WhatsApp USA: +1 6032769350 | WhatsApp HK: +852 63697831
Global Healthcare Medical
GHM HAV Hepatitis A Virus Antibody IgM ELISA Kit US – 96-Well Solid-Phase ELISA for Semi-Quantitative Determination of Anti-HAV IgM in Serum & Plasma (96T/Kit)
GHM HAV Hepatitis A Virus Antibody IgM ELISA Kit US – 96-Well Solid-Phase ELISA for Semi-Quantitative Determination of Anti-HAV IgM in Serum & Plasma (96T/Kit)
SKU: GHM HAV Hepatitis A Virus Antibody IgM ELISA Kit US
Brand: Global Healthcare Medical
Product Overview
Global Healthcare Medical GHM HAV Hepatitis A Virus Antibody IgM ELISA Kit US is a 96-well enzyme-linked immunosorbent assay (ELISA) designed for the semi-quantitative determination of immunoglobulin M (IgM)-class antibodies directed against hepatitis A virus (HAV) antigens in human serum and plasma specimens. HAV is a non-enveloped, icosahedral virus with a positive-sense, single-stranded RNA genome, classified in the genus Hepatovirus within the family Picornaviridae. The genome is approximately 7.5 kb in length and carries a single long open reading frame that is translated into a polyprotein, subsequently processed into the structural capsid proteins VP1, VP2, VP3, and VP4 together with the non-structural proteins required for genome replication. The virion shell is built from 60 copies of the VP1–VP3 capsid subunits arranged in icosahedral symmetry, forming a compact particle with highly repetitive surface epitopes and no lipid envelope — a structural organisation that distinguishes HAV from enveloped RNA viruses and that determines how antibodies engage the virion surface. HAV is studied within the broader field of picornaviral molecular biology and serological characterisation, alongside other small non-enveloped positive-strand RNA viruses.
The IgM class is the first immunoglobulin isotype to appear in a primary humoral response to a viral antigen, before class switching to IgG or IgA, and it circulates predominantly as a pentamer in which five monomeric units are linked by disulfide bonds and a joining (J) chain, giving ten antigen-binding sites per molecule. Because of its high molecular mass, IgM is largely confined to the intravascular compartment and does not readily transude into secretory fluids — a distribution property that determines the specimen types appropriate to IgM-class serology. Measurement of anti-HAV antibody IgM is used in research settings to characterise early-phase humoral reactivity to picornaviral capsid antigens, study immunoglobulin class distribution across antiviral antibody responses, and investigate viral antigen–antibody interaction profiles in virological research models.
The kit employs a solid-phase ELISA principle with HAV antigen immobilized on the solid phase and enzyme-conjugated anti-human IgM detection antibodies in the liquid phase. Results are evaluated against a cut-off value established from the assay calibrators, yielding a semi-quantitative interpretation expressed as a cut-off index. The assay is configured for a 50 µL sample volume and a total incubation time of approximately 1.5–2.5 hours (depending on protocol configuration), with absorbance read at 450 nm using standard microplate ELISA equipment. The kit is supplied in a 96-test/box format with an 18-month shelf life.
Intended Use: For laboratory research use only. This product is not intended for use in diagnostic procedures, not for therapeutic use, and not for clinical decision-making. Results should be interpreted by qualified laboratory professionals in the context of research applications.
Key Features & Benefits
Solid-Phase ELISA for Anti-HAV Antibody IgM Detection
The assay utilizes a solid-phase ELISA format in which HAV antigen is coated onto the 96-well microplate and enzyme-conjugated anti-human IgM detection antibodies are supplied in liquid phase. This configuration supports specific antibody capture and signal generation, enabling evaluation of IgM-class antiviral reactivity in serum and plasma matrices. Because the detection conjugate is directed against the mu heavy chain of human IgM, the readout is restricted to the IgM isotype and does not report total antiviral immunoglobulin content — an important distinction when IgM and IgG classes are studied as separate analytes in a paired serological design.
|
Feature |
Benefit |
|
Solid-phase ELISA format |
Established principle for antiviral IgM detection |
|
Anti-human IgM detection |
IgM-isotype specific readout, not total immunoglobulin |
|
Viral antigen coating |
Presents native capsid conformational epitopes |
|
Cut-off index evaluation |
Standardised semi-quantitative interpretation |
Icosahedral Capsid Antigen with Repetitive Surface Epitopes
The HAV capsid is an icosahedral shell assembled from 60 copies of the VP1–VP3 subunits, which places the neutralising epitopes in a highly ordered, repetitive array across the particle surface. Because the capsid is non-enveloped, these epitopes are exposed directly on the virion exterior rather than embedded beneath a lipid bilayer, and they depend on the folded quaternary structure of the capsid rather than on linear sequence alone. Coating with a whole-virus antigen preparation therefore preserves the conformational capsid epitopes recognised by antibodies raised against the intact particle, in contrast to formats that present denatured or isolated recombinant capsid fragments. This structural characteristic also makes the antigen a favourable substrate for multivalent antibody engagement, as described below.
|
Feature |
Benefit |
|
Whole-virus capsid antigen coating |
Preserves conformational quaternary epitopes |
|
60-subunit icosahedral array |
Highly ordered, repetitive surface epitope display |
|
Non-enveloped particle |
Capsid epitopes exposed directly on the virion surface |
|
Distinct from recombinant-fragment formats |
Complements single-antigen ELISA configurations |
Pentameric IgM Binding to a Repetitive Capsid Epitope Array
Repetitive epitope display is precisely the geometry in which IgM's pentameric architecture confers its advantage: with ten antigen-binding sites per molecule, IgM engages multiple capsid epitopes simultaneously, generating high functional avidity through multivalent attachment even where the intrinsic affinity of an individual site is modest. This structure–function relationship is specific to IgM and does not apply equivalently to the monomeric IgG configuration, which makes the IgM isotype a distinct analytical window on anti-HAV reactivity rather than a simple replicate of the IgG response. The same principle underlies the well-established use of repetitive virion surfaces as multivalent antigen substrates in antiviral serology.
|
Feature |
Benefit |
|
Pentameric IgM with ten binding sites |
High functional avidity on repetitive capsid arrays |
|
Early-phase isotype positioning |
Captures the first antiviral antibody class to appear |
|
Paired isotype design |
Supports IgM and IgG comparison in the same format |
|
Isotype-resolved conjugate |
IgM readout independent of IgG content |
Performance Aligned with Published Antiviral IgM ELISA Benchmarks
Published performance data for ELISA-format antiviral IgM assays report sample volumes of 50–100 µL, a colorimetric microplate readout at 450 nm, and time to results of approximately 1–5 hours, with results expressed as a cut-off index derived from kit calibrators rather than a mass-concentration standard. Precision data for antibody-class ELISA formats of this type generally indicate intra-assay CV values below 10% and inter-assay CV values below 15%. Sample volumes of 50 µL are used in this configuration, and absorbance is read at 450 nm. Because the same assay format is commonly applied to paired IgM and IgG determinations, laboratory professionals should confirm the applicable calibrator and cut-off definitions against the kit documentation supplied with each lot, and should exercise independent judgment in interpreting cut-off index values in a research context.
|
Feature |
Benefit |
|
Cut-off index based semi-quantitative readout (published benchmark) |
Standardised qualitative and semi-quantitative framework |
|
Intra-assay CV <10%; inter-assay CV <15% (published benchmark) |
Repeatability and reproducibility suitable for laboratory use |
|
Arbitrary unit reporting |
Consistent with established antiviral ELISA practice |
Standardized 96-Well Workflow with 50 µL Sample Volume
The assay is formatted for standard 96-well microplate processing with a 50 µL sample volume and a total incubation time of approximately 1.5–2.5 hours. Absorbance is measured at 450 nm, aligning with widely available ELISA readers and washers.
|
Feature |
Benefit |
|
96 tests/box |
Practical batch configuration for research workflows |
|
50 µL sample volume |
Standard ELISA sample requirement |
|
450 nm reading |
Compatible with common microplate spectrophotometers |
|
~1.5–2.5 hour total incubation |
Efficient turnaround for batch processing |
18-Month Shelf Life
Extended reagent stability supports inventory planning and reduces replacement frequency in laboratory settings.
|
Feature |
Benefit |
|
18-month shelf life |
Extended inventory stability |
|
Consistent batch supply |
Supports repeatable research workflows |
Kit Contents & Pricing (EXW US Dollar)
|
Product Description |
Package |
Shelf Life |
Price/Kit (USD) |
CPT (USD/Test) |
|
HAV Hepatitis A Virus Antibody IgM ELISA Kit |
96 Tests/Box |
18 Months |
$28.00 |
$0.2917 |
Cost per test: approximately $0.29, based on a 96-test kit configuration.
Product Specifications
|
Specification |
Detail |
|
Model / SKU |
GHM HAV Hepatitis A Virus Antibody IgM ELISA Kit US |
|
Product Type |
Enzyme-Linked Immunosorbent Assay (ELISA) Kit |
|
Intended Use |
Semi-quantitative determination of anti-HAV antibody IgM in human serum or plasma; for laboratory research use only; not for use in diagnostic procedures; not for therapeutic use |
|
Assay Principle |
Solid-phase ELISA with anti-human IgM detection |
|
Target Analyte |
Anti-hepatitis A virus antibody, immunoglobulin M (IgM) class |
|
Immunoglobulin Class |
IgM (mu heavy chain specific; pentameric) |
|
Antigen |
HAV antigen (whole-virus preparation; VP1–VP3 icosahedral capsid epitopes) |
|
Specimen Types |
Human serum, plasma |
|
Specimen Volume |
50 µL/well |
|
Package Size |
96 Tests/Box |
|
Shelf Life |
18 Months |
|
Reading Wavelength |
450 nm |
|
Total Incubation Time |
Approximately 1.5–2.5 hours (protocol-dependent) |
|
Precision (published benchmark) |
Intra-assay CV <10%; inter-assay CV <15% |
|
Result Interpretation |
Cut-off index based semi-quantitative readout (published benchmark) |
|
Calibration Format |
Cut-off index referenced to kit calibrators (not mass-concentration calibrated) |
|
Regulatory Status |
Manufactured under EN ISO 13485 certified quality management system |
Why Laboratories Choose Global Healthcare Medical
|
Consideration |
GHM HAV Hepatitis A Virus Antibody IgM ELISA Kit US |
|
Solid-phase ELISA with anti-human IgM detection |
IgM-isotype specific readout, not total immunoglobulin |
|
Whole-virus capsid antigen coating |
Preserves conformational quaternary epitopes |
|
Pentameric IgM on a repetitive capsid array |
Ten binding sites per molecule; high functional avidity |
|
Paired isotype design |
Supports IgM and IgG comparison in the same format |
|
Performance aligned with published antiviral IgM ELISA benchmarks |
Cut-off index based; CV <10%/<15% |
|
Cost-effective research serology |
$0.2917 per test; $28.00 per 96-test kit |
|
18-month shelf life |
Extended inventory stability |
|
Standard 96-well format |
Compatible with routine ELISA equipment |
|
ISO 13485 certified |
Quality management system compliance |
About Global Healthcare Medical
Global Healthcare Medical connects clinical laboratories, research institutions, and blood screening centers with diagnostic reagents and analytical systems designed for reliable operation in demanding healthcare environments. The GHM HAV Hepatitis A Virus Antibody IgM ELISA Kit US is part of our professional ELISA reagent portfolio, developed to support standardized, reproducible laboratory workflows.
Our focus is on dependable analytical performance, clear documentation, and responsive support for professional laboratory operations.