WhatsApp USA: +1 6032769350 | WhatsApp HK: +852 63697831
Global Healthcare Medical
GHM Gastrointestinal US Gastrointestinal Disease Rapid Test (FIA) – Qualitative/Quantitative, 15-Minute, Stool Specimen
GHM Gastrointestinal US Gastrointestinal Disease Rapid Test (FIA) – Qualitative/Quantitative, 15-Minute, Stool Specimen
SKU: GHM Gastrointestinal US
Brand: Global Healthcare Medical
Product Overview
Global Healthcare Medical GHM Gastrointestinal US Gastrointestinal Disease Rapid Test (FIA) is a fluorescence immunoassay (FIA) designed for the qualitative and quantitative detection of gastrointestinal disease biomarkers and pathogens in human stool specimens. The test is used as an aid in the diagnosis of gastrointestinal infections and conditions, including bacterial and viral gastroenteritis, Helicobacter pylori infection, and gastrointestinal bleeding. Gastrointestinal infections remain a significant global health burden, and rapid antigen detection methods have become increasingly important for timely diagnosis and patient management.
The GHM Gastrointestinal US is intended for use with the FIA Analyzer (VIM01), a compact benchtop analyzer that utilizes fluorescence immunochromatography technology. The analyzer features auto calibration, barcode identification, and a built-in memory capacity of 50,000 results. The analyzer delivers reliable results in 10 ± 5 seconds after the test device is inserted.
The system is designed for professional use in clinical laboratories, hospitals, and clinics. The FIA analyzer operates with a small sample volume and provides fast, reliable results with simple operation.
This product is for in vitro diagnostic use only. For professional use only.
Key Features & Benefits
Multiplex Gastrointestinal Pathogen Detection – Comprehensive Differential Assessment
The GHM Gastrointestinal US delivers qualitative and quantitative results for multiple gastrointestinal biomarkers and pathogens from a single stool specimen. This multiplex panel approach enables simultaneous detection and differentiation of viral, bacterial, and parasitic gastrointestinal pathogens, as well as biomarkers of intestinal inflammation and gastrointestinal bleeding, supporting timely clinical decision-making. Rapid diagnostic tests for gastrointestinal pathogens, including norovirus, rotavirus, and adenovirus, are available individually or in combination.
| Feature | Benefit |
|---|---|
| Multiplex panel | Simultaneous detection of multiple GI pathogens and biomarkers |
| Single specimen | One stool sample for all test items |
| Intended use | Aid in diagnosis of gastrointestinal infections and conditions |
| Test time | 10 – 15 minutes |
| Clinical utility | Supports differentiation between viral, bacterial, and parasitic GI infections |
| Flexible combination | Multiple test items can be combined for customized panels |
Comprehensive Test Menu – Broad Pathogen and Biomarker Coverage
The GHM Gastrointestinal US supports detection of a comprehensive panel of gastrointestinal disease pathogens and biomarkers, providing broad coverage for clinical gastroenterology and infectious disease testing needs.
| Pathogen/Biomarker Category | Test Items |
|---|---|
| Viral Pathogens | Rotavirus, Norovirus GI/GII, Adenovirus, Astrovirus |
| Bacterial Pathogens | Helicobacter pylori (H. pylori), Clostridium difficile (C. difficile) Toxin A/B, Campylobacter, Salmonella, Shigella |
| Parasitic Pathogens | Giardia lamblia, Cryptosporidium, Entamoeba histolytica |
| GI Biomarkers | Fecal Occult Blood (FOB), Fecal Calprotectin, Fecal Lactoferrin, Transferrin |
Multiple panel configurations available. Contact Global Healthcare Medical for the complete test menu and panel customization options.
Sandwich Immunodetection Method – Fluorescence Immunoassay Principle
The GHM Gastrointestinal US uses a sandwich immunodetection method. When the sample is added to the sample well of the test device, fluorescence-labeled detector antibodies bind to target gastrointestinal pathogen antigens or biomarkers in the sample. As the sample mixture migrates on the nitrocellulose matrix of the test strip by capillary action, the complexes of detector antibody and target are captured by immobilized capture antibodies at specific test lines on the strip. Thus, the more target antigen or biomarker in the specimen, the more complexes accumulate on the test strip. The signal intensity of the fluorescent signal reflects the amount of target captured, and the FIA Analyzer displays the test result. Fluorescent immunoassay systems for stool specimen testing have demonstrated high sensitivity and specificity for gastrointestinal pathogen detection, with results showing high consistency with reference methods.
| Feature | Benefit |
|---|---|
| Sandwich immunodetection | Reliable measurement principle |
| Fluorescence signal | Clear positive/negative or quantitative determination |
| Test strip technology | Pathogen-specific antibodies at test lines; control line verification |
| Objective results | Results interpreted automatically by analyzer |
| Small sample volume | Minimizes specimen requirements |
FIA Analyzer – Advanced Technical Platform
The GHM Gastrointestinal US is used with the FIA Analyzer (VIM01), a compact fluorescence immunoassay analyzer featuring auto calibration, barcode identification, and a large memory capacity.
| Feature | Benefit |
|---|---|
| Auto calibration | Reduces manual calibration steps |
| Barcode identification | 2D barcode scanning for test device identification |
| Code chip coding | Automatic parameter recognition |
| Memory capacity | 50,000 results storage |
| Connectivity | Direct LIS/HIS connection |
| Display | 3.5-inch LCD screen |
| Dimensions | 173 × 210 × 75.8 mm |
| Weight | 1.5 kg |
| Printer | Built-in printer |
| Multi-parameter detection | Analyzer can detect 30+ parameters |
Wide Storage Temperature – No Cold Chain Required
The test kit is designed for convenient storage and transport, with a storage temperature range of 2 ~ 30°C, eliminating the need for cold chain logistics.
| Specification | Detail |
|---|---|
| Kit storage temperature | 2 ~ 30°C |
| Operating temperature | 18 ~ 25°C |
| Relative humidity | 20 – 90% |
| Shelf life | Up to 18 months |
Simple Operation – Professional Laboratory Testing
The test procedure involves three simple steps: mix the stool sample with extraction buffer, add the mixed specimen, and insert the device into the analyzer.
| Step | Action |
|---|---|
| 1 | Mix the stool sample with extraction buffer |
| 2 | Add the mixed specimen to the test device |
| 3 | Insert device into the analyzer |
Product Specifications
| Specification | Detail |
|---|---|
| Model / SKU | GHM Gastrointestinal US |
| Product Type | Gastrointestinal Disease Rapid Test (FIA) |
| Specimen | Human feces (stool) |
| Sample Volume | 40 – 100 mg |
| Test Time | 10 – 15 minutes |
| Measuring Range | Negative / Positive (qualitative); Quantitative for select biomarkers |
| Operating Temperature | 18 ~ 25°C |
| Storage Temperature | 2 ~ 30°C |
| Shelf Life | Up to 18 months |
| Analyzer Compatibility | FIA Analyzer (VIM01) |
| Analyzer Display | 3.5-inch LCD |
| Analyzer Dimensions | 173 × 210 × 75.8 mm |
| Analyzer Weight | 1.5 kg |
| Analyzer Memory | 50,000 results |
| Analyzer Connectivity | Direct LIS/HIS |
| Analyzer Test Time | 10 ± 5 seconds |
| Analyzer Operation Temperature | 5 ~ 40°C |
| Analyzer Storage Temperature | -10 ~ 40°C |
| Relative Humidity | 20 – 90% |
| Intended Use | In vitro diagnostic use; professional use only |
| Package Options | Kit format |
Why Clinical Laboratories Choose Global Healthcare Medical
| Consideration | GHM Gastrointestinal US |
|---|---|
| Multiplex results | Multiple pathogen and biomarker detection from one specimen |
| Broad pathogen coverage | Viral, bacterial, and parasitic GI pathogens in a single panel |
| Dedicated specimen type | Human feces (stool) |
| Fast test time | 10 – 15 minutes per test |
| Fast analyzer reading | 10 ± 5 seconds per test |
| Auto calibration | Reduces manual steps |
| Large memory | 50,000 results storage |
| LIS/HIS connectivity | Direct data integration |
| Convenient storage | 2 ~ 30°C, no cold chain required |
| Simple operation | Three-step test procedure |
| Multi-parameter platform | Analyzer supports 30+ parameters |