WhatsApp USA: +1 6032769350 | WhatsApp HK: +852 63697831
Global Healthcare Medical
GHM EHF Epidemic Hemorrhagic Fever Virus Antibody IgM ELISA Kit US – 96-Well Solid-Phase ELISA for Semi-Quantitative Determination of Anti-EHF Virus IgM in Serum & Plasma (96T/Kit)
GHM EHF Epidemic Hemorrhagic Fever Virus Antibody IgM ELISA Kit US – 96-Well Solid-Phase ELISA for Semi-Quantitative Determination of Anti-EHF Virus IgM in Serum & Plasma (96T/Kit)
SKU: GHM EHF Epidemic Hemorrhagic Fever Virus Antibody IgM ELISA Kit US
Brand: Global Healthcare Medical
Product Overview
Global Healthcare Medical GHM EHF Epidemic Hemorrhagic Fever Virus Antibody IgM ELISA Kit US is a 96-well enzyme-linked immunosorbent assay (ELISA) designed for the semi-quantitative determination of immunoglobulin M (IgM)-class antibodies directed against EHF virus antigens in human serum and plasma specimens. EHF virus belongs to the genus Orthohantavirus within the family Hantaviridae and the order Bunyavirales, a group of enveloped viruses with a negative-sense, tripartite single-stranded RNA genome. The three RNA segments — small (S), medium (M), and large (L) — encode the nucleocapsid (N) protein, the two envelope glycoproteins Gn and Gc that form the surface spike complexes, and the RNA-dependent RNA polymerase respectively. The viral envelope is derived from host cell membranes and studded with Gn/Gc spike projections, while the N protein encapsidates each RNA segment to form ribonucleoprotein complexes. Members of this genus are maintained in rodent reservoir hosts and are studied within the broader field of bunyaviral molecular biology and serological characterisation, alongside other segmented negative-strand RNA viruses.
The IgM class is the first immunoglobulin isotype to appear in a primary humoral response to a viral antigen, before class switching to IgG or IgA, and it circulates predominantly as a pentamer in which five monomeric units are linked by disulfide bonds and a joining (J) chain, giving ten antigen-binding sites per molecule. Because of its high molecular mass, IgM is largely confined to the intravascular compartment and does not readily transude into secretory fluids — a distribution property that determines the specimen types appropriate to IgM-class serology. Measurement of anti-EHF virus antibody IgM is used in research settings to characterise early-phase humoral reactivity to hantaviral antigens, study immunoglobulin class distribution across antiviral antibody responses, and investigate viral antigen–antibody interaction profiles in virological research models.
The kit employs a solid-phase ELISA principle with EHF virus antigen immobilized on the solid phase and enzyme-conjugated anti-human IgM detection antibodies in the liquid phase. Results are evaluated against a cut-off value established from the assay calibrators, yielding a semi-quantitative interpretation expressed as a cut-off index. The assay is configured for a 50 µL sample volume and a total incubation time of approximately 1.5–2.5 hours (depending on protocol configuration), with absorbance read at 450 nm using standard microplate ELISA equipment. The kit is supplied in a 96-test/box format with an 18-month shelf life.
Intended Use: For laboratory research use only. This product is not intended for use in diagnostic procedures, not for therapeutic use, and not for clinical decision-making. Results should be interpreted by qualified laboratory professionals in the context of research applications.
Key Features & Benefits
Solid-Phase ELISA for Anti-EHF Virus Antibody IgM Detection
The assay utilizes a solid-phase ELISA format in which EHF virus antigen is coated onto the 96-well microplate and enzyme-conjugated anti-human IgM detection antibodies are supplied in liquid phase. This configuration supports specific antibody capture and signal generation, enabling evaluation of IgM-class antiviral reactivity in serum and plasma matrices. Because the detection conjugate is directed against the mu heavy chain of human IgM, the readout is restricted to the IgM isotype and does not report total antiviral immunoglobulin content — an important distinction when IgM and IgG classes are studied as separate analytes in a paired serological design.
|
Feature |
Benefit |
|
Solid-phase ELISA format |
Established principle for antiviral IgM detection |
|
Anti-human IgM detection |
IgM-isotype specific readout, not total immunoglobulin |
|
Viral antigen coating |
Presents native hantaviral glycoprotein and nucleocapsid epitopes |
|
Cut-off index evaluation |
Standardised semi-quantitative interpretation |
Antigen Derived from an Enveloped, Tripartite RNA Virus
The target virus presents two structurally distinct antigen classes that are both relevant to antibody recognition: the envelope glycoproteins Gn and Gc, which form the surface spike complexes and are heavily N-glycosylated, and the nucleocapsid N protein, which is abundantly expressed and highly immunogenic. Coating with a whole-virus antigen preparation preserves conformational glycoprotein epitopes that depend on native folding and glycosylation, rather than presenting denatured linear sequences alone. The tripartite genome organisation and the resulting antigen composition also mean that reactivity profiles obtained on a whole-virus preparation reflect the combined glycoprotein and nucleocapsid response, which is directly relevant to research programmes profiling antiviral humoral responses across the Bunyavirales order. This design rationale distinguishes the format from single-recombinant-antigen ELISA configurations.
|
Feature |
Benefit |
|
Whole-virus antigen coating |
Preserves conformational glycoprotein epitopes |
|
Combined Gn/Gc and N protein antigen set |
Reflects the full antiviral antibody response |
|
Native glycosylation retained |
Supports glycoprotein-dependent epitope recognition |
|
Distinct from single-recombinant formats |
Complements recombinant-antigen ELISA configurations |
Performance Aligned with Published Antiviral IgM ELISA Benchmarks
Published performance data for ELISA-format antiviral IgM assays report sample volumes of 50–100 µL, a colorimetric microplate readout at 450 nm, and time to results of approximately 1–5 hours, with results expressed as a cut-off index derived from kit calibrators rather than a mass-concentration standard. Precision data for antibody-class ELISA formats of this type generally indicate intra-assay CV values below 10% and inter-assay CV values below 15%. Sample volumes of 50 µL are used in this configuration, and absorbance is read at 450 nm. Because the same assay format is commonly applied to paired IgM and IgG determinations, laboratory professionals should confirm the applicable calibrator and cut-off definitions against the kit documentation supplied with each lot, and should exercise independent judgment in interpreting cut-off index values in a research context.
|
Feature |
Benefit |
|
Cut-off index based semi-quantitative readout (published benchmark) |
Standardised qualitative and semi-quantitative framework |
|
Intra-assay CV <10%; inter-assay CV <15% (published benchmark) |
Repeatability and reproducibility suitable for laboratory use |
|
Paired isotype design |
Supports IgM and IgG comparison in the same format |
Standardized 96-Well Workflow with 50 µL Sample Volume
The assay is formatted for standard 96-well microplate processing with a 50 µL sample volume and a total incubation time of approximately 1.5–2.5 hours. Absorbance is measured at 450 nm, aligning with widely available ELISA readers and washers.
|
Feature |
Benefit |
|
96 tests/box |
Practical batch configuration for research workflows |
|
50 µL sample volume |
Standard ELISA sample requirement |
|
450 nm reading |
Compatible with common microplate spectrophotometers |
|
~1.5–2.5 hour total incubation |
Efficient turnaround for batch processing |
18-Month Shelf Life
Extended reagent stability supports inventory planning and reduces replacement frequency in laboratory settings.
|
Feature |
Benefit |
|
18-month shelf life |
Extended inventory stability |
|
Consistent batch supply |
Supports repeatable research workflows |
Kit Contents & Pricing (EXW US Dollar)
|
Product Description |
Package |
Shelf Life |
Price/Kit (USD) |
CPT (USD/Test) |
|
EHF Epidemic Hemorrhagic Fever Virus Antibody IgM ELISA Kit |
96 Tests/Box |
18 Months |
$38.00 |
$0.3958 |
Cost per test: approximately $0.40, based on a 96-test kit configuration.
Product Specifications
|
Specification |
Detail |
|
Model / SKU |
GHM EHF Epidemic Hemorrhagic Fever Virus Antibody IgM ELISA Kit US |
|
Product Type |
Enzyme-Linked Immunosorbent Assay (ELISA) Kit |
|
Intended Use |
Semi-quantitative determination of anti-EHF virus antibody IgM in human serum or plasma; for laboratory research use only; not for use in diagnostic procedures; not for therapeutic use |
|
Assay Principle |
Solid-phase ELISA with anti-human IgM detection |
|
Target Analyte |
Anti-EHF virus antibody, immunoglobulin M (IgM) class |
|
Immunoglobulin Class |
IgM (mu heavy chain specific; pentameric) |
|
Antigen |
EHF virus antigen (whole-virus preparation; Gn/Gc glycoprotein and N protein epitopes) |
|
Specimen Types |
Human serum, plasma |
|
Specimen Volume |
50 µL/well |
|
Package Size |
96 Tests/Box |
|
Shelf Life |
18 Months |
|
Reading Wavelength |
450 nm |
|
Total Incubation Time |
Approximately 1.5–2.5 hours (protocol-dependent) |
|
Precision (published benchmark) |
Intra-assay CV <10%; inter-assay CV <15% |
|
Result Interpretation |
Cut-off index based semi-quantitative readout (published benchmark) |
|
Calibration Format |
Cut-off index referenced to kit calibrators (not mass-concentration calibrated) |
|
Regulatory Status |
Manufactured under EN ISO 13485 certified quality management system |
Why Laboratories Choose Global Healthcare Medical
|
Consideration |
GHM EHF Epidemic Hemorrhagic Fever Virus Antibody IgM ELISA Kit US |
|
Solid-phase ELISA with anti-human IgM detection |
IgM-isotype specific readout, not total immunoglobulin |
|
Whole-virus antigen coating |
Preserves conformational glycoprotein epitopes |
|
Combined Gn/Gc and N protein antigen set |
Reflects the full antiviral antibody response |
|
Paired isotype design |
Supports IgM and IgG comparison in the same format |
|
Performance aligned with published antiviral IgM ELISA benchmarks |
Cut-off index based; CV <10%/<15% |
|
Cost-effective research serology |
$0.3958 per test; $38.00 per 96-test kit |
|
18-month shelf life |
Extended inventory stability |
|
Standard 96-well format |
Compatible with routine ELISA equipment |
|
ISO 13485 certified |
Quality management system compliance |
About Global Healthcare Medical
Global Healthcare Medical connects clinical laboratories, research institutions, and blood screening centers with diagnostic reagents and analytical systems designed for reliable operation in demanding healthcare environments. The GHM EHF Epidemic Hemorrhagic Fever Virus Antibody IgM ELISA Kit US is part of our professional ELISA reagent portfolio, developed to support standardized, reproducible laboratory workflows.
Our focus is on dependable analytical performance, clear documentation, and responsive support for professional laboratory operations.