visual alarms with silencing
Limited battery Up to 8‑hour rechargeable battery
Bulky design Compact (159×72×31mm), lightweight (254g)
No self‑calibration User‑initiated calibration
No environmental compensation Built‑in pressure & temperature compensation
Standard use only High‑altitude capable

FAQ

Q: What is the GHM-CA20M Capnograph?

A: The GHM-CA20M is a handheld mainstream capnograph that measures end‑tidal carbon dioxide (EtCO₂), airway respiration rate (AwRR), blood oxygen saturation (SpO₂), and pulse rate (PR) in a single device.

Q: What is mainstream measurement technology?

A: Mainstream technology places the CO₂ sensor directly in the patient's breathing circuit via an airway adapter, providing real‑time, accurate EtCO₂ measurements at the airway.

Q: What patient populations is the device suitable for?

A: The GHM-CA20M is suitable for adult, pediatric, and infant patients.

Q: How long does the battery last?

A: The built‑in rechargeable lithium battery provides up to 8 hours of continuous use.

Q: Does the device have alarm functions?

A: Yes. The GHM-CA20M features audible and visual alarms with adjustable limits for EtCO₂, respiration rate, SpO₂, and pulse rate, plus low battery and adapter off alerts.

Q: Can I calibrate the device myself?

A: Yes. Users can calibrate the device independently to ensure ongoing measurement accuracy.

Q: Can the device be used in high‑altitude areas?

A: Yes. The GHM-CA20M features atmospheric pressure compensation and is designed to function accurately in high altitude environments.

Q: What clinical settings is the device suitable for?

A: The GHM-CA20M is suitable for emergency departments, ICUs, operating rooms, respiratory departments, and pre‑hospital emergency transfer.

Q: What is included in the package?

A: The package includes the GHM-CA20M main unit, airway adapter, breathing tube, built‑in rechargeable battery, and user manual.

View full details