GHM Ferritin Semi-Quantitative Rapid Test US – Semi-Quantitative Detection of Human Ferritin with 5-Minute Results, Whole Blood / Serum / Plasma Sample Compatibility, and Professional Point-of-Care Use
GHM Ferritin Semi-Quantitative Rapid Test US – Semi-Quantitative Detection of Human Ferritin with 5-Minute Results, Whole Blood / Serum / Plasma Sample Compatibility, and Professional Point-of-Care Use
SKU: GHM Ferritin Semi-Quantitative Rapid Test US
Brand: Global Healthcare Medical
Product Overview
Global Healthcare Medical GHM Ferritin Semi-Quantitative Rapid Test US is a lateral flow chromatographic immunoassay designed for the semi-quantitative detection of human ferritin in human whole blood, serum, or plasma specimens. The kit is intended for use by healthcare professionals as an aid in the diagnosis of iron deficiency anemia.
Iron deficiency (ID) is among the most common global hematologic disorders and a leading contributor to the global disease burden. Over one-third of individuals worldwide have iron deficiency anemia (IDA), with children and pregnant women living in low- and middle-income countries disproportionately impacted. In 2021, an estimated 24.3% of the global population had anemia, with iron deficiency recognized as the leading cause. Serum ferritin is the most specific routine test for diagnosing ID, with values reflective of body iron stores. A serum ferritin concentration of less than 30 μg/L has a high specificity and sensitivity for diagnosing iron deficiency in adults. However, the diagnosis of ID is frequently overlooked by clinicians, and access to timely testing remains a barrier in many settings.
The GHM Ferritin Semi-Quantitative Rapid Test US provides a practical, point-of-care screening solution for the rapid assessment of ferritin levels, enabling timely clinical decision-making and supporting appropriate patient management. The test delivers semi-quantitative results in just 5 minutes, supporting rapid clinical assessment at the point of care. The test is compatible with whole blood (venipuncture or fingerstick), serum, and plasma specimens, providing flexible sample collection options suitable for a wide range of clinical settings.
The kit is intended for in vitro diagnostic use and professional use only, suitable for application scenarios including primary care clinics, hematology clinics, prenatal screening programs, and clinical laboratories. The VivaDiag product line is manufactured under an EN ISO 13485 certified quality management system covering in vitro diagnostic test kits and analyzers based on immunochromatography.
Key Features & Benefits
Colloidal Gold Immunochromatography – Reliable Semi-Quantitative Detection
The GHM Ferritin Semi-Quantitative Rapid Test US is based on lateral flow chromatographic immunoassay technology. The test strip contains colloidal gold-conjugated antibodies specific to human ferritin, along with immobilized capture antibodies on the test line. The test provides semi-quantitative results by comparing the intensity of the test line against a reference scale, enabling healthcare professionals to estimate ferritin concentrations and classify iron status using sex-specific cut-off values (30 ng/mL for males, 13 ng/mL for females).
| Feature | Benefit |
|---|---|
| Colloidal gold immunochromatography | Established and reliable detection method |
| Semi-quantitative analysis | Provides estimated ferritin concentration for clinical decision-making |
| Ferritin-specific antibodies | Targeted detection of human ferritin |
| Sex-specific cut-off values | Accounts for physiological differences between males and females |
| Internal procedural control | Confirms proper test performance |
Fast Results – 5 Minutes
The GHM Ferritin Semi-Quantitative Rapid Test US provides semi-quantitative results in just 5 minutes, supporting rapid clinical decision-making and efficient patient workflow in point-of-care settings. Traditional laboratory-based ferritin testing requires venous blood collection and laboratory processing, which can delay clinical decision-making. Rapid point-of-care testing addresses these limitations by delivering actionable results within minutes.
| Feature | Benefit |
|---|---|
| 5-minute test time | Rapid turnaround for timely clinical decisions |
| Point-of-care compatibility | Suitable for primary care clinics and hematology clinics |
| Efficient workflow | Enables immediate patient assessment |
| Quick sample-to-result | Supports high-throughput screening environments |
Whole Blood / Serum / Plasma Compatibility – Flexible Sample Collection
The GHM Ferritin Semi-Quantitative Rapid Test US is compatible with whole blood (venipuncture or fingerstick), serum, and plasma specimens, providing flexible sample collection options to accommodate different clinical protocols and patient needs. The test requires only a small sample volume, making it suitable for both clinic-based and field-based testing scenarios.
| Feature | Benefit |
|---|---|
| Whole blood / serum / plasma | Flexible sample collection options |
| Fingerstick or venipuncture whole blood | Suitable for different clinical settings |
| Small sample volume required | Practical for pediatric and adult patients |
| No special equipment required | Streamlined workflow in clinical settings |
Clinical Utility – Aid for Diagnosis of Iron Deficiency Anemia
The GHM Ferritin Semi-Quantitative Rapid Test US is intended for use as an aid in the diagnosis of iron deficiency anemia. The test provides rapid semi-quantitative detection of ferritin, enabling timely clinical decision-making and supporting patient management.
The test is particularly valuable in settings where rapid identification of iron deficiency supports timely initiation of iron supplementation and prevention of associated complications. Serum ferritin is the most sensitive and specific test to diagnose iron deficiency, with values reflective of body iron stores. The test is also suitable for use in decentralized testing environments where laboratory infrastructure may be limited. Point-of-care ferritin testing may be a useful adjunct with good sensitivity to detect iron deficiency in appropriate clinical contexts.
| Feature | Benefit |
|---|---|
| Iron deficiency detection aid | Supports identification of iron deficiency and iron deficiency anemia |
| Risk stratification support | Helps identify patients requiring iron supplementation |
| Screening test utility | Suitable for use as a screening test in clinical settings |
| Field-friendly testing | No instrumentation required, suitable for decentralized settings |
| Clinical versatility | Useful across primary care clinics, hematology clinics, and clinical laboratories |
High Accuracy – Trusted Clinical Performance
The GHM Ferritin Semi-Quantitative Rapid Test US is designed to deliver reliable clinical performance with high sensitivity and specificity. The product specifications report a sensitivity of 94.7%, specificity of 95.2%, and accuracy of 95.1%. Published evaluations of point-of-care ferritin assays have demonstrated high sensitivity for detecting iron deficiency, with one validation trial reporting 90% sensitivity and 96% specificity using the WHO cut-off of <30 ng/mL. A prospective cohort analysis reported high sensitivity (88.7%) for point-of-care ferritin in detecting iron deficiency (ferritin < 30 ng/mL) compared to laboratory serum ferritin.
| Parameter | Specification |
|---|---|
| Sensitivity | 94.7% |
| Specificity | 95.2% |
| Accuracy | 95.1% |
| Cut-off Values | 30 ng/mL (males); 13 ng/mL (females) |
| Specimen | Whole Blood (venipuncture or fingerstick) / Serum / Plasma |
| Time to Result | 5 minutes |
| Storage Temperature | 2–30°C (35.6–86°F) |
| Shelf Life | 2 years |
Performance characteristics based on product specifications and published evaluations of rapid ferritin tests. A validation trial of a point-of-care ferritin system using capillary whole blood reported a sensitivity of 90% and specificity of 96% for diagnosing iron deficiency using the WHO cut-off of <30 ng/mL. A prospective cohort analysis of point-of-care ferritin testing reported high sensitivity (88.7%) but lower specificity (34.8%) compared to laboratory serum ferritin in detecting iron deficiency. Detection is optimal when specimens are collected and processed according to the manufacturer's instructions, and the test is best suited for use as an aid in the diagnosis of iron deficiency anemia. The test provides a preliminary result; laboratory-based quantitative testing is recommended for confirmation and monitoring.
ISO 13485 Certified – Quality and Safety Compliance
The VivaDiag product line is manufactured under an EN ISO 13485 certified quality management system, demonstrating compliance with stringent international standards for the design, development, manufacture, and distribution of in vitro diagnostic test kits and analyzers.
| Feature | Benefit |
|---|---|
| EN ISO 13485 certification | Quality management system compliance |
| IVD scope | Certified for in vitro diagnostic test kits |
| Quality assurance | Meets high standards of quality and safety |
| Professional-grade | Designed for healthcare professional use |
CE Marked – European Conformity
The GHM Ferritin Semi-Quantitative Rapid Test US is CE marked for professional in vitro diagnostic use, demonstrating conformity with applicable European regulatory requirements for diagnostic medical devices.
| Feature | Benefit |
|---|---|
| CE marking | Regulatory compliance for professional use |
| Professional IVD use | Designed for trained healthcare personnel |
| Quality compliance | Meets European regulatory standards |
Product Specifications
| Specification | Detail |
|---|---|
| Model / SKU | GHM Ferritin Semi-Quantitative Rapid Test US |
| Product Code | OFE-T402 |
| Product Type | Ferritin Semi-Quantitative Rapid Test (Colloidal Gold) |
| Intended Use | Semi-quantitative detection of human ferritin in human whole blood, serum, or plasma specimens; used as an aid in the diagnosis of iron deficiency anemia |
| Detection Principle | Lateral flow chromatographic immunoassay; colloidal gold |
| Target Analyte | Human ferritin |
| Specimen | Whole Blood (venipuncture or fingerstick) / Serum / Plasma |
| Time to Result | 5 minutes |
| Sensitivity | 94.7% |
| Specificity | 95.2% |
| Accuracy | 95.1% |
| Cut-off Values | 30 ng/mL (males); 13 ng/mL (females) |
| Storage Temperature | 2–30°C (35.6–86°F) |
| Shelf Life | 2 years |
| Application Scenario | Primary care clinic, hematology clinic, prenatal screening program, clinical laboratory, point-of-care |
| Regulatory Status | Manufactured under EN ISO 13485 certified quality management system; CE marked |
| Intended User | Professional healthcare use only |
| Kit Sizes | 10 tests/kit; 25 tests/kit |
| Kit Contents | Test Cassette, Buffer, Disposable Dropper, Instructions for Use |
Important Testing Notes:
-
Allow the test kit and sample to reach room temperature (18–30°C) prior to testing.
-
For fingerstick whole blood, clean the fingertip with an alcohol swab and allow it to dry; collect blood using a sterile lancet.
-
Apply the specimen to the cassette sample well according to the instructions, followed by the buffer.
-
Results should be interpreted at 5 minutes. Do not interpret results after 10 minutes.
-
The test provides semi-quantitative results by comparing test line intensity against the reference scale.
-
The test is intended for screening and preliminary assessment. Laboratory-based quantitative testing is recommended for confirmation and monitoring of ferritin levels.
-
Serum ferritin should be interpreted in the correct clinical context, as ferritin is an acute-phase reactant and may be elevated in inflammatory conditions even when iron stores are low.
-
A serum ferritin level <30 μg/L for an adult is diagnostic of iron deficiency; levels of 30–100 μg/L in an anemic adult may represent iron deficiency if there is coexisting inflammatory disease.
-
Healthcare professionals should exercise clinical consideration and professional judgment with any test result.
Why Clinical Professionals Choose Global Healthcare Medical
| Consideration | GHM Ferritin Semi-Quantitative Rapid Test US |
|---|---|
| Colloidal gold immunochromatography | Established and reliable detection technology |
| 5-minute test time | Rapid turnaround for timely clinical decisions |
| Whole blood / serum / plasma compatibility | Flexible and convenient sampling options |
| Semi-quantitative detection | Provides estimated ferritin concentration for clinical decision-making |
| High sensitivity and specificity | 94.7% sensitivity, 95.2% specificity, and 95.1% accuracy |
| 90% sensitivity in validation trial | High sensitivity demonstrated in independent clinical validation |
| Sex-specific cut-off values | Accounts for physiological differences between males and females |
| Screening test utility | Suitable for use as a screening test in clinical settings |
| ISO 13485 certified | Quality management system compliance |
| CE marked | Regulatory compliance for professional use |
| Point-of-care compatible | Suitable for primary care clinics, hematology clinics, and clinical laboratories |
About Global Healthcare Medical
Global Healthcare Medical is dedicated to connecting healthcare providers, retailers, and distributors with high-quality medical devices designed for reliable performance. The GHM Ferritin Semi-Quantitative Rapid Test US is part of our professional diagnostic line, developed to support accurate, efficient, and accessible point-of-care testing in clinical environments.