WhatsApp USA: +1 6032769350 | WhatsApp HK: +852 63697831
Global Healthcare Medical
GHM FT3 Thyroxine ELISA Kit US – 96-Well Competitive ELISA for Quantitative Determination of Free Triiodothyronine (fT3) in Serum & Plasma (96T/Kit)
GHM FT3 Thyroxine ELISA Kit US – 96-Well Competitive ELISA for Quantitative Determination of Free Triiodothyronine (fT3) in Serum & Plasma (96T/Kit)
SKU: GHM FT3 Thyroxine ELISA Kit US
Brand: Global Healthcare Medical
Product Overview
Global Healthcare Medical GHM FT3 Thyroxine ELISA Kit US is a 96-well enzyme-linked immunosorbent assay (ELISA) designed for the quantitative determination of Free Triiodothyronine (fT3) in human serum and plasma specimens. Free T3 represents the biologically active, unbound fraction of triiodothyronine and is considered a more direct indicator of thyroid hormone status than total T3 in research settings, particularly in specimens where carrier protein concentrations may be altered.
The assay employs a competitive inhibition ELISA principle. The microplate is pre-coated with an antibody specific to fT3 (or with fT3 antigen, depending on configuration). During incubation, fT3 in the specimen competes with a fixed amount of enzyme-conjugated or biotinylated fT3 for binding to the immobilized capture molecules. After washing and substrate development, color intensity is inversely proportional to the fT3 concentration in the sample. Absorbance is measured at 450 nm, and fT3 concentrations are derived from a standard curve.
The kit is configured for a 50 µL sample volume and a total time-to-result of approximately 2–2.5 hours, supporting routine laboratory batch processing. The kit is supplied in a 96-test/box format with an 18-month shelf life.
Intended Use: For laboratory research use only. This product is not intended for use in diagnostic procedures, not for therapeutic use, and not for clinical decision-making. Results should be interpreted by qualified laboratory professionals in the context of research applications.
Key Features & Benefits
Competitive Inhibition ELISA Principle
The assay is built on a solid-phase competitive ELISA format. Capture molecules specific for fT3 are immobilized on the 96-well microplate. Sample fT3 and a fixed amount of detection conjugate compete for a limited number of binding sites. This competitive design is the established reference format for small-molecule hapten quantitation and yields an inverse relationship between fT3 concentration and signal intensity — higher fT3 in the specimen produces a lower absorbance reading at 450 nm.
| Feature | Benefit |
|---|---|
| Competitive inhibition ELISA format | Established reference principle for free hormone quantitation |
| fT3-specific capture on solid phase | Targeted recognition of the free (unbound) hormone fraction |
| Inverse signal-to-analyte relationship | Reliable quantitation across the assay range |
Performance Benchmarks for Free T3 ELISA
Published performance data for competitive-format fT3 ELISA report intra-assay CV of approximately <8%–<10% and inter-assay CV of approximately <10%–<12%, depending on the specific platform and protocol. Analytical sensitivity for competitive fT3 ELISA formats is typically reported in the sub-pg/mL range (e.g., 0.41–0.94 pg/mL across referenced configurations), with assay ranges spanning approximately 0.78–100 pg/mL for serum/plasma applications. These reference benchmarks support dependable performance expectations for research-oriented free thyroid hormone quantitation.
| Feature | Benefit |
|---|---|
| Intra-assay CV ~<8%–<10% (published benchmark) | Repeatability suitable for batch processing |
| Inter-assay CV ~<10%–<12% (published benchmark) | Reproducibility across assay runs |
| Sub-pg/mL analytical sensitivity (published benchmark) | Supports detection at low free T3 concentrations |
Standardized 96-Well Workflow with 50 µL Sample Volume
The assay is formatted for standard 96-well microplate processing with a 50 µL sample volume and a total time-to-result of approximately 2–2.5 hours. Absorbance is measured at 450 nm, aligning with widely available ELISA readers and washers.
| Feature | Benefit |
|---|---|
| 96 tests/box | Practical batch configuration for research workflows |
| 50 µL sample volume | Standard ELISA sample requirement |
| 450 nm reading | Compatible with common microplate spectrophotometers |
| ~2–2.5 hour total assay time | Efficient turnaround for batch processing |
18-Month Shelf Life
Extended reagent stability supports inventory planning and reduces replacement frequency in laboratory settings.
| Feature | Benefit |
|---|---|
| 18-month shelf life | Extended inventory stability |
| Consistent batch supply | Supports repeatable research workflows |
Kit Contents & Pricing (EXW US Dollar)
| Product Description | Package | Shelf Life | Price/Kit (USD) | CPT (USD/Test) |
|---|---|---|---|---|
| FT3 Thyroxine ELISA Kit | 96 Tests/Box | 18 Months | $32.00 | $0.3333 |
Cost per test: approximately $0.33, based on a 96-test kit configuration.
Product Specifications
| Specification | Detail |
|---|---|
| Model / SKU | GHM FT3 Thyroxine ELISA Kit US |
| Product Type | Enzyme-Linked Immunosorbent Assay (ELISA) Kit |
| Intended Use | Quantitative determination of Free Triiodothyronine (fT3) in human serum or plasma; for laboratory research use only; not for use in diagnostic procedures; not for therapeutic use |
| Assay Principle | Competitive inhibition ELISA |
| Target Analyte | Free Triiodothyronine (fT3) |
| Specimen Types | Human serum, plasma |
| Specimen Volume | 50 µL/well |
| Package Size | 96 Tests/Box |
| Shelf Life | 18 Months |
| Reading Wavelength | 450 nm |
| Total Time-to-Result | Approximately 2–2.5 hours |
| Precision (published benchmark) | Intra-assay CV <8%–<10%; inter-assay CV <10%–<12% |
| Analytical Sensitivity (published benchmark) | Sub-pg/mL range (e.g., 0.41–0.94 pg/mL for referenced configurations) |
| Regulatory Status | Manufactured under EN ISO 13485 certified quality management system |
Why Laboratories Choose Global Healthcare Medical
| Consideration | GHM FT3 Thyroxine ELISA Kit US |
|---|---|
| Competitive inhibition principle | Established reference format for free hormone quantitation |
| fT3-specific capture | Targeted recognition of the biologically active free fraction |
| Performance aligned with published benchmarks | Intra-assay CV <8%–<10%; inter-assay CV <10%–<12% |
| Cost-effective research quantitation | $0.3333 per test; $32.00 per 96-test kit |
| 18-month shelf life | Extended inventory stability |
| Standard 96-well format | Compatible with routine ELISA equipment |
| ISO 13485 certified | Quality management system compliance |
About Global Healthcare Medical
Global Healthcare Medical connects clinical laboratories, research institutions, and blood screening centers with diagnostic reagents and analytical systems designed for reliable operation in demanding healthcare environments. The GHM FT3 Thyroxine ELISA Kit US is part of our professional ELISA reagent portfolio, developed to support standardized, reproducible laboratory workflows.
Our focus is on dependable analytical performance, clear documentation, and responsive support for professional laboratory operations.
